Dynamic measurement of chloride ions is presented. Transition time of an Ag/AgCl electrode, during a chronopotentiometric technique, can give the concentration of chloride ions in electrolyte. This method does not require a stable conventional reference electrode.

Abstract

This protocol describes the dynamic measurement of chloride ions using the transition time of a silver silver chloride (Ag/AgCl) electrode. Silver silver chloride electrode is used extensively for potentiometric measurement of chloride ions concentration in electrolyte. In this measurement, long-term and continuous monitoring is limited due to the inherent drift and the requirement of a stable reference electrode. We utilized the chronopotentiometric approach to minimize drift and avoid the use of a conventional reference electrode. A galvanostatic pulse is applied to an Ag/AgCl electrode which initiates a faradic reaction depleting the Clˉ ions near the electrode surface. The transition time, which is the time to completely deplete the ions near the electrode surface, is a function of the ion concentration, given by the Nernst equation. The square root of the transition time is in linear relation to the chloride ion concentration. Drift of the response over two weeks is negligible (59 µM/day) when measuring 1 mM [Clˉ]using a current pulse of 10 Am-2. This is a dynamic measurement where the moment of transition time determines the response and thus is independent of the absolute potential. Any metal wire can be used as a pseudo-reference electrode, making this approach feasible for long-term measurement inside concrete structures.

Introduction

è presentato un sensore ione cloruro basato sulla misura del tempo di transizione di un elettrodo Ag / AgCl. Lo scopo è quello di evitare le derive inerenti durante il monitoraggio continuo a lungo termine degli ioni cloruro nel elettrolita. misura Chronopotentiometric, che è un metodo di misurazione dinamica, di un elettrodo Ag / AgCl viene utilizzato per questo scopo. Qui un tasso di variazione del potenziale di un elettrodo Ag / AgCl è misurato durante uno stimolo (impulso galvanostatico). Il vantaggio di questo approccio è dimostrato eludendo l'elettrodo di riferimento liquido-giunzione e invece utilizzando qualsiasi filo metallico come elettrodo pseudo-riferimento, permettendo quindi la rilevazione di Cl ioni di concentrazione per lungo termine (anni) e in applicazioni situ, quali misura all'interno di strutture in calcestruzzo.

Gli ioni cloruro in strutture in calcestruzzo è una delle principali cause di degrado 1,2. Avvia corrosione puntiforme in acciaio di rinforzo di unrisultati ND nel fallimento finale della struttura 3. Pertanto, misurare ioni Cl in calcestruzzo è inevitabile prevedere il ciclo di vita di servizio e di manutenzione di una struttura di 4,5. Differenti principi di rilevamento sono stati segnalati per la misura ione cloruro nel calcestruzzo come elettrochimica 6,7, 8,9 ottica ed elettromagnetica 10,11. Tuttavia, i metodi ottici ed elettromagnetici hanno messe a punto ingombranti, sono difficili da integrare come sistema stand-alone e avere problemi con selettività 12. In tecnica elettrochimica, misurare il potenziale di un elettrodo Ag / AgCl è lo stato 6,7,13 approccio art. Nonostante i risultati promettenti, questo approccio è limitata alla misura la produzione su scala dal momento che le derive a potenziale di riferimento e di diffusione risultati potenziali goccia a dati imperfetti 14,15. Un approccio tempo di transizione basato sulla misura elettrochimica dinamica (DEM) potrebbe alleviare il problema a causa di potenzialedrift 16.

Nel DEM, la risposta di un sistema ad uno stimolo applicato è misurata 17-19. L'esempio di un tale sistema è cronopotenziometria. Qui un impulso di corrente applicata viene usato come stimolo riducono ioni vicino alla superficie dell'elettrodo e la risposta corrispondente potenziale viene misurato. Una corrente anodica ad un elettrodo Ag / AgCl inizio a una reazione faradica (Ag + Cl Figura 1 AgCl + E) con un conseguente impoverimento di ioni Cl vicino alla superficie dell'elettrodo. Il cambiamento potenziale è una funzione della corrente applicata e la concentrazione degli ioni (selettivo) in 12,20 elettrolita. Il momento questi ioni impoveriscono completamente vicino all'elettrodo superficie il tasso di variazione di potenziali aumenti rapidamente, fornendo un punto di inflessione 21. Il punto di flesso della curva di risposta potenziale-time (chronopotentiogram) mostra il tempo di transizione e può essere determinata dalmassimo della derivata prima della potenziale risposta 22. Il tempo di transizione è una caratteristica della concentrazione di ioni. Questo approccio è stato utilizzato per determinare la concentrazione di ioni diversi 17 e il pH di elettroliti 23,24. In caso di un elettrodo Ag / AgCl come elettrodo di lavoro (a cui viene applicata corrente) gli ioni dannosi per l'saranno ioni cloruro 17. Quindi misurare il suo tempo di transizione determinerà la sua concentrazione.

