Summary

Contraste Dinâmico aprimorada Ressonância Magnética de um Modelo de câncer de pâncreas Orthotopic Rato

Published: April 18, 2015
doi:

Summary

The goal of this protocol is to apply dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) for orthotopic pancreatic tumor xenografts in mice. DCE-MRI is a non-invasive method to analyze microvasculature in a target tissue, and useful to assess vascular response in a tumor following a novel therapy.

Abstract

Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) has been limitedly used for orthotopic pancreatic tumor xenografts due to severe respiratory motion artifact in the abdominal area. Orthotopic tumor models offer advantages over subcutaneous ones, because those can reflect the primary tumor microenvironment affecting blood supply, neovascularization, and tumor cell invasion. We have recently established a protocol of DCE-MRI of orthotopic pancreatic tumor xenografts in mouse models by securing tumors with an orthogonally bent plastic board to prevent motion transfer from the chest region during imaging. The pressure by this board was localized on the abdominal area, and has not resulted in respiratory difficulty of the animals. This article demonstrates the detailed procedure of orthotopic pancreatic tumor modeling using small animals and DCE-MRI of the tumor xenografts. Quantification method of pharmacokinetic parameters in DCE-MRI is also introduced. The procedure described in this article will assist investigators to apply DCE-MRI for orthotopic gastrointestinal cancer mouse models.

Introduction

O objetivo geral deste método é a aplicação de contraste dinâmico aprimorado ressonância magnética (DCE-MRI) para ortotópicos xenografts tumor pancreático em camundongos. DCE-MRI é um método não-invasivo de avaliação da microvasculatura num tecido alvo por monitorização da alteração de contraste MR ao longo de um certo período de tempo após a injecção. DCE-MRI tem sido utilizada para diagnóstico de tumores malignos e para avaliar a resposta do tumor a várias terapias 1-4. Quantitative DCE-MRI apresentou alta reprodutibilidade 5. Para quantificar os parâmetros farmacocinéticos de um agente de contraste MR em um tecido alvo, todas as imagens DCE-MR adquiridas em diferentes momentos e mapa T1 obtidos antes da injeção de contraste devem ser georeferenciados 6. No entanto, devido aos movimentos respiratórios e peristálticas na área abdominal, quantitativa DCE-MRI teve aplicação limitada para tumores gastrointestinais.

Modelos ortotópicos de tumor pancreático foram utilizados para avaliarresposta de pâncreas-tumor seguinte terapias biológicas e quimioterapias 7,8. Modelos ortotópicos de tumor são considerados superiores aos modelos subcutâneos convencionais, uma vez que o microambiente no local do tumor original é reflectida e, assim, a resposta do tumor à terapia humana podem ser previstos com mais precisão. No entanto, o pâncreas do mouse está localizado no quadrante superior esquerdo do abdome, de modo quantitativo DCE-MRI de ortotópicos xenotransplantes de tumor do pâncreas em ratos não foi prontamente implementadas.

Nós estabelecemos um protocolo de DCE-MRI de tumores abdominais em camundongos, fixando os tumores usando uma placa de plástico orthogonally dobrado para evitar a transferência de movimento da região do tórax 9. A pressão aplicada por este fórum foi localizada na área abdominal, e não resultou em dificuldade respiratória. Uma técnica automatizada imagem coregistration foi validado para DCE-MRI de órgãos abdominais em um modo livre de respiração, mas ele executa effectively apenas quando as regiões alvo mover-se lentamente e regularmente 10. A freqüência respiratória dos animais é variável durante o exame, moderação, de modo físico na área abdominal será necessário para recuperar os parâmetros farmacocinéticos de confiança em modelos de ratos tumor pancreático ortotópicos. Temos quantificada com sucesso os parâmetros farmacocinéticos de um agente de contraste MR em ortotópicos xenografts tumor pancreático usando a placa de plástico orthogonally dobrado em DCE-MRI 11-13. Aqui apresentamos o procedimento detalhado de modelagem tumor pancreático orthotopic, DCE-MRI dos xenotransplantes de tumor em ratos, e quantificação dos parâmetros farmacocinéticos.

