Summary

In Situ Detectie van autoreactieve CD4 T-cellen in de hersenen en het hart met behulp van Hoofdhistocompatibiliteitscomplex Klasse II Dextramers

Published: August 01, 2014
doi:

Summary

Is beschreven het protocol tot zelf-reactieve CD4 T-cellen te detecteren in de hersenen en het hart door directe kleuring met hoofdhistocompatibiliteitscomplex klasse II dextramers in dit rapport. Voor uitgebreide analyse is een betrouwbare methode om de frequentie van antigeen-specifieke CD4 + T-cellen in situ sommen ook ontwikkeld.

Abstract

This report demonstrates the use of major histocompatibility complex (MHC) class II dextramers for detection of autoreactive CD4 T cells in situ in myelin proteolipid protein (PLP) 139-151-induced experimental autoimmune encephalomyelitis (EAE) in SJL mice and cardiac myosin heavy chain-α (Myhc) 334-352-induced experimental autoimmune myocarditis (EAM) in A/J mice. Two sets of cocktails of dextramer reagents were used, where dextramers+ cells were analyzed by laser scanning confocal microscope (LSCM): EAE, IAs/PLP 139-151 dextramers (specific)/anti-CD4 and IAs/Theiler’s murine encephalomyelitis virus (TMEV) 70-86 dextramers (control)/anti-CD4; and EAM, IAk/Myhc 334-352 dextramers/anti-CD4 and IAk/bovine ribonuclease (RNase) 43-56 dextramers (control)/anti-CD4. LSCM analysis of brain sections obtained from EAE mice showed the presence of cells positive for CD4 and PLP 139-151 dextramers, but not TMEV 70-86 dextramers suggesting that the staining obtained with PLP 139-151 dextramers was specific. Likewise, heart sections prepared from EAM mice also revealed the presence of Myhc 334-352, but not RNase 43-56-dextramer+ cells as expected. Further, a comprehensive method has also been devised to quantitatively analyze the frequencies of antigen-specific CD4 T cells in the ‘Z’ serial images.

Introduction

Gebruik van major histocompatibility complex (MHC) klasse II tetrameren voor de detectie van antigeen-specifieke CD4 T-cellen is een uitdaging geweest 1-7. Om de gevoeligheid van MHC klasse II tetrameren verbeteren, heeft het onderzoeksteam gecreëerd volgende generatie tetrameren, aangeduid "dextramers" 8. Dextramers bevatten dextran ruggengraten waarbij meerdere streptavidine-fluorofoor resten geconjugeerd, zodanig dat verschillende peptide-gebonden, gebiotinyleerde MHC monomeren kan worden bevestigd aan een dextran-molecuul 9. Zo kunnen grote aggregaten van MHC dextramers dat verschillende MHC-peptidecomplexen bevatten interageren met meerdere T-celreceptoren (TCR).

Deze groep recent bekomen dextramers voor diverse zelf-antigenen en aangetoond dat de detectiegevoeligheid van dextramers ongeveer vijf keer meer dan tetrameren 8. De experimentele systemen zijn experimentele autoimmuun encefalomyelitis (EAE) geïnduceerd met proteolipid eiwit (PLP) 139-151 in SJL muizen; EAE geïnduceerd met myeline oligodendrocyt glycoproteïne (MOG) 35-55 in C57BL / 6 muizen; en experimentele auto-immune myocarditis (EAM) geïnduceerd met cardiale myosine zware keten-α (Myhc) 334-352 in A / J muizen. Deze studie demonstreert het gebruik van PLP 139-151 – en Myhc 334-352 dextramers antigeen-specifieke CD4 T-cellen te detecteren in situ met specificiteit Door een directe kleuring protocol, waardoor de noodzaak om de signalen te versterken gebruiken fluorofoor antilichamen, een benaderen gewoonlijk toegepast met behulp van tetrameren. Daarnaast is een uitgebreide methode evalueren weefsels ook bedacht betrouwbaar sommen de frequentie van antigeen-specifieke CD4 T-cellen in situ 10. Detectie van antigeen-specifieke T-cellen in situ maakt afbakening van gebeurtenissen veroorzaakt door specifieke antigene stimuli van die veroorzaakt door omstanders activatie. Ook de in situ techniek ook provides mogelijkheden om de kinetiek van antigeen-specifieke T cel infiltratie in de doelorganen volgen.

