Summary

Rigidité réglable, fixateur externe pour les modèles Rat fémur ostéotomie segmentaire et défauts osseux

Published: October 09, 2014
doi:

Summary

One constraint of preclinical research in the field of bone repair is the lack of experimental control over the local mechanical environment within a healing bone lesion. We report the design and use of an external fixator for bone repair with the ability to change fixator stiffness in vivo.

Abstract

L'environnement mécanique autour de la guérison des os cassé est très importante car elle détermine la façon dont la fracture va guérir. Au cours de la dernière décennie, il ya eu un grand intérêt clinique dans l'amélioration de la cicatrisation osseuse en modifiant l'environnement mécanique par la stabilité de la fixation autour de la lésion. Une contrainte de la recherche animale préclinique dans ce domaine est le manque de contrôle expérimental sur l'environnement mécanique locale dans un grand défaut segmentaire ainsi que ostéotomies car ils guérissent. Dans cet article, nous présentons la conception et l'utilisation d'un fixateur externe pour étudier la guérison des défauts importants segmentaire osseuses ou ostéotomies. Ce dispositif permet, non seulement de la rigidité axiale contrôlée sur la lésion de la moelle qu'elle guérit, mais il permet également la variation de la rigidité au cours du processus de cicatrisation in vivo. Les expériences réalisées ont montré que les fixateurs sont en mesure de maintenir un écart de défaut fémorale 5 mm chez le rat in vivo au cours de cage libreactivité pendant au moins 8 semaines. De même, nous n'avons observé aucune déformation ou d'infections, y compris les infections des broches au cours de la période de cicatrisation entier. Ces résultats démontrent que notre fixateur externe nouvellement développée a été en mesure de parvenir à stabiliser reproductible et normalisée, et l'altération de l'environnement mécanique in vivo chez le rat défauts grand osseuses et diverses ostéotomies de taille. Cela confirme que le dispositif de fixation externe est bien adapté pour des enquêtes de recherche préclinique utilisant un modèle de rat dans le domaine de la régénération osseuse et la réparation.

Introduction

Un certain nombre d'études ont permis de mieux comprendre les mécanismes biologiques impliqués dans la réparation des tissus osseux 1-6. Les effets des conditions mécaniques sur la réparation osseuse tels que axiale, cisaillement et des mouvements interfragmentaires (MFI) ont été largement étudiés 7-15. Au cours des dernières années, de plus en plus d'études ont commencé à émerger décrivant l'influence de l'environnement mécanique sur la cicatrisation osseuse en utilisant une fracture, une ostéotomie et une grande perte de substance osseuse segmentaire dans des modèles in vivo. Par conséquent, les méthodes de fixation fiables sont nécessaires pour obtenir des résultats reproductibles et fiables étude.

L'environnement mécanique autour de la fracture de guérison est très importante car elle détermine la façon dont la fracture va guérir. Ainsi, le choix du dispositif de fixation est très important et doit être soigneusement choisie en fonction de la conception de l'étude, ainsi que d'autres facteurs tels que la taille de l'espace et du type de fracture. Les propriétés mécaniques du dispositif de fixation d'unre encore plus important lorsque l'on étudie la cicatrisation osseuse de grands défauts osseux pour établir une fixation qui ne fournit pas seulement une dimension de l'intervalle constant tout au long de la période d'essai de charge complète, mais également un environnement idéal pour la mécanique de l'os de la guérison. Les fixateurs externes sont couramment utilisés dans les fractures et les grands modèles expérimentaux de guérison des défauts osseux car elles ont un avantage sur d'autres dispositifs de fixation. Le principal avantage de fixateurs externes sont qu'ils permettent la modification de l'environnement mécanique au niveau du site du défaut in vivo sans une intervention secondaire qui peut être obtenue en changeant ou en ajustant la barre de la stabilité de l'appareil au cours de l'expérience, comme l' cicatrisation osseuse progresse. En outre, elle permet l'application de la stimulation mécanique locale spécifique pour améliorer la réparation de l'os, et fournit aussi la possibilité de mesurer la rigidité d'un tissu de cal in vivo. Néanmoins, les dispositifs ont aussi quelques inconvénientsqui comprennent: irritation des tissus mous, les infections et la broche rupture.

