Summary

Primær Outcome Vurdering i en gris modell av akutt hjerteinfarkt

Published: October 14, 2016
doi:

Summary

Pålitelig og nøyaktig utfallet vurdering er nøkkelen for oversettelse av prekliniske terapi i klinisk behandling. Den gjeldende dokumentet beskriver hvordan du vurdere tre klinisk relevante primære resultatparametre av hjertefunksjon og skade i en gris akutt hjerteinfarkt modell.

Abstract

Mortality after acute myocardial infarction remains substantial and is associated with significant morbidity, like heart failure. Novel therapeutics are therefore required to confine cardiac damage, promote survival and reduce the disease burden of heart failure. Large animal experiments are an essential part in the translational process from experimental to clinical therapies. To optimize clinical translation, robust and representative outcome measures are mandatory. The present manuscript aims to address this need by describing the assessment of three clinically relevant outcome modalities in a pig acute myocardial infarction (AMI) model: infarct size in relation to area at risk (IS/AAR) staining, 3-dimensional transesophageal echocardiography (TEE) and admittance-based pressure-volume (PV) loops. Infarct size is the main determinant driving the transition from AMI to heart failure and can be quantified by IS/AAR staining. Echocardiography is a reliable and robust tool in the assessment of global and regional cardiac function in clinical cardiology. Here, a method for three-dimensional transesophageal echocardiography (3D-TEE) in pigs is provided. Extensive insight into cardiac performance can be obtained by admittance-based pressure-volume (PV) loops, including intrinsic parameters of myocardial function that are pre- and afterload independent. Combined with a clinically feasible experimental study protocol, these outcome measures provide researchers with essential information to determine whether novel therapeutic strategies could yield promising targets for future testing in clinical studies.

Introduction

Hjertesvikt med redusert ejeksjonsfraksjon (HFrEF) står for ca 50% av alle hjertesvikt tilfeller påvirker anslagsvis 1-2% av mennesker i den vestlige verden en. Den mest utbredte årsaken er akutt hjerteinfarkt (AMI). Som akutt dødelighet etter akutt hjerteinfarkt har falt betydelig på grunn av økt bevissthet og bedre behandlingstilbud, har fokus flyttet mot sin kroniske følgetilstander; den mest fremtredende vesen HFrEF 2,3. Sammen med økende helsekostnader 4, den økende epidemi av hjertesvikt understreker behovet for romanen diagnostikk og terapi, som kan studeres i et svært translasjonell svin modell av uønskede ombygging etter AMI som tidligere beskrevet fem.

Begge, determinanter (f.eks infarktstørrelse) og funksjonelle vurderinger (f.eks ekkokardiografi) av uønskede ombygging blir ofte brukt for effektiv testing av nye terapeutiske midler, noe som indikerer behovet for reliable og forholdsvis rimelige metoder. Formålet med den gjeldende papir er å dekke dette behovet ved å innføre viktige og pålitelige effektmål for effektiv testing i en gris modell av akutt hjerteinfarkt. Disse inkluderer infarktstørrelse (IS) i forhold til området i fare (AAR), 3D transesophageal ekkokardiografi (3D-TEE) og detaljert adgang baserte trykk volum (PV) sløyfe oppkjøpet.

Infarktstørrelse er den viktigste determinant av uønskede ombygging og overlevelse etter AMI 6. Selv om rettidig reperfusjon av iskemisk hjertemuskelen kan berge reversibelt skadde cardiomyocytes og begrense infarktstørrelse, reperfusjon seg selv forårsaker ytterligere skade ved generering av oksidativt stress og et uforholdsmessig betennelsesreaksjon (iskemi-reperfusjon skade (IRI)) 7. Derfor IRI er blitt identifisert som et lovende terapeutisk mål. Evnen av nye terapeutiske midler for å redusere infarktstørrelse er kvantifisert ved å bestemme infarktstørrelsen i relasjontil området i fare (AAR). AAR kvantifisering er obligatorisk å korrigere for inter-individuell variasjon i koronaranatomien dyremodeller, som en større AAR fører til en større absolutt infarktstørrelsen. Siden infarktstørrelsen er direkte relatert til hjerteytelse og myokardial kontraktilitet, kan variasjoner i AAR påvirke studere effektmål uavhengig av behandlingsmetoder 8.

