Summary

في فيفو، عن طريق الجلد، إبرة وبناء، بصري تماسك التصوير المقطعي من الجماهير الكلى

Published: March 30, 2015
doi:

Summary

Optical coherence tomography (OCT) is a high resolution imaging technique that allows analysis of tissue specific optical properties providing the means for tissue differentiation. We developed needle based OCT, providing real-time imaging combined with on-the-spot tumor differentiation. This publication describes a method for percutaneous, needle based OCT of renal masses.

Abstract

Optical coherence tomography (OCT) is the optical equivalent of ultrasound imaging, based on the backscattering of near infrared light. OCT provides real time images with a 15 µm axial resolution at an effective tissue penetration of 2-3 mm. Within the OCT images the loss of signal intensity per millimeter of tissue penetration, the attenuation coefficient, is calculated. The attenuation coefficient is a tissue specific property, providing a quantitative parameter for tissue differentiation.

Until now, renal mass treatment decisions have been made primarily on the basis of MRI and CT imaging characteristics, age and comorbidity. However these parameters and diagnostic methods lack the finesse to truly detect the malignant potential of a renal mass. A successful core biopsy or fine needle aspiration provides objective tumor differentiation with both sensitivity and specificity in the range of 95-100%. However, a non-diagnostic rate of 10-20% overall, and even up to 30% in SRMs, is to be expected, delaying the diagnostic process due to the frequent necessity for additional biopsy procedures.

We aim to develop OCT into an optical biopsy, providing real-time imaging combined with on-the-spot tumor differentiation. This publication provides a detailed step-by-step approach for percutaneous, needle based, OCT of renal masses.

Introduction

وقد أظهرت العقود الماضية زيادة مطردة في معدل الإصابة الجماهير الكلى 1،2. حتى الآن، تم اتخاذ قرارات المعالجة الجماعية الكلى في المقام الأول على أساس التصوير بالرنين المغناطيسي والتصوير CT خصائص والعمر والاعتلال المشترك. لكن هذه الأساليب التشخيصية والمعلمات السريرية تفتقر إلى الجودة للكشف عن حقيقة إمكانات الخبيثة من كتلة الكلى. الخزعة الأساسية أو طموح إبرة بشكل جيد مع النسيج كافية لتقييم المرضية (التشخيص) يوفر موضوعي التمايز الورم مع كل من حساسية وخصوصية في حدود 95-100٪ 3. ولذلك خزعة تكتسب القبول في تقييم الجماهير الكلى المشبوهة 4،5. ومع ذلك، الخزعات دون الأنسجة كافية لإثبات التشخيص أو مع وضعها الطبيعي حمة الكلوي (غير التشخيص) تحدث بمعدل 10-20٪ بشكل عام، وحتى تصل إلى 30٪ في الجماهير الكلوية الصغيرة (<4 سم، SRMs)، وتأخير عملية التشخيص بسبب ضرورة متكررة عن إضافيةإجراءات الخزعة 3،5.

التصوير المقطعي التماسك البصري (OCT) هو طريقة التصوير الرواية التي لديها القدرة على التغلب على العقبات المذكورة في الكلوي التمايز كتلة. استنادا إلى ارتداد مبعثر من ضوء الأشعة تحت الحمراء القريب، أكتوبر توفر صورا مع 15 ميكرون القرار المحوري في لاختراق الأنسجة الفعال 2-3 مم (الشكل 1، 2). وأعرب عن فقدان كثافة إشارة في كل مليمتر من اختراق الأنسجة، وذلك كمحصلة لأنسجة محددة تشتت الضوء، ومعامل التوهين (μ أكتوبر: مم -1) كما وصفها فابر وآخرون 6. الخصائص النسيجية يمكن ربطها μ القيم أكتوبر توفير معلمة الكمية للتمايز الأنسجة (الشكل 3).

خلال التسرطن، تعرض الخلايا الخبيثة عدد متزايد، نوى أكبر حجما وأكثر غير منتظمة الشكل مع مؤشر الانكسار العالي والميتوكوندريا أكثر نشاطا. ونتيجة لهذا overexpression من مكونات الخلايا، وإحداث تغيير في μ أكتوبر هو متوقع عند مقارنة الأورام الخبيثة لأورام حميدة أو الأنسجة تتأثر 7.

