Summary

Évaluation des résultats primaires dans un modèle porcin de infarctus aigu du myocarde

Published: October 14, 2016
doi:

Summary

l'évaluation des résultats fiables et précis est la clé pour la traduction des thérapies précliniques dans le traitement clinique. Le présent document décrit comment évaluer trois paramètres de résultats primaires cliniquement pertinents de la performance cardiaque et des lésions dans un modèle d'infarctus du myocarde aigu de porc.

Abstract

Mortality after acute myocardial infarction remains substantial and is associated with significant morbidity, like heart failure. Novel therapeutics are therefore required to confine cardiac damage, promote survival and reduce the disease burden of heart failure. Large animal experiments are an essential part in the translational process from experimental to clinical therapies. To optimize clinical translation, robust and representative outcome measures are mandatory. The present manuscript aims to address this need by describing the assessment of three clinically relevant outcome modalities in a pig acute myocardial infarction (AMI) model: infarct size in relation to area at risk (IS/AAR) staining, 3-dimensional transesophageal echocardiography (TEE) and admittance-based pressure-volume (PV) loops. Infarct size is the main determinant driving the transition from AMI to heart failure and can be quantified by IS/AAR staining. Echocardiography is a reliable and robust tool in the assessment of global and regional cardiac function in clinical cardiology. Here, a method for three-dimensional transesophageal echocardiography (3D-TEE) in pigs is provided. Extensive insight into cardiac performance can be obtained by admittance-based pressure-volume (PV) loops, including intrinsic parameters of myocardial function that are pre- and afterload independent. Combined with a clinically feasible experimental study protocol, these outcome measures provide researchers with essential information to determine whether novel therapeutic strategies could yield promising targets for future testing in clinical studies.

Introduction

L' insuffisance cardiaque avec une fraction d'éjection réduite (HFrEF) représente environ 50% de tous les cas d'insuffisance cardiaque, qui touche environ 1 – 2% des personnes dans le monde occidental 1. Sa cause la plus fréquente est l'infarctus du myocarde aigu (AMI). Comme la mortalité aiguë après un IAM a considérablement diminué en raison de la sensibilisation accrue et l'amélioration des options de traitement, l'accent a évolué vers ses séquelles chroniques; l'être le plus important HFrEF 2,3. Avec l' augmentation des coûts de soins de santé 4, l'épidémie croissante de l' insuffisance cardiaque souligne la nécessité de nouveaux diagnostics et thérapies qui peuvent être étudiés dans un modèle porcin hautement traductionnelle de remodelage indésirable après AMI comme décrit précédemment 5.

Les deux, les déterminants (par exemple, la taille de l' infarctus) et fonctionnelles des évaluations (par exemple, échocardiographie) du remodelage défavorable sont souvent utilisés pour les tests d'efficacité de nouveaux traitements, ce qui indique la nécessité de relméthodes iable et relativement peu coûteux. L'objectif du présent document est de répondre à ce besoin en introduisant des mesures de résultats importants et fiables pour les tests d'efficacité dans un modèle porcin de l'infarctus du myocarde aigu. Ceux-ci comprennent la taille de l'infarctus (IS) par rapport à la zone à risque (AAR), 3D échocardiographie transœsophagienne (3D-TEE) et pression-volume sur la base d'admission détaillé (PV) acquisition de la boucle.

La taille de l' infarctus est le principal déterminant de remodelage défavorable et de survie après AMI 6. Bien que la reperfusion en temps opportun de myocarde ischémique peut sauver cardiomyocytes réversiblement blessés et de limiter la taille de l' infarctus, la reperfusion elle – même provoque des dégâts supplémentaires par la génération de stress oxydatif et une réponse inflammatoire disproportionnée (ischémie-reperfusion (IRI)) 7. Par conséquent, IRI a été identifié comme une cible thérapeutique prometteuse. La capacité des nouveaux traitements pour réduire la taille de l'infarctus est quantifiée en évaluant la taille de l'infarctus par rapportà la zone à risque (AAR). AAR quantification est obligatoire pour corriger la variabilité inter-individuelle dans l'anatomie coronaire de modèles animaux, comme une plus grande AAR mène à une plus grande taille de l'infarctus absolu. Depuis la taille de l' infarctus est directement liée à la performance cardiaque et de la contractilité du myocarde, les variations de l' AAR peuvent influer sur l' étude des mesures de résultats , indépendamment des modalités de traitement 8.

