In Vivo Biomechanical Testing of Nerve: A Procedure for Biomechanical Analysis of Brachial Plexus Nerve Injury in a Neonatal Pig Model

Published: April 30, 2023

Abstract

Source: Singh, A., et al. Methods for In Vivo Biomechanical Testing on Brachial Plexus in Neonatal Piglets. J. Vis. Exp. (2019).

In this video, we demonstrate the biomechanical testing of the brachial plexus nerve in a pig model to measure the threshold tensile strength of the nerve when subjected to stretching. This technique helps in determining the structural and mechanical properties of the nerve.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board. 1. Biomechanical Testing Set-up of the biomechanical testing device NOTE: A custom-built mechanical testing device was designed and fabricated to perform in vivo stretch of the brachial plexus (BP) nerve (Figure 1). Attach the base of the set-up to a cart. <l…

Representative Results

Figure 1: Details of in vivo mechanical testing device including the actuator, load cell, and clamp. Figure 2: Markers placed over the BP segments to record strains sustained by the tissue during the stretch. <p class="jove_content" fo:keep…

Divulgazioni

The authors have nothing to disclose.

Materials

Omega Subminature Tension & Compression Load Cell Omega LCM201-200N 200N load cel
Basler acA640-120uc camera Basler acA640-120uc
Feedback Linear Actuator Progressive Automations PA-14P 10" stroke, 150lb force, 15mm/s speed
Motion Tracking Software Kinovea N/A Open Source
Proramming Software – MATLAB Mathworks N/A version 2018A
Scissors Fine Science Tools Inc 14094-11 or 14060-09

Tags

check_url/it/20924?article_type=t

Play Video

Citazione di questo articolo
In Vivo Biomechanical Testing of Nerve: A Procedure for Biomechanical Analysis of Brachial Plexus Nerve Injury in a Neonatal Pig Model. J. Vis. Exp. (Pending Publication), e20924, doi: (2023).

View Video