Summary

تماما الجهاز الآلي الطرد المركزي ميكروفلويديك للكشف عن البروتين فائق الحساسية من الدم الكامل

Published: April 16, 2016
doi:

Summary

This protocol demonstrates how to achieve femto molar detection sensitivity of proteins in 10 µL of whole blood within 30 min. This can be achieved by using electrospun nanofibrous mats integrated in a lab-on-a-disc, which offers high surface area as well as effective mixing and washing for enhanced signal-to-noise ratio.

Abstract

Enzyme-linked immunosorbent assay (ELISA) is a promising method to detect small amount of proteins in biological samples. The devices providing a platform for reduced sample volume and assay time as well as full automation are required for potential use in point-of-care-diagnostics. Recently, we have demonstrated ultrasensitive detection of serum proteins, C-reactive protein (CRP) and cardiac troponin I (cTnI), utilizing a lab-on-a-disc composed of TiO2 nanofibrous (NF) mats. It showed a large dynamic range with femto molar (fM) detection sensitivity, from a small volume of whole blood in 30 min. The device consists of several components for blood separation, metering, mixing, and washing that are automated for improved sensitivity from low sample volumes. Here, in the video demonstration, we show the experimental protocols and know-how for the fabrication of NFs as well as the disc, their integration and the operation in the following order: processes for preparing TiO2 NF mat; transfer-printing of TiO2 NF mat onto the disc; surface modification for immune-reactions, disc assembly and operation; on-disc detection and representative results for immunoassay. Use of this device enables multiplexed analysis with minimal consumption of samples and reagents. Given the advantages, the device should find use in a wide variety of applications, and prove beneficial in facilitating the analysis of low abundant proteins.

Introduction

وقد وضعت عدة برامج لتشخيص المرض استنادا إلى المواد النانومترية الحجم 1،2 مثل أسلاك، 3 النانوية، 4 الأنابيب النانوية و 5 و ألياف النانو (NFS) 6-8. هذه المواد النانوية آفاقا ممتازة في تصميم التقنيات الجديدة لاختبارات بيولوجية حساسة للغاية نظرا لخصائص الفيزيائية الفريدة. على سبيل المثال، تم استخدام ألياف النانو أكسيد الزنك mesoporous للفيمتو-الرحى كشف حساسة من المؤشرات الحيوية سرطان الثدي. 9 في الآونة الأخيرة، المواد متناهية الصغر على أساس ثاني أكسيد التيتانيوم (تيو 2) تم التنقيب فيها عن تطبيقات bioanalytical 10 النظر في الاستقرار الكيميائي، 11 يذكر تمسخ البروتين و 12 و توافق مع الحياة. 13 وبالإضافة إلى ذلك، فإن مجموعة الهيدروكسيل على سطح تيو 2 تسهل تعديل الكيميائية ومرفق التساهمية الجزيئات الحيوية. 14،15 منقوشة تيو 2 ثين الأفلام 16 أو تيو 2 نانوتيوب 17 استخدمت لتعزيز حساسية الكشف عن البروتين المستهدف من خلال زيادة مساحة السطح. ومع ذلك، فإن عملية تصنيع معقدة نوعا ما، وتتطلب معدات باهظة الثمن. من ناحية أخرى، NFS electrospun تحظى باهتمام بسبب مساحة عالية وكذلك عملية مباشرة وتلفيق تكلفة منخفضة؛ 18،19 بعد، فإن السمة الهشة أو فضفاضة من electrospun تيو 2 NF حصيرة يجعل من الصعب التعامل معها و تتكامل مع أجهزة ميكروفلويديك. 6،20 لذلك، نادرا ما تستخدم في تيو 2 NF الحصير في تطبيقات bioanalytical، ولا سيما تلك التي تتطلب الظروف القاسية الغسيل.

