Microperfusione Tecnica per Indagare regolamento di microvasi permeabilità a Rat mesentere

Published: September 12, 2015
doi:

Summary

The modified Landis technique enables paired measurement of the hydraulic conductivity of individual microvessels in the mesentery of normal and genetically modified rats under control and test conditions using microperfusion techniques. It provides a convenient method to evaluate mechanisms that regulate microvessel permeability and transvascular exchange under physiological conditions.

Abstract

Gli esperimenti per misurare le proprietà di permeabilità dei microvasi irrorati individualmente forniscono un ponte tra studio dei meccanismi molecolari e cellulari che regolano la permeabilità vascolare in coltura monostrato di cellule endoteliali e le proprietà di scambio funzionali di interi letti microvascolari. Un metodo per cannulare e perfusione microvasi venulari di ratto mesentere e misurare la conduttività idraulica della parete dei microvasi è descritta. Le principali attrezzature necessarie include un microscopio intravitale con un grande palco modificato che supporta micromanipolatori di posizionare tre differenti microtools: (1) una micropipetta di vetro smussato a cannulare e perfusione microrecipiente; (2) un vetro micro-occlusore per bloccare transitoriamente perfusione e consentire la misurazione di transvascular movimento flusso d'acqua ad una pressione idrostatica misurata, e (3) una bacchetta di vetro smussato per stabilizzare il tessuto mesenterico nel sito di incannulamento. Il Landis micro-occlusione techniq modificatoue utilizza globuli rossi sospese nel perfusato artificiale come marcatori di fluido movimento transvascular, e consente inoltre misurazioni ripetute di questi flussi condizioni sperimentali sono cambiati e differenza idrostatica e colloide pressione osmotica attraverso i microvasi sono attentamente controllati. Le misurazioni della conducibilità idraulica prima con un perfusato controllo, quindi dopo la ri-incannulamento della stessa microvasi con i perfusates prova consentono confronti della risposta dei microvasi in queste condizioni ben controllate associati. I tentativi di estendere il metodo per microvasi nel mesentere di topi con modificazioni genetiche che si prevede di modificare la permeabilità vascolare erano fortemente limitata a causa dell'assenza di lunghi microvasi dritti e ramificati nel mesentere del mouse, ma la recente disponibilità dei ratti con modificazioni genetiche simili utilizzando la tecnologia / Cas9 CRISPR è prevista l'apertura di nuove aree di indagine in cui possono essere applicati i metodi qui descritti. </p>

Introduction

Microperfusione nella vascolatura comporta istituisce controllato flusso di perfusato artificiale di composizione nota mediante una micropipetta in un vaso sanguigno di solito meno di 40 micron di diametro. Il vaso perfuso rimane nel suo ambiente tessuto normale e viene perfuso con dell'animale sangue fino al momento della cannulazione. Quando utilizzato in combinazione con una serie di video di immagini o di tecniche fluorimetrica, in situ microperfusione consente la misurazione dei flussi idrici e dei soluti attraverso le pareti dei microvasi in condizioni quali siano note le forze trainanti di questi flussi e le proprietà di permeabilità della parete vascolare può essere direttamente valutati. Inoltre, controllando la composizione del fluido circostante microrecipiente nel tessuto (perfusato e superfusate), la regolazione della permeabilità microvascolare e di scambio può essere indagata attivando le cellule endoteliali formano la parete microrecipiente essere esposti a una varietà di econdizioni Xperimental (agonisti, le condizioni di perfusione modificate, indicatori fluorescenti per misurare la composizione intracellulare e di segnalazione) per periodi misurati con precisione di tempo (sec a hr). Inoltre, le valutazioni ultrastrutturali o citochimici di chiave strutture molecolari cellulari che regolano la barriera possono essere studiate nelle stesse microrecipienti in cui la permeabilità viene misurata direttamente. L'approccio costituisce così un ponte tra studio dei meccanismi cellulari e molecolari di modificare la funzione di barriera endoteliale in coltura monostrato di cellule endoteliali e indagine microvasi intatti. Vedere le seguenti recensioni per un'ulteriore valutazione 1-6.