Protocol

Ethiek Verklaring: Alle dierlijke procedures werden uitgevoerd in overeenstemming met de richtlijnen voor de zorg en het gebruik van proefdieren en door de Universiteit van Nebraska-Lincoln, Lincoln, NE goedgekeurd. 1. Inductie van EAE EAE induceren bereiden peptide / compleet Freund's adjuvans (CFA) emulsie zoals beschreven in 11 de volgende wijzigingen: Stap 1.1:. Bereiden PLP 139-151 bij een concentratie van 1 mg / ml in 1 x me…

Representative Results

In dit verslag, in situ detectie van antigeen-specifieke autoreactieve CD4 T-cellen door directe kleuring met MHC klasse II dextramers beschreven. Vers gesneden cerebrale secties werden afgeleid van EAE muizen en gekleurd met cocktails met PLP 139-151 (specifieke) of TMEV 70-86 (controle) dextramers en anti-CD4. De bovenste panelen in Figuur 1 toont LSCM analyse van cerebrale secties costained met PLP 139-151 dextramers (rood) en CD4-antilichaam (groen), waar de dubbel-positieve cellen bleek ge…

Discussion

Unlike MHC klasse I tetrameren, het gebruik van MHC klasse II tetrameren voor routinetoepassingen blijft uitdagend, vooral voor de voorloper frequenties van lage affiniteit autoreactieve CD4 T-cellen, mede door hun activering afhankelijkheid 6,15-17 sommen. Onlangs werd dit probleem omzeild door het creëren van de volgende generatie van tetrameren, genaamd "dextramers," waardoor wij antigeen-specifieke CD4 T-cellen te detecteren voor een aantal auto-antigenen, zoals PLP 139-151, MOG 35-55 en Myhc 3…

Divulgations

The authors have nothing to disclose.

Acknowledgements

Dit werk werd ondersteund door de American Heart Association en de Children's Cardiomyopathie Foundation (SDG2462390204001), en de National Institutes of Health (HL114669). CM is een ontvanger van een postdoctoraal research fellowship subsidie ​​van de Myocarditis Foundation, NJ.

Materials

CFA Sigma Aldrich, St Louis, MO 5881 Store at 4οC
MTB  H37Rv extract  Difco Laboratories, Detroit, MI 231141 Store at 4οC
PT List Biologicals Laboratories, Campbell, CA 181 Store at 4οC
1x PBS  Corning, Manassas, VA 21-040-CV Store at 4οC
Female A/J mice  Jackson Laboratories, Bar Harbor, ME 646
Female SJL/J mice Jackson Laboratories, Bar Harbor, ME 686
Leur-lok sterile 1 ml syrringe BD, Franklin Lakes, NJ 309628
Leur-lok sterile 3 ml syrringe BD, Franklin Lakes, NJ 309657
Sterile needle, 18 G BD, Franklin Lakes, NJ 305195
Sterile needle, 27 1/2 G BD, Franklin Lakes, NJ 305109
3-way stopcock  Smiths Medical ASD, Inc. Dublin, OH MX5311L
Kerlix gauze bandage rolls  Covidien, Mansfield, MA 6720
Kimwipes Kimberly-Clark Professional, Roswell, GA 34155
Agarose, Low Melting Point, Analytical Grade Promega corporation, Madison, WI V2111
Immunopure normal goat serum Thermo Scientific, Waltham, MA 31873 Store at -20 οC
Anti-mouse CD4 conjugated with PE dye eBioscience, San Diego, CA  12004185 Store at 4οC
Paraformaldehyde Electron Microscopy Sciences, Hatfield, PA 19202 Store at 4οC
Faramount Aqueous Mounting Medium Dako, Carpinteria, CA 10073021
Conical tube (15ml) BD Biosciences, San Jose, CA 352099
Conical tube (50 ml) BD Biosciences, San Jose, CA 352070
24-well flat bottomed tissue culture plates BD Biosciences, San Jose, CA 356775
Water color #2 brushes Charles Leonard, Inc. Hauppauge, NY 73502
Plain Microscope slides, size: 3" x 1" x 1.2 mm Fisher Scientific, Pittsburgh, PA 1255010
Premium Cover glass, 22 x 22-1 Fisher Scientific, Pittsburgh, PA 12548B
Disposable deep base mold histology cassettes Laboratory prodcust, Rochester, NY M-475-10
Loctite Super glue Henkel Corporation, Westlake, OH 1471879
Razor blades Gillette SuperSilver
Myhc-a 334-352 (DSAFDVLSFTAEEKAGVYK) Neopeptide, Cambridge, MA Store at 4οC
PLP 139-151 (HSLGKWLGHPDKF) Neopeptide, Cambridge, MA Store at 4οC
MHC class II/IAs PLP 139-151 or TMEV 70-86 dextramers conjugated with APC dye Store at 4οC
MHC class II/IAk Myhc 334-352 or  or RNase 40-56 dextramers conjugated with APC dye Store at 4οC
Dextran conjugated SA-APC  Immundex, Copenhagen, Demark Store at 4οC
Sterile surgical scissors and forceps INOX tool Corporation
Micro oven GE Healthcare, Pittsuburgh, PA
Leica VT 1200 Vibratome Leica Microsystems, Inc. Buffalo Grove, IL
Olympus BX 60  Laser scanning confocal microscope Olympus America, Inc. Center Valley, PA
Nikon A1-Eclipse 90i confocal microscope Nikon Inc. Melville, NY

