Summary

La evaluación de resultado primaria en un modelo porcino de infarto agudo de miocardio

Published: October 14, 2016
doi:

Summary

la evaluación del resultado fiable y precisa es la clave para la traducción de las terapias preclínicos en el tratamiento clínico. El presente documento describe la forma de evaluar tres parámetros de resultado primaria clínicamente relevantes de la función cardiaca y daños en un modelo porcino de infarto de miocardio agudo.

Abstract

Mortality after acute myocardial infarction remains substantial and is associated with significant morbidity, like heart failure. Novel therapeutics are therefore required to confine cardiac damage, promote survival and reduce the disease burden of heart failure. Large animal experiments are an essential part in the translational process from experimental to clinical therapies. To optimize clinical translation, robust and representative outcome measures are mandatory. The present manuscript aims to address this need by describing the assessment of three clinically relevant outcome modalities in a pig acute myocardial infarction (AMI) model: infarct size in relation to area at risk (IS/AAR) staining, 3-dimensional transesophageal echocardiography (TEE) and admittance-based pressure-volume (PV) loops. Infarct size is the main determinant driving the transition from AMI to heart failure and can be quantified by IS/AAR staining. Echocardiography is a reliable and robust tool in the assessment of global and regional cardiac function in clinical cardiology. Here, a method for three-dimensional transesophageal echocardiography (3D-TEE) in pigs is provided. Extensive insight into cardiac performance can be obtained by admittance-based pressure-volume (PV) loops, including intrinsic parameters of myocardial function that are pre- and afterload independent. Combined with a clinically feasible experimental study protocol, these outcome measures provide researchers with essential information to determine whether novel therapeutic strategies could yield promising targets for future testing in clinical studies.

Introduction

La insuficiencia cardíaca con fracción de eyección reducida (ICFER) representa aproximadamente el 50% de todos los casos de insuficiencia cardiaca, que afecta a un estimado de 1 – 2% de las personas en el mundo occidental 1. Su causa más frecuente es el infarto agudo de miocardio (IAM). Como la mortalidad aguda del IAM ha disminuido considerablemente debido a una mayor conciencia y mejores opciones de tratamiento, el énfasis se ha desplazado hacia sus secuelas crónicas; el ser más prominente ICFER 2,3. Junto con el aumento de los costos del cuidado de la salud 4, la creciente epidemia de insuficiencia cardíaca hace hincapié en la necesidad de nuevos diagnósticos y terapias, que puede ser estudiado en un modelo porcino altamente traslación del remodelado adverso tras el IAM como se describió previamente 5.

Ambos, determinantes (por ejemplo, el tamaño del infarto) y funcionales evaluaciones (por ejemplo, ecocardiografía) de remodelado adverso a menudo se utilizan para las pruebas de eficacia de nuevas terapias, lo que indica la necesidad de relmétodos iable y relativamente barato. El objetivo del presente trabajo es abordar esta necesidad mediante la introducción de importantes y fiables medidas de resultado de los ensayos de eficacia en un modelo porcino de infarto agudo de miocardio. Estos incluyen el tamaño del infarto (IS) en relación con el área en riesgo (AAR), la ecocardiografía transesofágica 3D (3D-ETE) y la adquisición de bucle detallada basada en la admisión de presión-volumen (PV).

El tamaño del infarto es el principal determinante del remodelado adverso y la supervivencia después de un IAM 6. A pesar de la reperfusión de miocardio isquémico oportuna puede salvar cardiomiocitos de forma reversible heridos y limitar el tamaño del infarto, la reperfusión en sí causa un daño adicional a través de la generación de estrés oxidativo y una respuesta inflamatoria desproporcionada (lesión por isquemia-reperfusión (IRI)) 7. Por lo tanto, IRI ha sido identificado como un objetivo terapéutico prometedor. La capacidad de nuevas terapias para disminuir el tamaño del infarto se cuantifica mediante la evaluación del tamaño del infarto en relacióna la zona de riesgo (AAR). AAR cuantificación es obligatoria para corregir la variabilidad entre individuos en la anatomía coronaria de modelos animales, como AAR más grande conduce a un tamaño del infarto absoluta más grande. Desde el tamaño del infarto está directamente relacionada con el rendimiento cardíaco y la contractilidad del miocardio, las variaciones en AAR pueden influir estudiar medidas de resultado independientemente de las modalidades de tratamiento 8.

