Summary

In Situ Påvisning af autoreaktive CD4 T-celler i hjernen og hjertet Brug hovedhistokompatibilitetskompleks klasse II Dextramers

Published: August 01, 2014
doi:

Summary

Protokollen til påvisning selvnedbrydende CD4 T-celler i hjernen og hjertet ved direkte farvning med større histokompatibilitetskompleks klasse II dextramers er blevet beskrevet i denne rapport. For omfattende analyse, en pålidelig metode til at opregne de frekvenser af antigen-specifikke CD4 + T-celler i situ også udtænkt.

Abstract

This report demonstrates the use of major histocompatibility complex (MHC) class II dextramers for detection of autoreactive CD4 T cells in situ in myelin proteolipid protein (PLP) 139-151-induced experimental autoimmune encephalomyelitis (EAE) in SJL mice and cardiac myosin heavy chain-α (Myhc) 334-352-induced experimental autoimmune myocarditis (EAM) in A/J mice. Two sets of cocktails of dextramer reagents were used, where dextramers+ cells were analyzed by laser scanning confocal microscope (LSCM): EAE, IAs/PLP 139-151 dextramers (specific)/anti-CD4 and IAs/Theiler’s murine encephalomyelitis virus (TMEV) 70-86 dextramers (control)/anti-CD4; and EAM, IAk/Myhc 334-352 dextramers/anti-CD4 and IAk/bovine ribonuclease (RNase) 43-56 dextramers (control)/anti-CD4. LSCM analysis of brain sections obtained from EAE mice showed the presence of cells positive for CD4 and PLP 139-151 dextramers, but not TMEV 70-86 dextramers suggesting that the staining obtained with PLP 139-151 dextramers was specific. Likewise, heart sections prepared from EAM mice also revealed the presence of Myhc 334-352, but not RNase 43-56-dextramer+ cells as expected. Further, a comprehensive method has also been devised to quantitatively analyze the frequencies of antigen-specific CD4 T cells in the ‘Z’ serial images.

Introduction

Anvendelse af større histokompatibilitetskompleks (MHC) klasse II tetramerer til påvisning af antigen-specifikke CD4-T-celler har været en udfordring 1-7. For at forbedre afsløring følsomhed MHC klasse II tetramers har forskerholdet skabt næste generations tetramere udpeget "dextramers" 8. Dextramers indeholder dextran rygrade hvor flere streptavidin-fluoroforen dele er konjugeret, således at adskillige peptid-bundne, biotinylerede MHC-monomerer kan være knyttet til en dextranmolekyle 9. Således kan store aggregater af MHC dextramers som indeholder flere MHC-peptid-komplekser interagerer med flere T-cellereceptorer (TCR'er).

Denne gruppe nyligt genererede dextramers for forskellige selvantigener og viste, at påvisning følsomhed dextramers var cirka fem gange mere end tetramere 8. De eksperimentelle systemer omfatter eksperimentel autoimmun encephalomyelitis (EAE) induceret med proteolipidprotein (PLP) 139-151 i SJL-mus; EAE induceret med myelin oligodendrocyt glycoprotein (MOG) 35-55 i C57BL / 6 mus; og eksperimentel autoimmun myocarditis (EAM) induceret med kardial myosin tung kæde-α (MyHC) 334-352 i A / J-mus. Denne undersøgelse viser anvendelsen af PLP 139-151 – og MyHC 334-352 dextramers at detektere antigenspecifikke CD4 T-celler in situ med specificitet ved at udvikle en direkte farvningsprotokol, hvorved behovet for at forstærke signalerne fra at bruge fluoroforen antistoffer, en nærmer almindeligvis anvendes med brug af tetramerer. Derudover har en omfattende metode til at evaluere væv også blevet udtænkt til pålideligt opregne de frekvenser af antigen-specifikke CD4 T-celler i situ 10. Påvisning af antigen-specifikke T-celler in situ muliggør afgrænsning af begivenheder forårsaget af specifikke antigene stimuli fra dem, der forårsages af bystander-aktivering. Ligeledes in situ teknik også provides muligheder for at spore kinetikken af ​​antigen-specifikke T-celle infiltrationer i målorganer.