Tredimensjonal transesophageal ekkokardiografi (3D-TEE) er en trygg, pålitelig og viktigst, klinisk relevant billig metode for å måle hjertefunksjonen ikke-invasiv. Mens transtorakal ekkokardiografi (TTE) bilder er begrenset til 2D parasternal lange og korte aksen utsikt i griser 9, kan 3D-TEE brukes for å oppnå fullstendig tre-dimensjonale bilder av venstre ventrikkel. Derfor krever det ikke matematiske tilnærmelser av venstre ventrikkel (LV) volumer som den modifiserte Simpsons regel 10. Sistnevnte faller kort av korrectly estimering LV volumer etter LV remodeling på grunn av mangel av den sylindriske geometri 11. Videre er 3D-TEE å foretrekke fremfor epikardiell ekkokardiografi som det ikke krever kirurgisk inngrep, som har blitt observert å utøve kardioprotektive virkninger i den foreliggende modellen 12. Selv om bruken av 2D-TEE for vurdering av myokardfunksjon har blitt beskrevet før 13,14, begrensninger vedrørende ventrikkel geometrien er lik de observerte i 2D-TTE og avhenger av omfanget av LV ombygging. Derfor, jo større infarkt (og dermed høyere er sannsynligheten for hjertesvikt), jo mer sannsynlig 2D-målinger blir feil ved uriktige geometriske forutsetninger og jo høyere behovet for 3D-teknikker.

Ikke desto mindre er de fleste avbildningsmodaliteter begrenset i sin evne til å vurdere iboende funksjonelle egenskapene til hjertemuskelen. PV loops gi slike relevant tilleggsinformasjon og anskaffelses er derforbeskrevet i detalj nedenfor.

Protocol

Alle dyreforsøk ble godkjent av etisk komité for forsøk med dyr ved University Medical Center Utrecht (Utrecht, Nederland) og i samsvar med 'Guide for omsorg og bruk av forsøksdyr ". MERK: Protokollen for å utføre en lukket bryst ballong okklusjon er ikke en del av den aktuelle manuskript og er beskrevet i detalj et annet sted 5. Kort sagt, griser – er (60 70 kg) utsatt for 75 min transluminal ballong okklusjon av midtdelen av venstre fremre nedstigende arterie (LAD…

Representative Results

3D transesophageal Ekkokardiografi 3D transesophageal ekkokardiografi (3D-TEE) kan brukes for vurdering av globale hjertefunksjon. Etter AMI, global hjertefunksjon er forskjellig fra friske utgangsverdier. Spesielt venstre ventrikkel ejeksjonsfraksjon (LVEF) reduseres fra 59 ± 4% til 37 ± 6% etter en uke med reperfusjon (n = 10) (GPJ van Hout, 2015). En økning i slutt-systoliske volum (51 ± 7 til 82 …

Discussion

Cardiac ombygging er i stor grad avhengig av hjerteinfarkt størrelsen og kvaliteten på hjerteinfarkt reparere 6,26. For å vurdere den tidligere på en standardisert måte, tilveiebringer foreliggende manuskriptet en elegant metode for in vivo tilførsel av Evans blått i kombinasjon med ex vivo TTC flekker, som har blitt validert og i stor utstrekning benyttet 8,16,27,28. Denne metoden gjør det mulig for kvantifisering av arealet i fare (AAR) og infarktstørrelsen i forhold ti…

Declarações

The authors have nothing to disclose.

