JoVE 비디오를 활용하시려면 도서관을 통한 기관 구독이 필요합니다.  전체 비디오를 보시려면 로그인하거나 무료 트라이얼을 시작하세요.
Drosophila Egg Collection and Dechorionation: A Method to Remove the Outermost Egg Layer

Drosophila Egg Collection and Dechorionation: A Method to Remove the Outermost Egg Layer

내레이션 대본

Allow Drosophila 세스 lay eggs overnight onto a dish containing agar supplemented with grape juice 세스 visualize eggs and coated with yeast 세스 encourage flies 세스 mate and lay eggs. To remove the eggs, add distilled water 세스 the dish and gently wipe the surface with a paintbrush. Then pour the mixture through a nylon mesh placed in a plastic bushing 세스 collect the eggs. Soak the eggs in two rounds of 7% bleach 세스 remove the chorion, or protective outer layer, from the embryo. This process is called dechorionation.

The eggs are now stuck 세스 the side of the bushing. Wash them three times with water 세스 remove the bleach. Finally, use a paintbrush 세스 transfer the eggs from the bushing 세스 vials 세스 continue development or for immediate use in an experiment. In the example protocol, we will collect and dechorionate Drosophila eggs under sterile conditions 세스 rear flies with defined microbiota.

Place nylon mesh into a plastic bushing 세스 prepare the sieve for egg collection. If the same flies will be used the next day, immediately transfer them 세스 a new cage containing freshly yeasted grape juice agar plates. The grape juice plate in the previous cage contains the fruit fly eggs. Remove dead flies with a clean paintbrush, and take caution not 세스 break up the agar. Rinse the agar plate with distilled water and gently brush the eggs from the agar’s surface then pour the slurry over the mesh 세스 collect the eggs.

Sterilize the biosafety cabinet with 70% ethanol then turn on the UV light. Spray all non-biological supplies with 70% ethanol and immediately place them in the biosafety cabinet, then sterilize them with UV light.

It is critical 세스 ensure that good aseptic technique is practiced when working within or when adding or removing new materials 세스 the biosafety cabinet.

Transfer the bushing with the eggs into a 120-milliliter specimen cup and slowly pour 90 milliliters of 0.6% sodium hypochlorite solution, or 7% bleach, into the bushing, just below the rim. Using forceps, periodically move the bushing up and down in the solution 세스 resuspend the eggs. Transfer the bushing directly into a second specimen cup pre-filled with 90 milliliters of bleach.

At the end of the second bleach treatment, the eggs should begin 세스 adhere 세스 the sides of the bushing. Discard the bleach and completely rinse the bushing with sterile water. Again, use forceps 세스 resuspend the egg several times during each wash. By the end of the third wash, most eggs should be attached 세스 the side of the bushing.

Using a sterile paintbrush, transfer the eggs from the side of the bushing 세스 the sterile diet. Leave the caps loose 세스 allow oxygen 세스 enter the tube. The transferred eggs will be visible on the surface of the diet.

Related Videos

Read Article