Waiting
Login processing...

Trial ends in Request Full Access Tell Your Colleague About Jove

Medicine

Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact

Published: February 10, 2015 doi: 10.3791/51717

Summary

This report presents details of how to adopt the acromion marker cluster method of obtaining scapular kinematics when using a passive marker motion capture device. As has been described in the literature, this method provides a robust, non-invasive, three-dimensional, dynamic and valid measurement of scapular kinematics, minimizing skin movement artifact.

Abstract

The measurement of dynamic scapular kinematics is complex due to the sliding nature of the scapula beneath the skin surface. The aim of the study was to clearly describe the acromion marker cluster (AMC) method of determining scapular kinematics when using a passive marker motion capture system, with consideration for the sources of error which could affect the validity and reliability of measurements. The AMC method involves placing a cluster of markers over the posterior acromion, and through calibration of anatomical landmarks with respect to the marker cluster it is possible to obtain valid measurements of scapular kinematics. The reliability of the method was examined between two days in a group of 15 healthy individuals (aged 19-38 years, eight males) as they performed arm elevation, to 120°, and lowering in the frontal, scapular and sagittal planes. Results showed that between-day reliability was good for upward scapular rotation (Coefficient of Multiple Correlation; CMC = 0.92) and posterior tilt (CMC = 0.70) but fair for internal rotation (CMC = 0.53) during the arm elevation phase. The waveform error was lower for upward rotation (2.7° to 4.4°) and posterior tilt (1.3° to 2.8°), compared to internal rotation (5.4° to 7.3°). The reliability during the lowering phase was comparable to results observed during the elevation phase. If the protocol outlined in this study is adhered to, the AMC provides a reliable measurement of upward rotation and posterior tilt during the elevation and lowering phases of arm movement.

Introduction

Objective, quantitative measurement of scapular kinematics can provide an assessment of abnormal movement patterns associated with shoulder dysfunction1, such as reduced upward rotation and posterior tilt during arm elevation observed in shoulder impingement2-8. Measurement of scapular kinematics, however, is difficult due to the bone’s deep position and gliding nature beneath the skin surface1. Typical kinematic measurement techniques of attaching reflective markers over anatomical landmarks do not adequately track the scapula as it glides beneath the skin surface9. Various methods have been adopted throughout the literature to overcome these difficulties, including; imaging (X-ray or magnetic resonance)10-14, goniometers15,16, bone pins17-22, manual palpation23,24, and the acromion method3,5,19,25. Each method, however, has its limitations which include: exposure to radiation, projection errors in the case of two-dimensional image based analysis, require repeated subjective interpretation of the location of the scapula, are static in nature or are highly invasive (e.g. bone pins).

A solution to overcome some of these difficulties is to employ the acromion method where an electromagnetic sensor is attached to the flat portion of the acromion25, a flat portion of bone which extends anteriorly at the most lateral part of the scapula leading from the spine of the scapula. The principle idea behind using the acromion method is to reduce skin movement artifact, as the acromion has been shown to have the least amount of skin movement artifact compared to other sites on the scapula26. The acromion method is non-invasive and provides dynamic three-dimensional measurement of scapular kinematics. Validation studies have shown the acromion method to be valid up to 120° during the arm elevation phase when using electromagnetic sensors17,27. When using marker based motion capture devices a series of markers arranged in a cluster, the acromion marker cluster (AMC), is required and has been shown to be valid when using an active-marker motion capture system28 and whilst using a passive-marker motion capture system during arm elevation and arm lowering29.

The use of the AMC with a passive marker motion capture device for measuring scapular kinematics has been used to assess changes in scapular kinematics following an intervention to address shoulder impingement30. The valid use of this method, however, depends on the ability to accurately apply the cluster of markers, the position of which has been shown to affect results31, calibrate anatomical landmarks32 and ensuring arm movements are within a valid range of motion (i.e. below 120° arm elevation)29. It has also been suggested the reapplication of the marker cluster, when using an active marker based motion capture system, was found to be the source of increased error for scapular posterior tilt28. It is, therefore, important to establish the between-day reliability of the acromion method to ensure it provides a stable measure of scapular kinematics. Ensuring that measurements are reliable will enable changes in scapular kinematics, due to an intervention, for example, to be measured and examined. The methods used to measure scapular kinematics have been described elsewhere29,33; the aim of the present study was to provide a step-by-step guide and reference tool for applying these methods using a passive-marker motion capture system, with consideration to the potential sources of error, and to examine the reliability of the measurement method.

Subscription Required. Please recommend JoVE to your librarian.

Protocol

NOTE: The use of human participants was approved by the Faculty of Health Sciences Ethics Committee at the University of Southampton. All participants signed consent forms before data collection commenced. For the data presented in this study kinematics were recorded using a passive marker motion capture system consisting of 12 cameras; six 4-megapixel cameras and six 16-megapixel cameras operating at sampling frequency of 120 Hz.

1. Participant Preparation

  1. Ask subjects to remove their upper body clothing or to wear a sports bra, vest, or strapless top. It is important that clothing does not interfere with the movement of the markers or occlude markers from the view of the cameras.
  2. Construct an acromion marker cluster consisting of an ‘L’ shaped piece of plastic 70 mm in length along each aspect. Attach three retroreflective markers to the AMC, one on the end of each end of each aspect and one where each aspect meet (Figure 1).
  3. Attach the acromion marker cluster (AMC) onto the posterior portion of the acromion where the acromion meets the scapular spine, using double sided adhesive tape. One aspect of the plate should follow the spine of the scapula pointing medially, the other should point anterior to the scapular plane (Figure 1).
  4. Attach a cluster marker set to the upper arm using straps (Figure 2).
  5. Attach retroreflective markers to the following anatomical landmarks at recommended by the International Society of Biomechanics33 (Figures 1 & 2): Sternal notch (IJ; Deepest joint of the sternal notch), Xiphoid process (PX; Most caudal point on the sternum), C7 (Spinous process of the C7 vertebra), T8 (Spinous process of the T8 vertebra), Sternoclavicular joint (SC; Most ventral point on the sternoclavicular joint), Radial styloid (Most caudal point on the radial styloid), and Ulnar styloid (Most caudal point on the ulnar styloid).

Figure 1
Figure 1: Position of the acromion marker cluster, C7 and T8 anatomical markers. This figure has been modified from Warner, M. B., Chappell, P. H. & Stokes, M. J. Measuring scapular kinematics during arm lowering using the acromion marker cluster. Hum. Mov. Sci. 31, 386-396, doi:http://dx.doi.org/10.1016/j.humov.2011.07.004 (2012).

Figure 2
Figure 2: Marker locations for the sternal notch (IJ), xiphoid process (PX), sternoclavicular (SC), upper arm cluster, ulnar styloid (US), radial styloid (RS).

2. Participant Calibration

NOTE: Locations of the scapula’s anatomical landmarks need to be determined with respect to the acromion marker cluster. Calibration of the landmarks is required for each participant.