Una limitazione di microperfusione è che può essere utilizzato solo in letti microvascolari che sono sottili, trasparenti e con integrità strutturale sufficiente a consentire incannulazione con una micropipetta di vetro. Mentre i primi accertamenti utilizzati microvasi rana in mesenterio e sottile cutanea pectoris muscle 7,8, di gran lunga la preparazione più comunemente usato nei modelli di mammiferi è il topo mesentere 9-15. La maggior parte delle indagini si sono concentrate sui cambiamenti acuti in permeabilità vascolare studiato per periodi di 1-4 ore, ma le indagini più recenti sono state estese a misurazioni su singoli pescherecci 24-72 ore dopo un iniziale perfusione 12,16. La tecnologia CRISPR recentemente sviluppato, che promette di rendere più modelli di ratto geneticamente modificati per lo studio vascolare regolazione della permeabilità 17 dovrebbe consentire i metodi descritti nella presente comunicazione da applicare in microvasi venulari del mesentere di questi nuovi importanti modelli di ratto.

Il metodo richiede un microscopio rovesciato dotato di un palco microscopio su misura sufficientemente grande per contenere sia la preparazione degli animali e almeno tre micromanipolatori utilizzato per posizionare microtools vicino alla nave perfuso e per allineare una micropipetta perfusione con la navelumen. Ad esempio una piattaforma personalizzata per un palco microscopio xy (circa 90 × 60 cm) può essere fabbricata da una piastra di acciaio dello spessore di 1 cm con un rivestimento antiruggine. Lo stadio è collegato a una tabella indice ingegneria o due slitte a coda di rondine montate ad angolo retto e supportati su pilastri teflon o trasferimenti a sfere per il movimento nel piano orizzontale. Un impianto tipico (vedi figura 2) ha molto in comune con il microscopio e microposizionamento attrezzature utilizzate per una serie di esperimenti microcircolazione intravitale come quelli per misurare il flusso unico dei vasi sanguigni e dell'ematocrito, il trasporto di ossigeno locale sangue perfusione microvasi, regolazione di vascolare liscio il tono muscolare, e l'accumulo microvascolare locale dei traccianti fluorescenti iniettate nel suo complesso circolazione. 18-26

L'aspetto fondamentale della tecnica è la misura della portata (J v) attraverso una superficie definita (S) della parete microvascolare. Realizzarequesto tramite la tecnica Landis modificato qui descritta una semplice microscopio invertito è adeguata. Una piccola videocamera è montata sulla porta immagine e il segnale video, con una base tempo aggiunto, viene visualizzato su un monitor video e registrate in forma digitale su un computer o un segnale digitale o analogico su un videoregistratore. Una volta microrecipiente si incannula la porzione di microvasi visibile alla telecamera può essere modificato spostando la fase e manipolatori come unità senza interrompere la cannulazione.

Misurazione dei flussi transvascular può anche essere combinato con indagini più dettagliate utilizzando un sofisticato microscopio a fluorescenza con filtri appropriati, quali impianti utilizzati per la misurazione di soluto permeabilità, controllo rapporto fluorescente di calcio citoplasmatico o di altri meccanismi cellulari, e confocale 6,12,13, 27. Un vantaggio fondamentale di tutti gli approcci microperfusione è la capacità di fare misure ripetute, sulla nave, Sotto cambiamento controllato di forza motrice, come pressioni idrostatiche e oncotica, o cambiamento indotto nella risposta dei vasi alle condizioni infiammatorie. Il tipo più comune è un confronto accoppiato di conduttività idraulica misurata (L p) sulla nave con il vaso prima perfuso con una micropipetta riempito con un perfusato controllo e sospensione di eritrociti per stabilire uno stato basale permeabilità, quindi con una seconda pipetta con l'agente di test aggiunto perfusato. Molteplici cannulazioni sono possibili con il ciclo ripetuto dopo riperfusione con la pipetta di controllo.

