Summary

Karakterisering Far-infrarøde Laser Emissioner og måling af deres frekvenser

Published: December 18, 2015
doi:

Summary

We describe the generation of far-infrared radiation using an optically pumped molecular laser along with the measurement of their frequencies with heterodyne techniques. The experimental system and techniques are demonstrated using difluoromethane (CH2F2) as the laser medium whose results include three new laser emissions and eight measured laser frequencies.

Abstract

Generering og efterfølgende måling af langtrækkende infrarød stråling har fundet talrige anvendelser i høj opløsning spektroskopi, radio astronomi, og Terahertz billeddannelse. For omkring 45 år, har frembringelsen af ​​sammenhængende, langtrækkende infrarød stråling blevet opnået ved hjælp af optisk pumpet molekylær laser. Når langtrækkende infrarød laserstråling detekteres, er hyppigheden af ​​disse laseremissioner målt ved anvendelse af en tre-laser heterodyn teknik. Med denne teknik, den ukendte frekvens fra den optisk pumpede molekylær laser er blandet med den forskel frekvens mellem to stabiliserede, infrarøde referencefrekvenser. Disse referencefrekvenser genereres af uafhængige kuldioxidlasere, hver stabiliseres ved anvendelse af fluorescens-signal fra en ekstern, lavtryk referencecellen. Den resulterende slag mellem kendte og ukendte laserfrekvenser overvåges af en metal-isolator-metal punktkontakt diodedetektor hvis udgang er observeret på en spectrum analysator. Rytmen frekvens mellem disse laser emissioner måles efterfølgende og kombineret med de kendte referencepunkter frekvenser at ekstrapolere det ukendte langtrækkende infrarød laser frekvens. Det resulterende én-sigma fraktioneret usikkerhed for laser frekvenser målt med denne teknik er ± 5 dele i 10 7. Præcist bestemme hyppigheden af langtrækkende infrarød laser emissioner er kritisk, da de ofte bruges som reference for andre målinger, som i høj -Opløsning spektroskopiske undersøgelser af frie radikaler ved hjælp af laser magnetisk resonans. Som led i denne undersøgelse, difluormethan, CH2F 2, blev brugt som langtrækkende infrarød laser medium. I alt blev otte langtrækkende infrarød laser frekvenser målt for første gang med frekvenser, der spænder fra 0,359 til 1,273 THz. Tre af disse laser emissioner blev opdaget i løbet af denne undersøgelse, og indberettes med deres optimale driftstryk, polarisering med hensyn til CO 2 </sub> pumpe laser og styrke.

Introduction

Målingen af ​​langtrækkende infrarød laser frekvenser blev uropført af Hocker og medarbejdere i 1967. De målte frekvenserne for de 311 og 337 um emissioner fra direkte udledning hydrogencyanid laser ved at blande dem med høje ordens harmoniske af en mikrobølgeovn signal i en silicium diode 1. For at måle højere frekvenser, blev en kæde af lasere og harmoniske blandeanordninger anvendt til at generere harmoniske laser 2. Til sidst to stabiliserede kuldioxid (CO2) lasere blev udvalgt til at syntetisere den nødvendige forskel frekvenser 3,4. Dag, kan måles langtrækkende infrarød laser frekvenser op til 4 THz med denne teknik kun at bruge den første harmoniske af forskellen frekvens genereres af to stabiliserede CO 2 referencenumre lasere. Kan også måles højere frekvens laseremissioner bruge den anden harmoniske, såsom de 9 THz laseremissioner fra methanol isotopologues CHD 2 OH og CH3 </sub> 18 OH. 5,6 årenes løb har nøjagtig måling af laser frekvenser påvirket en række videnskabelige forsøg 7,8 og tilladt vedtagelsen af en ny definition af måleren af Generalkonferencen for Mål og Vægt i Paris i 1983. 9 11

Heterodyne teknikker, såsom de beskrevet, har været utroligt gavnligt i målingen af ​​langtrækkende infrarød laserfrekvenser genereret af optisk pumpede molekylære lasere. Siden opdagelsen af den optisk pumpede molekylær laser af Chang og broer 12, tusindvis af optisk pumpet langtrækkende infrarød laseremissioner er blevet genereret med en række laser medier. For eksempel, difluormethan (CH2 F 2) og dets isotopologues genererer over 250 laseremissioner når optisk pumpet af en CO 2-laser. Deres bølgelængder i området fra ca. 95,6 til 1714,1 pm 13. </sop> 15 Næsten 75% af disse laser emissioner har haft deres frekvenser målt mens flere er blevet spektroskopisk tildelt 16-18.