  1. Construct a calibration wand consisting of four reflective markers placed into a ‘T’ formation (Figure 3). Measure the distance from the tip of the calibration wand to the first wand marker.
  2. Palpate and locate the following anatomical landmarks as recommended by the International Society of Biomechanics33. Place the tip of the calibration wand on the landmark (Figure 3). Capture three seconds of data with the motion capture system ensuring the markers on the wand, the AMC and upper arm cluster are all visible to the cameras.
    1. Acromioclavicular joint (AC) — Place a hand on the clavicle, then move laterally until the point where the clavicle reaches the acromion. Place the tip of the wand at the joint between the clavicle and acromion.
    2. Acromion angle (AA) — Palpate along the spine of the scapula to the most lateral point. Place the tip of the wand on the dorsal aspect of the acromion at the most lateral point (Figure 3).
    3. Medial spine of the scapula (TS) — Palpate along the spine of the scapula to the most medial point. Place the tip of the wand at the point where the spine meets the medial border of the scapula.
    4. Inferior angle of the scapula (AI) — Palpate inferiorly along the medial border of the scapula. Place the tip of the wand on the most caudal point of the scapula.
    5. Medial epicondyle (EM) — With the participant’s elbow in 90° of flexion pointing forward, with their thumb pointing upwards, place a hand on the medial side of the elbow to locate the medial epicondyle. Place the tip of the wand on the most caudal point of the medial epicondyle.
    6. Lateral epicondyles (EL) — With the participant’s elbow in 90° of flexion pointing forward, with their thumb pointing upwards, place a hand on the lateral side of the elbow to locate the lateral epicondyle. Place the tip of the wand on the most caudal point of the lateral epicondyle.
  3. To determine the glenohumeral joint center, ask the participant to perform a circumduction movement with their upper arm with the elbow fully extended, from zero degrees arm elevation to approximately 40° arm elevation. They must perform this movement whilst aiming to minimize protraction/retraction and elevation/depression of the shoulder complex; the investigator can provide assistance if necessary. Record this movement for approximately 30 sec.

Figure 3
Figure 3: Calibration wand used to locate anatomical bony landmark with respect the acromion marker cluster (AMC).

3. Experiment Protocol

  1. Ask participant to perform arm elevation from zero to 120° arm elevation, and then lower their arm back down to rest by their side in the sagittal, frontal and scapular plane. The scapular plane is approximately 40° anterior to the frontal plane.

4. Post-processing of Kinematic Data

NOTE: The following steps detail the procedure needed to calculate scapular kinematics during the dynamic movement trials. These steps have been described and explored extensively within the literature21,33,34 and the purpose of the following section is to provide a synthesis and step-by-step guide to implementing the modeling steps required to obtain scapular kinematics. The application of these steps is conducted in relevant kinematic modeling software. The software contains commands to enable the creation of local coordinate systems, the conversion of coordinates from a global to local coordinate system, the conversion of coordinates from local to global coordinate systems and the calculation of Euler angle rotations. These steps will allow the scapula, humerus and thorax to be defined as rigid bodies. Subsequently rotation of the scapula with respect the thorax, and the humerus with respect thorax can then be determined.

  1. Using the coordinates of markers on the AMC, define an arbitrary local coordinate system for the AMC (Figure 4a). For each scapular anatomical landmark calibration trial, determine the location of the tip of the wand, which represents the location of the anatomical landmark, with respect the local coordinate system on the AMC using the following steps.
    NOTE: Kinematic modeling software contain commands to enable the creation of local coordinate systems and conversion of coordinates from a global to a local coordinates, see Figure 4 for example commands.
    1. Use the markers on the wand to create a local coordinate system for the wand (Figure 4a) using the following command in the kinematic modeling software: AMC= [AMCO,AMCA-AMCO,AMCO-AMCM,xyz] where AMCO, AMCA and AMCM are the labels given to the markers on the AMC.
    2. Using the kinematic modeling software, calculate the location of the tip of the wand in the global coordinate system. In the example provided this is 83 mm from the marker 1 (M1) along the X axis of the wand (Figure 4b); use the command: Wand = [M1,M1-M2,M3-M4,xyz] and Wandtip = M1+{83,0,0}*ATTITUDE(Wand) where M1, M2, M3 and M4 are the labels given to the markers on the wand.
    3. Determine the location of the tip of the wand with respect to the local coordinate system of the AMC ($%AA) (Figure 4c) using the modeling commands: $%AA = WandTip/AMC and PARAM($%AA).
    4. Repeat steps 4.1.1 to 4.1.3 for each scapular anatomical landmark.
    5. Determine the location of the medial and lateral epicondyles with respect to the humerus marker cluster, instead of the AMC, using the using the above steps.
  2. Use the dynamic calibration trial to calculate the location of the glenohumeral joint center with respect to the scapula. Calculate the position of the glenohumeral joint center, with respect to the scapula, as the pivot point of the helical axis between the humerus and scapula. For more details on this technique refer to Veeger35.
  3. Calculate the elbow joint center (ELJC) as the mid-distance between the lateral (EL) and medial epicondyles (EM) of the humerus; ELJC = (EM + EL) / 2.
  4. During the dynamic trials, use the known position of the anatomical landmarks with respect to the AMC to determine the location of the anatomical landmarks within the global coordinate system (Figure 5).
    NOTE: Modeling software contain commands to enable conversion of coordinates from local coordinate systems to global coordinate systems, see Figure 5 for example commands.
    1. Refer to Figure 5a that shows the location of the acromion angle landmark with respect to the AMC ($%AA) as described in point 4.1.
    2. Convert the location of $%AA virtual marker to the global coordinate system for each time point during the dynamic trial to create the acromion angle (AA) landmark (Figure 5b) using the following kinematic modeling command: AA = $%AA*AMC and OUTPUT(AA).
    3. Repeat steps 4.4.2 for each anatomical landmark.
  5. Define a local coordinate system for the thorax and scapula by calculating the unit vectors between the relevant markers to represent each axis for a given rigid body using the following kinematic modeling command: Scapula = [AA,TS-AA,AA-AI,zxy]. Thorax = [IJ,MUTHX-MLTHX,IJ-C7,yzx], where MUTHX is the mid-point between the IJ and C7 landmark and MLTHX is the mid-point between the PX and T8 landmarks.
    NOTE: The axes definition are based on International Society of Biomechanics’ (ISB) recommendations33 (Table 1 and Figure 6).
    1. Using a similar method, define a local coordinate system for the humerus using ‘Option 2’ as recommended by the ISB33.
      NOTE: Option 2 requires a sufficient plane formed by the gleohumeral joint center, elbow joint center and the ulna styloid, i.e. a degree of elbow flexion is required. If the participant approaches full elbow extension, the humeral axes may become unstable and therefore ‘Option 1’ should be used (Table 1). See Wu et al. (2005) for further details.
  6. Determine the orientation of the scapula relative to the thorax for each time point during the dynamic trial using the Euler angle decomposition method with a rotation sequence of internal rotation (Y), upward rotation (X’) and posterior tilt (Z’’)33 using the following kinematic modeling command: ScapularKin = -<Thorax,Scapula,yxz> (Figure 7).
  7. Determine the orientation of the humerus with respect to the thorax during the dynamic trial using a non-cardan rotation sequence of Y (plane of elevation), X’ (elevation) and Y’’ (axial rotation)36 using relevant kinematic modeling software.
    NOTE: A macro is available to download from the manufacturer in order to determine non-cardan rotation sequences within the kinematic modeling software used in this manuscript.

Table 1
MUTHX = mid-point between IJ and C7. MLTHX = mid-point between PX and T8. GH = glenohumeral joint center. ELJC = elbow joint center.

Mathematical operators:

^ = cross product of two vectors

|| = absolute value of a vector

Table 1: Local coordinate system for each rigid segment.