مؤخرا قمنا بدراسة قدرة سطحية أكتوبر للتمييز بين الجماهير الكلى الحميدة والخبيثة 8،9. في 16 مريضا، تم الحصول على قياسات أكتوبر داخل منطوق نسيج الورم باستخدام أكتوبر التحقيق وضعت خارجيا. ذراع التحكم تتألف من القياسات أكتوبر من الأنسجة تتأثر في نفس المرضى. وأظهرت الأنسجة الطبيعية معامل التوهين متوسط ​​أقل بكثير مقارنة مع الأنسجة الخبيثة، مؤكدا إمكانية أكتوبر للورم التمايز. وقد تم تطبيق هذا التحليل الكمي بطريقة مماثلة إلى الصف أنواع أخرى من الأنسجة الخبيثة، مثل سرطان الظهارة البولية 10،11 والفرج الظهارية الأورام التمايز 12.

والأنف والحنجرة "> ونحن نهدف إلى تطوير أكتوبر إلى خزعة البصرية، وتوفير التصوير في الوقت الحقيقي جنبا إلى جنب مع على الفور للورم التمايز. والهدف من الدراسة الحالية هو وصف لعن طريق الجلد وإبر مقرها، أكتوبر النهج في تشخيص المرضى مع الصلبة تعزيز كتلة الكلى. هذا الوصف الطريقة، على حد علمنا، أول لتقييم إمكانية إبرة أكتوبر مقرها الأورام الكلوية.

Protocol

يأخذ الإجراء قدمت في ظل بروتوكول البحوث المعتمدة من قبل مجلس المراجعة المؤسسية للمركز الأكاديمي الطبي أمستردام، ورقم التسجيل NL41985.018. مطلوب الموافقة المسبقة عن خطية من جميع المشاركين. 1. النظام <li style=";text-al…

Representative Results

بين الأورام 25 الأولى (23 مريضا)، أجريت ما مجموعه 24 أكتوبر الإجراءات الناجحة. في حالة واحدة أدى عطل التحقيق لعدم القدرة على اكتساب مسح أكتوبر. اثنين من الأحداث السلبية (AE) وقعت، والتي وصفها بالتفصيل في قسم المناقشة. تم العثور على الخصائص العامة للمرضى في الجدول 1.</stron…

Discussion

في هذا المنشور نحن تقريرا عن جدوى عن طريق الجلد، إبرة استنادا اكتوبر في الكلى. وهذه خطوة أولى أساسية في تطوير أكتوبر إلى تقنية قابلة للتطبيق سريريا للورم التمايز، ووصف بأنه "خزعة البصرية". وأظهرت لدينا 25 مريضا الأول عن طريق الجلد أكتوبر ليكون الإجراء سهلة وآمنة. …

Divulgazioni

The authors have nothing to disclose.

Acknowledgements

This work is funded by the Cure for Cancer Foundation, Dutch Technology Foundation (STW) and The Netherlands Organisation for Health Research and Development (ZonMw).

Materials

15G / 7.5cm Co-Axial Introducer Needle Angiotech, Gainesville, USA MCXS1612SX
18G / 20cm Trocar Needle Cook medical, Bloomington, USA DTN-18-20.0-U
16G / 20cm Quick-Core Biopsy Gun Cook Medical, Bloomington, USA G07827
Ilumien Optis PCI Optimization System (OCT & FFR) St. Jude medical, St. Paul, USA C408650 Part of Dragonfly Kit.
St. Jude medical, St. Paul, USA. (C4088643)
Dragonfly Duo Imaging Catheter LightLab Imaging, Westford, USA C408644 Part of Dragonfly Kit.
St. Jude medical, St. Paul, USA. (C4088643)
Sterile Dock Cover CFI Med. Solutions, Fenton, USA 200-700-00 Part of Dragonfly Kit.
St. Jude medical, St. Paul, USA. (C4088643)
5ml Luer-lock Syringe Merit Med. Syst., South Jordan, USA C408647
10ml Syringe BD, Franklin Lakes, USA 300912
18G Blunt Fill Needle BD, Franklin Lakes, USA 305180
21G Injection Needle BD, Franklin Lakes, USA 301155
Sterile scalpel BD, Franklin Lakes, USA 372611
NaCl 0,9% solution Braun, Melsungen AG, Germany 222434
Lidocaïne HCl 2% (20mg/ml) solution Braun, Melsungen AG, Germany 3624480
Sterile Ultrasound Gel, Aquasonic 100 Parker Lab. Inc., Fairfield, USA GE424609
Sterile Ultrasound Cover Microtek Med., Alpharetta, USA PC1289EU
Pathology Container
AMIRA software package FEI Visualization Sciences Group, Hillsboro, USA Software platform for 3D data analysis
FIJI software package (open source) Open source, http://fiji.sc/Fiji Open source image processing software