Disse lasere, og deres måles nøjagtigt frekvenser, har spillet en afgørende rolle i udvikling af høj opløsning spektroskopi. De giver vigtige oplysninger om infrarøde spektrale studier af laser gasser. Ofte er disse laser frekvenser bruges til at verificere analysen af infrarød og langtrækkende infrarød spektre, fordi de giver forbindelser mellem de ophidsede vibrationelle statslige niveauer, der er ofte direkte utilgængelige fra absorptionsspektre 19. De tjener også som den primære strålingskilde til studier, der undersøger forbigående, kortlivede frie radikaler med laseren magnetisk resonans-teknik 20. Med denne ekstremt følsomme teknik, roterende og ro-vibrationelle Zeeman spektre i paramagnetiske atomer, molekyler og molekylære ioner kan være Recorded og analyseret sammen med evnen til at undersøge reaktionshastighederne anvendes til at skabe disse frie radikaler.

I dette arbejde, en optisk pumpet molekylær laser, vist i figur 1, er blevet anvendt til at frembringe langtrækkende infrarød laserstråling fra difluormethan. Dette system består af en kontinuerlig bølge (cw) CO 2 pumpelaseren og en langtrækkende infrarød laser hulrum. Et spejl internt i langtrækkende infrarød laser kavitet omdirigerer CO 2 laserstråling ned poleret kobberrør, undergår seksogtyve overvejelser før afslutning ved udgangen af hulrummet, spredning resterende pumpestråling. Derfor langtrækkende infrarød laser medium exciteres ved hjælp af en tværgående pumpning geometri. For at generere laservirkning, er flere variable justeres, nogle samtidigt, og alle efterfølgende optimeres, når laserstråling observeres.

I dette eksperiment er langtrækkende infrarød laserstråling overvåges af en metal-isolator-metal (MIM) punkt kontakt diode detektor. MIM diodedetektor er blevet brugt til laser frekvensmåling siden 1969. 21 23 laserfrekvensen målinger, MIM diodedetektoren er en harmonisk blander mellem to eller flere strålingskilder, der falder på dioden. MIM diodedetektor består af en skærpet wolframtråd kontakte en optisk poleret nikkel bunden 24. Den nikkelbaseret har en naturligt forekommende tyndt oxidlag, som er det isolerende lag.

Når en laser emission blev påvist, blev dens bølgelængde, polarisering, styrke og optimeret driftstryk optaget under dens frekvens blev målt ved anvendelse af tre-laser heterodyn teknik 25 27 ved at følge fremgangsmåden oprindeligt beskrevet i ref. 4. Figur 2 viser den optisk pumpet molekylær laser med to yderligere CW CO 2 referencenumre lasere har uafhængige frekvens staseringsrådgivere systemer, der udnytter Lammet dukkert i 4,3 um fluorescenssignal fra en ekstern, lavtryk cellereferencen 28. Dette håndskrift skitserer den proces, der anvendes til at søge efter langtrækkende infrarød laser emissioner samt metoden til estimering af deres bølgelængde og i præcist bestemme deres frekvens. Specifikt med hensyn til tre-laser heterodyn teknik samt de forskellige komponenter og driftsparametre for systemet kan findes i Supplemental tabel A sammen med referencer 4, 25-27, 29, og 30.