échocardiographie transoesophagienne en trois dimensions (3D-TEE) est une méthode peu coûteuse sûre, fiable et, surtout, cliniquement applicable pour mesurer la fonction cardiaque non invasive. Considérant que échocardiographie transthoracique (TTE) images sont limitées à 2D à long et à court parasternale axe vues chez les porcs 9, 3D-TEE peut être utilisé pour obtenir des images complètes en 3 dimensions du ventricule gauche. Par conséquent, il ne nécessite pas des approximations mathématiques du ventricule gauche (LV) volumes tels que la règle de Simpson modifiée 10. Celui-ci est loin de correstimer ectement volumes LV après le remodelage du VG en raison de l'absence de géométrie cylindrique 11. De plus, 3D-TEE est préférable à l' échocardiographie épicardique car il ne nécessite pas d' interventions chirurgicales, qui ont été observés pour exercer des effets cardioprotecteurs dans le modèle actuel 12. Bien que l'utilisation de la 2D-TEE pour l'évaluation de la fonction myocardique a été décrite avant 13,14, les limitations concernant la géométrie du ventricule sont similaires à ceux observés en 2D-TTE et dépendent de l'étendue de remodelage du VG. Par conséquent, plus le Infarctus (et donc plus la probabilité d'une insuffisance cardiaque), les mesures 2D plus susceptibles deviennent viciée par des hypothèses géométriques erronées et plus le besoin de techniques 3D.

Néanmoins, la plupart des modalités d'imagerie sont limitées dans leur capacité à évaluer les propriétés fonctionnelles intrinsèques du myocarde. PV boucles fournir de telles informations supplémentaires pertinentes et leur acquisition est doncdécrit en détail ci-dessous.

Protocol

Toutes les expériences sur les animaux ont été approuvés par le Comité d'éthique sur l'expérimentation animale de l'Université Medical Center Utrecht (Utrecht, Pays-Bas) et sont conformes à la «Guide pour les soins et l'utilisation des animaux de laboratoire». NOTE: Le protocole pour effectuer un ballon d' occlusion fermée thoracique ne fait pas partie du manuscrit en cours et est décrit en détail ailleurs 5. En bref, les porcs (60 – 70 kg) sont s…

Representative Results

3D échocardiographie transœsophagienne 3D échocardiographie transoesophagienne (3D-TEE) peut être utilisé pour l'évaluation de la fonction cardiaque globale. Après AMI, la fonction cardiaque globale diffère de valeurs de référence en bonne santé. En particulier, la fraction d'éjection du ventricule gauche (FEVG) diminue de 59 ± 4% à 37 ± 6% après une semaine de reperfusion (n = 10…

Discussion

Remodelage cardiaque est en grande partie en fonction de la taille de l' infarctus du myocarde et de la qualité de l' infarctus du myocarde réparer 6,26. Pour évaluer l'ancien d'une manière standardisée, le présent manuscrit fournit une méthode élégante de perfusion in vivo de bleu Evans combiné avec ex vivo TTC coloration, qui a été validé et largement utilisé 8,16,27,28. Cette méthode permet la quantification de la zone à risque (AAR) et la taille…

Declarações

The authors have nothing to disclose.

Acknowledgements

The authors gratefully acknowledge Marlijn Jansen, Joyce Visser, Grace Croft, Martijn van Nieuwburg, Danny Elbersen and Evelyn Velema for their excellent technical support during the animal experiments.

Materials

3-dimensional transesophageal echocardiography
iE33 ultrasound device Philips
X7-2t transducer Philips
Aquasonic® 100 ultrasound transmission gel Parker Laboratories Inc. 01-34 Alternative product can be used
Battery handle type C (laryngoscope handle) Riester 12303
Ri-Standard Miller blade MIL 4 (laryngoscope blade) Riester 12225
Qlab 10.0 (3DQ Advanced) analysis software Philips
Name Company Catalog Number Comments
Pressure-volume loop acquisition
Cardiac defibrillator Philips
0.9% saline Braun
8F Percutaneous Sheath Introducer Set Arrow CP-08803 Alternative product can be used
9F Radifocus® Introducer II Standard Kit  Terumo RS*A90K10SQ Alternative product can be used
8F Fogarty catheter Edward Life Sciences 62080814F Alternative product can be used
7F Criticath™ SP5107H TD catheter (Swan-Ganz) Becton Dickinson (BD) 680078 Alternative product can be used
Ultraview SL Patient Monitor and Invasive Command Module (external cardiac output device) Spacelabs Healthcare 91387 Alternative product can be used
ADVantage system™ Transonic SciSense
7F tetra-polar admittance catheter (7.0 VSL Pigtail / no lumen) Transonic SciSense
Multi-channel acquisition system (Iworx 404) Iworx
Labscribe V2.0 analysis software Iworx Alternative product can be used
Name Company Catalog Number Comments
Infarct size / area-at-risk quantification
Diathermy Alternative product can be used
Lebsch knife Alternative product can be used
Hammer Alternative product can be used
Bone marrow wax Syneture Alternative product can be used
Klinkenberg scissors Alternative product can be used
Retractor Alternative product can be used
Surgical scissors
7F Percutaneous Sheath Introducer Set  Arrow CP-08703 Alternative product can be used
8F Percutaneous Sheath Introducer Set  Arrow CP-08803 Alternative product can be used
7F JL4 guiding catheter  Boston Scientific H749 34357-662 Alternative product can be used
8F JL4 guiding catheter  Boston Scientific H749 34358-662  Alternative product can be used
COPILOT Bleedback Control Valves  Abbott Vascular 1003331 Alternative product can be used
BD Connecta™  Franklin Lakes 394995 Alternative product can be used
Contrast agent Telebrix
Persuader 9 Steerable Guidewire 9 (0.014", 180 cm, straight tip), hydrophilic coating Medtronic Inc. 9PSDR180HS Alternative product can be used
SAPPHIRE™ Coronary Dilatation Catheter (PTCA balloon suitable for the size of the particular coronary artery (2.75 – 3.25 mm)) OrbusNeich 103-3015 Alternative product can be used
Evans Blue  Sigma-Aldrich E2129-100G Toxic. Alternative product can be used
2,3,5-triphenyl-tetrazolium chloride (TTC) Sigma-Aldrich T8877-100G Irritant. Alternative product can be used
9V battery
Ruler
Photocamera Sony
ImageJ National Institutes of Health Alternative product can be used