Il presente protocollo dimostra la cannulazione e microperfusione di un vaso venulare nel ratto mesentere registrare flussi di acqua attraverso la parete microvessel e misurare la L p della parete del vaso, un indice utile della permeabilità del percorso comune per l'acqua e soluti attraverso intatto barriera endoteliale. La procedura si chiama techniq Landis modificatoue perché il principio originale Landis di utilizzare il movimento relativo dei globuli rossi come misura di scambio fluido transvascular dopo perfusione è bloccato è conservato 28, ma la gamma di condizioni sperimentali (ad esempio, le differenze di pressione oncotica idrostatica e albumina attraverso la parete microrecipiente) disponibile dopo microperfusione è di gran lunga maggiore rispetto al sangue perfuso uncannulated microvasi 8,29.

Protocol

Etica Dichiarazione: Tutte le procedure sono stati esaminati e approvati dal Comitato di cura e l'uso degli animali istituzionale. 1. Fabbricazione preliminare di Micropipette, la limitazione dei movimenti, e bloccanti Estrarre diversi tubi capillari di vetro borosilicato pulite in metà con un estrattore elettronico regolato in modo che, quando viene tirato, la porzione allungata del tubo è di circa 1 cm di lunghezza e le due metà sono piuttosto simmetriche. Assicurarsi che…

Representative Results

La Figura 4 mostra i risultati di misurazione del decorso temporale delle variazioni di L p in un ratto venulare microvasi cannulato successivamente con quattro perfusates. 33 L'entità di L p calcolata a pressione costante è stato usato come una misura delle variazioni di microvasi permeabilità della parete, prima nello stato di controllo con un perfusato contenente 1% di albumina sierica bovina poi, quando la nave è stata esposta per la bradichinina agente infia…

Discussion

Dettagli dei calcoli p L. Anche se il movimento fluido transvascular si verifica mentre la nave è liberamente perfuso, tale scambio è troppo piccolo per essere misurato durante la perfusione libero perché è in genere inferiore allo 0,01% del tasso di perfusione nave. Tuttavia, in condizioni di perfusione viene transitoriamente fermato occludendo microrecipiente, flusso transvascular (cioè, filtrazione) è misurata dal movimento dei globuli rossi marcatori nel lume della colonna di fluid…

Divulgations

The authors have nothing to disclose.

Acknowledgements

Questo lavoro è stato sostenuto dal National Institutes of Health sovvenzioni HL44485 e HL28607.

