Wiesner Staining for Visualizing Lignin: A Technique to Stain Lignin Deposits Present in Stems of Arabidopsis Thaliana

Published: April 30, 2023

Abstract

Source: Pradhan Mitra, P. et al., Histochemical Staining of Arabidopsis thaliana Secondary Cell Wall Elements. J. Vis. Exp. (2014).

In this video, we describe the Wiesner staining technique for staining the lignin present in specialized plant cells. This staining technique helps to visualize the lignified cell walls in Arabidopsis thaliana stems and helps to quantify the lignification in the cell walls of different types of cells.

Protocol

1. Stem Embedding

  1. Make a 7% agarose solution in water (7 g of electrophoresis-grade agarose in 100 ml distilled water). Dissolve the agarose by autoclaving for 20 min or by microwaving for 20 min at lowest intensity (e.g., 10% intensity of a 1,250-watt microwave).
  2. Prepare a homemade mold for embedding the stems using plastic vials.
    1. Using a razor blade, cut off the conical bottom of a 2 ml screw-cap microcentrifuge tube (Part A). With a syringe needle, puncture a hole in the tube cap slightly larger than the diameter of the stem to be embedded. Next, cut 0.5 cm off the bottom of a 0.6 ml microcentrifuge tube (Part B).
    2. Add the cut-off 0.5 cm portion of the 0.6 ml microcentrifuge tube into the precut 2 ml microcentrifuge tube. Seal the two parts using Parafilm (Figure 1).
      NOTE: The bottom of the tube is cut to facilitate the removal of the embedded sample after the agarose has solidified. The hole in the cap will aid in holding the stem steady when the stem is embedded in agarose. The mold will serve to hold the agarose and hold the stem straight when embedding. The Parafilm will hold the two parts, A and B, until the agarose is set and the stem is embedded.
    3. Using a razor blade, cut a stem section from the area of interest, (e.g. middle of the first stem internode).
      NOTE: Ideally, the stem should be cut just before embedding to avoid destruction by dehydration. Alternatively, the stem can be temporarily stored in a plate containing a filter paper wetted with water. This plate can be placed on ice until ready to be embedded to prevent tissue dehydration and deformation. Storing the stem for periods longer than 30 min without high moisture will cause the stem to dry out.
  3. Melt the agarose in the microwave at low intensity.
    CAUTION: The bottle containing agarose may be hot. Use a mitt to pick up the bottle. Let the melted agarose stand at room temperature (between 20 °C and 25 °C) until it cools to about 50 °C.
  4. Slowly pipette 5 ml of the agarose into the premade plastic mold to fill the vial.
    NOTE: Make sure there are no air bubbles in the molds. Air bubbles will cause gaps in the agarose mold and will not completely cover the stem sample, which will eventually lead to uneven cutting of the sample sections.
    1. Let the agarose cool down for 30 to 60 sec to become semisolid. Test with a small toothpick, making sure that it can penetrate and stand up, but not float, in the agarose.
      NOTE: If the stem is placed when the agarose is still hot it will damage the sample by shriveling the stem, destroying the cell morphology.
    2. Place the stem in this agarose-filled vial. Make sure that the stem stays straight. Place the perforated cap in such a way that the tip of the stem is held by the cap. Do not turn the screw-on cap. Sometime more than one stem (of a single kind) can be embedded in a single vial; but in that case, do not use the cap.
      NOTE: If the screw-on cap is turned, the stem will get twisted.
  5. Leave the vial at room temperature or at 4 °C for 10-30 min, until it solidifies.
  6. Remove the mold by gently sliding it out of the tube. Open the Parafilm. Push the bottom of Part B of the mold gently with thumb to release the solidified agarose from Part A onto a glass microscope slide.
  7. Cut the agarose embedded stem into three approximately equal pieces of 1.2 cm in length. Cut out the part of the stem that was not in the agarose and discard it.
    1. Store these pieces of agarose with the embedded stems in airtight 2 ml microcentrifuge tubes in a dark box at 4 °C until ready to section. Alternatively, store the tubes at 4 °C for a maximum of one week.
      NOTE: Storage is possible, but the experimenter needs to be aware that the embedded stems are still alive and, depending on the experiment, artifacts could potentially be introduced.

2. Stem Sectioning

CAUTION: Read the vibratome manual carefully and follow all safety instructions.