Protocol

Todos os procedimentos foram aprovados pelo Comitê de Uso e Cuidado Animal Institucional da Universidade do Alabama, em Birmingham. 1. Orthotopic pâncreas Tumor Rato Modeling Linhas de padrão de cultura de células humanas do pâncreas-cancro em meio de Eagle modificado por Dulbecco (DMEM) suplementado com 10% de soro fetal bovino. Mantenha todas as culturas a 37 ° C em atmosfera humidificada com 5% de CO 2. Use 8-10 semanas de idade, do sexo feminino grav…

Representative Results

As células tumorais pancreáticas humanas crescer com sucesso em pâncreas de rato criando um tumor sólido. A Figura 1 apresenta fotografias de (A) um pâncreas normal onde a solução da célula de tumor é injectada, e (B) um ratinho representativo tendo um xenoenxerto de tumor pancreático ortotópico (MIA PaCa-2 ). Tumor está localizado no quadrante superior esquerdo do abdómen, ao lado do baço. Ele normalmente leva 2-4 semanas para que os tumores a crescer até 5-7 mm de diâmetro após o impl…

Discussion

Nós introduzimos os métodos detalhados de modelagem de tumor pancreático orthotopic usando ratos imunodeficientes, DCE-MRI de tumores abdominais em ratos, e quantificação de seus parâmetros cinéticos. Na modelagem de tumor pancreático orthotopic, é preciso ter cuidado ao inserir uma agulha na cauda do pâncreas. Se for bem sucedido, as células serão transferidos para a cabeça do pâncreas criando uma pequena bolha. Ao aplicar-se uma placa de plástico orthogonally dobrado, é fundamental para confirmar que o…

Declarações

The authors have nothing to disclose.

Acknowledgements

Authors thank Jeffrey Sellers to assist orthotopic pancreatic cancer mouse modeling. This work was supported by Research Initiative Pilot Awards from the Department of Radiology at UAB and NIH grants 2P30CA013148 and P50CA101955.

Materials

Name of Material/ Equipment Company Catalog Number Comments/Description
DMEM Invitrogen 11965-118
Fetal bovine serum Harlan Laboratories BT-9501
Betadine Purdue products 67618-153-01
5-0 Prolene sutures Ethicon 8720H
9.4T MR scanner Bruker Biospin Corporation BioSpec 94/20 USR
Gadoteridol Bracco Diagnostics Inc NDC 0270-1111-03
Micro-polyethelene tube Strategic Applications, Inc #PE-10-25
30G blunt tip needle Strategic Applications, Inc 89134-194
Monitoring and gating system SA instruments, Inc Model 1030 This is an MR compatiable system to measure resiratory rating and body temperature of small animals at the same time.
Syringe pump New Era Pump Systems, Inc. NE-1600

