Summary

Realizzazione substrati di coltura complessi utilizzando robotica microcontact stampa (R-μCP) e sequenziale Sostituzione nucleofila

Published: October 31, 2014
doi:

Summary

Cell culture substrates functionalized with microscale patterns of biological ligands have immense utility in the field of tissue engineering. Here, we demonstrate the versatile and automated manufacture of tissue culture substrates with multiple, micropatterned poly(ethylene glycol) brushes presenting orthogonal chemistries that enable spatially precise and site-specific immobilization of biological ligands.

Abstract

In tissue engineering, it is desirable to exhibit spatial control of tissue morphology and cell fate in culture on the micron scale. Culture substrates presenting grafted poly(ethylene glycol) (PEG) brushes can be used to achieve this task by creating microscale, non-fouling and cell adhesion resistant regions as well as regions where cells participate in biospecific interactions with covalently tethered ligands. To engineer complex tissues using such substrates, it will be necessary to sequentially pattern multiple PEG brushes functionalized to confer differential bioactivities and aligned in microscale orientations that mimic in vivo niches. Microcontact printing (μCP) is a versatile technique to pattern such grafted PEG brushes, but manual μCP cannot be performed with microscale precision. Thus, we combined advanced robotics with soft-lithography techniques and emerging surface chemistry reactions to develop a robotic microcontact printing (R-μCP)-assisted method for fabricating culture substrates with complex, microscale, and highly ordered patterns of PEG brushes presenting orthogonal ‘click’ chemistries. Here, we describe in detail the workflow to manufacture such substrates.

Introduction

La capacità delle superfici PEG-innestate per visualizzare leganti biochimici un legame covalente al tempo stesso mantenendo intrinseche proprietà non-fouling li rendono la scelta ideale per gli ambienti di microscala ingegneria personalizzate su substrati di coltura 1,2,3 fare. Le interazioni biospecifici mediate da ligando coniugata spazzole PEG consente l'analisi riduzionistica degli effetti di segnali biochimici si trovano all'interno del complesso in microambienti tessuto vivo su fenotipi di cellule singole. Inoltre, chimiche "click" bio-ortogonale possono essere utilizzati per facilitare l'immobilizzazione direzionale di ligandi in modo che siano presentati in conformazioni native 4-6. Così, microscala patterning spaziale di PEG spazzole è uno strumento versatile per creare design in nicchie in vitro per studiare la segnalazione cellulare indotta da stimoli biochimici immobilizzati 6,7.

Un metodo comune per la generazione di modelli spaziali di cu biochimicaes comporta stampa microcontact (μCP) substrati d'oro rivestite con modelli di PEG alkanethiols coniugati. Poi, i monostrati auto-assemblati micropatterned (SAM) di alkanethiols PEG-ylated limita adsorbimento fisico di molecole biochimiche, ad esempio, le proteine, solo per le regioni non fantasia del substrato 8,9. Tuttavia, i SAM generati da questa tecnica sono sensibili all'ossidazione a lungo termine mezzi di coltura cellulare. Così, μCP'd alkanethiol SAM sono spesso ulteriormente innestate con PEG spazzole polimero con trasferimento atomo-superficie avviato polimerizzazione radicalica (SI-ATRP) per aumentare non sporcare la stabilità della regione 10. In particolare, μCP della iniziatore di polimerizzazione alkanethiol, ω-meraptoundecyl bromoisobutirrato, su superfici d'oro rivestite seguite da SI-ATRP di poli (etilene glicole) metacrilato metil etere (PEGMEMA) monomeri genera superfici con micropatterned a lungo termine, stabile, e non fouling PEG spazzole. Inoltre, questi sono in grado di essere ulteriormente modificato per presentare frazioni chimiche diverse 11.

Approfittando di questa proprietà, Sha et. al. messo a punto un metodo per progettare substrati di coltura con spazzole PEGMEMA più componenti presentano ortogonali chimiche "clic". In questo metodo, si avvalgono di una serie di passaggi μCP / SI-ATRP intervallati da sodio azide sequenziale, etanolammina, e propargylamine sostituzioni nucleofile per creare substrati di coltura che presentano modelli di microscala di più ligandi immobilizzati 6. Mentre la prospettiva di utilizzare tali sostanze chimiche in collegamento con μCP manuale per progettare nuovi substrati di coltura è immenso, è limitata dalla precisione e accuratezza con cui più passaggi μCP possono essere allineate su un unico substrato. Un alto livello di precisione e accuratezza sarebbe necessario per la fabbricazione riproducibile complesso in nicchie vitro utilizzando queste tecniche versatili.