5. Data Reduction and Analysis

NOTE: The following data reduction and analysis steps are performed in numerical modeling software (such as MATLAB) that allows manipulation of data matrices. The kinematic data is divided into the elevation and lowering phases of humeral movement, time normalized for each phase of movement, then scapular kinematics are expressed relative to humeral elevation angle.

  1. Determine the elevation and lowering phase of the humeral elevation as described below (Figure 8). These phases are determined from the angular velocity of the humeral elevation angle (Figure 8). See ElevationLoweringPhases.m function file.
    1. Determine the start of humeral elevation when the angular velocity of the humerus exceeds a threshold 2% of the maximal humeral angular velocity.
    2. Determine the end of the elevation phase as the point at which the humeral angular velocity falls below 2% of the maximal humeral angular velocity, or when humeral elevation exceeds 120°.
    3. Determine the start of the humeral lowering phase when the angular velocity falls below 2% of the minimum angular velocity, or the point at which humeral elevation falls below 120°.
    4. Determine the end of the lowering phase when the angular velocity exceeds 2% of the minimum angular velocity.
  2. Normalize the data by interpolating the kinematic data in each phase of movement to 101 data points (Figure 9). See Time_normalisation.m function file.
  3. Express scapular kinematics in relation to humeral elevation by plotting the arm angle (degrees) vs. upward rotation (degrees) (Figure 10). See PlotScapHumRhythm.m function file.

Subscription Required. Please recommend JoVE to your librarian.

Representative Results

Fifteen participants who had no known history of shoulder, neck or arm injuries were recruited onto the study (Table 2). To assess intra-rater (between-day) reliability, participants attended two data collection sessions separated by at least 24 hours and a maximum of 7 days. During each data collection session, the same investigator performed the protocol for attaching reflective markers, the acromion marker cluster and anatomical landmark calibrations, as detailed above. The reliability of the kinematic waveform obtained from dynamic trials was assessed using coefficient of multiple correlation (CMC)37. Waveform measurement error was used to assess the amount of error between days (σb)38.

Age (years) Weight (kg) Height (m) Body mass index (kg/m²)
Group (n=15) 24.9 ± 4.4 65.8 ± 11.7 1.7­± 0.1 22.6 ± 2.3
19 – 38 48 – 86 1.5 – 1.9 18.3 – 36.5
Males (n=8) 25.1 ± 1.5 73.4 ± 9.9 1.8 ± 0.06 23.2 ± 2.4
23 – 27 62 – 86 1.7 – 1.9 19.8 – 26.4
Females (n=7) 24.6 ± 1.5 57 ± 6.3 1.6 ± 0.06 21.9 ± 2.2
23 – 27 48 – 68.5 154 – 170 18.3 – 24.2

Table 2. Participant demographics, mean ± standard deviation (SD) and range.

The intra-rater (between-day) reliability produced high CMC (>0.92) for upward rotation and posterior tilt (>0.69) during humeral elevation and lowering in all planes of arm movement. Internal rotation demonstrated lower CMC values (0.44 to 0.76) during all planes of arm elevation and lowering (Table 3). This was also reflected in the waveform measurement error with generally lower error values for upward rotation (σb = 2.7° to 4.4°) and posterior tilt (σb = 1.3° to 2.8°), indicating good reliability, compared to internal rotation (σb = 3.9° to 7.3°) (Table 3). There did not appear to be any bias between days, with similar waveform patterns obtained for upward rotation, posterior tilt and internal rotation during both the elevation and lowering phases (Figure 10).

Figure 4
Figure 4. A) Local coordinate system of the acromion marker cluster (AMC) as determined by the three markers on the AMC (AMCO, AMCA, AMCM). B) Local coordinate system of the wand using the four markers attached to the wand (M1, M2, M3, and M4). The tip of the wand is subsequently calculated as a point 83 mm from the M1 marker along the X axis of the wand. C) The location of the tip of the wand, which represents the location of the anatomical landmark within the global coordinate system, is determined with respect to the local coordinate system of the AMC. Example kinematic modeling commands are given for each step. This figure has been modified from Warner, M. B., Chappell, P. H. & Stokes, M. J. Measuring scapular kinematics during arm lowering using the acromion marker cluster. Hum. Mov. Sci. 31, 386-396, doi:http://dx.doi.org/10.1016/j.humov.2011.07.004 (2012).

Figure 5
Figure 5. A) The location of the acromion angle landmark with respect to the local coordinate system of the acromion marker cluster. B) The conversion of the acromion angle (AA) landmark from the local to the global coordinate system (black axes).

Figure 6
Figure 6. Local coordinate system of the scapula defined by the locations of the acromion angle (AA), medial spine of the scapula (TS) and the inferior angle (AI) following International Society of Biomechanics Recommendations. Example kinematic modeling commands are provided. This figure has been modified from Warner, M. B., Chappell, P. H. & Stokes, M. J. Measuring scapular kinematics during arm lowering using the acromion marker cluster. Hum. Mov. Sci. 31, 386-396, doi:http://dx.doi.org/10.1016/j.humov.2011.07.004 (2012).

Figure 7
Figure 7. Euler angle rotations of the scapula around each axis, with respect to the thorax, following a rotation sequence of internal rotation (Y), upward rotation (X’) and posterior tilt (Z”). This figure has been modified from Warner, M. B., Chappell, P. H. & Stokes, M. J. Measuring scapular kinematics during arm lowering using the acromion marker cluster. Hum. Mov. Sci. 31, 386-396, doi:http://dx.doi.org/10.1016/j.humov.2011.07.004 (2012).

Figure 8
Figure 8. A) Humeral elevation and lowering with the start and end of each phase denoted by the green dotted lines. B) Humeral angular velocity used to determine the start and end of each phase. The uppermost red dashed line represents the threshold used to determine the start and end of the elevation phase. The lowermost red dashed line represents the threshold used to determine the start and end of the lowering phase. Green dotted lines represent the points at which the angular velocity exceeded the thresholds.

Figure 9
Figure 9. Scapular upward rotation during arm elevation that has been interpolated over 101 data points to normalize with respect to time.

Figure 10
Figure 10. Kinematic waveforms of the scapula for day one (black) and day two (grey). Scapular rotations during sagittal plane arm movement shown are; upward rotation during the elevation (A) and lowering phase (B), posterior tilt during the elevation (C) and lowering phase (D) and internal rotation during the elevation (E) and lowering phase (F). Dashed lines represent ±1 standard deviation.

Scapular rotation Phase of arm movement Sagittal plane Scapular plane Frontal plane
CMC Waveform error CMC Waveform error CMC Waveform error
Internal rotation Elevation 0.44 ± 0.3 7.3° ± 1.6 0.50 ± 0.2 6.7° ± 0.8 0.44 ± 0.3 3.9° ± 1.5
Upward rotation 0.93 ± 0.1 3.1° ± 1.6 0.94 ± 0.1 3.4° ± 1.0 0.93 ± 0.1 2.7° ± 1.5
Posterior tilt 0.69 ± 0.2 2.3° ± 0.9 0.78 ± 0.2 1.4° ± 0.5 0.82 ± 0.2 1.3° ± 0.3
Internal rotation Lowering 0.53 ± 0.3 7.0° ± 1.4 0.45 ± 0.2 7.2° ± 1.1 0.76 ± 0.2 5.4° ± 2.9
Upward rotation 0.94 ± 0.0 4.4° ± 1.0 0.92 ± 0.1 4.3° ± 1.1 0.94 ± 0.1 3.9° ± 1.7
Posterior tilt 0.70 ± 0.2 2.5° ± 1.4 0.77 ± 0.2 1.8° ± 0.9 0.87 ± 0.1 2.8° ± 0.8

CMC = Coefficient of multiple correlation.

