Summary

Uzak-kızılötesi lazer Emisyonları ve Bunların Frekansları ölçülmesi Karakterizasyonu

Published: December 18, 2015
doi:

Summary

We describe the generation of far-infrared radiation using an optically pumped molecular laser along with the measurement of their frequencies with heterodyne techniques. The experimental system and techniques are demonstrated using difluoromethane (CH2F2) as the laser medium whose results include three new laser emissions and eight measured laser frequencies.

Abstract

Üretim ve uzak kızılötesi radyasyon sonraki ölçümü yüksek çözünürlüklü spektroskopisi, radyo astronomi ve Terahertz görüntüleme sayısız uygulamaları bulmuştur. Yaklaşık 45 yıldır, tutarlı, uzak kızılötesi radyasyon nesil optik pompalanan moleküler lazer kullanılarak gerçekleştirilmiştir. Uzak kızılötesi lazer ışınımı tespit edildiğinde, bu lazer emisyonları frekansları üç lazer heterodyne tekniği kullanılarak ölçülür. Bu teknik ile, optik olarak pompalanır molekül lazer bilinmeyen frekansı iki stabilize kızılötesi referans frekansları arasındaki fark frekansı ile karıştırılır. Bu referans frekansları bağımsız karbondioksit lazerler tarafından oluşturulan, her biri bir harici, düşük basınçlı referans hücresinden floresan sinyali kullanılarak stabilize. Bilinen ve bilinmeyen lazer frekansları arasında ortaya çıkan yendi olan çıkış spec gözlenen bir metal-yalıtkan-metal nokta temaslı diyot dedektör tarafından izlenirSpektrum analizör. Bu lazer emisyonları arasındaki yendi frekans sonradan ölçülen ve bilinmeyen uzak kızılötesi lazer frekansını hesaplamak için bilinen referans frekansları ile birleştirilir. Bu teknik ile ölçülür lazer frekansları için elde edilen bir sigma fraksiyonel belirsizlik Doğru uzak kızılötesi lazer emisyonları sıklığını belirlemek., 10 7 ± 5 parçalar genellikle diğer ölçümler için referans olarak kullanıldığı gibi, yüksek olduğu gibi, kritik Lazer manyetik rezonans kullanılarak serbest radikallerin -resolution spektroskopik incelemeleri. Bu araştırma, diflormetan, CH2F 2 bir parçası olarak, uzak-kızıl ötesi lazer ortamı olarak kullanılmıştır. Bütün sekiz uzak kızılötesi lazer frekansları 0.359 den 1,273 THz kadar frekansları ile ilk kez ölçüldü. Bu lazer emisyonu Üç Bu soruşturma sırasında keşfedilen ve CO 2 ile ilgili optimal çalışma basıncı, kutuplaşma ile raporlanır </sub> lazer ve gücünü pompa.

Introduction

Uzak kızılötesi lazer frekans ölçümü ilk hocker tarafından gerçekleştirilen ve 1967 yılında ortak çalışanlar Onlar mikrodalga sinyalinin yüksek mertebeden harmonik ile karıştırılarak direkt deşarj hidrojen siyanür lazerden 311 ve 337 mikron emisyonları için frekansları ölçüldü bir silikon diyot 1. Yüksek frekansları ölçmek için, lazer ve harmonik karıştırma cihazları bir zincir lazer harmonikler 2 üretilmesi için kullanılmıştır. Sonunda, iki lazer gerekli farkı 3,4 frekansları sentezlenmesi için seçildi (CO2), karbon dioksit stabilize. Bugün 4 THz kadar uzak kızılötesi lazer frekansları iki tarafından üretilen fark frekansı yalnızca ilk harmonik kullanarak bu teknik ile ölçülebilir CO 2 referans lazerler stabilize. Daha yüksek frekans lazer emisyonları, aynı zamanda, örneğin metanol izotopologlarının KKH 2 9 THz lazer emisyonu gibi, ikinci harmonik kullanılarak ölçülebilmektedir OH ve CH 3 </sub> 18 OH. Yıllar boyunca 5,6, lazer frekansları doğru ölçüm bilimsel deneyler 7,8 bir dizi etkiledi ve Paris'te Ağırlıklar ve Ölçüler Genel Konferansı tarafından metrelik yeni bir tanımının kabulü izin verdi 1983. 9-11