Protocol

1. Planlægning af forsøg Foretage en undersøgelse af litteraturen til at vurdere forudgående arbejde udføres ved hjælp af laser-medie af interesse, hvilket for dette eksperiment er CH2F 2. Identificer alle kendte laser emission sammen med alle oplysninger om linjerne såsom deres bølgelængde og frekvens. Adskillige undersøgelser af kendte laser emissioner er tilgængelige 13,31 – 37. Kompilere alle spektroskopiske undersøgelser af mole…

Representative Results

Som nævnt, hyppigheden rapporteret for en langtrækkende infrarød laser emission er et gennemsnit på mindst tolv målinger udført med mindst to forskellige sæt af CO 2 referencenumre laserlinjer. Tabel 2 skitserer de registrerede data for 235,5 um laser emission ved brug af 9 P 04 CO 2 pumpelaser. Til dette langtrækkende infrarød laser emission, blev registreret fjorten individuelle målinger af rytmen frekvens. Det første sæt målinger blev registreret, mens du b…

Discussion

Der er flere kritiske trin i den protokol, der kræver nogle ekstra diskussion. Ved måling af langtrækkende infrarød laser bølgelængde, som beskrevet i trin 2.5.3, er det vigtigt at sikre den samme tilstand af langtrækkende infrarød laser emission bliver brugt. Flere former for et langtrækkende infrarød laser bølgelængde (dvs. TEM 00, TEM 01, etc.) kan genereres inden laserkaviteten og det er således vigtigt at identificere de relevante tilgrænsende hulrum modes bliver brugt t…

Disclosures

The authors have nothing to disclose.

Acknowledgements

This work was supported in part by the Washington Space Grant Consortium under Award NNX10AK64H.

Materials

Vacuum pump Leybold Trivac D4A HE-175 oil; Quantity = 3
Vacuum pump Leybold Trivac D8B or D16B Fomblin Fluid; Quantity = 1 of each
Vacuum pump Leybold Trivac D25B HE-175 oil; Quantity = 1
Optical chopper with controller Stanford Research Systems SR540
Lock-in amplifier Stanford Research Systems SR830
Spectrum analyzer Agilent E4407B ESA-E Series, 9 kHz to 26.5 GHz Spectrum Analyzer
Amplifier  Miteq AFS-44 Provides amplification of signals between 2 and 18 GHz. The amplifier is powered by a Hewlett Packard triple output DC power supply, model E3630A.
Amplifier  Avantek AWL-1200B Provides amplification of signals less than 1.2 GHz.
Power supply Hewlett Packard E3630A Low voltage DC power supply for amplifier.
Power supply Glassman KL Series High voltage power supply for the CO2 lasers; Quantity = 2; negative polarity
Power supply Fluke 412B High voltage power supply used with the NIST Asymmetric HV Amp
Detector Judson Infrared Inc J10D For fluorescence cell; Quantity = 2
CO2 laser spectrum analyzer Optical Engineering  16-A Currently sold by Macken Instruments Inc.
Thermal imaging plates with UV light Optical Engineering  Primarily used for aligning the CO2 reference lasers. Currently sold by Macken Instruments Inc.
Resistors Ohmite  L225J100K 100 kW, 225 W. Between 4 to 6 resistors are used in each ballast system. Each CO2 laser has its own ballast system. Fans are used to cool the resistors.
HV relay, SPDT CII Technologies H-17 Quantity = 3; one for each CO2 laser
Amplifier  Princeton Applied Research PAR 113 Used with fluorescence cell; Quantity = 2
Oscilloscope Tektronix 2235A Similar models are also used; Quantity = 2
Oscilloscope/Differential amplifier Tektronix 7903 oscilloscope with 7A22 differential amplifier
Power meter with sensor Coherent 200 For use below 10 W.  This is the power meter shown in Figure 2.
Power meter with sensor Scientech, Inc Vector S310 For use below 30 W
Multimeter Fluke 73III Similar models are also used; Quantity = 3
Data acquisition National Instruments NI cDAQ 9174 chassis with NI 9223 input module Uses LabVIEW software
Simichrome polish Happich GmbH Polish for the Nickel base used in the MIM diode detector. Although the Nickel base can be used immediately after polishing, a 12 hour lead time is typically recommended.
Pressure gauge Wallace and Tiernan 61C-1D-0050 Series 300; for CO2 laser; Quantity = 3
Pressure gauge with controller Granville Phillips Series 375 For far-infrared laser
Zirconium Oxide felt Zircar Zirconia ZYF felt Used as a beam stop
Zirconium Oxide board Zircar Zirconia ZYZ-3 board Used as a beam stop; Quantity = 4
Teflon sheet Scientific Commodities, Inc BB96312-1248 1/32 inch thick; used for the far-infrared laser output window
Polypropylene C-Line sheet protectors 61003 used for the far-infrared laser output window
Vacuum grease Apiezon
Power supply Kepco NTC 2000 PZT power supply
PZT tube Morgan Advanced Materials 1 inch length, 1 inch outer diameter, 0.062 inch thickness, reverse polarity (positive voltage on outside); Quantity = 3
ZnSe (AR coated) II-VI Inc CO2 laser window (Quantity = 3), lens, and beam splitter (Quantity 3)
NaCl window Edmond Optics Quantity = 1
CaF window Edmond Optics Quantity = 2
Laser mirrors and gratings Hyperfine, Inc Gold-coated; includes positioning mirrors
Glass laser tubes and reference cells Allen Scientific Glass
MIM diode detector Custom Microwave, Inc
Other Other materials include magnetic bases, base plates, base clamps, XYZ translation stage, etc.

