A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Synthesis of Phase-shift Nanoemulsions with Narrow Size Distributions for Acoustic Droplet Vaporization and Bubble-enhanced Ultrasound-mediated Ablation

10.8K views

⸱

DOI:

10.3791/4308

⸱

September 13th, 2012

 ,  ,  , 

In This Article

Summary

Phase-shift nanoemulsions (PSNE) can be vaporized using high intensity focused ultrasound to enhance localized heating and improve thermal ablation in tumors. In this report, the preparation of stable PSNE with a narrow size distribution is described. Furthermore, the impact of vaporized PSNE on ultrasound-mediated ablation is demonstrated in tissue-mimicking phantoms.

Abstract

High-intensity focused ultrasound (HIFU) is used clinically to thermally ablate tumors. To enhance localized heating and improve thermal ablation in tumors, lipid-coated perfluorocarbon droplets have been developed which can be vaporized by HIFU. The vasculature in many tumors is abnormally leaky due to their rapid growth, and nanoparticles are able to penetrate the fenestrations and passively accumulate within tumors. Thus, controlling the size of the droplets can result in better accumulation within tumors. In this report, the preparation of stable droplets in a phase-shift nanoemulsion (PSNE) with a narrow size distribution is described. PSNE were synthesized by sonicating a lipid solution in the presence of liquid perfluorocarbon. A narrow size distribution was obtained by extruding the PSNE multiple times using filters with pore sizes of 100 or 200 nm. The size distribution was measured over a 7-day period using dynamic light scattering. Polyacrylamide hydrogels containing PSNE were prepared for in vitro experiments. PSNE droplets in the hydrogels were vaporized with ultrasound and the resulting bubbles enhanced localized heating. Vaporized PSNE enables more rapid heating and also reduces the ultrasound intensity needed for thermal ablation. Thus, PSNE is expected to enhance thermal ablation in tumors, potentially improving therapeutic outcomes of HIFU-mediated thermal ablation treatments.

Protocol

1. Preparation of Phase-shift Nanoemulsion (PSNE)

  1. Dissolve 11 mg DPPC and 1.68 mg DSPE-PEG2000 in chloroform
  2. Evaporate the organic solvent to form a dry lipid film in a glass round-bottom flask
  3. Dessicate the lipid film overnight
  4. Rehydrate the lipid film with 5.5 ml of phosphate-buffered saline (PBS)
  5. Heat solution in a 45 °C water bath until lipid film dissolves, vortexing periodically
  6. Transfer lipid solution into 7 ml vial
  7. Sonicate lipid solution for 2 min at 20% amplitude
  8. Divide solution into two vials of 2.5 ml each (discard remaining 0.5 ml)
  9. Add 2.....

Access restricted. Please log in or start a trial to view this content.

Discussion

High-intensity focused ultrasound (HIFU) is used clinically to thermally ablate tumors.1 To enhance localized heating and improve thermal ablation in tumors, lipid-coated perfluorocarbon droplets have been developed which can be vaporized by HIFU. The vasculature in many tumors is abnormally leaky due to their rapid growth.2 Thus, nanoparticles are able to penetrate the fenestrations and passively accumulate within tumors, a process known as the enhanced permeability and retention (EPR) effect.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Acknowledgements

This work was supported by a BU/CIMIT Applied Healthcare Engineering Predoctoral Fellowship, a National Science Foundation Broadening Participation Research Initiation Grant in Engineering (BRIGE), and the National Institutes of Health (R21EB0094930).

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
DPPCAvanti Lipids, Alabaster, AL, USA850355P1,2-dipalmitoyl-sn-glycero-3-phosphocholine
DSPE-PEG2000Avanti Lipids, Alabaster, AL, USA880120P1,2-distearoyl-sn-glycero-3-phosph–thanolamine-N-[methoxy(polyethylene glycol)-2000] (ammonium salt)
DDFPFluoromed, Round Rock, TX, USACAS: 138495-42-8Dodecafluoropentane (C5F12)
PBSSigma-Aldrich, St. Louis, MO, USAP2194Phosphate-buffered saline
ChloroformSigma-Aldrich, St. Louis, MO, USA372978Chloroform
AcrylamideSigma-Aldrich, St. Louis, MO, USAA992640% 19:1 acrylamide/bis-acrylamide
Tris bufferSigma-Aldrich, St. Louis, MO, USAT26941M, pH 8, trizma hydrochloride and trizma base
BSASigma-Aldrich, St. Louis, MO, USAA3059Bovine serum albumin
APSSigma-Aldrich, St. Louis, MO, USAA3678Ammonium persulfate solution
TEMEDSigma-Aldrich, St. Louis, MO, USA87689N,N,N',N'-Tetramethylethylenediamine
Equipment
Sonicator (3 mm tip)Sonics Materials, Inc., Newtown, CT, USAVibra-Cell
Water bathThermo Fisher Scientific, Waltham, MA, USANeslab EX-7
ExtruderNorthern Lipids, Burnaby, BC, CanadaLIPEX
Extruder FiltersWhatman, Piscataway, NJ, USANuclepore #110605 and #110606
Extruder Drain DiscSterlitech Corporation, Kent, WA, USA#PETEDD25100
Plastic chamberU.S. Plastic Corporation, Lima, OH, USA#55288, 1 3/16"x1 3/16"x2 7/16"

References

  1. Hynynen, K., Darkazanli, A., Unger, E., Schenck, J. F. MRI-guided noninvasive ultrasound surgery. Med. Phys. 20, 107-115 (1993).
  2. Baban, D. F., Seymour, L. W. Control of tumour vascular permeability. Adv. Drug Deliv. Rev. 34, 109-119 (1998).
  3. Maeda, H., Wu, J., Sawa, T., Matsumura, Y., Hori, K.....

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Narrow Size DistributionDynamic Light ScatteringExtrusion ProtocolLipid Coated DropletsBubble Enhanced HeatingHIFU Thermal AblationPolyacrylamide Hydrogel