Materials

MICROSCOPE, TABLE AND STAGE
inverted microscope (metallurgical type) with trinocular head for video: example Olympus CK-40 try to place eyepieces higher relative to stage–you have to look through eyepieces while reaching around to top of stage over intervening micromanipulators
inverted microscope (metallurgical type) with trinocular head for video: example Leica DMIL try to place eyepieces higher relative to stage–you have to look through eyepieces while reaching around to top of stage over intervening micromanipulators
narrow diameter, long working distance objective: example Nikon Nikon E Plan 10×/0.25 LWD
stage platform–1/2 inch or 1 cm sheet steel welding shop this should be heavy to reduce vibration
Unislide x-y table: dove tail slides Velmex AXY4006W1
VIDEO
CCD video camera: example Pulnix TM-7CN (no longer available) no color needed
video capture system with audio–generic
video playback system (completely still frame, single frame motion)
small microphone
MICROMANIPULATORS, HOLDERS
micromanipulator, XYZ (3) Prior/Stoelting (no longer available) look for fine Z, and larger range of travel in coarse drives for ease of positioning
hydraulic probe drive, one way FHC 50-12-1C need to buy either manual drive or electronic drive
manual drum drive  FHC 50-12-9-02
or hydraulic drive, 3 way Siskiyou Corporation MX610 (1-way) or MX630 (3-way) great for short arms, water filled and must be sent back for refill ~every 2 years
connectors/rods/holders Siskiyou Corporation MXC-2.5, MXB etc.
pin vise Starrett 162C to hold restrainer
pipette holder World Prescision Instruments MPH3
water manometer ~120 cm
MICROSCOPE TRAY
clear Plexiglas for microscope tray for animal
3/4 inch polished quartz disc ~1/4 inch tall Quartz Scientific Inc. custom  (or polished plexiglass, glass); make sure the height is less than working distance of objective
Plexiglas glue (Weld-on 4: CAUTION CARCINOGEN)
medical adhesive for tissue well NuSil MED-1037
All-purpose silicone rubber heat mat, 5" L x 2" W Cole Parmer EW-03125-20 heater for microscope tray–needs cord and controller–240V version available
Power Cord Adapter for Kapton Heaters and Kits, 6 ft, 120 VAC Cole Parmer EW-03122-75
STACO 3PN1010B Variable-Voltage Controller, 10 A; 120 V In, 0-140 V Out Cole Parmer EW-01575-00
PIPET MANUFACTURE
vertical pipette puller Sutter Instrument Company P-30 with nichrome filament
1.5 mm OD thin wall capillary tubing Sutter Instrument Company B150-110-10
pipette grinder air stone and dissection microscope–see reference in text or purchase a package from Sutter Instruments or World Precision Instruments
RX Honing Machine, System II RX Honing Machine Corporation MAC-10700 Rx System II Machine alternative for air stone, use with a dissecting microscope mounted at an angle
   with ceramic sharpening disc RX Honing Machine Corporation use "as is" or attach lapping film
lapping film sheets, 0.3 or 0.5 um 3M part no. 051144 80827 268X Imperial lapping film sheets with adhesive back–can be purchased from Amazon