References

  1. Cecconi, V., Moro, M., Del Mare, ., Dellabona, S., P, G., Casorati, Use of MHC class II tetramers to investigate CD4+ T cell responses: problems and solutions. Cytometry A. 73 (11), 1010-1018 (2008).
  2. Ferlin, W., Glaichenhaus, N., Mougneau, E. Present difficulties and future promise of MHC multimers in autoimmune exploration. Curr Opin Immunol. 12, 670-675 (2000).
  3. Kwok, W. W., Ptacek, N. A., Liu, A. W., Buckner, J. H. Use of class II tetramers for identification of CD4+ T cells. J Immunol Methods. 268, 71-81 (2002).
  4. Landais, E., et al. New design of MHC class II tetramers to accommodate fundamental principles of antigen presentation. J Immunol. 183, 7949-7957 (2009).
  5. Nepom, G. T. MHC class II tetramers. J Immunol. 188, 2477-2482 (2012).
  6. Vollers, S. S., Stern, L. J. Class II major histocompatibility complex tetramer staining: progress, problems, and prospects. Immunology. 123, 305-313 (2008).
  7. Wooldridge, L., et al. Tricks with tetramers: how to get the most from multimeric peptide-MHC. Immunology. 126, 147-164 (2009).
  8. Massilamany, C., Upadhyaya, B., Gangaplara, A., Kuszynski, C., Reddy, J. Detection of autoreactive CD4 T cells using major histocompatibility complex class II dextramers. BMC Immunol. 12, 1471-2172 (2011).
  9. Batard, P., et al. Dextramers: new generation of fluorescent MHC class I/peptide multimers for visualization of antigen-specific CD8+ T cells. J Immunol Methods. 310 (1-2), 136-148 (2006).
  10. Massilamany, C., Gangaplara, A., Jia, T., et al. Direct staining with major histocompatibility complex class II dextramers permits detection of antigen-specific, autoreactive CD4 T cells in situ. PLoS One. 9 (1), (2014).
  11. Massilamany, C., Khalilzad-Sharghi, V., Gangaplara, A., Steffen, D., Othman, S. F., Reddy, J. Noninvasive Assessment of Cardiac Abnormalities in Experimental Autoimmune Myocarditis by Magnetic Resonance Microscopy Imaging in the Mouse. J Vis Exp. (88), e51654 (2014).
  12. Massilamany, C., Steffen, D., Reddy, J. An epitope from Acanthamoeba castellanii that cross-react with proteolipid protein 139-151-reactive T cells induces autoimmune encephalomyelitis in SJL mice. J Neuroimmunol. 219 (1-2), 17-24 (2010).
  13. Donermeyer, D. L., Beisel, K. W., Allen, P. M., Smith, S. C. Myocarditis-inducing epitope of myosin binds constitutively and stably to I-Ak on antigen-presenting cells in the heart. J Exp Med. 182 (5), 1291-1300 (1995).
  14. Liao, L., Sindhwani, R., Leinwand, L., Diamond, B., Factor, S. Cardiac alpha-myosin heavy chains differ in their induction of myocarditis. Identification of pathogenic epitopes. J Clin Invest. 92 (6), 2877-2882 (1993).
  15. Cameron, T. O., Cochran, J. R., Yassine-Diab, B., Sekaly, R. P., Stern, L. J. Cutting edge: detection of antigen-specific CD4+ T cells by HLA-DR1 oligomers is dependent on the T cell activation state. J Immunol. 166 (2), 741-745 (2001).
  16. Novak, E. J., et al. Activated human epitope-specific T cells identified by class II tetramers reside within a CD4high, proliferating subset. Int Immunol. 13 (6), 799-806 (2001).
  17. Reddy, J., et al. Detection of autoreactive myelin proteolipid protein 139-151-specific T cells by using MHC II (IAs) tetramers. J Immunol. 170 (2), 870-877 (2003).
  18. Skinner, P. J., Daniels, M. A., Schmidt, C. S., Jameson, S. C., Haase, A. T. Cutting edge: In situ tetramer staining of antigen-specific T cells in tissues. J Immunol. 165 (2), 613-617 (2000).
  19. Skinner, P. J., Haase, A. T. In situ tetramer staining. J Immunol Methods. 268 (1), 29-34 (2002).
  20. Skinner, P. J., Haase, A. T. In situ staining using MHC class I tetramers. Curr Protoc Immunol. Chapter 17, Unit 17.14.11 (2004).
check_url/fr/51679?article_type=t

Play Video

Citer Cet Article
Massilamany, C., Gangaplara, A., Jia, T., Elowsky, C., Li, Q., Zhou, Y., Reddy, J. In Situ Detection of Autoreactive CD4 T Cells in Brain and Heart Using Major Histocompatibility Complex Class II Dextramers. J. Vis. Exp. (90), e51679, doi:10.3791/51679 (2014).

View Video