Table 3. Intra-rater (between-days) reliability of the acromion marker cluster as determined by the coefficient of multiple correlation and waveform error.

Subscription Required. Please recommend JoVE to your librarian.

Discussion

The choice of methodology for determining scapular kinematics is crucial, and consideration of the validity, reliability and its appropriateness for the research study should be given. Various methods have been adopted throughout the literature but each method has its limitations. The acromion marker cluster overcomes a number of these limitations, such as projection errors from 2D imaging or requiring repeated interpretation of the location of the scapula by providing non-invasive dynamic kinematic measurement of the scapula. However, the AMC method is still susceptible to skin movement artifact, particularly at higher arm elevation angles and brings into question the validity of the method at these higher arm positions. A previous study that assessed the validity of the method outlined in the present study, has shown that at arm elevation above 120 degrees the measurement error becomes too large and the method is no longer valid29. However, the study also demonstrated that when the arm returns to a position below 120 degrees following arm high arm elevation the acromion marker cluster method remains valid29. It is possible to reduce the errors at higher arm elevation angles by performing the calibration of the anatomical landmarks with the arm elevated32. However, this increases the error at lower arm elevation angles. Therefore, it is important to consider the aims of the study for which scapular kinematics are being determined and decide the optimal arm elevation position with which to calibrate the anatomical landmarks.

In order for any measurement technique to be considered a viable tool it is important to establish its reliability. The data presented in the present paper have shown that the acromion marker cluster can be classified as having excellent to good between-day reliability for scapular upward rotation and posterior tilt respectively. These finding were observed when examining the entire kinematic waveform during the elevation and lowering phases, demonstrating that the acromion marker cluster is a reliable method of measurement during both phases of arm movement. In a previous studies, the repositioning of the acromion marker cluster had been shown to adversely affect reliability27,28, particularly the reliability of scapular posterior tilt when comparing different investigators.28 The results from the present study, however, demonstrate that posterior tilt was a reliable measurement between days. Differences in methodology between the study of van Andel (2008) and the present study which include the type of motion capture system (active marker vs. passive marker), and the design and attachment site of the acromion marker cluster may account for the differences observed. In addition, it is known that the positioning of the acromion marker cluster onto different areas of the acromion affects the accuracy of the measurement31. Although the present study demonstrated good between day reliability, care must be taken when attaching the acromion marker cluster to the participant to ensure valid and reliable results are obtained.

Although good and excellent reliability was observed for upward rotation and posterior tilt, internal rotation of the scapula demonstrated poor to fair reliability when examining the entire kinematic waveform. This is in agreement with previous studies that have also found lower CMC results for internal rotation (0.82) and greater error (4.3°) when compared to upward rotation and posterior tilt (CMC = 0.94 and 0.85, error = 3.3° and 3.4° respectively)39,40. Internal rotation is, therefore, the least reliable of the scapular rotations. The reason why internal rotation has poorer reliability may be due to the lower range of motion (~5°) observed compared to other scapular rotations. The reported errors in the kinematic waveforms range from 3.9° to 7.3° meaning that the errors are in some cases larger than the motion taking place. In addition, within participant variability is inherently large3,18,41. The poor reliability may, therefore, not be as a result of the measurement technique, but rather the inherent individual variability coupled with a small range of motion. Caution should be taken when examining repeated measurements of internal scapular rotations.

The aim of measuring scapular kinematics is to quantify scapular dyskinesis, which is often observed clinically in patients with shoulder impingement1, and subsequently assess the changes in scapular kinematics following treatment interventions to reduce the effects of shoulder impingement30. The technique described in the present study has been used to demonstrate alterations in scapular kinematics in a group of individuals with shoulder impingement following a motor control retraining exercise30 and has been shown to be valid29 and reliable.

Subscription Required. Please recommend JoVE to your librarian.

Disclosures

None of the authors had any affiliation with any organization that could influence the outcome of this work.

Acknowledgments

This work lies within the multidisciplinary Southampton Musculoskeletal Research Unit (Southampton University Hospitals Trust/University of Southampton) and the Arthritis Research UK Centre for Sport, Exercise and Osteoarthritis. The authors wish to thank their funding sources; Arthritis Research UK for funding of laboratory equipment (Grant No: 18512) and Vicon Motion System, Oxford UK for providing funding for a PhD studentship (M.Warner). The authors also wish to thank the participants, and Kate Scott and Lindsay Pringle for their help with participant recruitment.

Materials

Name Company Catalog Number Comments
Passive marker capture system Vicon Motion Systems N/A
Nexus Vicon Motion Systems N/A Data capture software
Bodybuilder Vicon Motion Systems N/A Modeling software
14 mm retro reflective markers Vicon Motion Systems VACC-V162B
6.5 mm retro reflective markers Vicon Motion Systems VACC-V166
Calibration wand Vicon Motion Systems N/A
Plastic base N/A N/A Constructed 'in-house'
Matlab Mathworks N/A Numerical modelling software

