JoVE Science Education
Environmental Microbiology
É necessária uma assinatura da JoVE para visualizar este conteúdo.  Faça login ou comece sua avaliação gratuita.
JoVE Science Education Environmental Microbiology
Isolation of Fecal Bacteria from Water Samples by Filtration
  • 00:00Visão Geral
  • 01:37Principles of Membrane Filtration for Indicator Bacteria
  • 03:48Water Sample Collection and Processing
  • 06:01Colony Identification
  • 07:16Colony Verification
  • 09:23Applications
  • 10:26Summary

通过过滤水样粪便细菌的分离

English

COMPARTILHAR

Visão Geral

资料来源: 实验室的博士伊恩胡椒和博士查尔斯称-亚利桑那大学
演示作者: 路易莎 Ikner

注定要在农业、 娱乐,和国内的设置中使用的水的质量具有重要的意义,因势而为水性疾病的爆发。微生物制剂卷入这类事件包括寄生虫、 细菌和脱落的病毒在粪便中的受感染的人和动物的高数量。传输到新的和易受影响的主机然后可能通过粪-口途径摄入被污染的水后出现。因此,能够监控水源为病原微生物的存在是为了确保公共卫生重大。

由于数量和各种潜在的粪-口病原体,可能会出现在水和它们变的浓度,它是不切实际和昂贵,直接为每一条进行定期检测。因此,微生物检测方法研究水质监测采用细菌大肠菌群指标。大肠菌群组成、 在第一部分,肠道正常菌群的温血哺乳动物、 具有非致病性的和一贯地排泄的粪便。因此,水中大肠菌群的检测手段,粪便释放发生,和有害病原微生物可能也会出现。

Princípios

Procedimento

1.水样本采集和处理 从测试水源收集几个 1-L 水样 (如水喷泉、 游泳池、 水库、 配水系统,生食或处理后的污水),和微生物分析实验室的冰上运输。 灭菌或消毒膜过滤多方面的大会之前,使用高压蒸汽灭菌,暴露于紫外线辐射 (2 分钟) 或乙醇火焰点火。 冷却时的所有零件,正确连接到真空泵和真空过滤废物瓶含漂白剂的流形。 乙醇-火焰消毒一双钳和与…

Applications and Summary

Membrane filtration is used in virus capture and concentration from water. Human pathogenic viruses carry a net negative charge in aquatic solutions, and are often present at low levels in water sources. Therefore they must be concentrated prior to analysis. Membrane filtration is but one capture method for this purpose, and employs a negatively-charged filter. Water samples (e.g. 1-L) of interest are amended with a salt solution (e.g. magnesium chloride) to impart a positive charge to the viruses, thereby facilitating their adsorption to the negatively-charged HA membrane filter as the water is filtered. A low concentration acid solution is used to rinse the membrane and rid it of excess salts. A low concentration and volume of sodium hydroxide is then used to release the viruses from the filter prior to further concentrations and analyses (e.g. cell culture infectivity assays or quantitative PCR).

Membrane filtration is also utilized in the production of high-purity process water for industrial use. Many industries require highly purified water for their operational processes. Membrane filtration (e.g. nano-filtration) serves to remove contaminants including dissolved metals and salts from water. Membrane filtration is also used in the desalination of salt water to produce potable water.

Transcrição

Membrane filtration and the subsequent culturing of bacteria collected is a useful technique to assess the quality and cleanliness of a water source.

The quality of water destined for use in agricultural, recreational, or domestic settings is of great importance, due to the potential for outbreaks of waterborne disease. If water is contaminated with fecal matter from animals or humans, then pathogenic parasites, bacteria, or viruses may be spread to new hosts upon their ingestion. Monitoring water sources for such disease-causing organisms is therefore critical to ensure public health.

The sheer number and variety of fecal-oral pathogens that may be present in a water source makes it impractical to assay for each independently and on a regular basis. Instead, common microbiological assays for water quality utilize coliform indicator bacteria. For more information on this process, see this collection’s video on indicator organisms.

This video will illustrate the process of membrane filtration on an environmental water sample, demonstrate how to culture several types of fecal indicator bacteria including total coliforms, fecal coliforms, and fecal entercocci, and describe how to verify the presence of fecal contamination.

Membrane filtration technique utilizes negative pressure to draw water samples across a filter and trap bacteria. The filter is a specialized membrane with a minimal mean pore size of 0.45 μm that allows the capture of bacteria, which are typically around 1 μm in size. After filtration, the membrane is applied to agarose growth media, and incubated at conditions appropriate to culture the target microorganisms.

This technique is most ideal for low turbidity sources such as drinking water, swimming pools, or lakes and reservoirs. Water high in particulate matter content can result in fouling or clogging of the filter, limiting the volume that can be processed. Additionally, membrane filtration is not practical for water sources containing large numbers of background, or non-coliform bacteria, like raw sewage, as this can increase the difficulty of enumerating target coliforms upon culture and incubation.

Once bacterial samples have been trapped in the filter, they can be transferred to growth plates to determine the types of indicator bacteria present in the water samples. Plating on different media types selects for different bacterial types, and can allow for rapid identification.

