Summary

Un modèle pour Simuler Hypoxie cliniquement importants chez les humains

Published: December 22, 2016
doi:

Summary

simulation de l'hypoxie chez l'homme a généralement été réalisée par l'inhalation de mélanges gazeux hypoxiques. Pour cette étude, les plongeurs apnéiques ont été utilisés pour simuler l'hypoxie dynamique chez l'homme. En outre, des changements physiologiques dans désaturation et re-saturation cinétiques ont été évaluées avec des outils non invasifs tels que Near-Infrared-Spectroscopy (NIRS) et périphérique saturation d'oxygénation (SpO 2).

Abstract

In case of apnea, arterial partial pressure of oxygen (pO2) decreases, while partial pressure of carbon dioxide (pCO2) increases. To avoid damage to hypoxia sensitive organs such as the brain, compensatory circulatory mechanisms help to maintain an adequate oxygen supply. This is mainly achieved by increased cerebral blood flow. Intermittent hypoxia is a commonly seen phenomenon in patients with obstructive sleep apnea. Acute airway obstruction can also result in hypoxia and hypercapnia. Until now, no adequate model has been established to simulate these dynamics in humans. Previous investigations focusing on human hypoxia used inhaled hypoxic gas mixtures. However, the resulting hypoxia was combined with hyperventilation and is therefore more representative of high altitude environments than of apnea. Furthermore, the transferability of previously performed animal experiments to humans is limited and the pathophysiological background of apnea induced physiological changes is poorly understood. In this study, healthy human apneic divers were utilized to mimic clinically relevant hypoxia and hypercapnia during apnea. Additionally, pulse-oximetry and Near Infrared Spectroscopy (NIRS) were used to evaluate changes in cerebral and peripheral oxygen saturation before, during, and after apnea.

Introduction

hypoxie aiguë cliniquement pertinente et hypercapnie concomitante est surtout observée chez les patients avec syndrome d'apnée obstructive du sommeil (SAOS), obstruction des voies respiratoires aiguë ou pendant la réanimation cardio-pulmonaire. Les principales limitations dans le domaine du SAOS et d' autres conditions hypoxiques comprennent les connaissances transférables limitées sur la physiopathologie provenant d'études animales et que les modèles humains sont inexistants 1. Pour imiter l' hypoxie chez les humains, les mélanges de gaz hypoxiques ont jusqu'à présent été utilisés 2-7. Cependant, ces conditions sont plus représentatifs d'un environnement de haute altitude que des situations cliniques où l'hypoxie, en général, est accompagnée d'hypercapnie. Pour surveiller l' oxygénation des tissus lors de l' arrestation et de la réanimation cardiaque, des études animales ont été effectuées 8 pour étudier les mécanismes compensatoires physiologiques.

les plongeurs en apnée sont des athlètes en bonne santé capables de peser sur l'impulsion de la respirationqui est évoqué par une faible saturation artérielle en oxygène 9 et une augmentation de la pCO 2 10,11. Nous avons étudié les plongeurs apnéiques afin d'imiter des situations cliniques d'hypoxie aiguë et hypercapnie concomitante 12. Ce modèle peut être utilisé pour évaluer les configurations cliniques, améliorer la compréhension physiopathologique des patients atteints de SAOS ou de troubles respiratoires pathologiques, et de révéler de nouvelles possibilités pour étudier un mécanisme potentiel compteur d'équilibrage dans les cas d'apnée. En outre, différentes techniques pour détecter l' hypoxie chez l' homme peut être testé pour la faisabilité et la précision dans le cas d'hypoxie dynamique qui est présent dans les situations d'urgence ( par exemple, les obstructions des voies respiratoires, laryngospasme ou ne peut pas intuber, ne peut pas ventiler les situations) ou pour simuler l' hypoxie intermittente chez les patients avec SAOS.

techniques non invasives pour détecter l'hypoxie chez l'homme sont limitées. Peripheral oxymétrie de pouls (SpO 2) est un outil approuvé en pré-hospital et les milieux hospitaliers pour détecter l' hypoxie 13. La méthode est basée sur l'absorption de la lumière de l'hémoglobine. Cependant, SpO 2 mesure est limitée à l' oxygénation artérielle périphérique et ne peut pas être utilisé dans les cas d'activité pulseless électrique (PEA) ou la circulation minimale centralisée 14. En revanche, spectroscopie proche infrarouge peut être utilisé pour évaluer cérébrale saturation en oxygène tissulaire (RSO 2) en temps réel lors de PEA, lors d'un choc hémorragique ou après une hémorragie méningée 15-19. Son utilisation est en constante augmentation 20 et des études méthodologiques ont révélé une corrélation positive entre la SpO 2 et RSO 2 3,4.

Dans cette étude, nous proposons un modèle pour simuler l'hypoxie cliniquement pertinente chez l'homme et de présenter une méthodologie étape par étape pour comparer l'oxymétrie de pouls périphérique et SPIR en cas de dé- et re-saturation. En analysant les données physiologiques en cas dePNEA, notre compréhension des mécanismes d'équilibrage de compteur peut être améliorée.