في هذه الدراسة، للتغلب على هذه القيود، قمنا بتطوير تقنية جديدة لنقل electrospun NF الحصير على سطح أي الركيزة الهدف من خلال الاستفادة من طبقة لاصقة ثنائي ميثيل بولي سيلوكسان رقيقة (PDMS). Furthermore، لقد أظهرت بنجاح دمج electrospun تيو 2 NF الحصير على جهاز ميكروفلويديك الطرد المركزي المصنوعة من البولي (PC). باستخدام هذا الجهاز، تم التوصل إلى كشف عالية حساسة، مؤتمتة بالكامل، ومتكاملة من البروتين سي التفاعلي (CRP)، وكذلك التروبونين القلبي الأول (cTnI) في غضون 30 دقيقة من فقط 10 ميكرولتر من الدم الكامل. 21 نظرا لمجتمعة مزايا خصائص NFS ومنصة الطرد المركزي، أظهر فحص مجموعة واسعة ديناميكية من ستة أوامر من حجم من 1 غ / مل (~ 8 FM) إلى 100 نانوغرام / مل (~ 12:08) مع الحد الأدنى من الكشف 0.8 غ / مل (~ 6 FM) لCRP ومجموعة ديناميكية من 10 جزء من الغرام / مل (~ 12:04) إلى 100 نانوغرام / مل (~ 4 نانومتر) مع حد الكشف عن 37 جزء من الغرام / مل (~ 01:05) لcTnI. هذه الحدود هي كشف ~ 300 و~ 20 أضعاف أقل مقارنة نتائجها ELISA التقليدية المقابلة. ويمكن تطبيق هذه التقنية للكشف عن أي البروتينات المستهدفة، مع الأجسام المضادة المناسبة. عموما، هذا الجهاز المشتركيونيتبول تسهم إلى حد كبير في في المختبر تشخيص وفحوصات الكيمياء الحيوية نظرا لأنه يمكن الكشف عن كميات نادرة من البروتينات المستهدفة مع حساسية كبيرة حتى من كميات صغيرة جدا من العينات البيولوجية، على سبيل المثال، 10 ميكرولتر من الدم الكامل. على الرغم من أننا تظاهر فقط الكشف عن بروتين مصل باستخدام الاليزا في هذه الدراسة، ونقل ودمج التكنولوجيا من electrospun NFS مع أجهزة ميكروفلويديك يمكن تطبيقها على نطاق أوسع في التفاعلات الكيميائية الحيوية الأخرى التي تحتاج إلى مساحة كبيرة لحساسية الكشف عالية.

Protocol

ولفت الدم من أشخاص أصحاء وجمعت في أنبوب جمع الدم: ملاحظة. تم الحصول على الموافقة المسبقة الخطية من جميع المتطوعين. 1. تصنيع تيو 2 NF حصير إعداد الحل السلائف 22</e…

Representative Results

باستخدام هذا البروتوكول، جهاز ميكروفلويديك الطرد المركزي مؤتمتة بالكامل للكشف عن البروتين من الدم الكامل مع أعد حساسية عالية. وقبل عمليات العزل الكهربائي والتكليس أعدت تيو 2 الحصير NF. من أجل افتعال NFS من القطر المطلوب، التشكل، وسمك، العزل الك…

Discussion

الفحص على تيو 2 NF قرص مدمج هي تقنية سريعة وغير مكلفة وسهلة للكشف عن فائق الحساسية من بروتينات وفيرة المنخفضة الحالية في حجم منخفض جدا من الدم. هذا الأسلوب له ميزة استخدام كميات عينة صغيرة (10 ميكرولتر)، وهي قابلة للتحليل عينات متعددة في وقت واحد. وهذا يوفر إمكانات …

Declarações

The authors have nothing to disclose.

Acknowledgements

وأيد هذا العمل من قبل مؤسسة أبحاث الوطني الكوري (جبهة الخلاص الوطني) منح (2013R1A2A2A05004314، 2012R1A1A2043747)، منحة من كوريا صحة التكنولوجيا R & مشروع التطوير، وزارة الصحة والرعاية الاجتماعية (A121994) وIBS-R020-D1 بتمويل من الحكومة الكورية.