Malheureusement, ces implants ne sont pas disponibles «sur étagère» au moment de l'élaboration de l'implant, et les enquêteurs ont été contraints de concevoir sur mesure leurs propres fixateurs pour une utilisation prévue. Par conséquent, une contrainte de la recherche dans ce domaine est le manque de contrôle expérimental sur l'environnement mécanique locale dans un grand défaut segmentaire ainsi que ostéotomies car il guérit. Les caractéristiques mécaniques d'un fixateur externe sont définis par, et peuvent être modulées par un grand nombre de variables qui comprennent: la distance entre les broches, diamètre de la tige, Matériau de l'axe, le nombre de broches, fixateur longueur de la barre, numéro de barre de fixateur, matériau fixateur de la barre, l'épaisseur de la barre de fixateur et la distance entre la surface de l'os de la barre de fixateur (offset). Étonnamment, seulement un manque d'études pourrait être trouvée qui ont étudié les contributions mécaniques des composants individuelsde fixateurs ou des configurations de châssis entiers utilisés dans les études sur les rongeurs 16,18,28. Par exemple, les résultats d'une seule étude ont montré que l'un des principaux facteurs contribuant à la détermination de la rigidité totale de la construction de fixation a été dominée par la flexibilité des broches par rapport à leurs offset, diamètre et les propriétés des matériaux 28. Les résultats des études ci-dessus montrent clairement que la connaissance de l'environnement mécanique fournie par le dispositif de fixation est très important, mais, dans de nombreux cas n'est pas étudié en détail. Cet article présente l'implantation conception, les spécifications, et in vivo d'un fixateur externe qui résout ce problème. Ce fixateur permet également la modulation de l'environnement mécanique cicatrisation progresse, une propriété qui permet l'étude de la mécano-sensibilité de différentes étapes du processus de cicatrisation in vivo. En outre, ainsi que l'imposition d'une mécanique locale contrôlée et reproductibleal environnement, son accessibilité permet également pour la modulation de ce milieu à différents stades de la cicatrisation osseuse.

Le fixateur nous avons conçu a été basée sur la fixation externe, qui est largement utilisé pour la fixation des fractures 16-21 et les grands modèles de défauts dans les animaux de laboratoire 22-27. La différence entre notre fixateur externe et les autres modèles existants dans la littérature est que leur barre de stabilité est fixé avec des vis à avoir une mainmise de broches de Kirschner (K-fils). Ce type de conception nécessite des vis à resserrer toutes les deux semaines (parfois même hebdomadaire) pour s'assurer que la distance du décalage est maintenu que le chargement est appliqué par roulement de poids pour empêcher le relâchement de la barre de stabilité. Si tel relâchement se produit, il permet des conditions de chargement supplémentaires indésirables tels que angulaire, transversale et les mouvements de cisaillement de torsion à l'os de guérison (basé sur l'expérience personnelle, la communication avec researchers). Sachant cela, un fixateur externe a été conçu en tant que telle que, lorsque la rigidité du fixateur doit être changé, il serait obtenue en retirant des éléments de connexion reliés au module principal où les broches de montage sont noyés. L'expérience pilote in vivo a été réalisée avec le nouveau prototype de fixateur externe pour s'assurer qu'il remplit toutes les exigences proposées avant d'être fabriqué en grandes quantités.

L'objectif principal de cet article est de présenter une nouvelle méthode chirurgicale pour un fixateur externe utilisé pour les grands défauts osseux et ostéotomies chez le rat avec la possibilité de modifier la rigidité in vivo au cours du processus de guérison. Ce mode de fixation est appliquée in vivo sur le fémur de rat.

Protocol

Les soins et les protocoles expérimentaux ont été suivies conformément aux directives du NIH et approuvés par le Centre médical de l'établissement de soins et d'utilisation des animaux Comité Beth Israel Deaconess, Boston, MA. (Numéro de protocole: 098-2009) 1 Préparation du matériel et les instruments chirurgicaux Stériliser tous les matériaux et instruments chirurgicaux utilisés pour effectuer une intervention chirurgicale avant de l'utiliser. Emballez …

Representative Results

Les spécifications de conception Stabilisation du fémur de rat avec le système de fixation externe permet la création d'ostéotomies de 0,5 à 5 mm. Le système de fixateur externe est un fixateur externe verrouillé en polyéther-éther-cétone (PEEK – [le corps]) et de titane-aluminium-niobium alliage (TAN – [les broches de montage]), qui offre un design simple, reproductible et adaptable, et est disponible en quatre raideurs différentes: 10, 40, 70 et 100% (100% étant la norme, fix…

Discussion

The most critical steps of a surgical procedure to create a large bone defect are: 1) choosing the appropriate body weight of the rat to match the size of the external fixator; 2) maintaining a sterile environment during the procedure; and 3) following the surgical procedure protocol.

The main goals of this study were to design, manufacture and characterize a new, variable stiffness external fixator for the rat femoral large defect model, and to use this fixator in determining the interplay be…

Divulgations

The authors have nothing to disclose.

Acknowledgements

This work was supported by the AO foundation (S-08-42G) and RISystem AG.

We would like to extend a very big "thank you!" to Stephan Zeiter's team at the AO Research Institute Davos, Switzerland for being so accommodating in allowing us to use their OR facilities for the filming of this surgical procedure.