Anlatılanlar gibi Heterodin teknikleri, optik olarak pompalanır molekül lazerler tarafından oluşturulan uzak kızılötesi lazer frekansları ölçümünde son derece faydalı olmuştur. Chang ve Bridges 12 optik pompalanan moleküler lazer keşfinden beri, optik binlerce uzak kızılötesi lazer emisyonları lazer medyanın çeşitli oluşturulacak olan pompalanır. Optik bir CO2 lazerle pompalanır Örneğin, diflorometan (CH2F 2) ve bunun izotopologlarının 250 üzerinden lazer emisyonu üretir. . Onların dalga boyları yaklaşık 95.6 1714.1 um 13 arasında değişmektedir </s18 -> 15 kadar bu lazer emisyonlarının yaklaşık% 75'i birkaç spektroskopik 16 atanmış ise kendi frekansları ölçülmüş oldu.

Bu lazerler, ve bunların doğru ölçülen frekanslar, yüksek çözünürlüklü spektroskopi ilerlemesinde önemli bir rol oynamıştır. Onlar lazer gazların kızılötesi spektral çalışmalar için önemli bilgiler sağlar. Genellikle bu lazer frekansları genellikle absorpsiyon spektrumları 19 doğrudan erişilemez heyecanlı titreşim devlet kademeleri arasındaki bağlantıları sağlar, çünkü kızılötesi ve uzak kızılötesi spektrumu analizi doğrulamak için kullanılır. Onlar da lazer manyetik rezonans tekniği ile 20 geçici, kısa ömürlü serbest radikalleri araştıran çalışmalar için birincil radyasyon kaynağı olarak hizmet vermektedir. Bu son derece hassas bir teknikle, paramanyetik atomların, moleküllerin dönme ve Ro-titreşim Zeeman spektrumları ve moleküler iyonlar olabilir r ileecorded bu serbest radikaller oluşturmak için kullanılan reaksiyon, fiyat araştırma yeteneği ile birlikte incelenmiştir.

Şekil 1 'de gösterilen, bu çalışma, bir optik olarak pompalanır molekül lazer olarak, difluorometan, uzak-kızıl ötesi lazer radyasyonu oluşturmak için kullanılmıştır. Bu sistem, bir sürekli dalga (CW) CO2 lazer pompası ve uzak kızılötesi lazer boşluğunun oluşur. Uzak kızılötesi lazer boşluğuna iç ayna, boşluğun sonunda sona eren kalan pompa radyasyon saçılma önce yirmialtı yansımaları geçiyor, cilalı bakır boru aşağı CO 2 lazer radyasyonu yönlendirir. Bu nedenle, uzak kızılötesi lazer ortamı enine pompalama geometri kullanılarak heyecanlı. Lazer eylemi oluşturmak için çeşitli değişkenler bazı aynı anda ayarlanır, ve lazer radyasyonu görülmektedir kez tüm sonradan optimize edilmiştir.

Bu deneyde, uzak kızılötesi lazer radyasyonu, bir metal-insu ile izlenirlator metal (MIM) nokta temaslı diyot dedektör. MIM diyot dedektör 1969'dan beri 21 lazer frekans ölçümleri için kullanılır olmuştur lazer frekans ölçümleri ise 23, MIM diyot dedektör diyot iki veya daha fazla radyasyon kaynakları olayla arasındaki harmonik karıştırıcıdır. MİM diyot detektör, bir optik, parlak nikel tabanı 24 temas eden bir keskinleştirilmiş tungsten telden oluşur. Nikel bazlı yalıtım tabakası olan bir doğal olarak meydana gelen ince bir oksit tabakası vardır.

