Summary

Inducendo ischemia-riperfusione lesioni in Ear pelle mouse per intravitale Multiphoton Imaging delle risposte immunitarie

Published: December 22, 2016
doi:

Summary

Questo protocollo descrive l'induzione di un modello di ischemia-riperfusione (IR) sulla pelle orecchio mouse utilizzando magnete di bloccaggio. Utilizzando un modello di imaging intravitale custom-built, studiamo in vivo risposte infiammatorie post-riperfusione. La logica alla base dello sviluppo di questa tecnica è quello di estendere la comprensione di come leucociti rispondono al danno IR pelle.

Abstract

Ischemia-reperfusion injury (IRI) occurs when there is transient hypoxia due to the obstruction of blood flow (ischemia) followed by a subsequent re-oxygenation of the tissues (reperfusion). In the skin, ischemia-reperfusion (IR) is the main contributing factor to the pathophysiology of pressure ulcers. While the cascade of events leading up to the inflammatory response has been well studied, the spatial and temporal responses of the different subsets of immune cells to an IR injury are not well understood. Existing models of IR using the clamping technique on the skin flank are highly invasive and unsuitable for studying immune responses to injury, while similar non-invasive magnet clamping studies in the skin flank are less-than-ideal for intravital imaging studies. In this protocol, we describe a robust model of non-invasive IR developed on mouse ear skin, where we aim to visualize in real-time the cellular response of immune cells after reperfusion via multiphoton intravital imaging (MP-IVM).

Introduction

danno da ischemia-riperfusione (IRI) si verifica quando vi è una ipossia transitoria causa l'ostruzione del flusso sanguigno (ischemia) seguita da una successiva riossigenazione dei tessuti (riperfusione). Nella pelle, ischemia-riperfusione (IR) è pensato per essere uno dei fattori che contribuiscono alla fisiopatologia delle ulcere da pressione, dove prolungato riposo a letto predispone i pazienti in ospedale a lungo termine per infortunio. In questi pazienti, sia la pelle ed i muscoli sottostanti sono costantemente esposti alla pressione del peso esercitato sulle aree di prominenza ossea, con conseguente lesioni localizzate che, se non trattata, può diventare necrotico 1.

I danni coinvolte in un IRI sono duplici. Durante l'ischemia, l'occlusione di vasi sanguigni porta ad un drastico calo di apporto di ossigeno ai tessuti. Ciò si traduce in una diminuzione di ATP e di pH, che inattiva ATPasi coinvolti nel metabolismo cellulare. A loro volta, i livelli di calcio cellulari picco, e ha sottolineato oc danneggiatiells apoptosi o necrosi 2. Il rilascio di contenuti intracellulari o danni associati modelli molecolari (grezzo), come HMGB1, contribuisce alla risposta infiammatoria 3. Il secondo insulto si verifica durante la riperfusione. Anche se i livelli di ossigeno e pH vengono ripristinati durante la riperfusione, ciò comporta la generazione di specie reattive dell'ossigeno (ROS), che porta alla ossidazione dei lipidi intracellulari, DNA e proteine. Di conseguenza, i mediatori pro-infiammatori sono attivati, che scatena una risposta infiammatoria secondaria che prevede il reclutamento di cellule immunitarie al sito infiammatorio 2. Mentre la cascata di eventi biochimici che portano alla risposta infiammatoria è stata ben descritta, la regolazione spaziale e temporale delle attività delle cellule immunitarie non sono ben compresi.

Qui, descriviamo un modello IR robusta sulla pelle orecchio del mouse utilizzando semplici bloccaggio magnete. Accoppiato con l'imaging intravitale multiphoton (MP-IVM), abbiamostabilito un modello per studiare le risposte infiammatorie in vivo che si verificano dopo riperfusione avviene. La logica dietro lo sviluppo e l'utilizzo di questa tecnica è quello di cercare di capire come sia cellule interstiziali e infiltranti rispondono a infrarossi in tempo reale.