References

  1. Hocker, L. O., Javan, A., Ramachandra Rao, D., Frenkel, L., Sullivan, T. Absolute frequency measurement and spectroscopy of gas laser transitions in the far infrared. Appl. Phys. Lett. 10 (5), 147-149 (1967).
  2. Wells, J. S., Evenson, K. M., Day, G. W., Halford, D. Role of infrared frequency synthesis in metrology. Proc. IEEE. 60 (5), 621-623 (1972).
  3. Whitford, B. G., Siemsen, K. J., Riccius, H. D., Baird, K. A. New frequency measurements and techniques in the 30-THz region. IEEE Trans. Instrum. Meas. 23 (4), 535-539 (1974).
  4. Petersen, F. R., et al. Far infrared frequency synthesis with stabilized CO2 lasers: Accurate measurements of the water vapor and methyl alcohol laser frequencies. IEEE J. Quantum Elect. 11 (10), 838-843 (1975).
  5. Uranga, C., Connell, C., Borstad, G. M., Zink, L. R., Jackson, M. Discovery and frequency measurement of short-wavelength far-infrared laser emissions from optically pumped 13CD3OH and CHD2OH. Appl. Phys. B. 88 (4), 503-505 (2007).
  6. Jackson, M., Milne, J. A., Zink, L. R. Measurement of optically pumped CH318OH laser frequencies between 3 and 9 THz. IEEE J. Quantum Elect. 47 (3), 386-389 (2011).
  7. Evenson, K. M., et al. Optically pumped FIR lasers: Frequency and power measurements and laser magnetic resonance spectroscopy. IEEE J. Quantum Elect. 13 (6), 442-444 (1977).
  8. Evenson, K. M., Jennings, D. A., Petersen, F. R. Tunable far-infrared spectroscopy. Appl. Phys. Lett. 44 (6), 576-577 (1984).
  9. Evenson, K. M., et al. Speed of light from direct frequency and wavelength measurements of the methane-stabilized laser. Phys. Rev. Lett. 29 (19), 1346-1349 (1972).
  10. BIPM. . Resolution 1. , 97-98 (1983).
  11. Giacomo, P. News from the BIPM. Metrol. 20 (1), 25-30 (1984).
  12. Chang, T. Y., Bridges, T. J. Laser action at 452, 496 and 541 µm in optically pumped CH3F. Opt. Commun. 1 (9), 423-426 (1970).
  13. Douglas, N. G., Walter, H. . Millimetre and Submillimetre Wavelength Lasers: A Handbook of CW Measurements. 61, (1989).
  14. Zerbetto, S. C., Vasconcellos, E. C. C., Zink, L. R., Evenson, K. M. 12CH2F2 and 13CH2F2 far-infrared lasers: New lines and frequency measurements. Int. J. Infrared Millim. Waves. 18 (12), 2301-2306 (1997).
  15. Jackson, M., Alves, H., Holman, R., Minton, R., Zink, L. R. New cw optically pumped far-infrared laser emissions generated with a transverse or ‘zig-zag’ pumping geometry. J. Infrared, Millim., Terahertz Waves. 35 (3), 282-287 (2014).
  16. Danielewicz, E. J., Button, K. J., Inguscio, M., Strumia, F. . The optically pumped difluoromethane far-infrared laser. Reviews of Infrared and Millimeter Waves. 2, 223-250 (1983).
  17. Deroche, J. C., Benichou, E. K., Guelachvili, G., Demaison, J. Assignments of submillimeter emissions in difluoromethane pumped by 12C18O2 and 12C18O2 lasers. Int. J. Infrared Millim. Waves. 7 (10), 1653-1675 (1986).
  18. Jackson, M., Zink, L. R., McCarthy, M. C., Perez, L., Brown, J. M. The far-infrared and microwave spectra of the CH radical in the v = 1 level of the X2Π. J. Mol. Spectrosc. 247 (2), 128-139 (2008).