Başlangıçta Referans tarif edilen metot ile 27 bir lazer emisyonu tespit edildi sonra frekans üç lazer heterodin tekniği 25 kullanılarak ölçülmüştür ise, Dalgaboyu, polarizasyon, gücü ve optimum çalışma basıncı kaydedilmiştir. 4. Şekil 2 iki ek cw CO 2 referans lazerler bağımsız frekans sta sahip optik pompalanan moleküler lazer gösterirHarici, düşük basınçlı referans hücresinden 28 4.3 mikron floresan sinyalinde Kuzu daldırma kullanan bilization sistemleri. Bu yazının uzak kızılötesi lazer emisyonları yanı sıra kendi dalga boyunu tahmin ve doğru kendi sıklığını belirlemede yönteme aramak için kullanılan işlem özetlenmektedir. Üç lazer heterodin tekniği ile ilgili Özellikleri yanı sıra, çeşitli bileşenler ve sistemin çalışma parametreleri referans 4, 25-27, 29, ve 30 ile birlikte Ek Tablo A'da bulunabilir.

Protocol

Deney 1. Planlama Bu deney için F 2 CH 2 faiz lazer ortamı kullanılarak yapılan öncesinde çalışmalarını değerlendirmek için edebiyat bir araştırma yapmak. Gibi onların dalga boyu ve frekans olarak çizgileri hakkında tüm bilgilerle birlikte bilinen tüm lazer emisyonlarını belirleyin. 37 – Bilinen lazer emisyonları çeşitli araştırmalar 13,31 mevcuttur. Önceki Fourier odaklanarak lazer aracı olarak kullanılan molekülü…

Representative Results

Bahsedildiği gibi, bir uzak kızılötesi lazer emisyonu için bildirilen frekans CO2 referans laser hatlardan en az iki farklı setleri ile gerçekleştirilen en az on iki ölçümün bir ortalamasıdır. Tablo 2 kullanıldığında 235,5 um lazer emisyonu için kaydedilen veriler özetlenmektedir 9 P 04 CO 2 lazer pompası. Bu uzak kızılötesi lazer emisyonu için yendi frekans ondört bireysel ölçümler kaydedildi. 9 R 10 ve 9 P 38 CO 2…

Discussion

Bazı ek tartışma gerektiren protokolü içinde birkaç kritik adımlar vardır. Uzak kızılötesi lazer dalga boyu ölçerken adım 2.5.3 de belirtildiği gibi, bu kullanılıyor uzak kızılötesi lazer ışınımının aynı modunu sağlamak için önemlidir. Bir uzak kızılötesi lazer dalga boyu birden fazla modu (örneğin, TEM 00, vb TEM 01) lazer kavitesi içinde oluşturulabilir ve böylece uygun olarak boşluğa yakın modları dalga boyu 13,29 ölçmek …

Divulgations

The authors have nothing to disclose.

Acknowledgements

This work was supported in part by the Washington Space Grant Consortium under Award NNX10AK64H.