Tridimensional ecocardiografía transesofágica (ETE-3D) es un método barato seguro, fiable y, lo más importante, aplicable clínicamente para medir la función cardiaca no invasiva. Mientras que la ecocardiografía transtorácica (ETT), las imágenes se limitan a las vistas 2D largo paraesternal y de eje corto en cerdos 9, 3D-ETE puede ser utilizado para obtener imágenes en 3 dimensiones completas del ventrículo izquierdo. Por lo tanto, no requiere de aproximaciones matemáticas del ventrículo izquierdo (VI) volúmenes, tales como la regla 10 de Simpson modificado. Este último está a la altura de la corrrectamente la estimación de los volúmenes del VI después de remodelado del VI debido a la falta de geometría cilíndrica 11. Por otra parte, 3D-TEE es preferible sobre la ecocardiografía epicárdica, ya que no requiere intervenciones quirúrgicas, que se han observado para ejercer efectos cardioprotectores en el presente modelo 12. Aunque el uso de 2D-TEE para la evaluación de la función miocárdica se ha descrito antes 13,14, limitaciones en cuanto a la geometría ventricular son similares a los observados en 2D-TTE y dependen de la extensión de LV remodelación. Por lo tanto, cuanto mayor sea el infarto (y por lo tanto mayor es la probabilidad de la insuficiencia cardíaca), las mediciones 2D más probablemente se convierta en defectuoso por suposiciones incorrectas geométricas y mayor la necesidad de técnicas de 3D.

No obstante, la mayoría de modalidades de imágenes están limitados en su capacidad para evaluar las propiedades funcionales intrínsecas del miocardio. PV bucles de proporcionar dicha información adicional pertinente y, por tanto, su adquisición esse describe en detalle a continuación.

Protocol

Todos los experimentos con animales fueron aprobados por el Comité Ético de Experimentación Animal de la Universidad del Centro Médico de Utrecht (Utrecht, Holanda) y se ajustan a la "Guía para el cuidado y uso de animales de laboratorio". NOTA: El protocolo para realizar una oclusión con balón a tórax cerrado no es parte del manuscrito actual y se describe en detalle en otra parte 5. En resumen, los cerdos (60 – 70 kg) se sometieron a 75 min de oclusión con bal…

Representative Results

3D ecocardiografía transesofágica 3D ecocardiografía transesofágica (ETE-3D) se puede utilizar para la evaluación de la función cardíaca global. Después de un IAM, la función cardíaca global difiere de los valores basales sanos. En particular, la fracción de eyección ventricular izquierda (FEVI) disminuye de 59 ± 4% a 37 ± 6% después de una semana de reperfusión (n = 10) (GPJ van Hout, 20…

Discussion

La remodelación cardiaca depende en gran medida de tamaño del infarto de miocardio y la calidad de infarto de miocardio reparar 6,26. Para evaluar la ex de una manera estandarizada, el presente manuscrito proporciona un método elegante de la infusión in vivo de azul de Evans en combinación con tinción TTC ex vivo, que ha sido validado y ampliamente utilizado 8,16,27,28. Este método permite la cuantificación de la zona de riesgo (AAR) y el tamaño del infarto en relación c…

Disclosures

The authors have nothing to disclose.

Acknowledgements

The authors gratefully acknowledge Marlijn Jansen, Joyce Visser, Grace Croft, Martijn van Nieuwburg, Danny Elbersen and Evelyn Velema for their excellent technical support during the animal experiments.

Materials

3-dimensional transesophageal echocardiography
iE33 ultrasound device Philips
X7-2t transducer Philips
Aquasonic® 100 ultrasound transmission gel Parker Laboratories Inc. 01-34 Alternative product can be used
Battery handle type C (laryngoscope handle) Riester 12303
Ri-Standard Miller blade MIL 4 (laryngoscope blade) Riester 12225
Qlab 10.0 (3DQ Advanced) analysis software Philips
Name Company Catalog Number Comments
Pressure-volume loop acquisition
Cardiac defibrillator Philips
0.9% saline Braun
8F Percutaneous Sheath Introducer Set Arrow CP-08803 Alternative product can be used
9F Radifocus® Introducer II Standard Kit  Terumo RS*A90K10SQ Alternative product can be used
8F Fogarty catheter Edward Life Sciences 62080814F Alternative product can be used
7F Criticath™ SP5107H TD catheter (Swan-Ganz) Becton Dickinson (BD) 680078 Alternative product can be used
Ultraview SL Patient Monitor and Invasive Command Module (external cardiac output device) Spacelabs Healthcare 91387 Alternative product can be used
ADVantage system™ Transonic SciSense
7F tetra-polar admittance catheter (7.0 VSL Pigtail / no lumen) Transonic SciSense
Multi-channel acquisition system (Iworx 404) Iworx
Labscribe V2.0 analysis software Iworx Alternative product can be used
Name Company Catalog Number Comments
Infarct size / area-at-risk quantification
Diathermy Alternative product can be used
Lebsch knife Alternative product can be used
Hammer Alternative product can be used
Bone marrow wax Syneture Alternative product can be used
Klinkenberg scissors Alternative product can be used
Retractor Alternative product can be used
Surgical scissors
7F Percutaneous Sheath Introducer Set  Arrow CP-08703 Alternative product can be used
8F Percutaneous Sheath Introducer Set  Arrow CP-08803 Alternative product can be used
7F JL4 guiding catheter  Boston Scientific H749 34357-662 Alternative product can be used
8F JL4 guiding catheter  Boston Scientific H749 34358-662  Alternative product can be used
COPILOT Bleedback Control Valves  Abbott Vascular 1003331 Alternative product can be used
BD Connecta™  Franklin Lakes 394995 Alternative product can be used
Contrast agent Telebrix
Persuader 9 Steerable Guidewire 9 (0.014", 180 cm, straight tip), hydrophilic coating Medtronic Inc. 9PSDR180HS Alternative product can be used
SAPPHIRE™ Coronary Dilatation Catheter (PTCA balloon suitable for the size of the particular coronary artery (2.75 – 3.25 mm)) OrbusNeich 103-3015 Alternative product can be used
Evans Blue  Sigma-Aldrich E2129-100G Toxic. Alternative product can be used
2,3,5-triphenyl-tetrazolium chloride (TTC) Sigma-Aldrich T8877-100G Irritant. Alternative product can be used
9V battery
Ruler
Photocamera Sony
ImageJ National Institutes of Health Alternative product can be used