e_content "> Per affrontare questa limitazione, sono stati generati diversi sistemi μCP automatici e semi-automatici. Chakra et. al., messo a punto un sistema di μCP in cui timbri personalizzati sono posti su un sistema ferroviario e messi in contatto conforme con scivoli d'oro rivestite con un attuatore pneumatico controllato da computer. Tuttavia, questo metodo richiede la realizzazione precisa dei disegni provvisorie personalizzati e riporta una precisione di 10 micron con nessuna relazione della precisione ottenuta durante l'esecuzione multipla μCP passaggi 12. Più recentemente, un metodo che utilizza un sistema di accoppiamento cinematico integrato precisione sotto riportato 1 micron utilizzando un singolo modello, ma non erano in grado di allineare con precisione più pattern a causa della mancanza di un controllo preciso delle caratteristiche provvisorie da stampo per stampo 13. Inoltre, entrambi i metodi precedenti richiedono il substrato a rimanere fisso tra passi patterning , con ciò limitando sensibilmente la diversità dei chimici la modifica della superficie che possono essereutilizzata. Qui, descriviamo un sistema R-μCP automatizzato in grado di allineamento accurato e preciso di molteplici passaggi μCP pur consentendo la massima flessibilità nella progettazione e fabbricazione di bollo. Inoltre, i substrati modellati possono essere ripetutamente rimossi dal sistema tra frantumi, permettendo così l'uso di diverse sostanze chimiche modifica substrato, incluse sostituzioni nucleofile sequenziali. Substrati ingegnerizzati l'utilizzo di tali sostanze chimiche sono state utilizzate per colture cellulari in precedenza sia da noi 6,14 e altri 7. Così, abbiamo unito R-μCP e reazioni di sostituzione nucleofila sequenziali per sviluppare un metodo per la produzione scalabile di substrati di coltura con segnali biochimici complessi e micropatterned.

Protocol

1. Generazione elastomerici Francobolli Per generare padroni di silicio del timbro PDMS, di design dispongono di modelli del fotomaschere utilizzando il software computer-aided design. Progettare il primo modello come 20 x 20 serie di corone circolari con 300 micron di diametro interno (ID) e 600 micron OD con 1.200 micron da centro a centro spaziatura. Progettare il secondo pattern come 20 x 20 serie di corone circolari con ID 600 micron e 900 micron OD con 1.200…

Representative Results

L'uso di tecniche di allineamento μCP manuali per ingegnere substrati di coltura con array di spazzole PEG-innestate funzionalizzati con ortogonali "click" chimiche è stata dimostrata in precedenti lavori 6. Tuttavia, questo consente un controllo minimo dell'orientamento del modello e si traduce spesso in sovrapposizione delle aree funzionalizzati. Qui, un nuovo sistema R-μCP viene utilizzato per superare questa limitazione, e la sua capacità di precisione modello una serie di PEG pennel…

Discussion

Substrati ideali per l'ingegneria tissutale sarebbero bioispirati e quindi ricapitolano la distribuzione spaziale dei leganti critici bioattivi presenti all'interno dei tessuti nativi. Avrebbero anche possedere proprietà dinamiche che consentono regolazioni temporali dei leganti e dei modelli spaziali in cui sono presentati per consentire la morfogenesi dei tessuti diretto e spazialmente limitate induzione del destino cellulare. Fabbricazione di tali substrati richiede l'immobilizzazione di molteplici segna…

Disclosures

The authors have nothing to disclose.

Acknowledgements

Funding for this work, GTK, TK, and JDM were provided by the Wisconsin Institute for Discovery and the Wisconsin Alumni Research Foundation.

