Summary

マウス腎臓移植:同種移植片拒絶のモデル

Published: October 11, 2014
doi:

Summary

Here, we present a protocol to study the immunology of rejection. The surgical model presented reports a short operating time and a concise technique. Depending on the donor-recipient strain combination, the transplanted kidney may develop acute cellular rejection or chronic allograft damage, defined by interstitial fibrosis and tubular atrophy.

Abstract

Rejection of the transplanted kidney in humans is still a major cause of morbidity and mortality. The mouse model of renal transplantation closely replicates both the technical and pathological processes that occur in human renal transplantation. Although mouse models of allogeneic rejection in organs other than the kidney exist, and are more technically feasible, there is evidence that different organs elicit disparate rejection modes and dynamics, for instance the time course of rejection in cardiac and renal allograft differs significantly in certain strain combinations. This model is an attractive tool for many reasons despite its technical challenges. As inbred mouse strain haplotypes are well characterized it is possible to choose donor and recipient combinations to model acute allograft rejection by transplanting across MHC class I and II loci. Conversely by transplanting between strains with similar haplotypes a chronic process can be elicited were the allograft kidney develops interstitial fibrosis and tubular atrophy. We have modified the surgical technique to reduce operating time and improve ease of surgery, however a learning curve still needs to be overcome in order to faithfully replicate the model. This study will provide key points in the surgical procedure and aid the process of establishing this technique.

Introduction

腎不全の治療のために成功した腎移植は、まずそれ以来、人生2の長さと品質の両方で改善を提供し、世界中の末期腎不全患者のための革新的な治療法となっており、1一卵性双生児の間で1955年に記載された。しかし長期的な移植片の生存は、慢性同種移植片損傷3をもたらし病理学的プロセスの多数によって妨げられてきた。

ヒトでの移植された腎臓の拒絶はimmunosupporessiveレジメンの大幅な改善にもかかわらず、罹患率の主要な原因である。腎移植のマウスモデルを開発の目的は密接にヒト腎移植4で見つかったプロセスおよび病理を複製することである。 Skoskiewicz らは、最初に1973年5において腎移植のマウスモデルを説明した。高度な顕微スキルが必要とされているが、それは価値のあるtといくつかの理由からOOL:マウスゲノムは、十分に特徴付けられており、実験方法とマウスの研究のために利用可能な技術の多種多様があります。

腎移植のマウスモデルを使用して多くのグループがしかし、実験4の期間中、 その場に放置されている他の研究でレシピエントマウスのネイティブ腎臓の私達の記載された方法論1で、生命維持器官などの移植された腎臓を使用している。利点は、マウスが、それによって、マウスへの罹患率と第二の手順による死亡のリスクを低減シングル麻酔して、操作を受けるということです。さらにマウスが緩やかな腎不全の悪影響を受けない。

同種異系拒絶のモデルは、心臓、皮膚などの他の臓器に存在するが、これらは常に腎移植とは直接関係ありません。これらのモデルは、異なるモードとdyを誘発するという証拠がある拒絶反応のナミックスは、例えば、心臓同種移植、腎同種移植における拒絶反応の時間的経過は、特定の菌株の組み合わせ6で大幅に異なっている。私たちは、非トランスジェニックFVB / NJマウスにBALB / c系ドナーにおいて急性腎同種移植片拒絶反応パターンを記載して、このモデルは、T細胞およびマクロファージ7の蓄積による細胞媒介性傷害を示した。代替的に、私たちはまた、間質性線維症および尿細管萎縮を示し、慢性の同種移植片損傷のモデルを記載したこれらのマウスは、単一のMHCクラスII遺伝子座のミスによって特徴付けられるように、これは、C57BL / 6レシピエントにC57BL / 6 BM12ドナーからの腎臓移植から生じる-match 8。