Protocol

déclaration éthique Toutes les procédures effectuées dans des études impliquant des participants humains étaient en conformité avec les normes éthiques de la déclaration d'Helsinki de 1964 et ses amendements ultérieurs. La conception de cette étude a été approuvée par le comité d'éthique local de l'hôpital universitaire de Bonn, en Allemagne. NOTE: Veiller à ce que les sujets sont en bonne santé et condition, libre de tout médicament anti-hypertenseur et au moins 24 heures sans…

Representative Results

Figure 1 affiche des enregistrements simultanés de SpO 2 et les valeurs NIRS (NIRS de tissu cérébral et NIRS) lors de l' apnée chez un patient. le temps d'apnée totale était de 363 sec. Après l' apnée NIRS et SpO 2 valeurs sont restées stables pendant environ 140 secondes. Une diminution de la SpO 2 a été détectée après 204 secondes par SpO périphérique 2 alors qu'une diminu…

Discussion

Le temps d'apnée totale est causée principalement par la taille du poumon et de la consommation d'oxygène par minute et influencée par la capacité d'un individu à supporter le réflexe respiratoire causée par l' augmentation ou la diminution de la pCO 2 pO 2. plongeurs d'apnée sont formés pour maximiser leur durée d'apnée et sont utilisés pour faire en inspiration maximale. Par conséquent, le temps jusqu'à ce que l'hypoxie est diffère décelables entre…

Disclosures

The authors have nothing to disclose.

Acknowledgements

Special thanks to all volunteers who participated in the original study. The work of L. Eichhorn was supported through a scholarship of the Else-Kröner-Fresenius Foundation. The authors would like to thank Springer, Part of Springer Science+Business Media, for copyright clearance (License Number 3894660871180) and the kind permission of reusing previously published data.

Materials

SpO2 Dräger Medical AG&CO.KG SHP ACC MCABLE-Masimo Set peripheral SpO2-Monitoring
Non Invasive Blood Pressure (NIBP) Dräger Medical AG&CO.KG NIBP cuff M+,  MP00916 
Electrocardiographic (ECG)   Dräger Medical AG&CO.KG Infinity M540 Monitor ECG monitoring
Docking station Dräger Medical AG&CO.KG M500 Docking Station connection of M540 to laptop
NIRS NONIN Medical’s EQUANOX Model 7600 Regional Oximeter System measuring of cerebral and  tissue oxygenation
NIRS diodes EQUANOX Advance Sensor Model 8004CA suited for measuring cerebral and somatic oxygen-saturation
Laptop 
DataGrabber Dräger Medical AG&CO.KG DataGrabber v2005.10.16 software to synchronize M540 with laptop
eVision Nonin Medical. Inc. Version 1.3.0.0 software to synchronize NONIN with laptop