References

  1. Mosterd, A., Hoes, A. W. Clinical epidemiology of heart failure. Heart. 93 (9), 1137-1146 (2007).
  2. Nichols, M., et al. . European Cardiovascular Disease Statistics. , (2012).
  3. Krumholz, H. M., et al. Reduction in Acute Myocardial Infarction Mortality in the United States. JAMA. 302 (7), 767-773 (2010).
  4. Go, A. S., et al. Heart disease and stroke statistics – 2013 update: A Report from the American Heart Association. Circulation. 127 (1), (2013).
  5. Koudstaal, S., et al. Myocardial infarction and functional outcome assessment in pigs. J. Vis. Exp. (86), e51269 (2014).
  6. Chareonthaitawee, P., Christian, T. F., Hirose, K., Gibbons, R. J., Rumberger, J. A. Relation of initial infarct size to extent of left ventricular remodeling in the year after acute myocardial infarction. J. Am. Coll. Cardiol. 25 (3), 567-573 (1995).
  7. Yellon, D. M., Hausenloy, D. J. Myocardial reperfusion injury. N. Engl. J. Med. 357 (11), 1221-1235 (2007).
  8. Suzuki, Y., Lyons, J. K., Yeung, A. C., Ikeno, F. In vivo porcine model of reperfused myocardial infarction: In situ double staining to measure precise infarct area/area at risk. Catheter Cardiovasc. Interv. 71 (1), 100-107 (2008).
  9. Weidemann, F., et al. Myocardial function defined by strain rate and strain during alterations in inotropic states and heart rate. Am. J. Physiol. Heart Circ. Physiol. 283 (2), H792-H799 (2002).
  10. Mercier, J. C., et al. Two-dimensional echocardiographic assessment of left ventricular volumes and ejection fraction in children. Circulation. 65 (5), 962-969 (1982).
  11. De Jong, R., et al. Cardiac Function in a Long-Term Follow-Up Study of Moderate and Severe Porcine Model of Chronic Myocardial Infarction. Biomed. Res. Int. 2015, 1-11 (2015).
  12. Van Hout, G. P. J., et al. Invasive surgery reduces infarct size and preserves cardiac function in a porcine model of myocardial infarction. J. Cell. Mol. Med. , 2655-2663 (2015).
  13. Meybohm, P., et al. Assessment of left ventricular systolic function during acute myocardial ischemia: A comparison of transpulmonary thermodilution and transesophageal echocardiography. Minerva Anestesiol. 77 (2), 132-141 (2011).
  14. Gruenewald, M., et al. Visual evaluation of left ventricular performance predicts volume responsiveness early after resuscitation from cardiac arrest. Resuscitation. 82 (12), 1553-1557 (2011).
  15. Bolli, R., Becker, L., Gross, G., Mentzer, R., Balshaw, D., Lathrop, D. A. Myocardial protection at a crossroads: The need for translation into clinical therapy. Circ. Res. 95 (2), 125-134 (2004).
  16. Timmers, L., et al. Exenatide reduces infarct size and improves cardiac function in a porcine model of ischemia and reperfusion injury. J. Am. Coll. Cardiol. 53 (6), 501-510 (2009).
  17. Csonka, C., et al. Measurement of myocardial infarct size in preclinical studies. J. Pharmacol. Toxicol. Methods. 61 (2), 163-170 (2010).
  18. Law, R., Katzka, D. A., Baron, T. H. Zenker’s Diverticulum. Clin. Gastroenterol. Hepatol. 12 (11), 1773-1782 (2014).
  19. Philips Healthcare. . QLAB 10.0 Quick Card: 3DQ and 3DQ Adv measurements guide. , (2013).
  20. Transonic. . ADV500 Pressure-Volume Measurement System Use and Care Manual, version 5. , (2006).
  21. Schramm, W. Is the cardiac output obtained from a Swan-Ganz catheter always zero?. J. Clin. Monit. Comput. 22 (6), 431-433 (2008).
  22. iWorx. . LabScribe 3: Software Manual for Pressure-Volume Analyses. , (2014).
  23. Hueper, W. C., Ichniowski, C. T. Toxicopathologic studies on the dye T-1824. Arch. Surg. 48 (1), 17-26 (1944).