DOWNLOAD MATERIALS LIST

References

  1. Kibler, W. B., et al. Clinical implications of scapular dyskinesis in shoulder injury: the 2013 consensus statement from the 'scapular summit'. British Journal of Sports Medicine. 47, 877-885 (2013).
  2. Luckasiewicz, A. C., McClure, P. W., Michener, L. A., Pratt, N., Sennett, B. Comparison of 3-dimensional scapular position and orientation between subjects with and without shoulder impingement. Journal of Orthopaedic & Sports Physical Therapy. 29, 574-586 (1999).
  3. Ludewig, P. M., Cook, T. M. Alterations in shoulder kinematics and associated muscle activity in people with symptoms of shoulder impingement. Physical Therapy. 80, 276-291 (2000).
  4. McClure, P. W., Bialker, J., Neff, N., Williams, G., Karduna, A. R. Shoulder function and 3-dimensional kinematics in people with shoulder impingement syndrome before and after a 6-week exercise program. Physical Therapy. 84, 832-848 (2004).
  5. Lin, J. J., et al. Functional activity characteristics of individuals with shoulder dysfunctions. Journal of Electromyography and Kinesiology. 15, 576-586 (2005).
  6. Tate, A. R., McClure, P. W., Kareha, S., Irwin, D., Barbe, M. F. A clinical method for identifying scapular dykinesis, Part 2: Validity. Journal of Athletic Training. 44, 165-173 (2009).
  7. Timmons, M. K., et al. Scapular kinematics and subacromial-impingement syndrome: a meta-analysis. Journal of Sports Rehabilitation. 21, 354-370 (2012).
  8. Endo, K. Y. K., Yasui, N. Influence of age on scapulo-thoracic orientation. Clinical Biomechanics. 16, 1009-1013 (2004).
  9. Lovern, B., Stroud, L. A., Evans, R. O., Evans, S. L., Holt, C. A. Dynamic tracking of the scapula using skin-mounted markers. Proceedings of the Institute of Mechanical Engineers. 223, 823-831 (2009).
  10. Inman, V. T., Sanders, J. B., Abbott, L. C. Observations on the function of the shoulder joint. Journal of Bone and Joint Surgery (Am). 26, 1-30 (1944).
  11. Saha, A. K. Mechanics of elevation of the glenohumeral joint. Acta Orthopaedica Scandanavia. 44, 668 (1973).
  12. Freedman, L., Munro, R. R. Abduction of the arm in the scapular plane: scapular and glenohumeral movements. A roentgenographic study. Journal of Bone and Joint Surgery (Am). 48, 1503-1510 (1966).
  13. Poppen, N. K., Walker, P. S. Normal and abnormal motion of the shoulder. Journal of Bone and Joint Surgery (Am). 58, 195-201 (1976).
  14. Graichen, H., et al. Magnetic resonance-based motion analysis of the shoulder during elevation). Clinical Orthopedic Related Research. 370, 154-163 (2000).
  15. Youdas, J. W., Carey, J. R., Garrett, T. R., Suman, V. J. Reliability of goniometric measurements of active arm elevation in the scapula plane obtained in a clinical setting. Arch. Phys. Med. Rehabil. 75, 1137-1144 (1994).
  16. Doody, S. G., Freedman, L., Waterland, J. C. Shoudler movement during abduction in the scapula plane. Arch. Phys. Med. Rehabil. 51, 595-604 (1970).
  17. Karduna, A. R., McClure, P. W., Michener, L. A., Sennett, B. Dynamic measurements of three-dimensional scapular kinematics: a validation study. Journal of Biomechanical Engineering. 123, 184-191 (2001).
  18. McClure, P. W., Michener, L. A., Sennett, B., Karduna, A. R. Direct 3-dimensional measurement of scapular kinematics during dynamic movements in vivo. Journal of Shoulder and Elbow Surgery. 10, 269-277 (2001).
  19. Bourne, D. A., Choo, A. M. T., Regan, W. D., MacIntyre, D. L., Oxland, T. R. Three-dimensional rotation of the scapula during functional movements: an in vivo study in healthy volunteers. Journal of Shoulder and Elbow Surgery. 16, 150-162 (2007).
  20. Braman, J. P., Engel, S. C., LaPrade, R. F., Ludewig, P. M. In vivo assessment of scapulohumeral rhythm during unconstrained overhead reaching in asymptomatic subjects. Journal of Shoulder and Elbow Surgery. 16, 960-967 (2009).
  21. Ludewig, P. M., Hassett, D. R., LaPrade, R. F., Camargo, J. A., Braman, J. P. Comparison of scapular local coordinate systems. Clinical Biomechanics. 25, 415-421 (2010).
  22. Ludewig, P. M., et al. Motion of the shoulder complex during multiplanar humeral elevation. The Journal of Bone and Joint Surgery. 91, 378-389 (2009).
  23. Johnson, G. R., Stuart, P. R., Mitchell, S. A method for the measurement of three-dimensional scapular movement. Clinical Biomechanics. 8, 269-274 (1993).
  24. Helm, F. C., Pronk, G. M. Three-dimensional recording and description of motions of the shoulder mechanism. Journal of Biomechanical Engineering. 117, 27-40 (1995).
  25. McQuade, K. J., Smidt, G. L. Dynamic Scapulohumeral rhythm: The effects of external resistance during elevation of the arm in the scapular plane. Journal of Orthopaedic & Sports Physical Therapy. 27, 9 (1998).
  26. Matsui, K., Shimada, K., Andrew, P. D. Deviation of skin marker from bone target during movement of the scapula. Journal of Orthopaedic Science. 11, 180-184 (2006).
  27. Meskers, C. G. M., Jvan de Sande, M. A., de Groot, J. H. Comparison between tripod and skin-fixed recording of scapular motion. J. Biomech. 40, 941-948 (2007).
  28. Andel, C. J., van Hutten, K., Eversdijk, M., Veeger, D. J., Harlaar, J. Recording scapular motion using an acromion marker cluster. Gait and Posture. 29, 123-128 (2009).
  29. Warner, M. B., Chappell, P. H., Stokes, M. J. Measuring scapular kinematics during arm lowering using the acromion marker cluster. Hum. Mov. Sci. 31, 386-396 (2012).
  30. Worsley, P., et al. Motor control retraining exercises for shoulder impingement: effects on function, muscle activation, and biomechanics in young adults. Journal of Shoulder and Elbow Surgery. 22, e11-e19 (2013).
  31. Shaheen, A. F., Alexander, C. M., Bull, A. M. J. Effects of attachment position and shoulder orientation during calibration on the accuracy of the acromial tracker. J. Biomech. 44, 1410-1413 (2011).
  32. Prinold, J. A. I., Shaheen, A. F., Bull, A. M. J. Skin-fixed scapula trackers: A comparison of two dynamic methods across a range of calibration positions. J. Biomech. 44, 2004-2007 (2011).
  33. Wu, G., et al. ISB recommendation on definitions of joint coordinate systems of the various joints for the reporting of human joint motion - Part II: shoulder, elbow, wrist and hand. J. Biomech. 38, 981-992 (2005).
  34. Karduna, A. R., McClure, P. W., Michener, L. A. Scapular kinematics: effects of altering the Euler angle sequence of rotations. J. Biomech. 33, 1063-1068 (2000).
  35. Veeger, H. E. J. The position of the rotation center of the glenohumeral joint. J. Biomech. 33, 1711-1715 (2000).
  36. Doorenbosch, C. A. M., Harlaar, J., Veeger, H. E. J. The globe system: an unambiguous description of shoulder positions in daily life movements. J. Rehabil. Res. Dev. 40, 147-156 (2003).
  37. Kadaba, M. P., et al. Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait. Journal of Orthopaedic Research. 7, 849-860 (1989).
  38. Schwartz, M. H., Trost, J. P., Wervey, R. A. Measurement and management of errors in quantitative gait data. Gait and Posture. 20, 196-203 (2004).
  39. Jaspers, E., et al. The reliability of upper limb kinematics in children with hemiplegic cerebral palsy. Gait and Posture. 33, 568-575 (2011).
  40. Thigpen, C. A., Gross, M. T., Karas, S. G., Garrett, W. E., Yu, B. The repeatability of scapular rotations across three planes of humeral elevation. Research in Sports Medicine. 13, 181-198 (2005).
  41. Groot, J. H. The variability of shoulder motions recorded by means of palpation. Clinical Biomechanics. 12, 461-472 (1997).

Tags

Scapular Kinematics Acromion Marker Cluster Skin Movement Artifact Passive Marker Motion Capture Arm Elevation Reliability Upward Rotation Posterior Tilt Internal Rotation
Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
Play Video
PDF DOI DOWNLOAD MATERIALS LIST

Cite this Article

Warner, M. B., Chappell, P. H.,More

Warner, M. B., Chappell, P. H., Stokes, M. J. Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact. J. Vis. Exp. (96), e51717, doi:10.3791/51717 (2015).