  1. Make sure the specimen disc is clean and completely dry (free of any solid or liquid). Clean the specimen disc with a razor blade to remove any residual glue from prior experiments and wash with water. Then dry with a paper towel.
    NOTE: This will ensure that the adhesive works well and binds to the agarose specimen. If this step is not done properly, it is possible that the specimen may not adhere to the disc and will later cause the specimen to fall off the disc during sectioning.
    1. Use soft paper wipes to remove any moisture from the agarose block containing the specimens.
    2. Place a small drop of tissue adhesive on the specimen disc. Streak out the adhesive to cover the area in the middle of the plate using the tip of the adhesive bottle. Quickly place the agarose block so that the specimens are either perpendicular to or in parallel with the plate for transversal or longitudinal cross-sections, respectively. Allow the adhesive to fix the sample to the specimen disc at room temperature or at 4 °C for 10-30 min. NOTE: This is a time-sensitive step.
  2. Fix the specimen disc in place on the buffer tray or trough. The block/s of agarose with the sections should be in parallel with the razor blade. Fill the buffer tray with distilled water at room temperature until the samples are completely submerged.
  3. Cut a razor blade in half and then trim the ends with a sturdy scissors so that the blade stays completely flat. Attach one-half of the precut razor blade onto the knife holder.
    1. Set the angle on the knife holder to 84°, the speed to 0.90 mm/sec (position 8 on the vibratome) and frequency to 50 Hz (position 5 on the vibratome). Cut sections of 100 µm thickness. Use continuous mode. NOTE: This thickness was selected to assure that the tissue can withstand the various acid and base treatments used in some of the staining protocols. Set the window for sectioning and allow 15-20 min on a continuous mode for the vibratome to section an agarose block of approximately 1.2 cm.
  4. Collect the sections using a disposable plastic pipette during sectioning in the buffer tray. Alternatively, the sections can be transferred from the buffer tray into a glass beaker and then to a clear Petri plate. Transfer few sections to the 2.0 ml microcentrifuge tubes. Note: The specimens are collected from a Petri plate because it is easier to see the sections on a clear background, and because the buffer tray can be primed for the next specimen.
  5. The sections can be stored in a 50 ml tube or collected and stored in 1.5 to 2 ml microcentrifuge tubes at 4 °C for 30 to 60 min.
    NOTE: Storing the sections for longer periods will result in poor image quality.

3. Phloroglucinol-HCl (Wiesner) Staining

  1. Dissolve 0.3 g of phloroglucinol in 10 ml absolute ethanol to prepare a 3% phloroglucinol solution. Mix one volume of concentrated HCl (37 N) to two volumes of 3% phloroglucinol in ethanol; this solution is phloroglucinol-HCl (Ph-HCl) or Wiesner stain.
    NOTE: This solution is to be made fresh on the day of the staining and cannot be stored, because the solution will degrade over time and the staining will become ineffective.
    CAUTION: HCl is highly corrosive, so use extreme caution while handling the Ph-HCl stain.
  2. Transfer stem sections to a 2.0 ml microcentrifuge tube. Add 1 ml of the Ph-HCl solution to the tube containing the sections and cap it immediately because the HCl in the Ph-HCl stain is highly corrosive. Gently move the tube to assure that all the sections are stained. An alternative to this step is to keep the tube cap open so that the Ph-HCl solution can be pipetted up and down, preferably without disturbing the sections.
    NOTE: Be careful not to pipette the sections into the pipette tip, as this may damage those sections.
    1. Use a 1 ml pipette with the pipette tip cut in such a way that the sections can be pipetted out easily without damage. Gently pipette sections into the tip and onto a microscope slide. Cover the sections with cover slip. Observe the sections under bright-field lighting. (Figure 2)
      NOTE:
      The Ph-HCl solution dries up in 5-10 min, causing a deterioration of the specimens. Therefore, the imaging has to be completed within that period of time.

Representative Results

Figure 1
Figure 1. Homemade mold for embedding the stems. On the left side; top of the 2 ml screw-cap microcentrifuge tube (Part A) and the bottom from the 0.6 ml microcentrifuge tube (Part B). On the right side; the Parafilm holding the two parts; A and B to form the final mold.

Figure 2
Figure 2. Phloroglucinol-HCl staining of A. thaliana stem cross-sections. Phloroglucinol-HCl staining (pink or fuchsia color) of a wild type A. thaliana stem section showing the normal lignin deposition in the walls of interfascicular fibers and xylem cells (AE). The positions of the epidermis and cortex (Ep), interfascicular fibers (Fi), pith (Pi), and xylem (Xy) are indicated. Magnifications: Panel A: 5X; Panel B: 10X; Panel C: 20X; Panels D and E: 40X. Bar = 100 µm.

Divulgations

The authors have nothing to disclose.

Materials

Agarose   EMD MERC2125  CAS Number: 9012-36-6
Phloroglucinol   Sigma P 3502  1,3,5-trihydroxybenzene [CAS Number: 108-73-6]
Hydrochloric acid    EMD HX0603-75 CAS Number: 7647-01-0
Ethanol 190 proof    KOPTEC V1401 CAS Number: 64-17-5
Vibratome   Leica  Leica Vibrating blade microtome VT1000S http://www.leicabiosystems.com/ products/sectioning/vibratingblade-microtomes/details/product/ leica-vt1000-s/
Razor   American Safety razor company  Item # 60-0139-0000 Stainless Steel Double Edge Blade (Personna Super)
Screw Cap Microcentrifuge Tubes (2 ml)   VWR 16466-044
Microcentrifuge Tubes (0.6 ml)   Axygen Scientific  MCT-060-C
Tissue adhesive   Ted Pella Inc 10033 Store at 4 °C or 20 °C for 3 months or longer storage
Camera with CCD chip with no mechanical shutter  Hamamatsu  C4742-95
Camera software   Molecular Devices MetaMorph version 7.7.0.0
Imagining anaylsis   Adobe Photoshop CS4
Micro Cover Glasses, Square, No. 1  VWR  48366-067  22 x 22 mm (7/8 x 7/8")-Cover glasses are corrosion-resistant
Frosted Micro Slides, 1 mm    VWR 48312-003 75 x 25 mm – 1 mm

Tags

check_url/fr/21057?article_type=t

Play Video

Citer Cet Article
Wiesner Staining for Visualizing Lignin: A Technique to Stain Lignin Deposits Present in Stems of Arabidopsis Thaliana. J. Vis. Exp. (Pending Publication), e21057, doi: (2023).

View Video