Materials

Name Company Catalog Number Comments
SCARA  Epson LS3-401ST Higher end models with increased precision are available if desired. 
(TRIDECAFLUORO-1,1,2,2-TETRAHYDROOCTYL)TRICHLOROSILANE Gelest SIT8174.0 CAUTION, Should only be handled in a chemical fume hood. When silanizing wafers no one should enter the hood until all silane has been evaporated.
Sylgard 184 Silicone Elastomer Kit Ellsworth Adhesive Co NC9020938 Thouroughly degass solutions via vacuum exposure before use. Alternative kits such as Kit 182 are acceptable.
24mm X 50 mm #1 Cover Glass Slides Fisher Scientific 48393106 These can be purchased from a number of suppliers with varying dimensions to suit need.
CHA-600 Telemark Electron Beam Evaporator Telemark SEC-600-RAP Requries specialized training.
EPSON LS3 SCARA EPSON LS3-401ST
ω-mertcaptoundecyl bromoisobutyrate Prochimia FT 015-m11-0.2 Store at -20°C. Other ATRP initiators may be used as this R-μCP platform is applicable to all micropatterning modalities. 
Schlenk Tube Flask 50 mL Synthware 60003-078 Requires rubber stoppers with diaphram.
Poly(ethylene glycol) methyl ether methacrylate Sigma Aldrich 447943 Shipped containing MEHQ and BHT free readical inhibitors.
Methanol (Certified ACS) Fisher Scientific A412-4 CAUTION, only handle in chemical fume hood.
Copper(II) Bromide Sigma Aldrich 437867 CAUTION, limit exposure with surgical mask.
2',2-Bipyridine Sigma Aldrich D216305 CAUTION, limit exposure with surgical mask.
Sodium L-Ascorbate Sigma Aldrich A4034
20mL Borosilicate Glass Scintillation Vials Fisher Scientific 03-340-4E
Sodium Azide Sigma Aldrich S2002 CAUTION, limit exposure with surgical mask.
N,N-dimethyformamide Sigma Aldrich 227056 CAUTION, only handle in chemical fume hood.
Ethanolamine Sigma Aldrich 398136 CAUTION, only handle in chemical fume hood.
Triethylamine Sigma Aldrich T0886 CAUTION, only handle in chemical fume hood.
Dimethylsulfoxide Sigma Aldrich 276855 CAUTION, only handle in chemical fume hood.
Propargylamine Sigma Aldrich P50900 CAUTION, only handle in chemical fume hood.
200 Proof Ethanol University of Wisconsin Material Distribution Services 2292 CAUTION, only handle in chemical fume hood.
Azide-PEG3-Biotin ClickChemistryTools AZ104-100 Solubilized in DMF
Copper(II) Sulfate Sigma Aldrich C1297 CAUTION, limit exposure with surgical mask.
Tris[(1-benzyl-1H-1,2,3-triazol-4-yl)methyl]amine (TBTA) Sigma Aldrich 678937
L-Ascorbic Acid Sigma Aldrich A7506
Phosphate Buffer Saline Invitrogen 14190144
Donkey Serum Sigma Aldrich D9663 Donkey serum contaminated items are considered bio-hazardous material and should be disposed of accordingly. Various other compounds (e.g. BSA) are available and serve this purpose.
12-Well Polystyrene Plate Thermo Scientifit – NUNC 07-200-81 Plates can be purchased form a number of suppliers with varying dimensions.
DBCO-PEG4-Biotin Clickchemistytools A105P4-10 Solubilized in DMF
Streptavidin, Alexa Fluor 488 Conjugate Life Technologies S-11223 Solubilized in PBS
Streptavidin, Alexa Fluor 546 conjugate Life Technologies S-11225 Solubilized in PBS
Nikon A1-R Confocal Microscope Nikon Nikon Eclipse Ti, A1R An epifluorescent microscope is sufficient to image functionalized micropatterned substrates.