Materials

Vacuum pump Leybold Trivac D4A HE-175 oil; Quantity = 3
Vacuum pump Leybold Trivac D8B or D16B Fomblin Fluid; Quantity = 1 of each
Vacuum pump Leybold Trivac D25B HE-175 oil; Quantity = 1
Optical chopper with controller Stanford Research Systems SR540
Lock-in amplifier Stanford Research Systems SR830
Spectrum analyzer Agilent E4407B ESA-E Series, 9 kHz to 26.5 GHz Spectrum Analyzer
Amplifier  Miteq AFS-44 Provides amplification of signals between 2 and 18 GHz. The amplifier is powered by a Hewlett Packard triple output DC power supply, model E3630A.
Amplifier  Avantek AWL-1200B Provides amplification of signals less than 1.2 GHz.
Power supply Hewlett Packard E3630A Low voltage DC power supply for amplifier.
Power supply Glassman KL Series High voltage power supply for the CO2 lasers; Quantity = 2; negative polarity
Power supply Fluke 412B High voltage power supply used with the NIST Asymmetric HV Amp
Detector Judson Infrared Inc J10D For fluorescence cell; Quantity = 2
CO2 laser spectrum analyzer Optical Engineering  16-A Currently sold by Macken Instruments Inc.
Thermal imaging plates with UV light Optical Engineering  Primarily used for aligning the CO2 reference lasers. Currently sold by Macken Instruments Inc.
Resistors Ohmite  L225J100K 100 kW, 225 W. Between 4 to 6 resistors are used in each ballast system. Each CO2 laser has its own ballast system. Fans are used to cool the resistors.
HV relay, SPDT CII Technologies H-17 Quantity = 3; one for each CO2 laser
Amplifier  Princeton Applied Research PAR 113 Used with fluorescence cell; Quantity = 2
Oscilloscope Tektronix 2235A Similar models are also used; Quantity = 2
Oscilloscope/Differential amplifier Tektronix 7903 oscilloscope with 7A22 differential amplifier
Power meter with sensor Coherent 200 For use below 10 W.  This is the power meter shown in Figure 2.
Power meter with sensor Scientech, Inc Vector S310 For use below 30 W
Multimeter Fluke 73III Similar models are also used; Quantity = 3
Data acquisition National Instruments NI cDAQ 9174 chassis with NI 9223 input module Uses LabVIEW software
Simichrome polish Happich GmbH Polish for the Nickel base used in the MIM diode detector. Although the Nickel base can be used immediately after polishing, a 12 hour lead time is typically recommended.
Pressure gauge Wallace and Tiernan 61C-1D-0050 Series 300; for CO2 laser; Quantity = 3
Pressure gauge with controller Granville Phillips Series 375 For far-infrared laser
Zirconium Oxide felt Zircar Zirconia ZYF felt Used as a beam stop
Zirconium Oxide board Zircar Zirconia ZYZ-3 board Used as a beam stop; Quantity = 4
Teflon sheet Scientific Commodities, Inc BB96312-1248 1/32 inch thick; used for the far-infrared laser output window
Polypropylene C-Line sheet protectors 61003 used for the far-infrared laser output window
Vacuum grease Apiezon
Power supply Kepco NTC 2000 PZT power supply
PZT tube Morgan Advanced Materials 1 inch length, 1 inch outer diameter, 0.062 inch thickness, reverse polarity (positive voltage on outside); Quantity = 3
ZnSe (AR coated) II-VI Inc CO2 laser window (Quantity = 3), lens, and beam splitter (Quantity 3)
NaCl window Edmond Optics Quantity = 1
CaF window Edmond Optics Quantity = 2
Laser mirrors and gratings Hyperfine, Inc Gold-coated; includes positioning mirrors
Glass laser tubes and reference cells Allen Scientific Glass
MIM diode detector Custom Microwave, Inc
Other Other materials include magnetic bases, base plates, base clamps, XYZ translation stage, etc.

