Summary

En modell för att simulera kliniskt relevanta Hypoxi i människor

Published: December 22, 2016
doi:

Summary

Hypoxi simulering i människa har vanligtvis utförts genom inandning hypoxiska gasblandningar. För denna studie var apnéiska dykare används för att simulera dynamiska hypoxi hos människor. Dessutom har fysiologiska förändringar i desaturation och återmättnads kinetik utvärderades med icke-invasiva verktyg som nära infraröd-spektroskopi (NIRS) och perifer syresättning mättnad (SpO 2).

Abstract

In case of apnea, arterial partial pressure of oxygen (pO2) decreases, while partial pressure of carbon dioxide (pCO2) increases. To avoid damage to hypoxia sensitive organs such as the brain, compensatory circulatory mechanisms help to maintain an adequate oxygen supply. This is mainly achieved by increased cerebral blood flow. Intermittent hypoxia is a commonly seen phenomenon in patients with obstructive sleep apnea. Acute airway obstruction can also result in hypoxia and hypercapnia. Until now, no adequate model has been established to simulate these dynamics in humans. Previous investigations focusing on human hypoxia used inhaled hypoxic gas mixtures. However, the resulting hypoxia was combined with hyperventilation and is therefore more representative of high altitude environments than of apnea. Furthermore, the transferability of previously performed animal experiments to humans is limited and the pathophysiological background of apnea induced physiological changes is poorly understood. In this study, healthy human apneic divers were utilized to mimic clinically relevant hypoxia and hypercapnia during apnea. Additionally, pulse-oximetry and Near Infrared Spectroscopy (NIRS) were used to evaluate changes in cerebral and peripheral oxygen saturation before, during, and after apnea.

Introduction

Kliniskt relevant akut syrebrist och samtidig hypercapnia oftast hos patienter med obstruktiv sömnapnésyndrom (OSAS), akut luftvägsobstruktion eller under hjärt-lungräddning. Stora begränsningar inom OSAS och andra hypoxemisk villkor inkluderar begränsad överförbar kunskap om patofysiologi härrör från djurstudier och att mänskliga modeller är obefintlig en. Att efterlikna hypoxi hos människor, har hypoxiska gasblandningar hittills använts 2-7. Dessa villkor är mer representativa för hög höjd omgivning än kliniska situationer där syrebrist i allmänhet åtföljs av hyperkapni. Att övervaka vävnadsoxygenering under hjärtstillestånd och återupplivning, har djurstudier utförts 8 för att undersöka fysiologiska kompensationsmekanismer.

Apnéiska dykare är friska idrottare kan trycka andnings impulssom framkallas av låg arteriell syremättnad 9 och en ökad PCO2 10,11. Vi undersökte apnéiska dykare för att efterlikna kliniska situationer av akut syrebrist och samtidig hyperkapni 12. Denna modell kan användas för att utvärdera kliniska inställningar, förbättra den patofysiologiska förståelse av patienter med OSAS eller patologiska andningsstörningar, och avslöjar nya möjligheter för att studera en potentiell utbalansering mekanismen i fall av apné. Dessutom olika tekniker upptäcka syrebrist hos människa kan testas för genomförbarhet och noggrannhet när det gäller dynamiska hypoxi som finns i nödsituationer (dvs., luftvägshinder, laryngospasm eller kan inte intuberas, kan inte ventilera situationer) eller för att simulera intermittent hypoxi hos patienter med OSAS.

Icke-invasiva metoder för att upptäcka syrebrist hos människa är begränsad. Perifer pulsoximetri (SpO 2) är ett godkänt verktyg i pre-hospital och sjukhusmiljö för att upptäcka hypoxi 13. Metoden är baserad på ljusabsorption av hemoglobin. Dock är SpO 2 mätning begränsad till perifer arteriell syresättning och kan inte användas i fall av pulslös elektrisk aktivitet (PEA) eller centraliserad minimal cirkulation 14. I motsats härtill kan Near-Infrared Spectroscopy användas för att utvärdera cerebralt vävnadssyremättnad (RSO 2) i realtid under PEA, under hemorragisk chock eller efter subaraknoidalblödning 15-19. Dess användning växer ständigt 20 och metodstudier har visat ett positivt samband mellan SpO 2 och RSO 2 3,4.

I denna studie, ger vi en modell för att simulera kliniskt relevant hypoxi hos människor och presentera en steg-för-steg metod för att jämföra perifera pulsoximetri och NIRS vid de- och återmättnad. Genom att analysera fysiologiska data i händelse av enpnea kan vår förståelse av disk balanseringsmekanismer förbättras.