References

  1. Curry, F. R. Permeability measurements in an individually perfused capillary: the ‘squid axon’ of the microcirculation. Experimental physiology. 93, 444-446 (2008).
  2. Curry, F. R., Adamson, R. H. Vascular permeability modulation at the cell, microvessel, or whole organ level: towards closing gaps in our knowledge. Cardiovasc Res. 87, 218-229 (2010).
  3. Curry, F. R., Adamson, R. H. Tonic regulation of vascular permeability. Acta physiologica. 207, 628-649 (2013).
  4. Michel, C. C. Fluid exchange in the microcirculation. The Journal of physiology. 557, 701-702 (2004).
  5. Tarbell, J. M., Simon, S. I., Curry, F. R. Mechanosensing at the vascular interface. Annual review of biomedical engineering. 16, 505-532 (2014).
  6. Sarelius, I. H., Kuebel, J. M., Wang, J., Huxley, V. H. Macromolecule permeability of in situ and excised rodent skeletal muscle arterioles and venules. American journal of physiology. Heart and circulatory physiology. 290, H474-H480 (2006).
  7. Curry, F. E., Frokjaer-Jensen, J. Water flow across the walls of single muscle capillaries in the frog, Rana pipiens. The Journal of physiology. 350, 293-307 (1984).
  8. Michel, C. C., Mason, J. C., Curry, F. E., Tooke, J. E., Hunter, P. J. A development of the Landis technique for measuring the filtration coefficient of individual capillaries in the frog mesentery. Q J Exp Physiol Cogn Med Sci. 59, 283-309 (1974).
  9. Adamson, R. H., Zeng, M., Adamson, G. N., Lenz, J. F., Curry, F. E. PAF- and bradykinin-induced hyperpermeability of rat venules is independent of actin-myosin contraction. American journal of physiology, Heart and circulatory physiology. 285, H406-H417 (2003).
  10. Huxley, V. H., Rumbaut, R. E. The microvasculature as a dynamic regulator of volume and solute exchange. Clinical and experimental pharmacology, & physiology. 27, 847-854 (2000).
  11. Rumbaut, R. E., Wang, J., Huxley, V. H. Differential effects of L-NAME on rat venular hydraulic conductivity. American journal of physiology, Heart and circulatory physiology. , 279-H2023 (2000).
  12. Yuan, D., He, P. Vascular remodeling alters adhesion protein and cytoskeleton reactions to inflammatory stimuli resulting in enhanced permeability increases in rat venules. Journal of applied physiology. 113, 1110-1120 (2012).
  13. Zhou, X., He, P. Temporal and spatial correlation of platelet-activating factor-induced increases in endothelial [Ca(2)(+)]i, nitric oxide, and gap formation in intact venules. American journal of physiology, Heart and circulatory physiology. 301, H1788-H1797 (2011).
  14. Adamson, R. H., et al. Oncotic pressures opposing filtration across non-fenestrated rat microvessels. The Journal of physiology. 557, 889-907 (2004).
  15. Adamson, R. H., et al. Epac/Rap1 pathway regulates microvascular hyperpermeability induced by PAF in rat mesentery. American journal of physiology, Heart and circulatory physiology. 294, H1188-H1196 (2008).
  16. Curry, F. E., Zeng, M., Adamson, R. H. Thrombin increases permeability only in venules exposed to inflammatory conditions. American journal of physiology, Heart and circulatory physiology. 294, H1188-H1196 (2003).
  17. Sander, J. D., Joung, J. K. CRISPR-Cas systems for editing, regulating and targeting genomes. Nature. 32, 347-355 (2014).
  18. Bagher, P., Davis, M. J., Segal, S. S. Intravital macrozoom imaging and automated analysis of endothelial cell calcium signals coincident with arteriolar dilation in Cx40(BAC) -GCaMP2 transgenic mice. Microcirculation. 18, 331-338 (2011).
  19. Duza, T., Sarelius, I. H. Increase in endothelial cell Ca(2+) in response to mouse cremaster muscle contraction. The Journal of physiology. 555, 459-469 (2004).
  20. Oshiro, H., et al. L-type calcium channel blockers modulate the microvascular hyperpermeability induced by platelet-activating factor in vivo. Journal of vascular surgery. 22, 732-739 (1995).
  21. Chen, W., et al. Atrial natriuretic peptide-mediated inhibition of microcirculatory endothelial Ca2+ and permeability response to histamine involves cGMP-dependent protein kinase I and TRPC6 channels. Arteriosclerosis, thrombosis, and vascular biology. 33, 2121-2129 (2013).
  22. Harris, N. R., Whitt, S. P., Zilberberg, J., Alexander, J. S., Rumbaut, R. E. Extravascular transport of fluorescently labeled albumins in the rat mesentery. Microcirculation. 9, 177-187 (2002).
  23. Yuan, W., Li, G., Zeng, M., Fu, B. M. Modulation of the blood-brain barrier permeability by plasma glycoprotein orosomucoid. Microvascular research. 80, 148-157 (2010).