Acknowledgements

The authors gratefully acknowledge Marlijn Jansen, Joyce Visser, Grace Croft, Martijn van Nieuwburg, Danny Elbersen and Evelyn Velema for their excellent technical support during the animal experiments.

Materials

3-dimensional transesophageal echocardiography
iE33 ultrasound device Philips
X7-2t transducer Philips
Aquasonic® 100 ultrasound transmission gel Parker Laboratories Inc. 01-34 Alternative product can be used
Battery handle type C (laryngoscope handle) Riester 12303
Ri-Standard Miller blade MIL 4 (laryngoscope blade) Riester 12225
Qlab 10.0 (3DQ Advanced) analysis software Philips
Name Company Catalog Number Comments
Pressure-volume loop acquisition
Cardiac defibrillator Philips
0.9% saline Braun
8F Percutaneous Sheath Introducer Set Arrow CP-08803 Alternative product can be used
9F Radifocus® Introducer II Standard Kit  Terumo RS*A90K10SQ Alternative product can be used
8F Fogarty catheter Edward Life Sciences 62080814F Alternative product can be used
7F Criticath™ SP5107H TD catheter (Swan-Ganz) Becton Dickinson (BD) 680078 Alternative product can be used
Ultraview SL Patient Monitor and Invasive Command Module (external cardiac output device) Spacelabs Healthcare 91387 Alternative product can be used
ADVantage system™ Transonic SciSense
7F tetra-polar admittance catheter (7.0 VSL Pigtail / no lumen) Transonic SciSense
Multi-channel acquisition system (Iworx 404) Iworx
Labscribe V2.0 analysis software Iworx Alternative product can be used
Name Company Catalog Number Comments
Infarct size / area-at-risk quantification
Diathermy Alternative product can be used
Lebsch knife Alternative product can be used
Hammer Alternative product can be used
Bone marrow wax Syneture Alternative product can be used
Klinkenberg scissors Alternative product can be used
Retractor Alternative product can be used
Surgical scissors
7F Percutaneous Sheath Introducer Set  Arrow CP-08703 Alternative product can be used
8F Percutaneous Sheath Introducer Set  Arrow CP-08803 Alternative product can be used
7F JL4 guiding catheter  Boston Scientific H749 34357-662 Alternative product can be used
8F JL4 guiding catheter  Boston Scientific H749 34358-662  Alternative product can be used
COPILOT Bleedback Control Valves  Abbott Vascular 1003331 Alternative product can be used
BD Connecta™  Franklin Lakes 394995 Alternative product can be used
Contrast agent Telebrix
Persuader 9 Steerable Guidewire 9 (0.014", 180 cm, straight tip), hydrophilic coating Medtronic Inc. 9PSDR180HS Alternative product can be used
SAPPHIRE™ Coronary Dilatation Catheter (PTCA balloon suitable for the size of the particular coronary artery (2.75 – 3.25 mm)) OrbusNeich 103-3015 Alternative product can be used
Evans Blue  Sigma-Aldrich E2129-100G Toxic. Alternative product can be used
2,3,5-triphenyl-tetrazolium chloride (TTC) Sigma-Aldrich T8877-100G Irritant. Alternative product can be used
9V battery
Ruler
Photocamera Sony
ImageJ National Institutes of Health Alternative product can be used