Protocol

1. Chip Fabrication Nota: Il chip è costituito da un elettrodo Ag / AgCl lavoro (WE), un elettrodo pseudo-riferimento Ag / AgCl (pseudo-RE) e un contro-elettrodo di platino su un chip di vetro. Il metallo d'argento viene depositato su un chip di vetro, con camera bianca standard di processi 16. Viene poi clorurato in 0.1 M FeCl 3 soluzione per 30 secondi per formare uno strato di AgCl sulla superficie. L'Ag / AgCl WE (area = 9,812 millimetri 2) si trov…

Representative Results

L'elettrodo Ag / AgCl è fabbricato su un chip di vetro (Figura 1) utilizzando un processo camera bianca standard. Il sistema di misura chronopotentiometric (Figura 2) è stato utilizzato e la risposta è stata misurata usando un potenziostato. Per osservare l'effetto della concentrazione di ioni Cl sul tempo di transizione, soluzioni contenenti 4, 5 e 6 mM di Cl ioni in 0,5 M KNO 3 sfondo sono misurate (Figura 3). La …

Discussion

Il tempo di transizione è il momento di inflessione; è teoricamente indipendente dal potenziale di riferimento cioè, l'elettrodo di riferimento. Pertanto, ogni filo metallico può essere usato come un elettrodo di pseudo-riferimento per misure di tempo di transizione. In contrasto con la misurazione potenziometrica esistente di ioni cloruro nel calcestruzzo questo metodo permette a lungo termine e la calibrazione misura libera. Inoltre, la sensibilità e la gamma di rilevazione della concentrazione posso…

Divulgations

The authors have nothing to disclose.

Acknowledgements

This work is a part of the STW project “Integral solution for sustainable construction (IS2C, Fleur van Rossem for her support during the chip fabrication, Justyna Wiedemair for the chip design and Allison Bidulock for her support during the manuscript preparation.

Materials

Platinum wire (≥99.99% trace metals) Sigma Aldrich, the Netherlands EP1330-1EA
Potassium chloride (BioXtra, ≥99.0%) Sigma Aldrich, the Netherlands P9333-500G
Potassium hydroxide (90% pure reagent grade) Sigma Aldrich, the Netherlands 484016-1KG
Ferric chloride  Sigma Aldrich, the Netherlands 451649-1G
potassium nitrate (> 99% reagent grade)  Sigma Aldrich, the Netherlands P6083-500G
Ag/AgCl liquid junction reference electrode  BASi, USA model MF-2079
VSP potentiostat Biologic Science Instruments, France VSP 300
Steel wire Microlab TU Delft
Silver wire  Sigma Aldrich, the Netherlands