Protocol

Etiske retningslinjer: Alle animalske procedurer blev gennemført i overensstemmelse med de retningslinjer for pasning og anvendelse af forsøgsdyr og godkendt af University of Nebraska-Lincoln, Lincoln, NE. 1. Induktion af EAE For at inducere EAE forberede peptid / komplet Freunds adjuvans (CFA) emulsion som beskrevet i 11 med de følgende modifikationer: Trin 1.1:. Forberede PLP 139-151 ved en koncentration på 1 mg / ml i 1X phosph…

Representative Results

I denne rapport er in situ påvisning af antigen-specifikke, autoreaktive CD4 T-celler ved direkte farvning med MHC klasse II dextramers beskrevet. Nyslået cerebrale sektioner blev afledt fra EAE-mus og farves med cocktails indeholdende PLP 139-151 (specifik) eller TMEV 70-86 (kontrol) dextramers og anti-CD4. De øverste paneler i Figur 1 viser LSCM analyse af cerebrale costained med PLP 139-151 dextramers (rød) og CD4-antistof (grøn), hvor dobbelt-positive celler syntes gul. En sådan funkt…

Discussion

I modsætning til MHC klasse I-tetramerer, anvendelse af MHC klasse II-tetramerer til rutinemæssig anvendelse er fortsat udfordrende, især at opregne de precursor-frekvenser med lav affinitet autoreaktive CD4 T-celler, til dels skyldes deres aktivering afhængighed 6,15-17. For nylig blev dette problem omgået ved at skabe den næste generation af tetramere, kaldet "dextramers", tillader os at opdage antigen-specifikke CD4 T-celler for en række autoantigener, såsom PLP 139-151, MOG 35-55 og MyHC…

Declarações

The authors have nothing to disclose.

Acknowledgements

Dette arbejde blev støttet af American Heart Association og Børnenes Kardiomyopati Foundation (SDG2462390204001), og National Institutes of Health (HL114669). CM er en modtager af en postdoc stipendium tildelt af myocarditis Foundation, NJ.

Materials

CFA Sigma Aldrich, St Louis, MO 5881 Store at 4οC
MTB  H37Rv extract  Difco Laboratories, Detroit, MI 231141 Store at 4οC
PT List Biologicals Laboratories, Campbell, CA 181 Store at 4οC
1x PBS  Corning, Manassas, VA 21-040-CV Store at 4οC
Female A/J mice  Jackson Laboratories, Bar Harbor, ME 646
Female SJL/J mice Jackson Laboratories, Bar Harbor, ME 686
Leur-lok sterile 1 ml syrringe BD, Franklin Lakes, NJ 309628
Leur-lok sterile 3 ml syrringe BD, Franklin Lakes, NJ 309657
Sterile needle, 18 G BD, Franklin Lakes, NJ 305195
Sterile needle, 27 1/2 G BD, Franklin Lakes, NJ 305109
3-way stopcock  Smiths Medical ASD, Inc. Dublin, OH MX5311L
Kerlix gauze bandage rolls  Covidien, Mansfield, MA 6720
Kimwipes Kimberly-Clark Professional, Roswell, GA 34155
Agarose, Low Melting Point, Analytical Grade Promega corporation, Madison, WI V2111
Immunopure normal goat serum Thermo Scientific, Waltham, MA 31873 Store at -20 οC
Anti-mouse CD4 conjugated with PE dye eBioscience, San Diego, CA  12004185 Store at 4οC
Paraformaldehyde Electron Microscopy Sciences, Hatfield, PA 19202 Store at 4οC
Faramount Aqueous Mounting Medium Dako, Carpinteria, CA 10073021
Conical tube (15ml) BD Biosciences, San Jose, CA 352099
Conical tube (50 ml) BD Biosciences, San Jose, CA 352070
24-well flat bottomed tissue culture plates BD Biosciences, San Jose, CA 356775
Water color #2 brushes Charles Leonard, Inc. Hauppauge, NY 73502
Plain Microscope slides, size: 3" x 1" x 1.2 mm Fisher Scientific, Pittsburgh, PA 1255010
Premium Cover glass, 22 x 22-1 Fisher Scientific, Pittsburgh, PA 12548B
Disposable deep base mold histology cassettes Laboratory prodcust, Rochester, NY M-475-10
Loctite Super glue Henkel Corporation, Westlake, OH 1471879
Razor blades Gillette SuperSilver
Myhc-a 334-352 (DSAFDVLSFTAEEKAGVYK) Neopeptide, Cambridge, MA Store at 4οC
PLP 139-151 (HSLGKWLGHPDKF) Neopeptide, Cambridge, MA Store at 4οC
MHC class II/IAs PLP 139-151 or TMEV 70-86 dextramers conjugated with APC dye Store at 4οC
MHC class II/IAk Myhc 334-352 or  or RNase 40-56 dextramers conjugated with APC dye Store at 4οC
Dextran conjugated SA-APC  Immundex, Copenhagen, Demark Store at 4οC
Sterile surgical scissors and forceps INOX tool Corporation
Micro oven GE Healthcare, Pittsuburgh, PA
Leica VT 1200 Vibratome Leica Microsystems, Inc. Buffalo Grove, IL
Olympus BX 60  Laser scanning confocal microscope Olympus America, Inc. Center Valley, PA
Nikon A1-Eclipse 90i confocal microscope Nikon Inc. Melville, NY