Modelli esistenti di IR utilizzando la tecnica di serraggio sul fianco pelle sono altamente invasiva, in quanto richiedono l'impianto chirurgico di piastre di acciaio a fianco pelle, rendendoli meno che ideale per studi immunologici 4. Una tecnica di fissaggio non invasiva simile è stato descritto nel 5,6 topo pelle fianco. Tuttavia, a causa della incorporazione della componente di imaging intravitale in questo metodo, abbiamo invece scelto la pelle dell'orecchio come sito IR mirato, come elude movimenti dovuti alla respirazione e offre stabilità durante l'imaging 7,8. Inoltre, sottoinsiemi leucociti che abbracciano l'interstizio sono identici tra la pelle orecchio e il fianco pelle, anche se lanumeri e proporzioni possono variare leggermente 9. Così, la pelle dell'orecchio rappresenta un sito di imaging ideale.

Inoltre, la maggior parte dei dati recuperati da questi modelli IRI sono limitati a valutazioni macroscopici (classificazione delle ulcere) e le analisi microscopiche di endpoint indicatori infiammatori 10. Utilizzando questo modello, visualizzazione in tempo reale della risposta cellulare dei neutrofili dopo riperfusione nella pelle di un topo reporter fluorescente è abilitato. Un modello di imaging intravitale orecchio precedentemente pubblicato viene utilizzato 8 con ulteriori modifiche (figure 1, 2).

Protocol

Tutti gli esperimenti che si occupano di animali vivi sono stati condotti in conformità a tutte le uso animale pertinente e linee guida e regolamenti per la cura. 1. Scelta di topi reporter fluorescente Utilizzare da 6 a 12 settimane di età LysM-eGFP 11 topi (senza preferenza per maschi o femmine). Nota: L'uso di vari topi reporter fluorescente specifiche delle celle consente la visualizzazione di diverse cellule immunitarie in vivo. In questo cepp…

Representative Results

Questo protocollo utilizza una piattaforma di imaging pelle dell'orecchio su misura, come mostrato in Figura 1. Diverse caratteristiche di questa piattaforma sono progettati specificamente per facilitare l'imaging, pur mantenendo le impostazioni fisiologici. Posizionando l'orecchio sulla piattaforma ottone riscaldati non mantiene solo l'orecchio ad una temperatura fisiologica di 35 ° C, ma anche ad isolare l'orecchio da inevitabili movimenti dovuti a…

Discussion

Importanza

IR è una delle principali cause di ulcere da pressione pelle. Le fasi (I e II) di ulcere da pressione descrivono la condizione della pelle umana (rispetto ai tessuti sottocutanei sottostanti e muscoli). Tuttavia, una comprensione della eziologia immunologica è ancora carente. Qui, vi presentiamo un modello IR semplice e robusto sulla pelle orecchio mouse per colmare questa lacuna. Simuliamo ischemia fissando l'orecchio mouse tra due magneti e successivamente studiare le rispost…

Divulgazioni

The authors have nothing to disclose.

Acknowledgements

We thank Thomas Graf for providing us with the LysM-eGFP mice.