References

  1. Senaratne, W., Andruzzi, L., Ober, C. K. Self-Assembled Monolayers and Polymer Brushes in Biotechnology: Current Applications and Future Perspectives. Biomacromolecules. 6 (5), 2427-2448 (2005).
  2. Hucknall, A., Kim, D. -. H., Rangarajan, S., Hill, R. T., Reichert, W. M., Chilkoti, A. Simple Fabrication of Antibody Microarrays on Nonfouling Polymer Brushes with Femtomolar Sensitivity for Protein Analytes in Serum and Blood. Advanced Materials. 21 (19), 1968-1971 (2009).
  3. Hucknall, A., Rangarajan, S., Chilkoti, A. In Pursuit of Zero: Polymer Brushes that Resist the Adsorption of Proteins. Advanced Materials. 21 (23), 2441-2446 (2009).
  4. Rozkiewicz, D. I., Jańczewski, D., Verboom, W., Ravoo, B. J., Reinhoudt, D. N. Click” Chemistry by Microcontact Printing. Angewandte Chemie International Edition. 45 (32), 5292-5296 (2006).
  5. Jewett, J. C., Bertozzi, C. R. Cu-free click cycloaddition reactions in chemical biology. Chemical Society Reviews. 39 (4), 1272-1279 (2010).
  6. Sha, J., Lippmann, E. S., McNulty, J., Ma, Y., Ashton, R. S. Sequential Nucleophilic Substitutions Permit Orthogonal Click Functionalization of Multicomponent PEG Brushes. Biomacromolecules. 14 (9), 3294-3303 (2013).
  7. Tugulu, S., Silacci, P., Stergiopulos, N., Klok, H. -. A. RGD—Functionalized polymer brushes as substrates for the integrin specific adhesion of human umbilical vein endothelial cells. Biomaterials. 28 (16), 2536-2546 (2007).
  8. Ashton, R. S., et al. High-Throughput Screening of Gene Function in Stem Cells Using Clonal Microarrays. Stem Cells. 25 (11), 2928-2935 (2007).
  9. Koepsel, J. T., Murphy, W. L. Patterned Self-Assembled Monolayers: Efficient, Chemically Defined Tools for Cell Biology. ChemBioChem. 13 (12), 1717-1724 (2012).
  10. Mrksich, M., Dike, L. E., Tien, J., Ingber, D. E., Whitesides, G. M. Using microcontact printing to pattern the attachment of mammalian cells to self-assembled monolayers of alkanethiolates on transparent films of gold and silver. Experimental cell research. 235 (2), 305-313 (1997).
  11. Ma, H., Hyun, J., Stiller, P., Chilkoti, A. Non-Fouling” Oligo(ethylene glycol)- Functionalized Polymer Brushes Synthesized by Surface-Initiated Atom Transfer Radical Polymerization. Advanced Materials. 16 (4), 338-341 (2004).
  12. Bou Chakra, E., Hannes, B., Dilosquer, G., Mansfield, D. C., Cabrera, M. A new instrument for automated microcontact printing with stamp load adjustment. Review of Scientific Instruments. 79 (6), (2008).
  13. Trinkle, C. A., Lee, L. P. High-precision microcontact printing of interchangeable stamps using an integrated kinematic coupling. Lab on a Chip. 11 (3), 455 (2011).
  14. McNulty, J., et al. High-precision robotic microcontact printing (R-μCP) utilizing a vision guided selectively compliant articulated robotic arm. Lab on a Chip. , (2014).
  15. Qin, D., Xia, Y., Whitesides, G. M. Soft lithography for micro- and nanoscalepatterning. Nature Protocols. 5 (3), 491-502 (2010).
  16. Nam, Y., Chang, J. C., Wheeler, B. C., Brewer, G. J. Gold-Coated Microelectrode Array With Thiol Linked Self-Assembled Monolayers for Engineering Neuronal Cultures. IEEE Transactions on Biomedical Engineering. 51 (1), 158-165 (2004).
  17. Ma, H., Wells, M., Beebe, T. P., Chilkoti, A. Surface-Initiated Atom Transfer Radical Polymerization of Oligo(ethylene glycol) Methyl Methacrylate from a Mixed Self-Assembled Monolayer on Gold. Advanced Functional Materials. 16 (5), 640-648 (2006).
  18. Scadden, D. T. The stem-cell niche as an entity of action. Nature. 441 (7097), (2006).
  19. Codelli, J. A., Baskin, J. M., Agard, N. J., Bertozzi, C. R. Second-Generation Difluorinated Cyclooctynes for Copper-Free Click Chemistry. Journal of the American Chemical Society. 130 (34), 11486-11493 (2008).
  20. Debets, M. F., van Berkel, S. S., Schoffelen, S., Rutjes, F. P. J. T., van Hest, J. C. M., van Delft, F. L. Aza-dibenzocyclooctynes for fast and efficient enzyme PEGylation via copper-free (3+2) cycloaddition. Chemical Communications. 46 (1), 97 (2010).
  21. DeForest, C. A., Polizzotti, B. D., Anseth, K. S. Sequential click reactions for synthesizing and patterning three-dimensional cell microenvironments. Nature Materials. 8 (8), 659-664 (2009).
  22. Roth, E. A., Xu, T., Das, M., Gregory, C., Hickman, J. J., Boland, T. Inkjet printing for high-throughput cell patterning. Biomaterials. 25 (17), 3707-3715 (2004).
  23. Xu, T., Zhao, W., Zhu, J. M., Albanna, M. Z., Yoo, J. J., Atala, A. Biomaterials. Biomaterials. 34 (1), 130-139 (2013).
  24. Brouzes, E., et al. Droplet microfluidic technology for single-cell high-throughput screening. Proceedings of the National Academy of Sciences. 106 (34), 14195-14200 (2009).
  25. Meitl, M. A., et al. Transfer printing by kinetic control of adhesion to an elastomeric stamp. Nature Materials. 5 (1), 33-38 (2005).

Play Video

Cite This Article
Knight, G. T., Klann, T., McNulty, J. D., Ashton, R. S. Fabricating Complex Culture Substrates Using Robotic Microcontact Printing (R-µCP) and Sequential Nucleophilic Substitution. J. Vis. Exp. (92), e52186, doi:10.3791/52186 (2014).

View Video