Referências

  1. Mosterd, A., Hoes, A. W. Clinical epidemiology of heart failure. Heart. 93 (9), 1137-1146 (2007).
  2. Nichols, M., et al. . European Cardiovascular Disease Statistics. , (2012).
  3. Krumholz, H. M., et al. Reduction in Acute Myocardial Infarction Mortality in the United States. JAMA. 302 (7), 767-773 (2010).
  4. Go, A. S., et al. Heart disease and stroke statistics – 2013 update: A Report from the American Heart Association. Circulation. 127 (1), (2013).
  5. Koudstaal, S., et al. Myocardial infarction and functional outcome assessment in pigs. J. Vis. Exp. (86), e51269 (2014).
  6. Chareonthaitawee, P., Christian, T. F., Hirose, K., Gibbons, R. J., Rumberger, J. A. Relation of initial infarct size to extent of left ventricular remodeling in the year after acute myocardial infarction. J. Am. Coll. Cardiol. 25 (3), 567-573 (1995).
  7. Yellon, D. M., Hausenloy, D. J. Myocardial reperfusion injury. N. Engl. J. Med. 357 (11), 1221-1235 (2007).
  8. Suzuki, Y., Lyons, J. K., Yeung, A. C., Ikeno, F. In vivo porcine model of reperfused myocardial infarction: In situ double staining to measure precise infarct area/area at risk. Catheter Cardiovasc. Interv. 71 (1), 100-107 (2008).
  9. Weidemann, F., et al. Myocardial function defined by strain rate and strain during alterations in inotropic states and heart rate. Am. J. Physiol. Heart Circ. Physiol. 283 (2), H792-H799 (2002).
  10. Mercier, J. C., et al. Two-dimensional echocardiographic assessment of left ventricular volumes and ejection fraction in children. Circulation. 65 (5), 962-969 (1982).
  11. De Jong, R., et al. Cardiac Function in a Long-Term Follow-Up Study of Moderate and Severe Porcine Model of Chronic Myocardial Infarction. Biomed. Res. Int. 2015, 1-11 (2015).
  12. Van Hout, G. P. J., et al. Invasive surgery reduces infarct size and preserves cardiac function in a porcine model of myocardial infarction. J. Cell. Mol. Med. , 2655-2663 (2015).
  13. Meybohm, P., et al. Assessment of left ventricular systolic function during acute myocardial ischemia: A comparison of transpulmonary thermodilution and transesophageal echocardiography. Minerva Anestesiol. 77 (2), 132-141 (2011).
  14. Gruenewald, M., et al. Visual evaluation of left ventricular performance predicts volume responsiveness early after resuscitation from cardiac arrest. Resuscitation. 82 (12), 1553-1557 (2011).
  15. Bolli, R., Becker, L., Gross, G., Mentzer, R., Balshaw, D., Lathrop, D. A. Myocardial protection at a crossroads: The need for translation into clinical therapy. Circ. Res. 95 (2), 125-134 (2004).
  16. Timmers, L., et al. Exenatide reduces infarct size and improves cardiac function in a porcine model of ischemia and reperfusion injury. J. Am. Coll. Cardiol. 53 (6), 501-510 (2009).
  17. Csonka, C., et al. Measurement of myocardial infarct size in preclinical studies. J. Pharmacol. Toxicol. Methods. 61 (2), 163-170 (2010).
  18. Law, R., Katzka, D. A., Baron, T. H. Zenker’s Diverticulum. Clin. Gastroenterol. Hepatol. 12 (11), 1773-1782 (2014).
  19. Philips Healthcare. . QLAB 10.0 Quick Card: 3DQ and 3DQ Adv measurements guide. , (2013).
  20. Transonic. . ADV500 Pressure-Volume Measurement System Use and Care Manual, version 5. , (2006).
  21. Schramm, W. Is the cardiac output obtained from a Swan-Ganz catheter always zero?. J. Clin. Monit. Comput. 22 (6), 431-433 (2008).
  22. iWorx. . LabScribe 3: Software Manual for Pressure-Volume Analyses. , (2014).
  23. Hueper, W. C., Ichniowski, C. T. Toxicopathologic studies on the dye T-1824. Arch. Surg. 48 (1), 17-26 (1944).