Referências

  1. Mosterd, A., Hoes, A. W. Clinical epidemiology of heart failure. Heart. 93 (9), 1137-1146 (2007).
  2. Nichols, M., et al. . European Cardiovascular Disease Statistics. , (2012).
  3. Krumholz, H. M., et al. Reduction in Acute Myocardial Infarction Mortality in the United States. JAMA. 302 (7), 767-773 (2010).
  4. Go, A. S., et al. Heart disease and stroke statistics – 2013 update: A Report from the American Heart Association. Circulation. 127 (1), (2013).
  5. Koudstaal, S., et al. Myocardial infarction and functional outcome assessment in pigs. J. Vis. Exp. (86), e51269 (2014).
  6. Chareonthaitawee, P., Christian, T. F., Hirose, K., Gibbons, R. J., Rumberger, J. A. Relation of initial infarct size to extent of left ventricular remodeling in the year after acute myocardial infarction. J. Am. Coll. Cardiol. 25 (3), 567-573 (1995).
  7. Yellon, D. M., Hausenloy, D. J. Myocardial reperfusion injury. N. Engl. J. Med. 357 (11), 1221-1235 (2007).
  8. Suzuki, Y., Lyons, J. K., Yeung, A. C., Ikeno, F. In vivo porcine model of reperfused myocardial infarction: In situ double staining to measure precise infarct area/area at risk. Catheter Cardiovasc. Interv. 71 (1), 100-107 (2008).
  9. Weidemann, F., et al. Myocardial function defined by strain rate and strain during alterations in inotropic states and heart rate. Am. J. Physiol. Heart Circ. Physiol. 283 (2), H792-H799 (2002).
  10. Mercier, J. C., et al. Two-dimensional echocardiographic assessment of left ventricular volumes and ejection fraction in children. Circulation. 65 (5), 962-969 (1982).
  11. De Jong, R., et al. Cardiac Function in a Long-Term Follow-Up Study of Moderate and Severe Porcine Model of Chronic Myocardial Infarction. Biomed. Res. Int. 2015, 1-11 (2015).
  12. Van Hout, G. P. J., et al. Invasive surgery reduces infarct size and preserves cardiac function in a porcine model of myocardial infarction. J. Cell. Mol. Med. , 2655-2663 (2015).
  13. Meybohm, P., et al. Assessment of left ventricular systolic function during acute myocardial ischemia: A comparison of transpulmonary thermodilution and transesophageal echocardiography. Minerva Anestesiol. 77 (2), 132-141 (2011).
  14. Gruenewald, M., et al. Visual evaluation of left ventricular performance predicts volume responsiveness early after resuscitation from cardiac arrest. Resuscitation. 82 (12), 1553-1557 (2011).
  15. Bolli, R., Becker, L., Gross, G., Mentzer, R., Balshaw, D., Lathrop, D. A. Myocardial protection at a crossroads: The need for translation into clinical therapy. Circ. Res. 95 (2), 125-134 (2004).
  16. Timmers, L., et al. Exenatide reduces infarct size and improves cardiac function in a porcine model of ischemia and reperfusion injury. J. Am. Coll. Cardiol. 53 (6), 501-510 (2009).
  17. Csonka, C., et al. Measurement of myocardial infarct size in preclinical studies. J. Pharmacol. Toxicol. Methods. 61 (2), 163-170 (2010).
  18. Law, R., Katzka, D. A., Baron, T. H. Zenker’s Diverticulum. Clin. Gastroenterol. Hepatol. 12 (11), 1773-1782 (2014).
  19. Philips Healthcare. . QLAB 10.0 Quick Card: 3DQ and 3DQ Adv measurements guide. , (2013).
  20. Transonic. . ADV500 Pressure-Volume Measurement System Use and Care Manual, version 5. , (2006).
  21. Schramm, W. Is the cardiac output obtained from a Swan-Ganz catheter always zero?. J. Clin. Monit. Comput. 22 (6), 431-433 (2008).
  22. iWorx. . LabScribe 3: Software Manual for Pressure-Volume Analyses. , (2014).
  23. Hueper, W. C., Ichniowski, C. T. Toxicopathologic studies on the dye T-1824. Arch. Surg. 48 (1), 17-26 (1944).