After growth on culture specific plates, further confirmation of indicator bacteria identities can be carried out using techniques such as picking colonies into liquid media and using Durham tubes to capture gases, which should only be produced in the presence of fecal coliforms or total coliforms. Additionally, suspected fecal enterococci can be confirmed by a combination of a positive Gram staining, along with a negative hydrogen peroxide-catalase test.

Now that we are familiar with the principles behind the membrane filtration of water samples, let’s take a look at how this procedure is carried out.

To begin the procedure, first collect water samples from test water sources of interest. Ensure the samples are collected in sterile 1-L bottles. Once collection is complete, put the samples on ice, and transport them to the laboratory for microbial analysis.

To begin the analysis, first sterilize a membrane filtration manifold. Next, connect the manifold to a vacuum pump and filtration waste flask containing bleach.

Ethanol flame-sterilize forceps and remove a sterile gridded membrane from the packaging. Place the filter onto the center of the membrane filtration area of the manifold, and apply a sterile filter funnel to the unit, then secure in place.

Measure out a desired volume of test water into the funnel. Apply a partial vacuum to draw the test sample through the filter. Suspended solid material, including bacteria and other organic matter, greater than 0.45 μm will be trapped on or within the filter, while smaller particles, viruses, and dissolved solids will pass though into the waste flask containing bleach.

After the sample has passed through the filter, rinse the interior of the funnel with 25 mL of sterile water 3 times, allowing this to pass through the filter. When the final rinse is complete, disconnect the vacuum and remove the funnel from the manifold.

Next, ethanol flame-sterilize forceps and immediately remove the membrane filter from the unit. Place it onto the appropriate growth plate for the target microorganism using a rolling motion to ensure complete contact with the surface and avoid trapping air bubbles.

For the processing of each further sample, sanitize the stainless steel manifold and use a sterile funnel to prevent cross contamination. Finally, place the plates into an incubator for the appropriate incubation period.

Following the incubation period, remove the plates from the incubator for enumeration. If possible, perform the colony counts under low power magnification using a cool white light source. To determine total coliforms, identify and count colonies that appear pink to dark red in color, and have a metallic surface sheen fully or partially covering the colony. Atypical total coliform colonies may appear dark red, mucoid, or nucleated without sheen.

Colonies that appear blue, white, colorless, or pink without sheen are considered non-coliforms, and should not be included in the total coliforms count.

Fecal coliform colonies will appear as various shades of blue, and these should be counted as a separate category. Non-fecal coliform colonies are typically grey to cream in color, and should also be recorded in an individual category. Finally, fecal enterococci colonies will range from pink to dark red in color and should be counted separately.

To verify total coliform colonies, apply a sterilized and cooled inoculating loop to a single colony of interest. Transfer the selected colony into a glass vessel containing lauryl tryptose broth and a Durham tube. Next, place the cultures into an incubator. The presence of turbidity along with gas production captured by the Durham tube verifies the colony as a total coliform.

For fecal coliform verification, aseptically transfer colonies blue in color into glass vessels containing sterile EC medium and a Durham tube. Place the inoculated tubes into an incubator. After incubation, turbid inoculates in conjunction with gas production confirm the colony to be a fecal coliform.

To confirm fecal enterococci, aseptically transfer suspected colonies with the correct morphology onto Brain-Heart Infusion Agar plates, and incubate. Next, transfer growth from an isolated colony on BHIA onto two sterile glass slides.

Add 2-3 drops of 3% hydrogen peroxide to one of the glass slides. Rapid gas production indicates a catalase-positive bacterium such as Citrobacter. Fecal enterococci bacteria are catalase negative; therefore, no bubbling is observed. For catalase-negative colonies that don’t display bubbling, perform a Gram stain. As fecal enterococci, these should appear Gram positive, ovoid in shape, and be grouped mostly in pairs or short chains.

Finding any of these indicator bacteria in a water source indicates the presence of a contamination. If more than 5% of samples are found to be contaminated over a one-month period, the source may be considered unfit for human consumption.

Membrane filtration is commonly used in a number of biological applications, and fecal indicator organisms can also be detected by other experimental procedures. Some of these applications are explored here.

Membrane filtration can also be used in virus capture from water samples. As viruses will typically be present at very low levels, water samples must be concentrated in order to capture them for analysis. Captured viruses can then be released from the filters, and identified using techniques such as cell culture infectivity assays or PCR.

Membrane filtration is also utilized in the production of high purity water for industrial or laboratory use. Many industries require highly purified water for their operational processes, and membrane filtration can serve to remove contaminants, including unwanted dissolved metals and salts from water. It can also be used in the desalination of salt water to produce potable water.

You’ve just watched JoVE’s introduction to identifying indicator organisms in water by membrane filtration. You should now understand how to membrane filter water samples, how to culture several types of fecal indicator bacteria from the membrane, and how to confirm these as indicator organisms. Thanks for watching!

Tags

Cite This
JoVE Science Education Database. JoVE Science Education. Isolation of Fecal Bacteria from Water Samples by Filtration. JoVE, Cambridge, MA, (2023).

Vídeos Relacionados