References

  1. Hocker, L. O., Javan, A., Ramachandra Rao, D., Frenkel, L., Sullivan, T. Absolute frequency measurement and spectroscopy of gas laser transitions in the far infrared. Appl. Phys. Lett. 10 (5), 147-149 (1967).
  2. Wells, J. S., Evenson, K. M., Day, G. W., Halford, D. Role of infrared frequency synthesis in metrology. Proc. IEEE. 60 (5), 621-623 (1972).
  3. Whitford, B. G., Siemsen, K. J., Riccius, H. D., Baird, K. A. New frequency measurements and techniques in the 30-THz region. IEEE Trans. Instrum. Meas. 23 (4), 535-539 (1974).
  4. Petersen, F. R., et al. Far infrared frequency synthesis with stabilized CO2 lasers: Accurate measurements of the water vapor and methyl alcohol laser frequencies. IEEE J. Quantum Elect. 11 (10), 838-843 (1975).
  5. Uranga, C., Connell, C., Borstad, G. M., Zink, L. R., Jackson, M. Discovery and frequency measurement of short-wavelength far-infrared laser emissions from optically pumped 13CD3OH and CHD2OH. Appl. Phys. B. 88 (4), 503-505 (2007).
  6. Jackson, M., Milne, J. A., Zink, L. R. Measurement of optically pumped CH318OH laser frequencies between 3 and 9 THz. IEEE J. Quantum Elect. 47 (3), 386-389 (2011).
  7. Evenson, K. M., et al. Optically pumped FIR lasers: Frequency and power measurements and laser magnetic resonance spectroscopy. IEEE J. Quantum Elect. 13 (6), 442-444 (1977).
  8. Evenson, K. M., Jennings, D. A., Petersen, F. R. Tunable far-infrared spectroscopy. Appl. Phys. Lett. 44 (6), 576-577 (1984).
  9. Evenson, K. M., et al. Speed of light from direct frequency and wavelength measurements of the methane-stabilized laser. Phys. Rev. Lett. 29 (19), 1346-1349 (1972).
  10. BIPM. . Resolution 1. , 97-98 (1983).
  11. Giacomo, P. News from the BIPM. Metrol. 20 (1), 25-30 (1984).
  12. Chang, T. Y., Bridges, T. J. Laser action at 452, 496 and 541 µm in optically pumped CH3F. Opt. Commun. 1 (9), 423-426 (1970).
  13. Douglas, N. G., Walter, H. . Millimetre and Submillimetre Wavelength Lasers: A Handbook of CW Measurements. 61, (1989).
  14. Zerbetto, S. C., Vasconcellos, E. C. C., Zink, L. R., Evenson, K. M. 12CH2F2 and 13CH2F2 far-infrared lasers: New lines and frequency measurements. Int. J. Infrared Millim. Waves. 18 (12), 2301-2306 (1997).
  15. Jackson, M., Alves, H., Holman, R., Minton, R., Zink, L. R. New cw optically pumped far-infrared laser emissions generated with a transverse or ‘zig-zag’ pumping geometry. J. Infrared, Millim., Terahertz Waves. 35 (3), 282-287 (2014).
  16. Danielewicz, E. J., Button, K. J., Inguscio, M., Strumia, F. . The optically pumped difluoromethane far-infrared laser. Reviews of Infrared and Millimeter Waves. 2, 223-250 (1983).
  17. Deroche, J. C., Benichou, E. K., Guelachvili, G., Demaison, J. Assignments of submillimeter emissions in difluoromethane pumped by 12C18O2 and 12C18O2 lasers. Int. J. Infrared Millim. Waves. 7 (10), 1653-1675 (1986).
  18. Jackson, M., Zink, L. R., McCarthy, M. C., Perez, L., Brown, J. M. The far-infrared and microwave spectra of the CH radical in the v = 1 level of the X2Π. J. Mol. Spectrosc. 247 (2), 128-139 (2008).
  19. Zhao, S., Lees, R. M. CH318OH: Assignment of FIR laser lines optically pumped in the in-plane CH3-rocking band. J. Mol. Spectrosc. 168 (1), 67-81 (1994).
