Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
DOI:

11:18 min

January 07, 2019

,

Capitoli

  • 00:04Titolo
  • 00:52Preparation of Graphite Oxide
  • 02:11GO-deposited Electrode Preparation
  • 03:07Reduction of GO to Electrochemically Reduced Graphene Oxide
  • 04:29Polyaniline Functionalization of the ERGO Electrode
  • 06:09ERGO-PA Electrode Testing at Different pH (Pre-calibration Before Nafion Coating)
  • 06:46Preparation of the Nafion-coated ERGO-PA Electrode
  • 07:22Preparation of L. lactis Culture Medium
  • 08:23Testing of the ERGO-PA-NA pH Response in an L. lactis Fermentation Experiment
  • 09:08Results: Fabrication of ERGO-PA-NA Electrodes to Detect pH Changes During Microbial Fermentation
  • 10:41Conclusion

Summary

Traduzione automatica

Här rapporterar vi protokollet för tillverkning av en Nafion-belagd, polyaniline-functionalized, elektrokemiskt reducerade grafen oxiden chemiresistive micro pH-sensor. Denna chemiresistor-baserade, solid-state micro pH-sensor kan upptäcka pH-förändringar i realtid under en Lactococcus lactis jäsningsprocessen.