References

  1. Page, C., Treadaway, K. Aspects of the electrochemistry of steel in concrete. Nature. 297, 109-115 (1982).
  2. Koleva, D. A., Hu, J., van Breugel, K., Boshkov, N., de Wit, H. Conventional and pulse cathodic protection of reinforced concrete: electrochemical approach and microstructural investigations. ECS Transactions. 1, 287-298 (2006).
  3. Montemor, M., Simoes, A., Ferreira, M. Chloride-induced corrosion on reinforcing steel: from the fundamentals to the monitoring techniques. Cement and Concrete Composites. 25, 491-502 (2003).
  4. Wegen, G., Polder, R. B., Breugel, K. V. Guideline for service life design of structural concrete: A performance based approach with regard to chloride induced corrosion. Heron. 57 (3), (2012).
  5. Yoon, I., Koenders, E. Theoretical time evolution of critical chloride content in concrete. Structural Durability & Health Monitoring. 5, 275-294 (2010).
  6. Du, R. G., Hu, R. G., Huang, R. S., Lin, C. J. In situ measurement of Cl-concentrations and pH at the reinforcing steel/concrete interface by combination sensors. Analytical Chemistry. 78, 3179-3185 (2006).
  7. Angst, U., Elsener, B., Larsen, C. K., Vennesland, &. #. 2. 1. 6. ;. Potentiometric determination of the chloride ion activity in cement based materials. Journal of Applied Electrochemistry. 40, 561-573 (2010).
  8. Laferrière, F., Inaudi, D., Kronenberg, P., Smith, I. F. A new system for early chloride detection in concrete. Smart Materials and Structures. 17, 045017 (2008).
  9. Tang, J. L., Wang, J. N. Measurement of chloride-ion concentration with long-period grating technology. Smart Materials and Structures. 16, 665 (2007).
  10. Kohri, M., Ueda, T., Mizuguchi, H. Application of a near-infrared spectroscopic technique to estimate the chloride ion content in mortar deteriorated by chloride attack and carbonation. Journal of Advanced Concrete Technology. 8, 15-25 (2010).
  11. Tripathi, S. R., Inoue, H., Hasegawa, T., Kawase, K. Non-destructive Inspection of Chloride Ion in Concrete Structures Using Attenuated Total Reflection of Millimeter Waves. Journal of Infrared, Millimeter, and Terahertz Waves. 34, 181-186 (2013).
  12. Abbas, Y., Olthuis, W., van den Berg, A. A chronopotentiometric approach for measuring chloride ion concentration. Sensors and Actuators B: Chemical. 188, 433-439 (2013).
  13. Climent-Llorca, M. A., Viqueira-Pérez, E., Lòpez-Atalaya, M. M. Embeddable Ag/AgCl sensors for in-situ monitoring chloride contents in concrete. Cement and Concrete Research. 26, 1157-1161 (1996).
  14. Myrdal, R. . The electrochemistry and characteristics of embeddable reference electrodes for concrete. , (2014).
  15. Angst, U., Vennesland, &. #. 2. 1. 6. ;., Myrdal, R. Diffusion potentials as source of error in electrochemical measurements in concrete. Materials and Structures. 42, 365-375 (2009).
  16. Abbas, Y., de Graaf, D. B., Olthuis, W., van den Berg, A. No more conventional reference electrode: Transition time for determining chloride ion concentration. Analytica Chimica Acta. 821, 81-88 (2014).
  17. Meyer, R. E., Posey, F. A., Lantz, P. M. Chronopotentiometry of the Ag− AgCl system and analysis for the chloride ion. Journal of Electroanalytical Chemistry and Interfacial Electrochemistry. 19, 99-109 (1968).
  18. Olthuis, W., Langereis, G., Bergveld, P. The metrits of differential measuring in time and space. Biocybernetics and Biomedical Engineering. 21, 5-26 (2001).
  19. Bakker, E., Bhakthavatsalam, V., Gemene, K. L. Beyond potentiometry: robust electrochemical ion sensor concepts in view of remote chemical sensing. Talanta. 75, 629-635 (2008).
  20. Olthuis, W., Bomer, J., Bergveld, P., Bos, M., Van der Linden, W. Iridium oxide as actuator material for the ISFET-based sensor-actuator system. Sensors and Actuators B: Chemical. 5, 47-52 (1991).
  21. Bergveld, P., Eijkel, J., Olthuis, W. Detection of protein concentrations with chronopotentiometry. Biosensors and Bioelectronics. 12, 905-916 (1997).
  22. Iwamoto, R. Derivative chronopotentiometry. Analytical Chemistry. 31, 1062-1065 (1959).
  23. Olthuis, W., Bergveld, P. Simplified design of the coulometric sensor-actuator system by the application of a time-dependent actuator current. Sensors and Actuators B: Chemical. 7, 479-483 (1992).
  24. Olthuis, W., Bergveld, P. Integrated coulometric sensor-actuator devices. Microchimica Acta. 121, 191-223 (1995).
  25. Bard, A. J., Faulkner, L. R. . Electrochemical methods: fundamentals and applications. , (2001).
  26. Bakker, E., Bühlmann, P., Pretsch, E. Polymer Membrane Ion-Selective Electrodes-What are the Limits? . Electroanalysis. 11, 915-933 (1999).
check_url/fr/53312?article_type=t

Play Video

Citer Cet Article
Abbas, Y., de Graaf, D. B., Olthuis, W., van den Berg, A. Dynamic Electrochemical Measurement of Chloride Ions. J. Vis. Exp. (108), e53312, doi:10.3791/53312 (2016).

View Video