Materials

Mice strains
Lysozyme-GFP C57BL/6 Thomas Graf, Center for Genomic Regulation
C57BL/6-C2J Jackson Laboratories 000058 To be crossed with Lysozyme-GFP to generate albino Lysozyme-GFP for skin imaging
Name Company Catalog Number Comments
Reagents
PBS
Viaflex 0.9% (wt/vol) saline Baxter Healthcare F8B1323
Ketamine (100 mg ml−1 ketamine hydrochloride Parnell Ketamine is a controlled drug and all relevant local regulations should be followed
Ilium Xylazil-20 (20 mg ml−1 xylazine hydrochloride) Troy Laboratories Xylazil-20 is a controlled drug and all relevant local regulations should be followed.
Evans blue (10 mg ml−1 in PBS or saline) Sigma-Aldrich 46160
Ultrapurified water
Name Company Catalog Number Comments
Equipment
Insulin syringe with needle BD 328838
Transfer pipettes Biologix Research Company 30-0135
3M paper masking tape 3M 2214
Deckglaser microscope cover glass (22 mm × 32 mm) Paul Marienfeld 101112
Curved splinter forceps Aesculap, B. Braun Melsungen BD312R
Veet hair removal cream Reckitt Benckiser
Medical cotton-tipped applicators Puritan Medical Products Company 806-WC
C-fold towels Kimberly-Clark 20311
Kimwipes delicate task wipes Kimtech Science 34155
Gold-plated, N42-grade neodymium magnets, 12mm in diameter and 2mm thick  first4magnets F656S
Plastic guide, 10cm by 1.5cm (polyvinyl chloride material) fold in half lengthwise, bind with masking tape and slot magnet in
High vacuum grease Dow Corning
Name Company Catalog Number Comments
Microscope
TriM Scope II single-beam two-photon microscope LaVision BioTec
Tunable (680–1,080 nm) Coherent Chameleon Ultra II One Box Ti:sapphire laser (≥3.3 W at 800 nm; pulse length of 140 fs, 80 MHz repetition rate) Coherent
Water-dipping objectives (20×, NA = 1.0) Olympus XLUMPLFLN20xW
Name Company Catalog Number Comments
Miscroscope filter and mirror sets (for imaging GFP, SHG, Evans Blue)
495 long-pass Chroma T495LPXR
560 lomg-pass Chroma T560LPXR
475/42 band-pass Semrock FF01-475/42-25
525/50 band-pass Chroma ET525/50m
655/40 band-pass Chroma NC028647
Name Company Catalog Number Comments
Skin-imaging stage platform (refer to diagram for assembly)
A metal base plate (126 mm × 126 mm × 1 mm)
A brass platform for the ear (79 mm × 19 mm; 1 mm thickness at side, 0.5 mm thickness in the middle; Fig. 1) with slit (1.7 mm × 1 mm; 1.5 mm away from long edge)
Two plastic blocks (10 mm in height)—for heat insulation
Curved holder, for positioning the control thermistor on the ear platform
Interface cable CC-28 with DIN connector and thermistors, one for the temperature control and the other for the temperature monitor (Warner Instruments (Harvard Apparatus) 640106 connect the interface cable to both resistive heater blocks set at 35°C
Resistive heater blocks RH-2 (Warner Instruments (Harvard Apparatus) 640274 Resistive heater blocks can heat the brass ear platform up to over 100 °C within minutes. Ensure that the control thermistor has been properly secured in the holder in order to avoid overheating.
Temperature controller TC-344B for the ear platform (Warner Instruments (Harvard Apparatus) 640101
Temperature controller TR-200 for mouse heating pad Fine Science Tools 21052-00 Unit is no longer for sale. Ask manufacturer for alternatives
Power supply for TR-200 Fine Science Tools 21051-00 Unit is no longer for sale. Ask manufacturer for alternatives
Heating pad Fine Science Tools 21060-00 Unit is no longer for sale. Ask manufacturer for alternatives. 
Animal rectal probe  Fine Science Tools 21060-01 Unit is no longer for sale. Ask manufacturer for alternatives. After connecting the rectal probe and heating pad to the temperature controller TR-200, set the temperature to 37 °C
Name Company Catalog Number Comments
Coverslip holder
2 plastic rods, 1 cm in diameter, 10 cm in length
1 plastic adaptor with holes drilled to accommodate rods (refer to diagram)
3 plastic tightening screws for keeping plastic rods in place
1 metal plate, 6 cm x 2.5 cm, with a 2 cm square cut at 1 end, 2 mm edge away from short edge
1 pair of nut and bolt for attaching metal plate to plastic rod
1 acrylic base (4 cm x 5 cm x 1.5 cm) with magnet to hold coverslip holder on skin-imaging stage platform. 1 rod is permanently fixed onto base.
Name Company Catalog Number Comments
Imaging analysis software
Imaris v8.1.2 Bitplane