Less
Copy Citation Download Citation Reprints and Permissions
View Video

PLAYLIST

  • Research • Medicine
    Estimation of Urinary Nanocrystals in Humans using Calcium Fluorophore Labeling and Nanoparticle Tracking Analysis
  • Research • Medicine
    Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training
  • Research • Medicine
    Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
  • Research • Medicine
    Digital Handwriting Analysis of Characters in Chinese Patients with Mild Cognitive Impairment
  • Research • Medicine
    Segmentation and Linear Measurement for Body Composition Analysis using Slice-O-Matic and Horos
  • Research • Medicine
    Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
  • Research • Medicine
    Real-Time Magnetic Resonance Guided Focused Ultrasound for Painful Bone Metastases
  • Research • Medicine
    Isolation of Viable Adipocytes and Stromal Vascular Fraction from Human Visceral Adipose Tissue Suitable for RNA Analysis and Macrophage Phenotyping
  • Research • Medicine
    Obtaining Quality Extended Field-of-View Ultrasound Images of Skeletal Muscle to Measure Muscle Fascicle Length
  • Research • Medicine
    Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
  • Research • Medicine
    Electroretinogram Recording for Infants and Children under Anesthesia to Achieve Optimal Dark Adaptation and International Standards
  • Research • Medicine
    Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
  • Research • Medicine
    Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
  • Research • Medicine
    Simultaneous Laryngopharyngeal and Conventional Esophageal pH Monitoring
  • Research • Medicine
    Real-Time Monitoring of Neurocritical Patients with Diffuse Optical Spectroscopies
  • Research • Neuroscience
    Evaluating Postural Control and Lower-extremity Muscle Activation in Individuals with Chronic Ankle Instability
  • Research • Medicine
    Assessment of Dependence in Activities of Daily Living Among Older Patients in an Acute Care Unit
  • Research • Medicine
    Validated LC-MS/MS Panel for Quantifying 11 Drug-Resistant TB Medications in Small Hair Samples
  • Research • Medicine
    International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
  • Research • Biology
    A Finite Element Approach for Locating the Center of Resistance of Maxillary Teeth
  • Research • Medicine
    Lower Limb Biomechanical Analysis of Healthy Participants
  • Research • Neuroscience
    Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
  • Research • Medicine
    Oral Health Assessment by Lay Personnel for Older Adults
  • Research • Medicine
    Determining and Controlling External Power Output During Regular Handrim Wheelchair Propulsion
  • Research • Medicine
    A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
  • Research • Medicine
    Measurement of Carotenoids in Perifovea using the Macular Pigment Reflectometer
  • Research • Medicine
    Assessment of Static Graviceptive Perception in the Roll-Plane using the Subjective Visual Vertical Paradigm
  • Research • Medicine
    Learning Modern Laryngeal Surgery in a Dissection Laboratory
  • Research • Medicine
    DIPLOMA Approach for Standardized Pathology Assessment of Distal Pancreatectomy Specimens
  • Research • Medicine
    A Computerized Functional Skills Assessment and Training Program Targeting Technology Based Everyday Functional Skills
  • Research • Medicine
    Imaging Features of Systemic Sclerosis-Associated Interstitial Lung Disease
  • Research • Medicine
    Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
  • Research • Medicine
    Ultrasonographic Assessment During Cardiopulmonary Resuscitation
  • Research • Medicine
    Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
  • Research • Medicine
    Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
  • Research • Medicine
    Traditional Trail Making Test Modified into Brand-new Assessment Tools: Digital and Walking Trail Making Test
  • Research • Medicine
    Use of Magnetic Resonance Imaging and Biopsy Data to Guide Sampling Procedures for Prostate Cancer Biobanking
  • Research • Medicine
    A Fluorescence-based Assay for Characterization and Quantification of Lipid Droplet Formation in Human Intestinal Organoids
  • Research • Medicine
    A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
  • Research • Medicine
    Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
  • Research • Neuroscience
    Portable Thermographic Screening for Detection of Acute Wallenberg's Syndrome
  • Research • Medicine
    Use of MRI-ultrasound Fusion to Achieve Targeted Prostate Biopsy
  • Research • Medicine
    Testing of all Six Semicircular Canals with Video Head Impulse Test Systems
  • Research • Medicine
    Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
  • Research • Neuroscience
    Bilateral Assessment of the Corticospinal Pathways of the Ankle Muscles Using Navigated Transcranial Magnetic Stimulation
  • Research • Medicine
    Targeting Gray Rami Communicantes in Selective Chemical Lumbar Sympathectomy
  • Research • Medicine
    Multi-Modal Home Sleep Monitoring in Older Adults
  • Research • Medicine
    Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
  • Research • Medicine
    Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
  • Research • Medicine
    Measurements of Motor Function and Other Clinical Outcome Parameters in Ambulant Children with Duchenne Muscular Dystrophy
  • Research • Medicine
    Assessment of the Efficacy of An Osteopathic Treatment in Infants with Biomechanical Impairments to Suckling
  • Research • Medicine
    Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
  • Research • Medicine
    Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
  • Research • Medicine
    Generation of Human 3D Lung Tissue Cultures (3D-LTCs) for Disease Modeling
  • Research • Medicine
    Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
  • Research • Medicine
    Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
  • Research • Medicine
    Two-Dimensional X-Ray Angiography to Examine Fine Vascular Structure Using a Silicone Rubber Injection Compound
  • Research • Medicine
    Preparation, Procedures and Evaluation of Platelet-Rich Plasma Injection in the Treatment of Knee Osteoarthritis
  • Research • Medicine
    Cardiac Magnetic Resonance Imaging at 7 Tesla
  • Research • Medicine
    Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury
  • Research • Medicine
    Handheld Metal Detector Screening for Metallic Foreign Body Ingestion in Children
  • Research • Medicine
    Conducting Maximal and Submaximal Endurance Exercise Testing to Measure Physiological and Biological Responses to Acute Exercise in Humans
  • Research • Medicine
    A Metadata Extraction Approach for Clinical Case Reports to Enable Advanced Understanding of Biomedical Concepts
  • Research • Medicine
    Autonomic Function Following Concussion in Youth Athletes: An Exploration of Heart Rate Variability Using 24-hour Recording Methodology
  • Research • Medicine
    Hydra, a Computer-Based Platform for Aiding Clinicians in Cardiovascular Analysis and Diagnosis
  • Research • Medicine
    Objective Nociceptive Assessment in Ventilated ICU Patients: A Feasibility Study Using Pupillometry and the Nociceptive Flexion Reflex
  • Research • Medicine
    'Boden Food Plate': Novel Interactive Web-based Method for the Assessment of Dietary Intake
  • Research • Medicine
    Anogenital Distance and Perineal Measurements of the Pelvic Organ Prolapse (POP) Quantification System
  • Research • Medicine
    Bedside Ultrasound for Guiding Fluid Removal in Patients with Pulmonary Edema: The Reverse-FALLS Protocol
  • Research • Medicine
    Muscle Imbalances: Testing and Training Functional Eccentric Hamstring Strength in Athletic Populations
  • Research • Medicine
    Isolation of Primary Human Decidual Cells from the Fetal Membranes of Term Placentae
  • Research • Medicine
    Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
  • Research • Medicine
    Collecting Hair Samples for Hair Cortisol Analysis in African Americans