移植の複数の態様は、急性拒絶反応、細胞性および体液性拒絶反応、虚血再灌流障害、および新規治療薬を試用を含む腎移植のマウスモデルを用いて研究されている。 私たちは、外科トンを変更した運転時間を短縮し、手術の容易性を向上させるechnique。特に、私たちは、同時ドナーとレシピエントの準備および連続大動脈パッチ吻合を利用することによって単純化された血管吻合技術を記載している。このビデオと原稿が、この技術の確立を支援するために重要なポイントを提供します。

Protocol

適切な国や地方の機関倫理、動物実験を行う前になされるべきである。受信者の外科医は2.1 2.8に出演しながら、具体的に、英国で以下の実験は、ドナー外科医が行うべき2 microsurgeonsが同時に動作するために利用可能である動物(科学的手続)法1986の下で実施された、1.1から1.16、その後3.1から3.5のステップ。一人のオペレータのためのステップを順次追跡することができる。 <p class="jove_ti…

Representative Results

腎臓の同種移植片拒絶は、移植された腎臓( 図2)のmethacarn固定パラフィン包埋組織切片の組織学的分析によって評価することができる。腎臓の虚血再灌流障害における同系マウスの結果の間に腎臓の同系移植移植は、しかし、4週間までに細管を回収し、ネイティブの腎臓への組織学的に同等であるしている。急性拒絶反応は、BALB / cレシピエントにC57BL / 6腎臓移植によってモデ…

Discussion

動脈吻合を実行するために、最もよく説明した方法は、受信者の大動脈にエンド·ツー·サイド方式では、継続中の腎動脈に、ドナーの遠位大動脈を使用することです。私たちは、より便利であると私たちは信じている人間の腎臓移植​​で行われる「カレルパッチ」ミラーリングと同様、大動脈パッチの使用を記載している。ドナーとレシピエント手術時間の文献の報告が疎であるが、私た…

Declarações

The authors have nothing to disclose.

Acknowledgements

腎臓研究英国、エジンバラの外科ロイヤルカレッジと臓器移植の欧州協会からの資金調達は、この研究を支持した。

Materials

Surgical Instruments
Blunt Dissecting Scissors Fine Science Tools  14072-10 For skin cutting
Curved Castoviejo scissors Fine Science Tools 15017-10 For tissue cutting
Spring Scissors – straight Fine Science Tools 15000-08 For suture cutting
Toothed forceps 1×2 teeth Fine Science Tools 11021-12
2 x Fine Tip forceps (Dumont No.5) Fine Science Tools 11251-20
Angled Fine Tip forceps (Dumont No. 5/45) Fine Science Tools 11253-25 For blunt dissecting
Curved Fine Tip forcep (Dumont No.7) Fine Science Tools 11273-22 Useful to pass around vessels
Curved Crile Haemostat Fine Science Tools 1300-04
Micro clip applicator with lock Fine Science Tools 18056-14
2 x Micro serrefines spring width 2mm, jaw length 4mm Fine Science Tools 18055-04 Microvascular clamps
2 x Colibri 3cm wire retractor Fine Science Tools 17000-03
Castroviejo needle holder with lock Fine Science Tools 120660-01
Wound clip applicator Fine Science Tools 12031-07
7mm wound clips Fine Science Tools 12032-07 Remove 7 to 10 days after surgery
Equipment
OPMI pico microscope Carl Zeiss S100
Thermal cautery unit with fine tip Geiger 150A
Heat electronic pad Cozee Cumfort n/a
Euroklav 23-S Melag n/a Autoclave
Disposable equipment
7/O Silk braided suture Pearsall 30514
10/O Dafilon (polyamide) suture B-Braun  G1118099
6/O Vicryl (plygalectin) Ethicon W9537
Regular bevel needle, 1 inch, 21G Bection, Dickinson and Company 305175 For ureteric anastamosis
Regular bevel needle, 5/8 inch, 25G Bection, Dickinson and Company 305122
Regular bevel needle, 1/2 inch, 30G Bection, Dickinson and Company 304000
Insulin needle 1ml, 29G Bection, Dickinson and Company 324827
Insulin needle 0.3ml, 30G Bection, Dickinson and Company 324826
1 ml syringe slip tip Bection, Dickinson and Company 300184
5 ml syringe slip tip Bection, Dickinson and Company 302187
Wypall paper swabs Kimberley-Clark L40 sterilised by autoclave
Cotton wool buds Johnson and Johnson n/a sterilised by autoclave
Plain drapes Guardian CB03 sterilised by autoclave
Cell culture dish 60mm x 15mm Corning Incorporated 430166
Dispensing Pin B-Braun DP3500L / 413501 Used with NaCl 0.9%
Re-agents and Drugs
(Lacri-Lube) White soft paraffin 57.3%, mineral oil 42.5% and lanolin alcohols 0.2% Allergan Ltd 21956GB10X
(Videne) Povidone-iodine 10% Ecolab Ltd PL 04509/0041
(Vetalar V) Ketamine hydrochloride Pfizer Animal Health Vm 42058/4165 100mg/ml solution (dose 200mg/kg)
(Domitor) Medetomidine hydrochloride  Orion Pharma Vm 06043/4003 1mg/ml (dose 0.5mg/kg)
(Vetergesic) Bupernorphine hydrochloride  Alsto Animal Health Vm 00063/4002 0.3mg/ml (dose 0.05mg/kg)
(Antisedan) Atipamezole hydrochoride Orion Pharma Vm 06043/4004 5mg/ml (dose 2mg/kg)
University of Wisconsin Solution Belzer Bridge to Life n/a dose approximately 500 microlitres/mouse
NaCl 0.9% Baxter FKE1323
Heparin Sulphate non-proprietary n/a 5000units/ml (dose 5units/mouse)