Protocol

etik uttalande Alla ingrepp i studier med mänskliga deltagare var i enlighet med de etiska normerna i 1964 Helsingforsdeklarationen och dess senare ändringar. Utformningen av denna studie har godkänts av lokala etiska kommittén för Universitetssjukhuset i Bonn, Tyskland. OBS: Se till att ämnena är i god och hälsosam kondition, utan alla blodtryckssänkande läkemedel och åtminstone 24 timmar utan katekolamin inducerande medel som koffein eller lika ämnen. 1. Framställning…

Representative Results

Figur 1 visar samtidiga inspelningar av SpO 2 och NIRS värden (NIRS cerebral och NIRS vävnad) under apné i en patient. Total apnétiden var 363 sek. Efter apné NIRS och SpO 2 värden förblev stabil under cirka 140 sekunder. En minskning av SpO 2 upptäcktes efter 204 sekunder av perifera SpO 2, medan en minskning med NIRS cerebral upptäcktes efter 238 sek. Den lägsta uppmätta SpO 2<…

Discussion

Den totala apnétiden orsakas främst av lung storlek och syreförbrukning per minut och påverkas av en individs förmåga att motstå andningsreflexen som orsakas av att öka pCO 2 eller minskar PO2. Apnea dykare är utbildade för att maximera andan håll varaktighet och används för att göra det i maximal inspiration. Därför tiden tills hypoxi är detekterbara skiljer mellan individer och beror på patientens fysiska tillstånd och utbildning status och kan även variera med deras dagliga t…

Disclosures

The authors have nothing to disclose.

Acknowledgements

Special thanks to all volunteers who participated in the original study. The work of L. Eichhorn was supported through a scholarship of the Else-Kröner-Fresenius Foundation. The authors would like to thank Springer, Part of Springer Science+Business Media, for copyright clearance (License Number 3894660871180) and the kind permission of reusing previously published data.

Materials

SpO2 Dräger Medical AG&CO.KG SHP ACC MCABLE-Masimo Set peripheral SpO2-Monitoring
Non Invasive Blood Pressure (NIBP) Dräger Medical AG&CO.KG NIBP cuff M+,  MP00916 
Electrocardiographic (ECG)   Dräger Medical AG&CO.KG Infinity M540 Monitor ECG monitoring
Docking station Dräger Medical AG&CO.KG M500 Docking Station connection of M540 to laptop
NIRS NONIN Medical’s EQUANOX Model 7600 Regional Oximeter System measuring of cerebral and  tissue oxygenation
NIRS diodes EQUANOX Advance Sensor Model 8004CA suited for measuring cerebral and somatic oxygen-saturation
Laptop 
DataGrabber Dräger Medical AG&CO.KG DataGrabber v2005.10.16 software to synchronize M540 with laptop
eVision Nonin Medical. Inc. Version 1.3.0.0 software to synchronize NONIN with laptop

