Cerrahi yerleştirme ve kateter ve elektrotlar, tekrarlayan kan örneklemesi, madde enjeksiyonu, biyoelektrik aktivitesinin kaydedilmesi bakım ve in vivo görüntüleme izni nedeniyle kronik instrumented olmayan anestezi fetal koyun modeli, sağlık ve hastalık insan fetal gelişimini incelemek için kullanılır. Biz bu modeli kurmak için gerekli prosedürler açıklanmaktadır.
The chronically instrumented pregnant sheep has been used as a model of human fetal development and responses to pathophysiologic stimuli such as endotoxins, bacteria, umbilical cord occlusions, hypoxia and various pharmacological treatments. The life-saving clinical practices of glucocorticoid treatment in fetuses at risk of premature birth and the therapeutic hypothermia have been developed in this model. This is due to the unique amenability of the non-anesthetized fetal sheep to the surgical placement and maintenance of catheters and electrodes, allowing repetitive blood sampling, substance injection, recording of bioelectrical activity, application of electric stimulation and in vivo organ imaging. Here we describe the surgical instrumentation procedure required to achieve a stable chronically instrumented non-anesthetized fetal sheep model including characterization of the post-operative recovery from blood gas, metabolic and inflammation standpoints.
Hayvan modellerinde çeşitli laboratuar kemirgenler, insan olmayan primatlar ve yerli geviş getirenler da dahil olmak üzere normal ve tehlikeye gebeliklerin hem de çalışma için mevcuttur. 1,2,3,4,5 Kronik olarak gebe koyunun 50 yıl olarak için yaygın olarak kullanılmaktadır lipopolisakkaritler gibi patofizyolojik uyaranlar (LPS) insan fetal gelişim ve yanıtları bir modeldir. 6-10 LPS maruziyeti aşağıdaki lezyonlar nedeniyle her iki türün de benzer bir olgunlaşma profiline olan periventriküler lökomalazi ile erken doğan bebeklerde görülen tam olarak ne taklit. 11, 12
Diğer gebelik komplikasyonları ayrıca doğum öncesi glukokortikoidler akciğer gelişimini 13-15 ve fetus 16,17 üzerinde intrauterin büyüme geriliği (IUGR) etkisinin anlaşılması teşvik olduğunu keşif gibi büyük detaylı incelenmiştir.
Fetal koyun modelinde geniş kullanımı uniq nedeniyletekrarlayan kan örneklemesi, biyoelektrik aktivitesinin kaydedilmesi, elektrik stimülasyonu ve in vivo beyin görüntüleme uygulaması sağlayan cerrahi yerleştirme ve kateter ve elektrotların bakımı olmayan anestezi fetal koyun vi amenability. daha az sıklıkla kullanılan rağmen 18 Telemetri de mümkündür henüz daha sofistike nedeniyle ilk ve bakım maliyeti yanı sıra kurmak. 19
Enstrümantasyon birçok varyasyonu ilgi önlemlere bağlı olarak mümkün olduğu Dahası, fetal koyun modeli çok yönlüdür. Örneğin, hafta gün içinde kaydetmek mümkündür böyle fetal solunum hareketlerinin, elektriksel beyin aktivitesi, kardiyovasküler tepkiler, elektrokardiyogram, organların bir dizi bölgesel kan akımı akış sondaları veya mikroküreler, vb Teşekkür kullanarak gerçek zamanlı olarak çok değişkenli sinyaller Bu çok yönlülük, çalışmaların geniş bir yelpazede Cardi geliştirilmesi dahil olmak üzere yapılmıştırovascular sistemi 20,21, hipotalamus-hipofiz-adrenal (HPA) eksen 22, özellikle de 24 yılında beyin gelişimi 23 ve uyku durumları geliştirme, hipoksi etkisi / asfiksi 25, terapötik hipotermi 26, inflamasyon 6-11, hem 27 kombinasyonu, glukokortikoidler 28,29 anti-depresanlar 30, bronko-pulmoner displazi (BPD) 31,32, önceki ve doğum sırasında adı ancak fetal programlama 33,34,35,36,37,38,39 veya yeni fetal izleme yöntemlerinin geliştirilmesi Soruşturmanın birkaç alanları. 40,41,42,43
Sunulan yöntemin genel amacı bu çok yönlü modelin temel uygulanmasını göstermektir. Bu hücresel bütünleştirici, organ ve moleküler düzeylerde fetal fizyolojisi ve patofizyolojisi okuyan akut ve kronik deneysel protokollerin geniş bir yelpazede kurulması sağlar.
Kronik aletli olmayan anestezi fetal koyun: anestezi ve cerrahi girişimler, fetal fizyolojisi ve patofizyolojisi çalışmak için bir hayvan modeli kurulması için gerekli olduğunu sunulmuştur.
Protokolü içinde dört kritik adımlar vurgulanmalıdır. Birincisi, anne kanadını yoluyla kateterler ve elektrotlar geçen: Bu herhangi bir iç organ yaralanmaları önlemek için bir defada yapılır önemlidir. İkincisi, fetüsü exteriorizing önce uterotomy işletim sitesini güvence: B…
The authors have nothing to disclose.
authors gratefully acknowledge funding support from the Molly Towell Perinatal Research Foundation, Canadian Institutes of Health Research (CIHR), and Fonds de Recherche du Québec – Santé (FRQS) (to MGF) and CIHR-Quebec Training Network in Perinatal Research (QTNPR) (to LDD).