  • Research • Medicine
    In Vivo Morphometric Analysis of Human Cranial Nerves Using Magnetic Resonance Imaging in Menière's Disease Ears and Normal Hearing Ears
  • Research • Medicine
    Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
  • Research • Medicine
    Standardized Measurement of Nasal Membrane Transepithelial Potential Difference (NPD)
  • Research • Medicine
    Taste Exam: A Brief and Validated Test
  • Research • Medicine
    Absorption of Nasal and Bronchial Fluids: Precision Sampling of the Human Respiratory Mucosa and Laboratory Processing of Samples
  • Research • Medicine
    Methodology for Sputum Induction and Laboratory Processing
  • Research • Medicine
    Electrophysiological Measurement of Noxious-evoked Brain Activity in Neonates Using a Flat-tip Probe Coupled to Electroencephalography
  • Research • Medicine
    A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
  • Research • Medicine
    Oral Biofilm Sampling for Microbiome Analysis in Healthy Children
  • Research • Medicine
    Using Retinal Imaging to Study Dementia
  • Research • Medicine
    Application of an Amplitude-integrated EEG Monitor (Cerebral Function Monitor) to Neonates
  • Research • Medicine
    3D Ultrasound Imaging: Fast and Cost-effective Morphometry of Musculoskeletal Tissue
  • Research • Medicine
    The 4-vessel Sampling Approach to Integrative Studies of Human Placental Physiology In Vivo
  • Research • Medicine
    A Component-resolved Diagnostic Approach for a Study on Grass Pollen Allergens in Chinese Southerners with Allergic Rhinitis and/or Asthma
  • Research • Medicine
    A Novel Method: Super-selective Adrenal Venous Sampling
  • Research • Medicine
    A Method for Quantifying Upper Limb Performance in Daily Life Using Accelerometers
  • Research • Medicine
    Non-invasive Assessments of Subjective and Objective Recovery Characteristics Following an Exhaustive Jump Protocol
  • Research • Medicine
    Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
  • Research • Medicine
    Phosphorus-31 Magnetic Resonance Spectroscopy: A Tool for Measuring In Vivo Mitochondrial Oxidative Phosphorylation Capacity in Human Skeletal Muscle
  • Research • Medicine
    Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
  • Research • Medicine
    Assessment of Child Anthropometry in a Large Epidemiologic Study
  • Research • Medicine
    Video Movement Analysis Using Smartphones (ViMAS): A Pilot Study
  • Research • Medicine
    Network Analysis of Foramen Ovale Electrode Recordings in Drug-resistant Temporal Lobe Epilepsy Patients
  • Research • Medicine
    A Model to Simulate Clinically Relevant Hypoxia in Humans
  • Research • Medicine
    Interictal High Frequency Oscillations Detected with Simultaneous Magnetoencephalography and Electroencephalography as Biomarker of Pediatric Epilepsy
  • Research • Medicine
    Induction and Assessment of Exertional Skeletal Muscle Damage in Humans
  • Research • Medicine
    A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
  • Research • Medicine
    Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
  • Research • Medicine
    Integrated Compensatory Responses in a Human Model of Hemorrhage
  • Research • Medicine
    Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
  • Research • Medicine
    Impression Cytology of the Lid Wiper Area
  • Research • Behavior
    A Protocol of Manual Tests to Measure Sensation and Pain in Humans
  • Research • Medicine
    Unbiased Deep Sequencing of RNA Viruses from Clinical Samples
  • Research • Medicine
    A Choroid Plexus Epithelial Cell-based Model of the Human Blood-Cerebrospinal Fluid Barrier to Study Bacterial Infection from the Basolateral Side
  • Research • Medicine
    Isolation and Profiling of MicroRNA-containing Exosomes from Human Bile
  • Research • Medicine
    Generation of Microtumors Using 3D Human Biogel Culture System and Patient-derived Glioblastoma Cells for Kinomic Profiling and Drug Response Testing
  • Research • Medicine
    Ultrasound Assessment of Endothelial Function: A Technical Guideline of the Flow-mediated Dilation Test
  • Research • Medicine
    Using a Laminating Technique to Perform Confocal Microscopy of the Human Sclera
  • Research • Medicine
    Intravenous Endotoxin Challenge in Healthy Humans: An Experimental Platform to Investigate and Modulate Systemic Inflammation
  • Research • Medicine
    Modeling and Simulations of Olfactory Drug Delivery with Passive and Active Controls of Nasally Inhaled Pharmaceutical Aerosols
  • Research • Medicine
    Exosomal miRNA Analysis in Non-small Cell Lung Cancer (NSCLC) Patients' Plasma Through qPCR: A Feasible Liquid Biopsy Tool
  • Research • Medicine
    A Multimodal Imaging- and Stimulation-based Method of Evaluating Connectivity-related Brain Excitability in Patients with Epilepsy
  • Research • Medicine
    Measuring Cardiac Autonomic Nervous System (ANS) Activity in Toddlers - Resting and Developmental Challenges
  • Research • Medicine
    Using Saccadometry with Deep Brain Stimulation to Study Normal and Pathological Brain Function
  • Research • Medicine
    Quantitative Fundus Autofluorescence for the Evaluation of Retinal Diseases
  • Research • Medicine
    Diagnosis of Musculus Gastrocnemius Tightness - Key Factors for the Clinical Examination
  • Research • Medicine
    Stereo-Electro-Encephalo-Graphy (SEEG) With Robotic Assistance in the Presurgical Evaluation of Medical Refractory Epilepsy: A Technical Note
  • Research • Medicine
    Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
  • Research • Medicine
    Transcutaneous Microcirculatory Imaging in Preterm Neonates
  • Research • Medicine
    Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
  • Research • Medicine
    Design, Fabrication, and Administration of the Hand Active Sensation Test (HASTe)
  • Research • Medicine
    MRI-guided dmPFC-rTMS as a Treatment for Treatment-resistant Major Depressive Disorder
  • Research • Medicine
    Functional Human Liver Preservation and Recovery by Means of Subnormothermic Machine Perfusion
  • Research • Medicine
    A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
  • Research • Medicine
    Determining The Electromyographic Fatigue Threshold Following a Single Visit Exercise Test
  • Research • Medicine
    Use of Electromagnetic Navigational Transthoracic Needle Aspiration (E-TTNA) for Sampling of Lung Nodules
  • Research • Medicine
    Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
  • Research • Medicine
    In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
  • Research • Medicine
    Establishment of Human Epithelial Enteroids and Colonoids from Whole Tissue and Biopsy
  • Research • Medicine
    Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
  • Research • Medicine
    Preparation and Respirometric Assessment of Mitochondria Isolated from Skeletal Muscle Tissue Obtained by Percutaneous Needle Biopsy
  • Research • Medicine
    A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
  • Research • Medicine
    Isolation and Immortalization of Patient-derived Cell Lines from Muscle Biopsy for Disease Modeling
  • Research • Medicine
    State of the Art Cranial Ultrasound Imaging in Neonates
  • Research • Medicine
    Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
  • Research • Medicine
    The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
  • Research • Medicine
    Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
  • Research • Medicine
    Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
  • Research • Medicine
    A Neuroscientific Approach to the Examination of Concussions in Student-Athletes
  • Research • Medicine
    DTI of the Visual Pathway - White Matter Tracts and Cerebral Lesions
  • Research • Medicine
    Collection, Isolation, and Flow Cytometric Analysis of Human Endocervical Samples
  • Research • Medicine
    Fundus Photography as a Convenient Tool to Study Microvascular Responses to Cardiovascular Disease Risk Factors in Epidemiological Studies
  • Research • Medicine
    A Multi-Modal Approach to Assessing Recovery in Youth Athletes Following Concussion