References

  1. Drager, L. F., Polotsky, V. Y., O’Donnell, C. P., Cravo, S. L., Lorenzi-Filho, G., Machado, B. H. Translational approaches to understanding metabolic dysfunction and cardiovascular consequences of obstructive sleep apnea. Am J Physiol Heart Circ Physiol. 309 (7), 1101-1111 (2015).
  2. Shah, N., Trivedi, N. K., Clack, S. L., Shah, M., Shah, P. P., Barker, S. Impact of hypoxemia on the performance of cerebral oximeter in volunteer subjects. J Neurosurg Anesthesiol. 12 (3), 201-209 (2000).
  3. Ricci, M., Lombardi, P., et al. Near-infrared spectroscopy to monitor cerebral oxygen saturation in single-ventricle physiology. J Thorac Cardiovasc Surg. 131 (2), 395-402 (2006).
  4. Kusaka, T., Isobe, K., et al. Quantification of cerebral oxygenation by full-spectrum near-infrared spectroscopy using a two-point method. Comp Biochem Physiol A Mol Integr Physiol. 132 (1), 121-132 (2002).
  5. Nishimura, N., Iwasaki, K., Ogawa, Y., Shibata, S. Oxygen administration, cerebral blood flow velocity, and dynamic cerebral autoregulation. Aviat Space Environ Med. 78 (12), 1121-1127 (2007).
  6. Wilson, M. H., Newman, S., Imray, C. H. The cerebral effects of ascent to high altitudes. Lancet Neurol. 8 (2), 175-191 (2009).
  7. Sanborn, M. R., Edsell, M. E., et al. Cerebral hemodynamics at altitude: effects of hyperventilation and acclimatization on cerebral blood flow and oxygenation. Wilderness Environ Med. 26 (2), 133-141 (2015).
  8. Reynolds, J. C., Salcido, D., et al. Tissue oximetry by near-infrared spectroscopy in a porcine model of out-of-hospital cardiac arrest and resuscitation. Resuscitation. 84 (6), 843-847 (2013).
  9. Andersson, J. P. A., Evaggelidis, L. Arterial oxygen saturation and diving response during dynamic apneas in breath-hold divers. Scand J Med Sci Sports. 19 (1), 87-91 (2009).
  10. Overgaard, K., Friis, S., Pedersen, R. B., Lykkeboe, G. Influence of lung volume, glossopharyngeal inhalation and P(ET) O2 and P(ET) CO2 on apnea performance in trained breath-hold divers. Eur J Appl Physiol. 97 (2), 158-164 (2006).
  11. Ferretti, G. Extreme human breath-hold diving. Eur J Appl Physiol. 84 (4), 254-271 (2001).
  12. Eichhorn, L., Erdfelder, F., et al. Evaluation of near-infrared spectroscopy under apnea-dependent hypoxia in humans. J Clin Monit Comput. 29 (6), 749-757 (2015).
  13. Eichhorn, J. H. Pulse oximetry as a standard of practice in anesthesia. Anesthesiology. 78 (3), 423-426 (1993).
  14. Schewe, J. -. C., Thudium, M. O., et al. Monitoring of cerebral oxygen saturation during resuscitation in out-of-hospital cardiac arrest: a feasibility study in a physician staffed emergency medical system. Scand J Trauma Resusc Emerg Med. 22, 58 (2014).
  15. Ahn, A., Nasir, A., Malik, H., D’Orazi, F., Parnia, S. A pilot study examining the role of regional cerebral oxygen saturation monitoring as a marker of return of spontaneous circulation in shockable (VF/VT) and non-shockable (PEA/Asystole) causes of cardiac arrest. Resuscitation. 84 (12), 1713-1716 (2013).
  16. Moritz, S., Kasprzak, P., Arlt, M., Taeger, K., Metz, C. Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials. Anesthesiology. 107 (4), 563-569 (2007).
  17. Beilman, G. J., Groehler, K. E., Lazaron, V., Ortner, J. P. Near-infrared spectroscopy measurement of regional tissue oxyhemoglobin saturation during hemorrhagic shock. Shock. 12 (3), 196-200 (1999).
  18. Rhee, P., Langdale, L., Mock, C., Gentilello, L. M. Near-infrared spectroscopy: continuous measurement of cytochrome oxidation during hemorrhagic shock. Crit Care Med. 25 (1), 166-170 (1997).
  19. Zweifel, C., Castellani, G., et al. Continuous assessment of cerebral autoregulation with near-infrared spectroscopy in adults after subarachnoid hemorrhage. Stroke. 41 (9), 1963-1968 (2010).
  20. Scheeren, T. W. L., Schober, P., Schwarte, L. A. Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications. J Clin Monit Comput. 26 (4), 279-287 (2012).
  21. Boushel, R., Langberg, H., Olesen, J., Gonzales-Alonzo, J., Bülow, J., Kjaer, M. Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease. Scand J Med Sci Sports. 11 (4), 213-222 (2001).
  22. Aaslid, R. Cerebral autoregulation and vasomotor reactivity. Front Neurol Neurosci. 21, 216-228 (2006).
  23. Palada, I., Obad, A., Bakovic, D., Valic, Z., Ivancev, V., Dujic, Z. Cerebral and peripheral hemodynamics and oxygenation during maximal dry breath-holds. Respir Physiol Neurobiol. 157 (2-3), 374-381 (2007).
  24. Heusser, K., Dzamonja, G., et al. Cardiovascular regulation during apnea in elite divers. Hypertension. 53 (4), 719-724 (2009).
  25. Joulia, F., Lemaitre, F., Fontanari, P., Mille, M. L., Barthelemy, P. Circulatory effects of apnoea in elite breath-hold divers. Acta Physiol (Oxf). 197 (1), 75-82 (2009).
  26. Costalat, G., Coquart, J., Castres, I., Tourny, C., Lemaitre, F. Hemodynamic adjustments during breath-holding in trained divers. Eur J Appl Physiol. 113 (10), 2523-2529 (2013).
  27. Busch, D. R., Lynch, J. M., et al. Cerebral Blood Flow Response to Hypercapnia in Children with Obstructive Sleep Apnea Syndrome. Sleep. 39 (1), 209-216 (2016).
  28. Alex, R., Bhave, G., et al. An investigation of simultaneous variations in cerebral blood flow velocity and arterial blood pressure during sleep apnea. Conf Proc IEEE Eng Med Biol Soc. , 5634-5637 (2012).
  29. Eichhorn, L., Erdfelder, F., et al. Influence of Apnea-induced Hypoxia on Catecholamine Release and Cardiovascular Dynamics. Int J Sports Med. , (2016).
check_url/kr/54933?article_type=t

Play Video

Cite This Article
Eichhorn, L., Kessler, F., Böhnert, V., Erdfelder, F., Reckendorf, A., Meyer, R., Ellerkmann, R. K. A Model to Simulate Clinically Relevant Hypoxia in Humans. J. Vis. Exp. (118), e54933, doi:10.3791/54933 (2016).

View Video