  24. Van Hout, G. P. J., et al. Admittance-based pressure-volume loops versus gold standard cardiac magnetic resonance imaging in a porcine model of myocardial infarction. Physiol. Rep. 2 (4), 1-9 (2014).
  25. Burkhoff, D., Mirsky, I., Suga, H. Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guide for clinical, translational, and basic researchers. Am. J. Physiol. Heart Circ. Physiol. Heart Circ. Physiol. 289 (2), H501-H512 (2005).
  26. Frangogiannis, N. G. The inflammatory response in myocardial injury, repair, and remodelling. Nat. Rev. Cardiol. 11 (5), 255-265 (2014).
  27. Fishbein, M., et al. Early phase acute myocardial infarct size quantification: validation of the triphenyl tetrazolium chloride tissue enzyme staining technique. Am. Heart. J. 101 (5), 593-600 (1981).
  28. Arslan, F., et al. Treatment with OPN-305, a humanized anti-toll-like receptor-2 antibody, reduces myocardial ischemia/reperfusion injury in pigs. Circ. Cardiovasc. Interv. 5 (2), 279-287 (2012).
  29. Meyns, B., Stolinski, J., Leunens, V., Verbeken, E., Flameng, W. Left ventricular support by Catheter-Mountedaxial flow pump reduces infarct size. J. Am. Coll. Cardiol. 41 (7), 1087-1095 (2003).
  30. Khalil, P. N., et al. Histochemical assessment of early myocardial infarction using 2,3,5-triphenyltetrazolium chloride in blood-perfused porcine hearts. J. Pharmacol. Toxicol. Methods. 54 (3), 307-312 (2006).
  31. Gardner, B. I., Bingham, S. E., Allen, M. R., Blatter, D. D., Anderson, J. L. Cardiac magnetic resonance versus transthoracic echocardiography for the assessment of cardiac volumes and regional function after myocardial infarction: an intrasubject comparison using simultaneous intrasubject recordings. Cardiovasc. Ultrasound. 7, 38 (2009).
  32. Santos-Gallego, C., et al. 3D-Echocardiography Demonstrates Excellent Correlation With Cardiac Magnetic Resonance for Assessment of Left Ventricular Function and Volumes in a Model of Myocardial Infarction. J. Am. Coll. Cardiol. 59 (13), E1564 (2012).
  33. Keith Jones, ., W, , et al. Peripheral nociception associated with surgical incision elicits remote nonischemic cardioprotection via neurogenic activation of protein kinase C signaling. Circulation. 120, S1-S9 (2009).
  34. Gross, G. J., Baker, J. E., Moore, J., Falck, J. R., Nithipatikom, K. Abdominal Surgical Incision Induces Remote Preconditioning of Trauma (RPCT) via Activation of Bradykinin Receptors (BK2R) and the Cytochrome P450 Epoxygenase Pathway in Canine Hearts. Cardiovasc. Drugs Ther. 25 (6), 517-522 (2011).
  35. Van Hout, G. P. J., de Jong, R., Vrijenhoek, J. E. P., Timmers, L., Duckers, H. J., Hoefer, I. E. Admittance-based pressure-volume loop measurements in a porcine model of chronic myocardial infarction. Exp. Physiol. 98 (11), 1565-1575 (2013).
  36. Sunagawa, K., Maughan, W. L., Burkhoff, D., Sagawa, K. Left ventricular interaction with arterial load studied in isolated canine ventricle. Am. J. Physiol. 245 (5 Pt 1), H773-H780 (1983).
  37. Steendijk, P., Baan, J., Der Velde, E. T. V. a. n., Baan, J. Effects of critical coronary stenosis on global systolic left ventricular function quantified by pressure-volume relations during dobutamine stress in the canine heart. J. Am. Coll. Cardiol. 32 (3), 816-826 (1998).
check_url/pt/54021?article_type=t

Play Video

Citar este artigo
Ellenbroek, G. H., van Hout, G. P., Timmers, L., Doevendans, P. A., Pasterkamp, G., Hoefer, I. E. Primary Outcome Assessment in a Pig Model of Acute Myocardial Infarction. J. Vis. Exp. (116), e54021, doi:10.3791/54021 (2016).

View Video