Summary

विश्लेषणात्मक microfluidic उपकरणों में थर्मल मापन तकनीक

Published: June 03, 2015
doi:

Summary

Here, we present three protocols for thermal measurements in microfluidic devices.

Abstract

Thermal measurement techniques have been used for many applications such as thermal characterization of materials and chemical reaction detection. Micromachining techniques allow reduction of the thermal mass of fabricated structures and introduce the possibility to perform high sensitivity thermal measurements in the micro-scale and nano-scale devices. Combining thermal measurement techniques with microfluidic devices allows performing different analytical measurements with low sample consumption and reduced measurement time by integrating the miniaturized system on a single chip. The procedures of thermal measurement techniques for particle detection, material characterization, and chemical detection are introduced in this paper.

Introduction

तीन अलग अलग सूक्ष्म पैमाने पर थर्मल माप तकनीक इस लेख में प्रस्तुत कर रहे हैं। microfluidic उपकरणों के तीन अलग अलग विन्यास थर्मल कण का पता लगाने (टीपीडी), थर्मल लक्षण वर्णन (थर्मल चालकता और विशिष्ट गर्मी), और रासायनिक प्रतिक्रियाओं और बातचीत के उष्मापन का पता लगाने के लिए किया जाता है।

थर्मल कण का पता लगाने

का पता लगाने और microfluidic उपकरणों में कणों की गिनती व्यापक रूप से, पर्यावरण, औद्योगिक और जैविक अनुप्रयोगों 1 के लिए प्रयोग किया जाता है। टीपीडी microfluidic उपकरणों 2 में थर्मल माप के उपन्यास अनुप्रयोगों में से एक है। का पता लगाने और कण आकार के आधार पर कणों की गिनती के लिए गर्मी हस्तांतरण का उपयोग कर प्रणाली की जटिलता, लागत, और आकार कम कर देता है। अन्य विधियों, जटिल प्रकाशिकी या जटिल बिजली के माप और उन्नत सिग्नल प्रोसेसिंग सॉफ्टवेयर में कणों का पता लगाने के लिए किया जाता है।

थर्मल चारामाइक्रो-कैलोरीमीटर का प्रयोग तरल पदार्थ की cterization

तरल नमूना थर्मल लक्षण वर्णन microfluidic उपकरणों में थर्मल माप की दूसरी आवेदन है। सूक्ष्म पैमाने उष्मामिति प्रदर्शन नमूना खपत को कम करने और पारंपरिक, थोक उष्मामिति तरीकों की तुलना में अधिक है, repeatability की पेशकश के द्वारा परिशुद्धता में वृद्धि होगी। पर चिप माइक्रो कैलोरीमीटर डिवाइस का उपयोग तापीय चालकता और विशिष्ट गर्मी माप के लिए प्रक्रियाओं कहीं और 3 प्रस्तुत कर रहे हैं। थर्मल चालकता माप के लिए गर्मी पैठ समय तकनीक और microfluidic उपकरणों में विशिष्ट गर्मी मापन के लिए थर्मल लहर विश्लेषण (TWA) के विवरण प्रोटोकॉल अनुभाग में वर्णित हैं।

उष्मापन जैव रासायनिक में पता लगाने कागज आधारित microfluidic युक्ति

थर्मल माप का एक अन्य आवेदन कागज आधारित microfluidics में जैव रासायनिक पता लगाना है। में केशिका क्रियाकागज के झरझरा संरचना तरल किया जाता है और सूक्ष्म चैनलों में बुलबुला दीक्षा समस्याओं से बचा जाता है। कागज आधारित microfluidic उपकरणों में सबसे आम पता लगाने तंत्र ऑप्टिकल या विद्युत तकनीकों हैं। ऑप्टिकल पहचान उच्च जटिलता से ग्रस्त है और उन्नत इमेज प्रोसेसिंग सॉफ्टवेयर की आवश्यकता का पता चला संकेत quantize करने के लिए। वे केवल सक्रिय उपोत्पाद है कि उत्पादन प्रतिक्रियाओं के लिए लागू किया जा सकता है, क्योंकि विद्युत पता लगाने को भी सीमित कर रहे हैं। हाल ही में शुरू उष्मापन कागज आधारित जैव रासायनिक सेंसर मंच 4 कागज आधारित microfluidic प्रणाली और लेबल से मुक्त थर्मल का पता लगाने तंत्र का लाभ लेता है। एक कागज पर आधारित microfluidic मंच में ग्लूकोज oxidase (भगवान) एंजाइम का उपयोग कर ग्लूकोज की उष्मापन का पता लगाने की प्रक्रिया प्रोटोकॉल खंड में प्रस्तुत कर रहे हैं।

इस पेपर का लक्ष्य microfluidic उपकरणों में थर्मल माप तकनीक की क्षमताओं का प्रदर्शन करने के लिए है। डिवाइस preparatioएन, तरल नमूना हैंडलिंग और प्रतिरोध तापमान डिटेक्टर (सेवानिवृत्त) सेंसर उत्तेजना और माप अगले वर्गों में प्रस्तुत कर रहे हैं।

