A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

An Assay to Measure Chemically-Induced Cytotoxicity in Human Precision-Cut Lung Slices

1K views

⸱

July 8th, 2025

In This Article

Abstract

Source: Neuhaus, V. et al., Assessment of the Cytotoxic and Immunomodulatory Effects of Substances in Human Precision-cut Lung Slices. J. Vis. Exp. (2018)

This video illustrates a technique for evaluating cytotoxicity in human precision-cut lung slices through the WST-1 assay. Human precision-cut lung slices are subjected to incremental concentrations of a cytotoxic chemical to quantify their cytotoxicity. A decrease in color intensity serves as confirmation of the chemical's detrimental impact on lung cells.

Protocol

All procedures involving sample collection have been performed in accordance with the institute's IRB guidelines.

1. General Preparation of Human precision-cut lung slices (PCLS) and Subsequent Exposure to Chemicals

NOTE: Two persons are required to fill a lung. An up-to-date vaccination record for hepatitis A and B is recommended. Patients are routinely screened for hepatitis C virus (HCV) and human immunodeficiency virus (HIV) prior to lung transplantation. If an active infection with Mycobacterium tuberculosis is diagnosed or suspected, the lung should be reje....

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Silicon hose 3.0 x 5.0 mmA. Hartenstein (Leipzig, Germany)SS04
SyringeFaust Lab Science (Klettgau, Germany)9.410 050
Coring toolscustom-madecustom-made
Trimming Blade Handle (FEATHER)pfm medical ag  (Cologne, Germany)205530001
Trimming Blades (FEATHER)pfm medical ag  (Cologne, Germany)205500000
Microtome: Tissue SlicerAlabama R&D (Bad Homburg, Germany)303400-ADPTKrumdieck Tissue Slicer (MD6000)
Microtome bladeWilkinson Sword (Solingen, Germany)ENR-4027800011506
Cell strainer filter (100 µm Nylon)Becton Dickinson (Heidelberg, Germany)BD352360
Inoculation loopCopan Diagnostics (Murrieta, USA) CD176S01
TPP Tissue culture plates 24wellsSigma (München, Germany)Z707791-126EA
Nunc MaxiSorp flat-bottomFisher Scientific GmbH (Hannover, Germany)44-2404-21
Nunc MicroWell 96-Well Thermo Scientific (Schwerte, Germany)260836
Multiwell-ReaderTecan Group Ltd. (Männedorf, Switzerland)Tecan infinite F200ProPlate Reader
Plate shakerEdmund Buehler GmbH (Hechingen, Germany)KM-2 Akku
Assays
Cell Proliferation Reagent WST-1Roche (Basel, Switzerland)11644807001
Reagents
Agarose, low gelling temperature Sigma (München, Germany)A9414-100G
Balanced Salt Mixtures and Solutions, Cell Culture, Classic Media and Salts, Earle's Balanced Salts (EBSS)Sigma (München, Germany)E2888-500ML
Penicillin and streptomycinLonza (Verviers, Belgium)17-602E
Dulbecco´s Modified Eagle´s Medium Nutrient Mixture F-12 Ham (DMEM F-12)Gibco (Darmstadt, Germany)11039-047Culture medium
Dulbecco´s Phosphate with Ca and Mg (DPBS)Lonza (Verviers, Belgium)BE17-513F  Buffer solution
DetergentSigma (Saint Louis, USA)X100-100MLTriton X-100

Explore More Articles

WST-1 AssayCytotoxicity MeasurementTest Agent ConcentrationFormazan AbsorbanceMicroplate ReaderOrbital ShakerTissue ViabilityCell Membrane DisruptionMetabolically Active Cells