Materials

Name of Material/ Equipment Company Catalog Number Comments/Description
RatExFix simple 100% RISystem AG Davos, Switzerland RIS.612.120
RatExFix simple 70% RISystem AG Davos, Switzerland RIS.612.123
RatExFix simple 40% RISystem AG Davos, Switzerland RIS.612.121
RatExFix simple 10% RISystem AG Davos, Switzerland RIS.612.122
RatExFix Connection element 100% RISystem AG Davos, Switzerland RIS.612.130
RatExFix Connection element 70% RISystem AG Davos, Switzerland RIS.612.131
RatExFix Connection element 40% RISystem AG Davos, Switzerland RIS.612.132
RatExFix Connection element 10% RISystem AG Davos, Switzerland RIS.612.133
RatExFix Main body RISystem AG Davos, Switzerland RIS.611.101
RatExFix InterlockingScrew RISystem AG Davos, Switzerland RIS.412.110
RatExFix Mounting pin 0.85 mm RISystem AG Davos, Switzerland RIS.412.100
RatExFix Saw Guide 100% 5 mm RISystem AG Davos, Switzerland RIS.312.100
Accu Pen 6V+ RISystem AG Davos, Switzerland RIS.390.211
HandDrill RISystem AG Davos, Switzerland RIS.390.130
Drill Bit 0.79 mm RISystem AG Davos, Switzerland RIS.593.203
Gigly wire saw 0.22 mm RISystem AG Davos, Switzerland RIS.590.100
Square box wrench 0.70 mm RISystem AG Davos, Switzerland RIS.590.112
Square box wrench 0.50 mm RISystem AG Davos, Switzerland RIS.590.111
Centering bit 1.00 mm RISystem AG Davos, Switzerland RIS.592.205
Scalpel Blade handle Fine Science tools
Scalpel Blade (Size 15) Fisher Scientific
Tissue Forceps Fine Science tools
Scissors Fine Science tools
Retractor Fine Science tools
Needle Holder Fine Science tools
Henahan Elevator Fine Science tools
S-shape curved dissecting and ligature forceps  Fine Science tools 2
Dressing Forceps Fine Science tools 2
Sterile Fenestrated drape Fisher Scientific for surgery
Sterile gauze Fisher Scientific for surgery
5 ml syringe  Fisher Scientific  for irrigation of defect
24-27G needle  Fisher Scientific  for irrigation of defect
1cc Insulin syringes  Fisher Scientific for drug injections
sterile saline  Fisher Scientific for bone defect irrigation
sterile gloves Fisher Scientific to perform surgeries
chlorohezadine Fisher Scientific disinfecting solution for surgical site
Vicryl suture 4-0 with SH-1 Fisher Scientific to suture muscle 
Ethibond suture 3-0  Fisher Scientific to suture skin
Isofluorine Sigma-Aldrich for anesthesia
Buprenorphine Sigma-Aldrich analgesia during and after the surgery
Cefazolin Sigma-Aldrich antibiotic during and after the surgery 
Sprague-Dawley Rats or any other strain Charles River Laboratories International, Inc. (Wilmington, MA USA) 