Protocol

1. थर्मल कण का पता लगाने (टीपीडी) मानक अर्धचालक प्रसंस्करण प्रौद्योगिकी 2 का उपयोग कर, micromachining द्वारा एक पतली फिल्म सिलिकॉन नाइट्राइड झिल्ली और एकीकृत तापमान संवेदक के साथ सूक्ष्म गढ़े सिलिकॉन डि?…

Representative Results

चित्रा 3 मापा थर्मल संकेत की साजिश को दर्शाता है। इसी ऑप्टिकल छवियों के साथ मोतियों की उपस्थिति में उत्पन्न संकेतों सूक्ष्म चैनल में microsphere पुनश्च मोतियों की सफल पता लगाने दिखा। सूक्ष्म चैनल के म?…

Discussion

Different thermal measurement techniques in microfluidic devices and their respective setup procedures are presented in this work. These thermal measurement methods such as thermal conductivity monitoring, thermal penetration time, amplitude of AC thermal fluctuations, and amplitude measurement of the generated heat are used to detect specific substances and investigate different reactions and interactions.

The thermal time constant plays a key role in the aforementioned thermal measurement t…

Divulgazioni

The authors have nothing to disclose.

Acknowledgements

इस काम के लिए आंशिक वित्तीय सहायता जल उपकरण और विस्कॉन्सिन-मिल्वौकी (आईआईपी-0,968,887) और Marquette विश्वविद्यालय (आईआईपी-0,968,844) के विश्वविद्यालय में स्थित नीति पर उद्योग / विश्वविद्यालय सहकारी अनुसंधान केंद्र के माध्यम से अमेरिका के राष्ट्रीय विज्ञान फाउंडेशन द्वारा प्रदान की गई थी। हम उपयोगी विचार विमर्श के लिए ग्लेन एम वाकर, वू-जिन चांग और शंकर राधाकृष्णन धन्यवाद।

Materials

Polydimethylsiloxane (PDMS)  Dow Corning Sylgard 184
PS beads – 90 um  Corpuscular 100265
PS beads – 200 um  Corpuscular 100271
Glycerol SigmaAldrich G5516
GOD enzyme SigmaAldrich G7141
Glucose Control Solution-Low Bayer contour Low Control
Glucose Control Solution-Normal Bayer contour Normal Control
Glucose Control Solution-High Bayer contour High Control
Chromatography filter paper Whatman 3001-845
Glass VWR  48393-106
Acrylic Film Nitto Denko 5600
Glass syringe (1 mL) Hamilton 1001
Syringe pump New Era NE-500
knife plotter Silhouette portrait
Current Preamplifier Stanford Research SR-570
Ocilloscope Agilent DSO 2420A
Signal Generator HP HP3324A
Lock-in Amplifire Stanford Research SRS-830
Source/meter 2400 Keithley 2400
Source/meter 2600 Keithley 2436A

Riferimenti

  1. Zhang, H., Chon, C., Pan, X., Li, D. Methods for counting particles in microfluidic applications. Microfluid Nanofluid. 7 (6), 739-749 (2009).
  2. Vutha, A. K., Davaji, B., Lee, C. H., Walker, G. M. A microfluidic device for thermal particle detection. Microfluid Nanofluid. 17 (5), 871-878 (2014).
  3. Davaji, B., Bak, H. J., Chang, W. J., Lee, C. H. A Novel On-chip Three-dimensional Micromachined Calorimeter with Fully Enclosed and Suspended Thin-film Chamber for Thermal Characterization of Liquid Samples. Biomicrofluidics. 8 (3), 034101-034113 (2014).
  4. Davaji, B., Lee, C. H. A paper-based calorimetric microfluidics platform for bio-chemical sensing. Biosens. Bioelectron. 59, 120-126 (2014).
  5. Liu, J., et al. Process research of high aspect ratio microstructure using SU-8 resist. Microsystem Technologies. 10, 265-268 (2004).
  6. Dusen, M. S. V. Platinum-resistance thermometry at low temperatures. J. Am. Chem. Soc. 47 (2), 326-332 (1925).
  7. Arpaci, V. S. . Conduction Heat Transfer. , (1966).
  8. Garden, J. L., Chteau, E., Chaussy, J. Highly sensitive ac nanocalorimeter for microliter-scale liquids or biological samples. Appl. Phys. Lett. 84, 3597-3599 (2004).
  9. Kilo, C., et al. Evaluation of a New Blood Glucose Monitoring System with Auto-Calibration. Diabetes Technol. Ther. 7 (2), 283-294 (2005).
  10. Scheper, T. . Thermal Biosensors Bioactivity Bioaffinity (Advances in Biochemical Engineering/Biotechnology). , (1999).
check_url/it/52828?article_type=t

Play Video

Citazione di questo articolo
Davaji, B., Lee, C. H. Thermal Measurement Techniques in Analytical Microfluidic Devices. J. Vis. Exp. (100), e52828, doi:10.3791/52828 (2015).

View Video