  24. Sugiura, Y., Morikawa, T., Takenouchi, T., Suematsu, M., Kajimura, M. Cilostazol strengthens the endothelial barrier of postcapillary venules from the rat mesentery in situ. Phlebology / Venous Forum of the Royal Society of Medicine. 29, 594-599 (2014).
  25. Guo, M., et al. Fibrinogen-gamma C-terminal fragments induce endothelial barrier dysfunction and microvascular leak via integrin-mediated and RhoA-dependent mechanism. Arteriosclerosis, thrombosis, and vascular biology. 29, 394-400 (2009).
  26. Dewar, A. M., Clark, R. A., Singer, A. J., Frame, M. D. Curcumin mediates both dilation and constriction of peripheral arterioles via adrenergic receptors. The Journal of investigative dermatology. 131, 1754-1760 (2011).
  27. Lee, J. F., et al. Balance of S1P1 and S1P2 signaling regulates peripheral microvascular permeability in rat cremaster muscle vasculature. American journal of physiology, Heart and circulatory physiology. 296, H33-H42 (2009).
  28. Landis, E. M. Microinjection studies of capillary permeability. II. The relation between capillary pressure and the rate at which fluid passes through the walls of single capillaries. Am J Physiol. 82, 217-238 (1927).
  29. Curry, F. E., Huxley, V. H., Sarelius, I. H., Linden, R. J. . Techniques in cardiovascular physiology Part 1. P3/1, 1-34 (1983).
  30. Vurek, G. G., Bennett, C. M., Jamison, R. L., Troy, J. L. An air-driven micropipette sharpener). J Appl Physiol. 22, 191-192 (1967).
  31. Curry, F. E., Clark, J. F., Adamson, R. H. Erythrocyte-derived sphingosine-1-phosphate stabilizes basal hydraulic conductivity and solute permeability in rat microvessels. American journal of physiology, Heart and circulatory physiology. 303, H825-H834 (2012).
  32. Bagher, P., Polo-Parada, L., Segal, S. S. Microiontophoresis and micromanipulation for intravital fluorescence imaging of the microcirculation. Journal of visualized experiments : JoVE. , (2011).
  33. Adamson, R. H., et al. Attenuation by sphingosine-1-phosphate of rat microvessel acute permeability response to bradykinin is rapidly reversible. American journal of physiology, Heart and circulatory physiology. 302, H1929-H1935 (2012).
  34. Bates, D. O. Vascular endothelial growth factors and vascular permeability. Cardiovasc Res. 87, 262-271 (2010).
  35. Adamson, R. H., et al. Rho and rho kinase modulation of barrier properties: cultured endothelial cells and intact microvessels of rats and mice. The Journal of physiology. 539, 295-308 (2002).
  36. Curry, F. R., et al. Atrial natriuretic peptide modulation of albumin clearance and contrast agent permeability in mouse skeletal muscle and skin: role in regulation of plasma volume. The Journal of physiology. 588, 325-339 (2010).
  37. Neal, C. R., Bates, D. O. Measurement of hydraulic conductivity of single perfused Rana mesenteric microvessels between periods of controlled shear stress. The Journal of physiology. 543, 947-957 (2002).
  38. Adamson, R. H., et al. Albumin modulates S1P delivery from red blood cells in perfused microvessels: mechanism of the protein effect. American journal of physiology, Heart and circulatory physiology. 306, H1011-H1017 (2014).
  39. Huxley, V. H., Wang, J. J., Sarelius, I. H. Adaptation of coronary microvascular exchange in arterioles and venules to exercise training and a role for sex in determining permeability responses. American journal of physiology, Heart and circulatory physiology. 293, H1196-H1205 (2007).
  40. Huxley, V. H., Williams, D. A. Basal and adenosine-mediated protein flux from isolated coronary arterioles. Am J Physiol. 271, H1099-H1108 (1996).
  41. Davis, M. J., Gore, R. W. Double-barrel pipette system for microinjection. Am J Physiol. 253, H965-H967 (1987).
  42. Adamson, R. H., et al. Sphingosine-1-phosphate modulation of basal permeability and acute inflammatory responses in rat venular microvessels. Cardiovasc Res. 88, 344-351 (2010).
  43. Zeng, Y., Adamson, R. H., Curry, F. R., Tarbell, J. M. Sphingosine-1-phosphate protects endothelial glycocalyx by inhibiting syndecan-1 shedding. American journal of physiology, Heart and circulatory physiology. , H306-H363 (2014).
check_url/fr/53210?article_type=t

Play Video

Citer Cet Article
Curry, F. E., Clark, J. F., Adamson, R. H. Microperfusion Technique to Investigate Regulation of Microvessel Permeability in Rat Mesentery. J. Vis. Exp. (103), e53210, doi:10.3791/53210 (2015).

View Video