Riferimenti

  1. Black, J., et al. National Pressure Ulcer Advisory Panel’s updated pressure ulcer staging system. Adv Skin Wound Care. 20, 269-274 (2007).
  2. Kalogeris, T., Baines, C. P., Krenz, M., Korthuis, R. J. Cell biology of ischemia/reperfusion injury. Int Rev Cell Mol Biol. 298, 229-317 (2012).
  3. Huebener, P., et al. The HMGB1/RAGE axis triggers neutrophil-mediated injury amplification following necrosis. J Clin Invest. 125, 539-550 (2015).
  4. Wassermann, E., et al. A chronic pressure ulcer model in the nude mouse. Wound Repair Regen. 17, 480-484 (2009).
  5. Stadler, I., Zhang, R. Y., Oskoui, P., Whittaker, M. S., Lanzafame, R. J. Development of a simple, noninvasive, clinically relevant model of pressure ulcers in the mouse. J Invest Surg. 17, 221-227 (2004).
  6. Tsuji, S., Ichioka, S., Sekiya, N., Nakatsuka, T. Analysis of ischemia-reperfusion injury in a microcirculatory model of pressure ulcers. Wound Repair Regen. 13, 209-215 (2005).
  7. Ng, L. G., et al. Visualizing the neutrophil response to sterile tissue injury in mouse dermis reveals a three-phase cascade of events. J Invest Dermatol. 131, 2058-2068 (2011).
  8. Li, J. L., et al. Intravital multiphoton imaging of immune responses in the mouse ear skin. Nat Protoc. 7, 221-234 (2012).
  9. Tong, P. L., et al. The skin immune atlas: three-dimensional analysis of cutaneous leukocyte subsets by multiphoton microscopy. J Invest Dermatol. 135, 84-93 (2015).
  10. Saito, Y., et al. The loss of MCP-1 attenuates cutaneous ischemia-reperfusion injury in a mouse model of pressure ulcer. J Invest Dermatol. 128, 1838-1851 (2008).
  11. Faust, N., Varas, F., Kelly, L. M., Heck, S., Graf, T. Insertion of enhanced green fluorescent protein into the lysozyme gene creates mice with green fluorescent granulocytes and macrophages. Blood. 96, 719-726 (2000).
  12. Roediger, B., Ng, L. G., Smith, A. L., Fazekasde de St Groth, B., Weninger, W. Visualizing dendritic cell migration within the skin. Histochem Cell Biol. 130, 1131-1146 (2008).
  13. Kikushima, K., Kita, S., Higuchi, H. A non-invasive imaging for the in vivo tracking of high-speed vesicle transport in mouse neutrophils. Sci Rep. 3, 1913 (2013).
  14. Ng, L. G., et al. Migratory dermal dendritic cells act as rapid sensors of protozoan parasites. PLoS Pathog. 4, e1000222 (2008).
  15. Soohoo, A. L., Bowersox, S. L., Puthenveedu, M. A. Visualizing clathrin-mediated endocytosis of G protein-coupled receptors at single-event resolution via TIRF microscopy. J Vis Exp. , e51805 (2014).
  16. Beltman, J. B., Maree, A. F., de Boer, R. J. Analysing immune cell migration. Nat Rev Immunol. 9, 789-798 (2009).
check_url/it/54956?article_type=t

Play Video

Citazione di questo articolo
Goh, C. C., Li, J. L., Becker, D., Weninger, W., Angeli, V., Ng, L. G. Inducing Ischemia-reperfusion Injury in the Mouse Ear Skin for Intravital Multiphoton Imaging of Immune Responses. J. Vis. Exp. (118), e54956, doi:10.3791/54956 (2016).

View Video