  24. Van Hout, G. P. J., et al. Admittance-based pressure-volume loops versus gold standard cardiac magnetic resonance imaging in a porcine model of myocardial infarction. Physiol. Rep. 2 (4), 1-9 (2014).
  25. Burkhoff, D., Mirsky, I., Suga, H. Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guide for clinical, translational, and basic researchers. Am. J. Physiol. Heart Circ. Physiol. Heart Circ. Physiol. 289 (2), H501-H512 (2005).
  26. Frangogiannis, N. G. The inflammatory response in myocardial injury, repair, and remodelling. Nat. Rev. Cardiol. 11 (5), 255-265 (2014).
  27. Fishbein, M., et al. Early phase acute myocardial infarct size quantification: validation of the triphenyl tetrazolium chloride tissue enzyme staining technique. Am. Heart. J. 101 (5), 593-600 (1981).
  28. Arslan, F., et al. Treatment with OPN-305, a humanized anti-toll-like receptor-2 antibody, reduces myocardial ischemia/reperfusion injury in pigs. Circ. Cardiovasc. Interv. 5 (2), 279-287 (2012).
  29. Meyns, B., Stolinski, J., Leunens, V., Verbeken, E., Flameng, W. Left ventricular support by Catheter-Mountedaxial flow pump reduces infarct size. J. Am. Coll. Cardiol. 41 (7), 1087-1095 (2003).
  30. Khalil, P. N., et al. Histochemical assessment of early myocardial infarction using 2,3,5-triphenyltetrazolium chloride in blood-perfused porcine hearts. J. Pharmacol. Toxicol. Methods. 54 (3), 307-312 (2006).
  31. Gardner, B. I., Bingham, S. E., Allen, M. R., Blatter, D. D., Anderson, J. L. Cardiac magnetic resonance versus transthoracic echocardiography for the assessment of cardiac volumes and regional function after myocardial infarction: an intrasubject comparison using simultaneous intrasubject recordings. Cardiovasc. Ultrasound. 7, 38 (2009).
  32. Santos-Gallego, C., et al. 3D-Echocardiography Demonstrates Excellent Correlation With Cardiac Magnetic Resonance for Assessment of Left Ventricular Function and Volumes in a Model of Myocardial Infarction. J. Am. Coll. Cardiol. 59 (13), E1564 (2012).
  33. Keith Jones, ., W, , et al. Peripheral nociception associated with surgical incision elicits remote nonischemic cardioprotection via neurogenic activation of protein kinase C signaling. Circulation. 120, S1-S9 (2009).
  34. Gross, G. J., Baker, J. E., Moore, J., Falck, J. R., Nithipatikom, K. Abdominal Surgical Incision Induces Remote Preconditioning of Trauma (RPCT) via Activation of Bradykinin Receptors (BK2R) and the Cytochrome P450 Epoxygenase Pathway in Canine Hearts. Cardiovasc. Drugs Ther. 25 (6), 517-522 (2011).
  35. Van Hout, G. P. J., de Jong, R., Vrijenhoek, J. E. P., Timmers, L., Duckers, H. J., Hoefer, I. E. Admittance-based pressure-volume loop measurements in a porcine model of chronic myocardial infarction. Exp. Physiol. 98 (11), 1565-1575 (2013).
  36. Sunagawa, K., Maughan, W. L., Burkhoff, D., Sagawa, K. Left ventricular interaction with arterial load studied in isolated canine ventricle. Am. J. Physiol. 245 (5 Pt 1), H773-H780 (1983).
  37. Steendijk, P., Baan, J., Der Velde, E. T. V. a. n., Baan, J. Effects of critical coronary stenosis on global systolic left ventricular function quantified by pressure-volume relations during dobutamine stress in the canine heart. J. Am. Coll. Cardiol. 32 (3), 816-826 (1998).
check_url/pt/54021?article_type=t

Play Video

Citar este artigo
Ellenbroek, G. H., van Hout, G. P., Timmers, L., Doevendans, P. A., Pasterkamp, G., Hoefer, I. E. Primary Outcome Assessment in a Pig Model of Acute Myocardial Infarction. J. Vis. Exp. (116), e54021, doi:10.3791/54021 (2016).

View Video