Referências

  1. Guild, W. R., Harrison, J. H., Merrill, J. P., Murray, J. Successful homotransplantation of the kidney in an identical twin. Trans. Am. Clin. Climatol Assoc. 67, 167-173 (1955).
  2. Wolfe, R. A., et al. Comparison of mortality in all patients on dialysis, patients on dialysis awaiting transplantation, and recipients of a first cadaveric transplant. N. Engl. J. Med. 341, 1725-1730 (1999).
  3. Nankivell, B. J., Alexander, S. I. . Rejection of the Kidney Allograft. N. Engl. J. Med. 363, 1451-1462 (2010).
  4. Tse, G. H., Hughes, J., Marson, L. P. Systematic review of mouse kidney transplantation. Transplant International. 26, 1149-1160 (2013).
  5. Skoskiewicz, M., Chase, C., Winn, H. J., Russell, P. S. Kidney transplants between mice of graded immunogenetic diversity. Transplant. Proc. 5, 721-725 (1973).
  6. Zhang, Z., et al. Pattern of liver, kidney, heart, and intestine allograft rejection in different mouse strain combinations. Transplantation. 62, 1267-1272 (1996).
  7. Qi, F., et al. Depletion of cells of monocyte lineage prevents loss of renal microvasculature in murine kidney transplantation. Transplantation. 86, 1267-1274 (2008).
  8. Dang, Z., Mackinnon, A., Marson, L. P., Sethi, T. Tubular atrophy and interstitial fibrosis after renal transplantation is dependent on galectin-3. Transplantation. 93, 477-484 (2012).
  9. Jabs, W. J., et al. Heterogeneity in the Evolution and Mechanisms of the Lesions of Kidney Allograft Rejection in Mice. Am. J. Transplant. 3, 1501-1509 (2003).
  10. Lin, T., et al. Deficiency of C4 from Donor or Recipient Mouse Fails to Prevent Renal Allograft Rejection. Am. J. Pathol. 168, 1241-1248 (2006).
check_url/pt/52163?article_type=t

Play Video

Citar este artigo
Tse, G. H., Hesketh, E. E., Clay, M., Borthwick, G., Hughes, J., Marson, L. P. Mouse Kidney Transplantation: Models of Allograft Rejection. J. Vis. Exp. (92), e52163, doi:10.3791/52163 (2014).

View Video