  • Research • Medicine
    Clinical Assessment of Spatiotemporal Gait Parameters in Patients and Older Adults
  • Research • Medicine
    Multi-electrode Array Recordings of Human Epileptic Postoperative Cortical Tissue
  • Research • Medicine
    Collection and Extraction of Saliva DNA for Next Generation Sequencing
  • Research • Medicine
    Fast and Accurate Exhaled Breath Ammonia Measurement
  • Research • Medicine
    Developing Neuroimaging Phenotypes of the Default Mode Network in PTSD: Integrating the Resting State, Working Memory, and Structural Connectivity
  • Research • Medicine
    Two Methods for Establishing Primary Human Endometrial Stromal Cells from Hysterectomy Specimens
  • Research • Medicine
    Assessment of Vascular Function in Patients With Chronic Kidney Disease
  • Research • Medicine
    Coordinate Mapping of Hyolaryngeal Mechanics in Swallowing
  • Research • Medicine
    Network Analysis of the Default Mode Network Using Functional Connectivity MRI in Temporal Lobe Epilepsy
  • Research • Medicine
    EEG Mu Rhythm in Typical and Atypical Development
  • Research • Medicine
    The Multiple Sclerosis Performance Test (MSPT): An iPad-Based Disability Assessment Tool
  • Research • Medicine
    Isolation and Functional Characterization of Human Ventricular Cardiomyocytes from Fresh Surgical Samples
  • Research • Medicine
    Dynamic Visual Tests to Identify and Quantify Visual Damage and Repair Following Demyelination in Optic Neuritis Patients
  • Research • Medicine
    Primary Culture of Human Vestibular Schwannomas
  • Research • Medicine
    Utility of Dissociated Intrinsic Hand Muscle Atrophy in the Diagnosis of Amyotrophic Lateral Sclerosis
  • Research • Medicine
    Lesion Explorer: A Video-guided, Standardized Protocol for Accurate and Reliable MRI-derived Volumetrics in Alzheimer's Disease and Normal Elderly
  • Research • Medicine
    Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
  • Research • Medicine
    Isolation, Culture, and Imaging of Human Fetal Pancreatic Cell Clusters
  • Research • Medicine
    3D-Neuronavigation In Vivo Through a Patient's Brain During a Spontaneous Migraine Headache
  • Research • Medicine
    A Novel Application of Musculoskeletal Ultrasound Imaging
  • Research • Medicine
    Computerized Dynamic Posturography for Postural Control Assessment in Patients with Intermittent Claudication
  • Research • Medicine
    Collecting Saliva and Measuring Salivary Cortisol and Alpha-amylase in Frail Community Residing Older Adults via Family Caregivers
  • Research • Medicine
    Diffusion Tensor Magnetic Resonance Imaging in the Analysis of Neurodegenerative Diseases
  • Research • Medicine
    Transcriptomic Analysis of Human Retinal Surgical Specimens Using jouRNAl
  • Research • Medicine
    Improved Protocol For Laser Microdissection Of Human Pancreatic Islets From Surgical Specimens
  • Research • Medicine
    Evaluation of Respiratory Muscle Activation Using Respiratory Motor Control Assessment (RMCA) in Individuals with Chronic Spinal Cord Injury
  • Research • Medicine
    Minimal Erythema Dose (MED) Testing
  • Research • Medicine
    Measuring Cardiac Autonomic Nervous System (ANS) Activity in Children
  • Research • Medicine
    Collecting And Measuring Wound Exudate Biochemical Mediators In Surgical Wounds
  • Research • Medicine
    A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
  • Research • Medicine
    Using a Chemical Biopsy for Graft Quality Assessment
  • Research • Medicine
    Characterizing Exon Skipping Efficiency in DMD Patient Samples in Clinical Trials of Antisense Oligonucleotides
  • Research • Medicine
    In Vitro Assessment of Cardiac Function Using Skinned Cardiomyocytes
  • Research • Medicine
    Normothermic Ex Situ Heart Perfusion in Working Mode: Assessment of Cardiac Function and Metabolism
  • Research • Medicine
    Evaluation of Vascular Control Mechanisms Utilizing Video Microscopy of Isolated Resistance Arteries of Rats
  • Research • Medicine
    Bronchoalveolar Lavage (BAL) for Research; Obtaining Adequate Sample Yield
  • Research • Medicine
    Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
  • Research • Medicine
    Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
  • Research • Medicine
    Driving Simulation in the Clinic: Testing Visual Exploratory Behavior in Daily Life Activities in Patients with Visual Field Defects
  • Research • Medicine
    Isolation, Characterization and Comparative Differentiation of Human Dental Pulp Stem Cells Derived from Permanent Teeth by Using Two Different Methods
  • Research • Medicine
    Portable Intermodal Preferential Looking (IPL): Investigating Language Comprehension in Typically Developing Toddlers and Young Children with Autism
  • Research • Medicine
    Intraoperative Detection of Subtle Endometriosis: A Novel Paradigm for Detection and Treatment of Pelvic Pain Associated with the Loss of Peritoneal Integrity
  • Research • Medicine
    The Use of Primary Human Fibroblasts for Monitoring Mitochondrial Phenotypes in the Field of Parkinson's Disease
  • Research • Medicine
    Collection Protocol for Human Pancreas
  • Research • Medicine
    The α-test: Rapid Cell-free CD4 Enumeration Using Whole Saliva
  • Research • Medicine
    The Measurement and Treatment of Suppression in Amblyopia
  • Research • Medicine
    Corneal Donor Tissue Preparation for Endothelial Keratoplasty
  • Research • Medicine
    Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)
  • Research • Medicine
    Eye Tracking Young Children with Autism
  • Research • Medicine
    Doppler Optical Coherence Tomography of Retinal Circulation
  • Research • Medicine
    Utilizing Transcranial Magnetic Stimulation to Study the Human Neuromuscular System
  • Research • Medicine
    Detection and Genogrouping of Noroviruses from Children's Stools By Taqman One-step RT-PCR
  • Research • Medicine
    Method to Measure Tone of Axial and Proximal Muscle
  • Research • Medicine
    The Trier Social Stress Test Protocol for Inducing Psychological Stress
  • Research • Medicine
    Probing the Brain in Autism Using fMRI and Diffusion Tensor Imaging
  • Research • Medicine
    Multifocal Electroretinograms
  • Research • Medicine
    Isolation of Human Islets from Partially Pancreatectomized Patients
  • Research • Medicine
    Examining the Characteristics of Episodic Memory using Event-related Potentials in Patients with Alzheimer's Disease
  • Research • Medicine
    Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
  • Research • Medicine
    Manual Muscle Testing: A Method of Measuring Extremity Muscle Strength Applied to Critically Ill Patients
  • Research • Medicine
    Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
  • Research • Medicine
    A Protocol for Comprehensive Assessment of Bulbar Dysfunction in Amyotrophic Lateral Sclerosis (ALS)
  • Research • Medicine
    An Investigation of the Effects of Sports-related Concussion in Youth Using Functional Magnetic Resonance Imaging and the Head Impact Telemetry System
  • Research • Medicine
    Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies
  • Research • Medicine
    Methods to Quantify Pharmacologically Induced Alterations in Motor Function in Human Incomplete SCI
  • Research • Medicine
    Multispectral Real-time Fluorescence Imaging for Intraoperative Detection of the Sentinel Lymph Node in Gynecologic Oncology
  • Research • Medicine
    Technique to Collect Fungiform (Taste) Papillae from Human Tongue
  • Research • Medicine
    Assessing Endothelial Vasodilator Function with the Endo-PAT 2000
  • Research • Medicine
    Making Sense of Listening: The IMAP Test Battery
  • Research • Medicine
    An Experimental Paradigm for the Prediction of Post-Operative Pain (PPOP)
  • Research • Biology
    Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
  • Research • Biology
    Demonstration of Cutaneous Allodynia in Association with Chronic Pelvic Pain
  • Get cutting-edge science videos from JoVE sent straight to your inbox every month.

    Waiting X
    Simple Hit Counter