Referências

  1. Ergul, N., et al. Assessment of multifocality and axillary nodal involvement in early-stage breast cancer patients using 18F-FDG PET/CT compared to contrast-enhanced and diffusion-weighted magnetic resonance imaging and sentinel node biopsy. Acta Radiol. , (2014).
  2. Park, J. J., et al. Assessment of early response to concurrent chemoradiotherapy in cervical cancer: value of diffusion-weighted and dynamic contrast-enhanced MR imaging. Magn Reson Imaging. , (2014).
  3. Nguyen, H. T., et al. Prediction of chemotherapeutic response in bladder cancer using K-means clustering of dynamic contrast-enhanced (DCE)-MRI pharmacokinetic parameters. J Magn Reson Imaging. 10, (2014).
  4. Teo, Q. Q., Thng, C. H., Koh, T. S., Ng, Q. S. Dynamic Contrast-enhanced Magnetic Resonance Imaging: Applications in Oncology. Clin Oncol (R Coll Radiol). , (2014).
  5. Zhang, X., Pagel, M. D., Baker, A. F., Gillies, R. J. Reproducibility of magnetic resonance perfusion imaging. PLoS One. 9 (2), e89797 (2014).
  6. Kim, H., et al. Pancreatic adenocarcinoma: a pilot study of quantitative perfusion and diffusion-weighted breath-hold magnetic resonance imaging. Abdominal imaging. , (2014).
  7. Derosier, L. C., et al. Combination Treatment with TRA-8 Anti Death Receptor 5 Antibody and CPT-11 Induces Tumor Regression in an Orthotopic Model of Pancreatic Cancer. Clin Cancer Res. 13 (18), 5535s-5543s (2007).
  8. Derosier, L. C., et al. TRA-8 anti-DR5 monoclonal antibody and gemcitabine induce apoptosis and inhibit radiologically validated orthotopic pancreatic tumor growth. Mol Cancer Ther. 6 (12), 3198-3207 (2007).
  9. Kim, H., et al. Early therapy evaluation of combined anti-death receptor 5 antibody and gemcitabine in orthotopic pancreatic tumor xenografts by diffusion-weighted magnetic resonance imaging. Cancer Res. 68 (20), 8369-8376 (2008).
  10. Klein, S., Staring, M., Murphy, K., Viergever, M. A., Pluim, J. P. elastix: a toolbox for intensity-based medical image registration. IEEE Trans Med Imaging. 29 (1), 196-205 (2010).
  11. Kim, H., et al. Early therapy evaluation of combined cetuximab and irinotecan in orthotopic pancreatic tumor xenografts by dynamic contrast-enhanced magnetic resonance imaging. Mol Imaging. 10 (3), 153-167 (2011).
  12. Kim, H., et al. Antagonistic effects of anti-EMMPRIN antibody when combined with chemotherapy against hypovascular pancreatic cancers. M Mol Imaging Biol. 16 (1), 85-94 (2014).
  13. Kim, H., et al. Dual combination therapy targeting DR5 and EMMPRIN in pancreatic adenocarcinoma. Mol Cancer Ther. 11 (2), 405-415 (2012).
  14. Moyher, S. E., Vigneron, D. B., Nelson, S. J. Surface coil MR imaging of the human brain with an analytic reception profile correction. J Magn Reson Imaging. 5 (2), 139-144 (1995).
  15. Voigt, T., Nehrke, K., Doessel, O., Katscher, U. T1 corrected B1 mapping using multi-TR gradient echo sequences. Magn Reson Med. 64 (3), 725-733 (2010).
  16. Liu, H., Liu, Y., Zhao, Z., Zhang, L., Qiu, T. A new background distribution-based active contour model for three-dimensional lesion segmentation in breast DCE-MRI. Medical physics. 41 (8), 082303 (2014).
  17. Sarkar, S., Das, S. Multilevel image thresholding based on 2D histogram and maximum Tsallis entropy–a differential evolution approach. IEEE Trans Image Process. 22 (12), 4788-4797 (2013).
  18. Yankeelov, T. E., et al. Quantitative pharmacokinetic analysis of DCE-MRI data without an arterial input function: a reference region model. Magn Reson Imaging. 23 (4), 519-529 (2005).
  19. Cardenas-Rodriguez, J., Howison, C. M., Pagel, M. D. A linear algorithm of the reference region model for DCE-MRI is robust and relaxes requirements for temporal resolution. Magn Reson Imaging. 31 (4), 497-507 (2013).
  20. Tofts, P. S., et al. Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols. J Magn Reson Imaging. 10 (3), 223-232 (1999).
  21. Yankeelov, T. E., et al. Comparison of a reference region model with direct measurement of an AIF in the analysis of DCE-MRI data. Magn Reson Med. 57 (2), 353-361 (2007).
  22. Cao, R. Y., Amand, T., Ford, M. D., Piomelli, U., Funk, C. D. The Murine Angiotensin II-Induced Abdominal Aortic Aneurysm Model: Rupture Risk and Inflammatory Progression Patterns. Front Pharmacol. 1 (9), (2010).
  23. Parker, G. J., et al. Experimentally-derived functional form for a population-averaged high-temporal-resolution arterial input function for dynamic contrast-enhanced MRI. Magn Reson Med. 56 (5), 993-1000 (2006).
  24. Tseng, W., Leong, X., Engleman, E. Orthotopic mouse model of colorectal cancer. J Vis Exp. (10), 484 (2007).
  25. Bhullar, J. S., et al. A true orthotopic gastric cancer murine model using electrocoagulation. J Am Coll Surg. 217 (1), 64-70 (2013).
check_url/pt/52641?article_type=t

Play Video

Citar este artigo
Kim, H., Samuel, S., Totenhagen, J. W., Warren, M., Sellers, J. C., Buchsbaum, D. J. Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model. J. Vis. Exp. (98), e52641, doi:10.3791/52641 (2015).

View Video