Materials

Si wafer LG SILTRON Polished Wafer, test grade Dia. (mm) = 150, orientation = <100>, dopant = boron, RES(Ohm-cm) = 1 – 30, thickness (μm) = 650 – 700
Polycarbonate (PC)  Daedong Plastic PCS#6900 Thickness (mm) = 1 and 5 
Titanium tetraisopropoxide, 98%, Sigma-Aldrich 205273
Polyvinylpyrrolidone, Mw = 1,300,000 Sigma-Aldrich 437190
Acetic acid Sigma-Aldrich 320099
Anhydrous ethanol Sigma-Aldrich 459836
Tridecafluoro-1,1,2,2-tetrahydrooctyl)-1-trichlorosilane Sigma-Aldrich 448931
PDMS and curing agent Dow Corning SYLGARD 184
GPDES Gelest Inc SIG5832.0 
Ethanol J T Baker
FE-SEM FEI Nova NanoSEM
X-ray photoelectron spectroscopy ThermoFisher K-alpha
3D modeling machine M&I CNC Lab, Korea CNC milling machine
Wax-dispensing machine Hanra Precision Eng. Co. Ltd., Korea Customized
Double-sided adhesive tape FLEXcon, USA DFM 200 clear 150 POLY H-9 V-95
Cutting plotter Graphtec Corporation, Japan Graphtec CE3000-60 MK2
Spin coater MIDAS SPIN-3000D
Furnace (calcination) R. D. WEBB COMPANY WEBB 99
Rheometer (Tack test) Thermo Scientific Haake MARS III – ORM Package
Oxygen plasma system FEMTO CUTE
Monoclonal mouse antihuman hsCRP Hytest Ltd., Finland 4C28 (clone # C5)
Monoclonal mouse anti-cTnI Hytest Ltd., Finland 4T21 (clone # 19C7)
HRP conjugated goat polyclonal anti-hsCRP Abcam plc., MA ab19175
HRP conjugated mouse monoclonal anti-cTnI Abcam plc., MA ab24460 (clone # 16A11)
hsCRP Abcam plc., MA ab111647
cTnI Fitzgerald, MA 30-AT43
Bovine Albumin Sigma-Aldrich A7906
PBS Amresco Inc E404
Blood collection tubes BD vacutainer 367844 K2 EDTA 7.2 mg plus blood
collection tubes
SuperSignal ELISA femto Invitrogen 37074
Modular multilabel plate reader Perkin Elmer Envision 2104
Disc operating machine Hanra Precision Eng. Co. Ltd., Korea Customized
Photomultiplier tube (PMT) Hamamatsu Photonics H1189-210
AutoCAD AutoDesk Version 2012 Design software
SolidWorks 3D CAD software  SOLIDWORKS Corp. Version 2013 3D Design software,
Edgecam Vero software version 2009.01.06928 Code generating software
DeskCNC Carken Co. version 2.0.2.18 CNC milling machine software