Riferimenti

  1. Jemal, A., Siegel, R., Xu, J., Ward, E. Cancer statistics, 2010. CA Cancer J. Clin. 60, 277-300 (2010).
  2. Mathew, A., Devesa, S. S., Fraumeni, J. F., Chow, W. H. Global increases in kidney cancer incidence, 1973-1992. Eur. J. Cancer Prev. 11, 171-178 (2002).
  3. Volpe, A., et al. Contemporary management of small renal masses. Eur. Urol. 60, 501-515 (2011).
  4. Ljungberg, B., et al. EAU guidelines on renal cell carcinoma: the 2010 update. Eur. Urol. 58, 398-406 (2010).
  5. Donat, S. M., et al. Follow-up for Clinically Localized Renal Neoplasms. AUA Guideline, J. Urol. 190, 407-416 (2013).
  6. Faber, D. J., van der Meer, F. J., Aalders, M. C. G., van Leeuwen, T. G. Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography. Optics Express. 12, 4353-4365 (2004).
  7. Xie, T. Q., Zeidel, M. L., Pan, Y. T. Detection of tumorigenesis in urinary bladder with optical coherence tomography: optical characterization of morphological changes. Optics Express. 10, 1431-1443 (2002).
  8. Barwari, K., et al. Differentiation between normal renal tissue and renal tumours using functional optical coherence tomography: a phase I in vivo human study. BJU. Int. 110, E415-E420 (2012).
  9. Barwari, K., et al. Advanced diagnostics in renal mass using optical coherence tomography: a preliminary report. J. Endourol. 25, 311-315 (2011).
  10. Cauberg, E. C., et al. Quantitative measurement of attenuation coefficients of bladder biopsies using optical coherence tomography for grading urothelial carcinoma of the bladder. J. Biomed. Opt. 15, 066013 (2010).
  11. Bus, M. T., et al. Volumetric in vivo visualization of upper urinary tract tumors using optical coherence tomography: a pilot study. J. Urol. 190, 2236-2242 (2013).
  12. Wessels, R., et al. Optical coherence tomography in vulvar intraepithelial neoplasia. Journal of Biomedical Optics. 17, (2012).
  13. Yun, S. H., Tearney, G. J., de Boer, J. F., Iftimia, N., Bouma, B. E. High-speed optical frequency-domain imaging. Optics Express. 11, 2953-2963 (2003).
  14. Kodach, V. M., Kalkman, J., Faber, D. J., van Leeuwen, T. G. Quantitative comparison of the OCT imaging depth at 1300 nm and 1600 nm. Biomed. Opt. Express. 1, 176-185 (2010).
  15. Kinkelder, R., de Bruin, D. M., Verbraak, F. D., van Leeuwen, T. G., Faber, D. J. Comparison of retinal nerve fiber layer thickness measurements by spectral-domain optical coherence tomography systems using a phantom eye model. J. Biophotonics. 6, 314-320 (2013).
  16. Baxter, G. M., Sihdu, P. S. . Ultrasound of the Urogenital System. , (2006).
check_url/it/52574?article_type=t

Play Video

Citazione di questo articolo
Wagstaff, P. G., Swaan, A., Ingels, A., Zondervan, P. J., van Delden, O. M., Faber, D. J., van Leeuwen, T. G., de la Rosette, J. J., de Bruin, D. M., Laguna Pes, M. P. In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses. J. Vis. Exp. (97), e52574, doi:10.3791/52574 (2015).

View Video