References

  1. Einhorn, T. A., Lane, J. M., Burstein, A. H., Kopman, C. R., Vigorita, V. J. The healing of segmental bone defects induced by demineralized bone matrix. A radiographic and biomechanical study. J Bone Joint Surg Am. 66, 274-279 (1984).
  2. Feighan, J. E., Davy, D., Prewett, A. B., Stevenson, S. Induction of bone by a demineralized bone matrix gel: a study in a rat femoral defect model. J Orthop Res. 13, 881-891 (1995).
  3. Hunt, T. R., Schwappach, J. R., Anderson, H. C. Healing of a segmental defect in the rat femur with use of an extract from a cultured human osteosarcoma cell-line (Saos-2). A preliminary report. J Bone Joint Surg Am. 78, 41-48 (1996).
  4. Jazrawi, L. M., et al. Bone and cartilage formation in an experimental model of distraction osteogenesis. J Orthop Trauma. 12, 111-116 (1998).
  5. Probst, A., Jansen, H., Ladas, A., Spiegel, H. U. Callus formation and fixation rigidity: a fracture model in rats. J Orthop Res. 17, 256-260 (1999).
  6. Richards, M., Huibregtse, B. A., Caplan, A. I., Goulet, J. A., Goldstein, S. A. Marrow-derived progenitor cell injections enhance new bone formation during distraction. J Orthop Res. 17, 900-908 (1999).
  7. Aro, H. T., Chao, E. Y. Bone-healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression. Clin Orthop Relat Res. , 8-17 (1993).
  8. Augat, P., et al. Shear movement at the fracture site delays healing in a diaphyseal fracture model. J Orthop Res. 21, 1011-1017 (2003).
  9. Augat, P., et al. Local tissue properties in bone healing: influence of size and stability of the osteotomy gap. J Orthop Res. 16, 475-481 (1998).
  10. Claes, L., Augat, P., Suger, G., Wilke, H. J. Influence of size and stability of the osteotomy gap on the success of fracture healing. J Orthop Res. 15, 577-584 (1997).
  11. Claes, L., Eckert-Hubner, K., Augat, P. The fracture gap size influences the local vascularization and tissue differentiation in callus healing. Langenbecks Arch Surg. 388, 316-322 (2003).
  12. Duda, G. N., et al. Interfragmentary motion in tibial osteotomies stabilized with ring fixators. Clin Orthop Relat Res. , 163-172 (2002).
  13. Goodship, A. E., Watkins, P. E., Rigby, H. S., Kenwright, J. The role of fixator frame stiffness in the control of fracture healing. An experimental study. J Biomech. 26, 1027-1035 (1993).
  14. Williams, E. A., Rand, J. A., An, K. N., Chao, E. Y., Kelly, P. J. The early healing of tibial osteotomies stabilized by one-plane or two-plane external fixation. J Bone Joint Surg Am. 69, 355-365 (1987).
  15. Wu, J. J., Shyr, H. S., Chao, E. Y., Kelly, P. J. Comparison of osteotomy healing under external fixation devices with different stiffness characteristics. J Bone Joint Surg Am. 66, 1258-1264 (1984).
  16. Harrison, L. J., Cunningham, J. L., Stromberg, L., Goodship, A. E. Controlled induction of a pseudarthrosis: a study using a rodent model. J Orthop Trauma. 17, 11-21 (2003).
  17. Kaspar, K., Schell, H., Toben, D., Matziolis, G., Bail, H. J. An easily reproducible and biomechanically standardized model to investigate bone healing in rats, using external fixation. Biomed Tech (Berl). 52, 383-390 (2007).
  18. Mark, H., Bergholm, J., Nilsson, A., Rydevik, B., Stromberg, L. An external fixation method and device to study fracture healing in rats. Acta Orthop Scand. 74, 476-482 (2003).
  19. Mark, H., Nilsson, A., Nannmark, U., Rydevik, B. Effects of fracture fixation stability on ossification in healing fractures. Clin Orthop Relat. Res. , 245-250 (2004).
  20. Mark, H., Rydevik, B. Torsional stiffness in healing fractures: influence of ossification: an experimental study in rats. Acta Orthop. 76, 428-433 (2005).
  21. McCann, R. M., et al. Effect of osteoporosis on bone mineral density and fracture repair in a rat femoral fracture model. J Orthop Res. 26, 384-393 (2008).
  22. Betz, O. B., et al. Direct percutaneous gene delivery to enhance healing of segmental bone defects. J Bone Joint Surg Am. 88, 355-365 (2006).
  23. Cullinane, D. M., et al. Induction of a neoarthrosis by precisely controlled motion in an experimental mid-femoral defect. J Orthop Res. 20, 579-586 (2002).
  24. Dickson, G. R., Geddis, C., Fazzalari, N., Marsh, D., Parkinson, I. Microcomputed tomography imaging in a rat model of delayed union/non-union fracture. J Orthop Res. 26, 729-736 (2008).
  25. Jager, M., Sager, M., Lensing-Hohn, S., Krauspe, R. The critical size bony defect in a small animal for bone healing studies (II): implant evolution and surgical technique on a rat’s femur. Biomed Tech (Berl). 50, 137-142 (2005).
  26. Betz, V. M., et al. Healing of segmental bone defects by direct percutaneous gene delivery: effect of vector dose. Hum Gene Ther. 18, 907-915 (2007).
  27. Glatt, V., et al. Ability of recombinant human bone morphogenetic protein 2 to enhance bone healing in the presence of tobramycin: evaluation in a rat segmental defect model. J Orthop Trauma. 23, 693-701 (2009).
  28. Willie, B., Adkins, K., Zheng, X., Simon, U., Claes, L. Mechanical characterization of external fixator stiffness for a rat femoral fracture model. J Orthop Res. 27, 687-693 (2009).
  29. Hess, T., Hopf, T., Fritsch, E., Mittelmeier, H. Comparative biomechanical studies of conventional and self-tapping cortical bone screws. Z Orthop Ihre Grenzgeb. 129, 278-282 (1991).
  30. Glatt, V., Evans, C. H., Matthys, R. Design, characterisation and in vivo testing of a new, adjustable stiffness, external fixator for the rat femur. Eur Cell Mater. 23, 289-298 (2012).
  31. Glatt, V., et al. Improved healing of large segmental defects in the rat femur by reverse dynamization in the presence of bone morphogenetic protein-2. J Bone Joint Surg Am. 94, 2063-2073 (2012).