  20. Evenson, K. M., Saykally, R. J., Jennings, D. A., Curl, R. F., Brown, J. M. Far infrared laser magnetic resonance. Chemical and Biochemical Applications of Lasers. 5, 95-138 (1980).
  21. Hocker, L. O., Sokoloff, D. R., Daneu, V., Szoke, A., Javan, A. Frequency mixing in the infrared and far-infrared using a metal-to-metal point contact diode. Appl. Phys. Lett. 12 (12), 401-402 (1968).
  22. Daneu, V., Sokoloff, D., Sanchez, A., Javan, A. Extension of laser harmonic-frequency mixing techniques into the 9 μ region with an infrared metal-metal point-contact diode. Appl. Phys. Lett. 15 (12), 398-400 (1969).
  23. Jennings, D. A., Evenson, K. M., Knight, D. J. E. Optical Frequency Measurements. Proc. IEEE. 74 (1), 168-179 (1986).
  24. Zink, L. R. . Highly accurate molecular constants for CO, HF, HCl, OH, NaH, MgH, and O2: Rotational transition frequencies measured with tunable far infrared radiation [thesis]. , (1986).
  25. Xu, L. -. H., et al. Methanol and the optically pumped far-infrared laser. IEEE J. Quantum Elect. 32 (3), 392-399 (1996).
  26. Jackson, M., Zink, L. R., Garrod, T. J., Petersen, S., Stokes, A., Theisen, M. The generation and frequency measurement of short-wavelength far-infrared laser emissions. IEEE J. Quantum Elect. 41 (12), 1528-1532 (2005).
  27. Jackson, M., Smith, M., Gerke, C., Barajas, J. M. Measurement of far-infrared laser frequencies from methanol isotopologues. IEEE J. Quantum Elect. 51 (4), 1500105 (2015).
  28. Freed, C., Javan, A. Standing-wave saturation resonances in the CO2 10.6 μ transitions observed in a low-pressure room-temperature absorber gas. Appl. Phys. Lett. 17 (2), 53-56 (1970).
  29. DeShano, B., Olivier, K., Cain, B., Zink, L. R., Jackson, M. Using guide wavelengths to assess far-infrared laser emissions. J. Infrared, Millim., Terahertz Waves. 36 (1), 13-30 (2015).
  30. Jackson, M., Nichols, A. J., Womack, D. R., Zink, L. R. First laser action observed from optically pumped CH317OH. IEEE J. Quantum Elect. 48 (3), 303-306 (2012).
  31. Inguscio, M., Moruzzi, G., Evenson, K. M., Jennings, D. A. A review of frequency measurements of optically pumped lasers from 0.1 to 8 THz. J. Appl. Phys. 60 (12), R161-R191 (1986).
  32. Pereira, D., et al. A review of optically pumped far-infrared laser lines from methanol isotopes. Int. J. Infrared Millim. Waves. 15 (1), 1-44 (1994).
  33. Zerbetto, S. C., Vasconcellos, E. C. C. Far infrared laser lines produced by methanol and its isotopic species: A review. Int. J. Infrared Millim. Waves. 15 (5), 889-933 (1994).
  34. Moruzzi, G., Winnewisser, B. P., Winnewisser, M., Mukhopadhyay, I., Strumia, F. . Microwave, Infrared and Laser Transitions of Methanol: Atlas of Assigned Lines from 0 to 1258 cm-1. , (1995).
  35. Weber, M. J. . Handbook of Laser Wavelengths. , (1999).
  36. De Michele, A., et al. FIR laser lines from CH3OD: A review. Int. J. Infrared Millim. Waves. 25 (5), 725-734 (2004).
  37. De Michele, A., Carelli, G., Moruzzi, G., Moretti, A. Hydrazine far-infrared laser lines and assignments: a review. J. Opt. Soc. Am. B. 22 (7), 1461-1470 (2005).
  38. Moraes, J. C. S., et al. Experimental investigation of 13CD3OH infrared transitions by means of optoacoustic spectroscopy. Int. J. Infrared Millim. Waves. 13 (11), 1801-1823 (1992).