The authors wish to thank Esther Simard, Marco Bosa, Carl Bernard and Carmen Movila for technical assistance.
ACE Light source | Schott-Fostec | A20500 | |
Dissecting scissors | Fine Science Tools | 14060 – 11 | |
Angled dissecting scissors | Fine Science Tools | 15006 – 09 | |
Scalpel handle | Fine Science Tools | 10003 – 12 | alternating dissecting tool |
Curved scalpel blades #12 | Fine Science Tools | 10012 – 00 | alternating dissecting tool |
Bone scissors | Fine Science Tools | 16044 – 10 | |
S & T suture tying forceps | Fine Science Tools | 00272 – 13 | |
Dumont SS forceps – angled | Fine Science Tools | 11203 – 25 | |
Braided silk suture size 6-0 | Teleflex Medical | 07 – 30 – 10 | |
Medical Tape | transpore | 3M | |
Ketamine hydrochloride 100 mg/ml | Hospira | NDC 0409 – 2051 – 05 | Final Does is 80 mg/kg |
Tranqui Ved Injection (xylazine 100 mg/ml) | Vecdo | NDC 50989 – 234 – 11 | Final Does is 10 mg/kg |
Reactive orange 14 | Sigma – Aldrich | R – 8254 | |
Ringers Solution Components | Solution is gas equilibrated with 95% O2 and 5% Co2, final pH 7.4 | ||
Sodium chloride | Sigma – Aldrich | S7653 | Final Concentration: 118 mM |
Potassium chloride | Fisher Scientific | P217 – 3 | Final Concentration: 4.7 mM |
Calcium chloride dihydrate | Fisher Scientific | C79 – 500 | Final Concentration: 2.5 mM |
Potassium phosphate monobasic | Fisher Scientific | P -285 | Final Concentration: 1.2 mM |
Magnesium sulfate | J.T. Baker | Jan-00 | Final Concentration: 0.57 mM |
4-(2-Hydroxyethyl)piperazine-1-ethanesulfonic acid (HEPES) | Fisher Scientific | BP 310 – 500 | Final Concentration: 5.95 g/L |
Glucose | Sigma – Aldrich | G8270 | Final Concentration: 5.5 mM |
LifeWindow | Digicare Biomedical Technology | ||
CED bioamplifier and ADC units | Cambridge Electronic Design Limited, Unit 4, Science Park, Milton Road, Cambridge CB4 0FE ENGLAND. |
Bioamp: 1902; ADC: micro1401; Data acquisition software: Spike 2, V7.13 | |
Neurolog analog signal bioamplifier | Digitimer Ltd 37 Hydeway Welwyn Garden City Hertfordshire, AL7 3BE, England |
NL108A | |
ABL800Flex | Radiometer Canada; 200 Aberdeen Dr, London, ON N5V 4N2 | ||
Eppendorf 5804R | Eppendorf Canada; 2810 Argentia Road, #2 Mississauga, Ontario, L5N 8L2 |
||
Arrow Jugular Catheterization Set | Arrow International, Inc., 2400 Bernville Road, Reading, PA 19605 USA | ||
Atravet | 10 mg/mL | ||
Diazepam | 5mg/mL | ||
Ketamine | Ketalar | 100 mg/mL | |
Propofol | 10 mg/mL | ||
SurgiVeT | Endotracheal Tubes; Smiths Medical ASD, Inc. St. Paul, MN 55112, USA | ||
Cook Airway Exchange Catheter with RAPI-FIT Adapters | Cook Critical Care 750, Bloomington IN 47402-0489 USA | ||
Dispomed Ventilator | Dispomed Ltd., 745 Nazaire-Laurin, Joliette, Quebec J6E 0L6 | ||
BD Insyte-W | Becton Dickinson, Infusion Therapy Systems Inc., 9450 S State St, Sandy Utah 84070 USA | 22 to 20 G; 1 in [0.9 x 25 mm] to 1.16 in [1.1 x 30 mm] | |
Edwards Lifesciences Ref: PX272 Pressure monitoring kit with TruWave Disposable Pressure | |||
LifeWindow LW6000 | Digicare Biomedical Technology 107 Commerce Road, Boynton Beach, FL 33426-9365 USA | ||
Gaymar | |||
Babcock | |||
Polyvinyl catheters | SCI (Scientific Commodities Inc.) | 2 meters | |
2-0 Vicryl | |||
Castroviejo scissors | |||
electrocardiogram (ECG) | LIFYY, Metrofunk Kabel-Union, Berlin, Germany | four copper electrodes in single sheath, 2 meters | |
2-O Vicryl | |||
3-0 Vicryl | |||
PDS II USP | |||
Trimethoprim sulfadoxine | |||
Ampicillin | |||
Stopcock | Argon Medical, Cat 041220001A | Double 4-way Stopcock with male luer lock | |
Needles | Tyco Healthcare 8881202389 | Monoject aluminum hub blunt needles, 22Gx, 0.7mmx 38.1mm: for fetal arterial and venous catheters | |
Needles | Tyco Healthcare 8881202322 | Monoject aluminum hub blunt needles, 16Gx, 1.6mmx38.1mm: for amniotic catheters |