References

  1. Drager, L. F., Polotsky, V. Y., O’Donnell, C. P., Cravo, S. L., Lorenzi-Filho, G., Machado, B. H. Translational approaches to understanding metabolic dysfunction and cardiovascular consequences of obstructive sleep apnea. Am J Physiol Heart Circ Physiol. 309 (7), 1101-1111 (2015).
  2. Shah, N., Trivedi, N. K., Clack, S. L., Shah, M., Shah, P. P., Barker, S. Impact of hypoxemia on the performance of cerebral oximeter in volunteer subjects. J Neurosurg Anesthesiol. 12 (3), 201-209 (2000).
  3. Ricci, M., Lombardi, P., et al. Near-infrared spectroscopy to monitor cerebral oxygen saturation in single-ventricle physiology. J Thorac Cardiovasc Surg. 131 (2), 395-402 (2006).
  4. Kusaka, T., Isobe, K., et al. Quantification of cerebral oxygenation by full-spectrum near-infrared spectroscopy using a two-point method. Comp Biochem Physiol A Mol Integr Physiol. 132 (1), 121-132 (2002).
  5. Nishimura, N., Iwasaki, K., Ogawa, Y., Shibata, S. Oxygen administration, cerebral blood flow velocity, and dynamic cerebral autoregulation. Aviat Space Environ Med. 78 (12), 1121-1127 (2007).
  6. Wilson, M. H., Newman, S., Imray, C. H. The cerebral effects of ascent to high altitudes. Lancet Neurol. 8 (2), 175-191 (2009).
  7. Sanborn, M. R., Edsell, M. E., et al. Cerebral hemodynamics at altitude: effects of hyperventilation and acclimatization on cerebral blood flow and oxygenation. Wilderness Environ Med. 26 (2), 133-141 (2015).
  8. Reynolds, J. C., Salcido, D., et al. Tissue oximetry by near-infrared spectroscopy in a porcine model of out-of-hospital cardiac arrest and resuscitation. Resuscitation. 84 (6), 843-847 (2013).
  9. Andersson, J. P. A., Evaggelidis, L. Arterial oxygen saturation and diving response during dynamic apneas in breath-hold divers. Scand J Med Sci Sports. 19 (1), 87-91 (2009).
  10. Overgaard, K., Friis, S., Pedersen, R. B., Lykkeboe, G. Influence of lung volume, glossopharyngeal inhalation and P(ET) O2 and P(ET) CO2 on apnea performance in trained breath-hold divers. Eur J Appl Physiol. 97 (2), 158-164 (2006).
  11. Ferretti, G. Extreme human breath-hold diving. Eur J Appl Physiol. 84 (4), 254-271 (2001).
  12. Eichhorn, L., Erdfelder, F., et al. Evaluation of near-infrared spectroscopy under apnea-dependent hypoxia in humans. J Clin Monit Comput. 29 (6), 749-757 (2015).
  13. Eichhorn, J. H. Pulse oximetry as a standard of practice in anesthesia. Anesthesiology. 78 (3), 423-426 (1993).
  14. Schewe, J. -. C., Thudium, M. O., et al. Monitoring of cerebral oxygen saturation during resuscitation in out-of-hospital cardiac arrest: a feasibility study in a physician staffed emergency medical system. Scand J Trauma Resusc Emerg Med. 22, 58 (2014).
  15. Ahn, A., Nasir, A., Malik, H., D’Orazi, F., Parnia, S. A pilot study examining the role of regional cerebral oxygen saturation monitoring as a marker of return of spontaneous circulation in shockable (VF/VT) and non-shockable (PEA/Asystole) causes of cardiac arrest. Resuscitation. 84 (12), 1713-1716 (2013).
  16. Moritz, S., Kasprzak, P., Arlt, M., Taeger, K., Metz, C. Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials. Anesthesiology. 107 (4), 563-569 (2007).
  17. Beilman, G. J., Groehler, K. E., Lazaron, V., Ortner, J. P. Near-infrared spectroscopy measurement of regional tissue oxyhemoglobin saturation during hemorrhagic shock. Shock. 12 (3), 196-200 (1999).
  18. Rhee, P., Langdale, L., Mock, C., Gentilello, L. M. Near-infrared spectroscopy: continuous measurement of cytochrome oxidation during hemorrhagic shock. Crit Care Med. 25 (1), 166-170 (1997).
  19. Zweifel, C., Castellani, G., et al. Continuous assessment of cerebral autoregulation with near-infrared spectroscopy in adults after subarachnoid hemorrhage. Stroke. 41 (9), 1963-1968 (2010).
  20. Scheeren, T. W. L., Schober, P., Schwarte, L. A. Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications. J Clin Monit Comput. 26 (4), 279-287 (2012).
  21. Boushel, R., Langberg, H., Olesen, J., Gonzales-Alonzo, J., Bülow, J., Kjaer, M. Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease. Scand J Med Sci Sports. 11 (4), 213-222 (2001).
  22. Aaslid, R. Cerebral autoregulation and vasomotor reactivity. Front Neurol Neurosci. 21, 216-228 (2006).
  23. Palada, I., Obad, A., Bakovic, D., Valic, Z., Ivancev, V., Dujic, Z. Cerebral and peripheral hemodynamics and oxygenation during maximal dry breath-holds. Respir Physiol Neurobiol. 157 (2-3), 374-381 (2007).
  24. Heusser, K., Dzamonja, G., et al. Cardiovascular regulation during apnea in elite divers. Hypertension. 53 (4), 719-724 (2009).
  25. Joulia, F., Lemaitre, F., Fontanari, P., Mille, M. L., Barthelemy, P. Circulatory effects of apnoea in elite breath-hold divers. Acta Physiol (Oxf). 197 (1), 75-82 (2009).
  26. Costalat, G., Coquart, J., Castres, I., Tourny, C., Lemaitre, F. Hemodynamic adjustments during breath-holding in trained divers. Eur J Appl Physiol. 113 (10), 2523-2529 (2013).
  27. Busch, D. R., Lynch, J. M., et al. Cerebral Blood Flow Response to Hypercapnia in Children with Obstructive Sleep Apnea Syndrome. Sleep. 39 (1), 209-216 (2016).
  28. Alex, R., Bhave, G., et al. An investigation of simultaneous variations in cerebral blood flow velocity and arterial blood pressure during sleep apnea. Conf Proc IEEE Eng Med Biol Soc. , 5634-5637 (2012).
  29. Eichhorn, L., Erdfelder, F., et al. Influence of Apnea-induced Hypoxia on Catecholamine Release and Cardiovascular Dynamics. Int J Sports Med. , (2016).
check_url/kr/54933?article_type=t

Play Video

Cite This Article
Eichhorn, L., Kessler, F., Böhnert, V., Erdfelder, F., Reckendorf, A., Meyer, R., Ellerkmann, R. K. A Model to Simulate Clinically Relevant Hypoxia in Humans. J. Vis. Exp. (118), e54933, doi:10.3791/54933 (2016).

View Video