Referências

  1. Cecconi, V., Moro, M., Del Mare, ., Dellabona, S., P, G., Casorati, Use of MHC class II tetramers to investigate CD4+ T cell responses: problems and solutions. Cytometry A. 73 (11), 1010-1018 (2008).
  2. Ferlin, W., Glaichenhaus, N., Mougneau, E. Present difficulties and future promise of MHC multimers in autoimmune exploration. Curr Opin Immunol. 12, 670-675 (2000).
  3. Kwok, W. W., Ptacek, N. A., Liu, A. W., Buckner, J. H. Use of class II tetramers for identification of CD4+ T cells. J Immunol Methods. 268, 71-81 (2002).
  4. Landais, E., et al. New design of MHC class II tetramers to accommodate fundamental principles of antigen presentation. J Immunol. 183, 7949-7957 (2009).
  5. Nepom, G. T. MHC class II tetramers. J Immunol. 188, 2477-2482 (2012).
  6. Vollers, S. S., Stern, L. J. Class II major histocompatibility complex tetramer staining: progress, problems, and prospects. Immunology. 123, 305-313 (2008).
  7. Wooldridge, L., et al. Tricks with tetramers: how to get the most from multimeric peptide-MHC. Immunology. 126, 147-164 (2009).
  8. Massilamany, C., Upadhyaya, B., Gangaplara, A., Kuszynski, C., Reddy, J. Detection of autoreactive CD4 T cells using major histocompatibility complex class II dextramers. BMC Immunol. 12, 1471-2172 (2011).
  9. Batard, P., et al. Dextramers: new generation of fluorescent MHC class I/peptide multimers for visualization of antigen-specific CD8+ T cells. J Immunol Methods. 310 (1-2), 136-148 (2006).
  10. Massilamany, C., Gangaplara, A., Jia, T., et al. Direct staining with major histocompatibility complex class II dextramers permits detection of antigen-specific, autoreactive CD4 T cells in situ. PLoS One. 9 (1), (2014).
  11. Massilamany, C., Khalilzad-Sharghi, V., Gangaplara, A., Steffen, D., Othman, S. F., Reddy, J. Noninvasive Assessment of Cardiac Abnormalities in Experimental Autoimmune Myocarditis by Magnetic Resonance Microscopy Imaging in the Mouse. J Vis Exp. (88), e51654 (2014).
  12. Massilamany, C., Steffen, D., Reddy, J. An epitope from Acanthamoeba castellanii that cross-react with proteolipid protein 139-151-reactive T cells induces autoimmune encephalomyelitis in SJL mice. J Neuroimmunol. 219 (1-2), 17-24 (2010).
  13. Donermeyer, D. L., Beisel, K. W., Allen, P. M., Smith, S. C. Myocarditis-inducing epitope of myosin binds constitutively and stably to I-Ak on antigen-presenting cells in the heart. J Exp Med. 182 (5), 1291-1300 (1995).
  14. Liao, L., Sindhwani, R., Leinwand, L., Diamond, B., Factor, S. Cardiac alpha-myosin heavy chains differ in their induction of myocarditis. Identification of pathogenic epitopes. J Clin Invest. 92 (6), 2877-2882 (1993).
  15. Cameron, T. O., Cochran, J. R., Yassine-Diab, B., Sekaly, R. P., Stern, L. J. Cutting edge: detection of antigen-specific CD4+ T cells by HLA-DR1 oligomers is dependent on the T cell activation state. J Immunol. 166 (2), 741-745 (2001).
  16. Novak, E. J., et al. Activated human epitope-specific T cells identified by class II tetramers reside within a CD4high, proliferating subset. Int Immunol. 13 (6), 799-806 (2001).
  17. Reddy, J., et al. Detection of autoreactive myelin proteolipid protein 139-151-specific T cells by using MHC II (IAs) tetramers. J Immunol. 170 (2), 870-877 (2003).
  18. Skinner, P. J., Daniels, M. A., Schmidt, C. S., Jameson, S. C., Haase, A. T. Cutting edge: In situ tetramer staining of antigen-specific T cells in tissues. J Immunol. 165 (2), 613-617 (2000).
  19. Skinner, P. J., Haase, A. T. In situ tetramer staining. J Immunol Methods. 268 (1), 29-34 (2002).
  20. Skinner, P. J., Haase, A. T. In situ staining using MHC class I tetramers. Curr Protoc Immunol. Chapter 17, Unit 17.14.11 (2004).
check_url/pt/51679?article_type=t

Play Video

Citar este artigo
Massilamany, C., Gangaplara, A., Jia, T., Elowsky, C., Li, Q., Zhou, Y., Reddy, J. In Situ Detection of Autoreactive CD4 T Cells in Brain and Heart Using Major Histocompatibility Complex Class II Dextramers. J. Vis. Exp. (90), e51679, doi:10.3791/51679 (2014).

View Video