Referências

  1. Zhang, Y., et al. Nanomaterials for Ultrasensitive Protein Detection. Adv. Mater. 25 (28), 3802-3819 (2013).
  2. Hu, W., Li, C. M. Nanomaterial-based advanced immunoassays. Wiley Interdiscip. Rev. Nanomed. Nanobiotechnol. 3 (2), 119-133 (2011).
  3. Yang-Kyu, C., Chang-Hoon, K. Silicon Nanowire Biosensor for Cancer Markers. Biosensors and Cancer. , 164-183 (2012).
  4. Baltazar, R., Vistas, C. R., Ferreira, G. M. Biosensing Applications Using Nanoparticles. Nanocomposite Particles for Bio-Applications. , 265-282 (2011).
  5. Roy, P., Berger, S., Schmuki, P. TiO2 Nanotubes: Synthesis and Applications. Angew. Chem. Int. Ed. 50 (13), 2904-2939 (2011).
  6. Yang, D., et al. Electrospun Nanofibrous Membranes: A Novel Solid Substrate for Microfluidic Immunoassays for HIV. Adv. Mater. 20 (24), 4770-4775 (2008).
  7. Chantasirichot, S., Ishihara, K. Electrospun phospholipid polymer substrate for enhanced performance in immunoassay system. Biosens. Bioelectron. 38 (1), 209-214 (2012).
  8. Zhang, N., et al. Electrospun TiO2 Nanofiber-Based Cell Capture Assay for Detecting Circulating Tumor Cells from Colorectal and Gastric Cancer Patients. Adv. Mater. 24 (20), 2756-2760 (2012).
  9. Ali, M. A., Mondal, K., Singh, C., Dhar Malhotra, B., Sharma, A. Anti-epidermal growth factor receptor conjugated mesoporous zinc oxide nanofibers for breast cancer diagnostics. Nanoscale. 7 (16), 7234-7245 (2015).
  10. Mondal, K., Ali, M. A., Agrawal, V. V., Malhotra, B. D., Sharma, A. Highly Sensitive Biofunctionalized Mesoporous Electrospun TiO2 Nanofiber Based Interface for Biosensing. ACS Appl. Mater. Interfaces. 6 (4), 2516-2527 (2014).
  11. Tu, W., Dong, Y., Lei, J., Ju, H. Low-Potential Photoelectrochemical Biosensing Using Porphyrin-Functionalized TiO2 Nanoparticles. Anal. Chem. 82 (20), 8711-8716 (2010).
  12. Liu, S., Chen, A. Coadsorption of Horseradish Peroxidase with Thionine on TiO2 Nanotubes for Biosensing. Langmuir. 21 (18), 8409-8413 (2005).
  13. Portan, D. V., Kroustalli, A. A., Deligianni, D. D., Papanicolaou, G. C. On the biocompatibility between TiO2 nanotubes layer and human osteoblasts. J.Biomed.Mater.Res. Part A. 100 (10), 2546-2553 (2012).
  14. Dettin, M., et al. Covalent surface modification of titanium oxide with different adhesive peptides: Surface characterization and osteoblast-like cell adhesion. J. Biomed. Mater. Res. Part A. 90 (1), 35-45 (2009).
  15. Kim, W. -. J., et al. Enhanced Protein Immobilization Efficiency on a TiO2 Surface Modified with a Hydroxyl Functional Group. Langmuir. 25 (19), 11692-11697 (2009).
  16. Son, K. J., Ahn, S. H., Kim, J. H., Koh, W. -. G. Graft Copolymer-Templated Mesoporous TiO2 Films Micropatterned with Poly(ethylene glycol) Hydrogel: Novel Platform for Highly Sensitive Protein Microarrays. ACS Appl. Mater. Interfaces. 3 (2), 573-581 (2011).
  17. Kar, P., Pandey, A., Greer, J. J., Shankar, K. Ultrahigh sensitivity assays for human cardiac troponin I using TiO2 nanotube arrays. Lab Chip. 12 (4), 821-828 (2012).
  18. Agarwal, S., Wendorff, J. H., Greiner, A. Use of electrospinning technique for biomedical applications. Polymer. 49 (26), 5603-5621 (2008).
  19. Ding, B., Wang, M., Wang, X., Yu, J., Sun, G. Electrospun nanomaterials for ultrasensitive sensors. Mater. Today. 13 (11), 16-27 (2010).
  20. Liu, Y., Yang, D., Yu, T., Jiang, X. Incorporation of electrospun nanofibrous PVDF membranes into a microfluidic chip assembled by PDMS and scotch tape for immunoassays. ELECTROPHORESIS. 30 (18), 3269-3275 (2009).
  21. Lee, W. S., Sunkara, V., Han, J. -. R., Park, Y. -. S., Cho, Y. -. K. Electrospun TiO2 nanofiber integrated lab-on-a-disc for ultrasensitive protein detection from whole blood. Lab Chip. 15 (2), 478-485 (2015).
  22. Li, D., Xia, Y. Fabrication of Titania Nanofibers by Electrospinning. Nano Lett. 3 (4), 555-560 (2003).
  23. Lombard, M. . SolidWorks 2013 BIBLE. , (2013).
  24. Tickoo, S. . EdgeCAM 11.0 for Manufacturers. , (2007).
  25. Zhu, R., et al. Improved adhesion of interconnected TiO2 nanofiber network on conductive substrate and its application in polymer photovoltaic devices. Appl. Phys. Lett. 93 (1), 013102 (2008).
  26. Song, M. Y., Ahn, Y. R., Jo, S. M., Kim, D. Y., Ahn, J. -. P. TiO2 single-crystalline nanorod electrode for quasi-solid-state dye-sensitized solar cells. Appl. Phys. Lett. 87 (11), 113113 (2005).
  27. Katsuhiro, O., et al. Electrospinning processed nanofibrous TiO2 membranes for photovoltaic applications. Nanotechnology. 17 (4), 1026-1031 (2006).
check_url/pt/54143?article_type=t

Play Video

Citar este artigo
Park, Y., Sunkara, V., Kim, Y., Lee, W. S., Han, J., Cho, Y. Fully Automated Centrifugal Microfluidic Device for Ultrasensitive Protein Detection from Whole Blood. J. Vis. Exp. (110), e54143, doi:10.3791/54143 (2016).

View Video