  24. Van Hout, G. P. J., et al. Admittance-based pressure-volume loops versus gold standard cardiac magnetic resonance imaging in a porcine model of myocardial infarction. Physiol. Rep. 2 (4), 1-9 (2014).
  25. Burkhoff, D., Mirsky, I., Suga, H. Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guide for clinical, translational, and basic researchers. Am. J. Physiol. Heart Circ. Physiol. Heart Circ. Physiol. 289 (2), H501-H512 (2005).
  26. Frangogiannis, N. G. The inflammatory response in myocardial injury, repair, and remodelling. Nat. Rev. Cardiol. 11 (5), 255-265 (2014).
  27. Fishbein, M., et al. Early phase acute myocardial infarct size quantification: validation of the triphenyl tetrazolium chloride tissue enzyme staining technique. Am. Heart. J. 101 (5), 593-600 (1981).
  28. Arslan, F., et al. Treatment with OPN-305, a humanized anti-toll-like receptor-2 antibody, reduces myocardial ischemia/reperfusion injury in pigs. Circ. Cardiovasc. Interv. 5 (2), 279-287 (2012).
  29. Meyns, B., Stolinski, J., Leunens, V., Verbeken, E., Flameng, W. Left ventricular support by Catheter-Mountedaxial flow pump reduces infarct size. J. Am. Coll. Cardiol. 41 (7), 1087-1095 (2003).
  30. Khalil, P. N., et al. Histochemical assessment of early myocardial infarction using 2,3,5-triphenyltetrazolium chloride in blood-perfused porcine hearts. J. Pharmacol. Toxicol. Methods. 54 (3), 307-312 (2006).
  31. Gardner, B. I., Bingham, S. E., Allen, M. R., Blatter, D. D., Anderson, J. L. Cardiac magnetic resonance versus transthoracic echocardiography for the assessment of cardiac volumes and regional function after myocardial infarction: an intrasubject comparison using simultaneous intrasubject recordings. Cardiovasc. Ultrasound. 7, 38 (2009).
  32. Santos-Gallego, C., et al. 3D-Echocardiography Demonstrates Excellent Correlation With Cardiac Magnetic Resonance for Assessment of Left Ventricular Function and Volumes in a Model of Myocardial Infarction. J. Am. Coll. Cardiol. 59 (13), E1564 (2012).
  33. Keith Jones, ., W, , et al. Peripheral nociception associated with surgical incision elicits remote nonischemic cardioprotection via neurogenic activation of protein kinase C signaling. Circulation. 120, S1-S9 (2009).
  34. Gross, G. J., Baker, J. E., Moore, J., Falck, J. R., Nithipatikom, K. Abdominal Surgical Incision Induces Remote Preconditioning of Trauma (RPCT) via Activation of Bradykinin Receptors (BK2R) and the Cytochrome P450 Epoxygenase Pathway in Canine Hearts. Cardiovasc. Drugs Ther. 25 (6), 517-522 (2011).
  35. Van Hout, G. P. J., de Jong, R., Vrijenhoek, J. E. P., Timmers, L., Duckers, H. J., Hoefer, I. E. Admittance-based pressure-volume loop measurements in a porcine model of chronic myocardial infarction. Exp. Physiol. 98 (11), 1565-1575 (2013).
  36. Sunagawa, K., Maughan, W. L., Burkhoff, D., Sagawa, K. Left ventricular interaction with arterial load studied in isolated canine ventricle. Am. J. Physiol. 245 (5 Pt 1), H773-H780 (1983).
  37. Steendijk, P., Baan, J., Der Velde, E. T. V. a. n., Baan, J. Effects of critical coronary stenosis on global systolic left ventricular function quantified by pressure-volume relations during dobutamine stress in the canine heart. J. Am. Coll. Cardiol. 32 (3), 816-826 (1998).
check_url/kr/54021?article_type=t

Play Video

Cite This Article
Ellenbroek, G. H., van Hout, G. P., Timmers, L., Doevendans, P. A., Pasterkamp, G., Hoefer, I. E. Primary Outcome Assessment in a Pig Model of Acute Myocardial Infarction. J. Vis. Exp. (116), e54021, doi:10.3791/54021 (2016).

View Video