  39. Viscovini, R. C., Scalabrin, A., Pereira, D. Infrared optoacoustic spectroscopy of 13CD3OD around the 10R and 10P CO2 laser lines. Int. J. Infrared Millim. Waves. 17 (11), 1821-1838 (1996).
  40. Maki, A. G., Chou, C. C., Evenson, K. M., Zink, L. R., Shy, J. T. Improved molecular constants and frequencies for the CO2 laser from new high-J regular and hot-band frequency measurements. J. Mol. Spectrosc. 167 (1), 211-224 (1994).
  41. Douglas, N. G., Krug, P. A. CW laser action in ethyl chloride. IEEE J. Quantum Elect. 18 (10), 1409-1410 (1982).
  42. Schwaller, P., Steffen, H., Moser, J. F., Kneubühl, F. K. Interferometry of resonator modes in submillimeter wave lasers. Appl. Opt. 6 (5), 827-829 (1967).
  43. Steffen, H., Kneubühl, F. K. Resonator interferometry of pulsed submillimeter-wave lasers. IEEE J. Quantum Elect. 4 (12), 992-1008 (1968).
  44. Whitbourn, L. B., Macfarlane, J. C., Stimson, P. A., James, B. W., Falconer, I. S. An experimental study of a cw optically pumped far infrared formic acid vapour laser. Infrared Phys. 28 (1), 7-20 (1988).
  45. Belland, P., Véron, D., Whitbourn, L. B. Mode study, beam characteristics and output power of a cw 337 μm HCN waveguide laser. J. Phys. D: Appl. Phys. 8 (18), 2113-2122 (1975).
  46. Inguscio, M., Ioli, N., Moretti, A., Strumia, F., D’Amato, F. Heterodyne of optically pumped FIR molecular lasers and direct frequency measurement of new lines. Appl. Phys. B. 40 (3), 165-169 (1986).
  47. Carelli, G., et al. CH318OH: FIR laser line frequency measurements and assignments. Infrared Phys. Technol. 35 (6), 743-755 (1994).
  48. Pearson, J. C., Müller, H. S. P., Pickett, H. M., Cohen, E. A., Drouin, B. J. Introduction to submillimeter, millimeter and microwave spectral line catalog. J. Quant. Spectrosc. Radiat. Transf. 111 (11), 1614-1616 (2010).
  49. Ehasz, E. J., Goyette, T. M., Giles, R. H., Nixon, W. E. High-resolution frequency measurements of far-infrared laser lines. IEEE J. Quantum Elect. 46 (4), 474-477 (2010).
  50. Pearson, J. C., Drouin, B. J., Yu, S., Gupta, H. Microwave spectroscopy of methanol between 2.48 and 2.77 THz. J. Opt. Soc. Am. B. 28 (10), 2549-2577 (2011).
  51. Consolino, L., et al. Phase-locking to a free-space terahertz comb for metrological-grade terahertz lasers. Nat. Commun. 3, Article No. 1040 (2012).
  52. Bartalini, S., et al. Frequency-comb-assisted terahertz quantum cascade laser spectroscopy. Phys. Rev. X. 4 (2), 021006 (2014).
  53. Finneran, I. A., Good, J. T., Holland, D. B., Carroll, P. B., Allodi, M. A., Blake, G. A. Decade-spanning high-precision terahertz frequency comb. Phys. Rev. Lett. 114 (16), Article No. 163902 (2015).
  54. De Natale, P., et al. Quantum cascade laser THz metrology. Proc. SPIE.. , 93701D (2015).
  55. Dickinson, J. C., Goyette, T. M., Waldman, J. . High resolution imaging using 325 GHz and 1.5 THz transceivers. , 373-380 (2004).
  56. Vasconcellos, E. C. C., Zerbetto, S. C., Holecek, J. C., Evenson, K. M. Short-wavelength far-infrared laser cavity yielding new lines in methanol. Opt. Lett. 20 (12), 1392-1393 (1995).
check_url/fr/53399?article_type=t

Play Video

Citer Cet Article
Jackson, M., Zink, L. R. Characterizing Far-infrared Laser Emissions and the Measurement of Their Frequencies. J. Vis. Exp. (106), e53399, doi:10.3791/53399 (2015).

View Video