Single Cell Sampling Using Micromanipulation: A Technique to Isolate Single Cells from Cancer Cell Suspension

Published: April 30, 2023

Abstract

Source: Chen S. et al. Target Cell Pre-enrichment and Whole Genome Amplification for Single Cell Downstream Characterization. J. Vis. Exp. (2018)

This video describes the technique for isolating single cells from a pool of target cells to carry out downstream analysis. In this method, a micromanipulator fitted to a microscope is used for high-precision isolation of a single target cell.

Protocol

1. Single-cell Sampling

  1. Micromanipulation
    NOTE: To allow downstream applications like whole-genome analysis (WGA), isolated single cells will be added to 2 µL of cell lysis master mix. Prepare a master mix according to the number of cells to be processed. Calculate extra volumes for loss due to pipetting and place cell lysis master mix on ice.
    1. Prepare cell lysis master mix (components of WGA kit, Table of Materials and Reagents). Briefly, mix 2.0 µL of reaction buffer, 1.3 µL of octylphenoxypolyethoxyethanol (10% solution), 1.3 µL of 4-(1,1,3,3-tetramethylbutyl) phenyl-polyethylene glycol (10% solution), 2.6 µL of a proteinase K solution, and 12.8 µL RNase/DNase-free water to obtain a master mix for 10 samples (total volume 20 µL).
      NOTE: For more samples, increase the volumes accordingly.      
    2. Use a grease pen to draw an area holding the cell suspension in place. Adjust area and volume if the cell density is too high (i.e., mark a larger area on the glass slide, load 1x PBS and an aliquot of the cell suspension).
    3. Pipette the entire target cell suspension onto the glass slide.
    4. Transfer the glass slide to a microscope equipped with a micromanipulator. Let the cells settle for 5 min.
    5. Prepare 0.2 mL PCR tubes loaded with 2.0 µL of cell lysis master mix (prepared in step 1.1.1.) and store it on ice.
    6. Collect single cells in 1 µL of 1x PBS using the micromanipulator and transfer the cells into a tube containing cell lysis master mix.
      NOTE: For transferring micromanipulated cells into the cell lysis buffer, place the capillary directly into the 2 µL of lysis solution and eject until bubbles can be seen.
    7. Briefly spin down the sample at 2000 x g for 3 s using a desktop microfuge to collect all liquid at the bottom of the tube. Place the samples on ice.

Divulgazioni

The authors have nothing to disclose.

Materials

Phosphate Buffered Saline (1x PBS)  Thermo Fisher Scientific  10010-015
Vacutainer EDTA (or Na-heparin) tubes    BD 366450 (or 366480) Used as reaction tube for ex vivo capture of target cells
Pasteur pipettes 150 mm    Volac D810 Used for the low-volume application of cells to the C&R
Grease pen   Dako S2002 Used on glass slides to hold cell suspension in place
Axiovert M200 equipped with Mikromanipulator MMJ and CellTram vario   Zeiss/Eppendorf Use micromanipulation at hand
Microcapillaries (25 µm in diameter), CustomTip Type I    Eppendorf 930001201 Used for micromanipulating cells
0.2 mL PCR tubes  Biozym 710920
check_url/it/20396?article_type=t

Play Video

Citazione di questo articolo
Single Cell Sampling Using Micromanipulation: A Technique to Isolate Single Cells from Cancer Cell Suspension. J. Vis. Exp. (Pending Publication), e20396, doi: (2023).

View Video