  19. Zhao, S., Lees, R. M. CH318OH: Assignment of FIR laser lines optically pumped in the in-plane CH3-rocking band. J. Mol. Spectrosc. 168 (1), 67-81 (1994).
  20. Evenson, K. M., Saykally, R. J., Jennings, D. A., Curl, R. F., Brown, J. M. Far infrared laser magnetic resonance. Chemical and Biochemical Applications of Lasers. 5, 95-138 (1980).
  21. Hocker, L. O., Sokoloff, D. R., Daneu, V., Szoke, A., Javan, A. Frequency mixing in the infrared and far-infrared using a metal-to-metal point contact diode. Appl. Phys. Lett. 12 (12), 401-402 (1968).
  22. Daneu, V., Sokoloff, D., Sanchez, A., Javan, A. Extension of laser harmonic-frequency mixing techniques into the 9 μ region with an infrared metal-metal point-contact diode. Appl. Phys. Lett. 15 (12), 398-400 (1969).
  23. Jennings, D. A., Evenson, K. M., Knight, D. J. E. Optical Frequency Measurements. Proc. IEEE. 74 (1), 168-179 (1986).
  24. Zink, L. R. . Highly accurate molecular constants for CO, HF, HCl, OH, NaH, MgH, and O2: Rotational transition frequencies measured with tunable far infrared radiation [thesis]. , (1986).
  25. Xu, L. -. H., et al. Methanol and the optically pumped far-infrared laser. IEEE J. Quantum Elect. 32 (3), 392-399 (1996).
  26. Jackson, M., Zink, L. R., Garrod, T. J., Petersen, S., Stokes, A., Theisen, M. The generation and frequency measurement of short-wavelength far-infrared laser emissions. IEEE J. Quantum Elect. 41 (12), 1528-1532 (2005).
  27. Jackson, M., Smith, M., Gerke, C., Barajas, J. M. Measurement of far-infrared laser frequencies from methanol isotopologues. IEEE J. Quantum Elect. 51 (4), 1500105 (2015).
  28. Freed, C., Javan, A. Standing-wave saturation resonances in the CO2 10.6 μ transitions observed in a low-pressure room-temperature absorber gas. Appl. Phys. Lett. 17 (2), 53-56 (1970).
  29. DeShano, B., Olivier, K., Cain, B., Zink, L. R., Jackson, M. Using guide wavelengths to assess far-infrared laser emissions. J. Infrared, Millim., Terahertz Waves. 36 (1), 13-30 (2015).
  30. Jackson, M., Nichols, A. J., Womack, D. R., Zink, L. R. First laser action observed from optically pumped CH317OH. IEEE J. Quantum Elect. 48 (3), 303-306 (2012).
  31. Inguscio, M., Moruzzi, G., Evenson, K. M., Jennings, D. A. A review of frequency measurements of optically pumped lasers from 0.1 to 8 THz. J. Appl. Phys. 60 (12), R161-R191 (1986).
  32. Pereira, D., et al. A review of optically pumped far-infrared laser lines from methanol isotopes. Int. J. Infrared Millim. Waves. 15 (1), 1-44 (1994).
  33. Zerbetto, S. C., Vasconcellos, E. C. C. Far infrared laser lines produced by methanol and its isotopic species: A review. Int. J. Infrared Millim. Waves. 15 (5), 889-933 (1994).
  34. Moruzzi, G., Winnewisser, B. P., Winnewisser, M., Mukhopadhyay, I., Strumia, F. . Microwave, Infrared and Laser Transitions of Methanol: Atlas of Assigned Lines from 0 to 1258 cm-1. , (1995).
  35. Weber, M. J. . Handbook of Laser Wavelengths. , (1999).
  36. De Michele, A., et al. FIR laser lines from CH3OD: A review. Int. J. Infrared Millim. Waves. 25 (5), 725-734 (2004).
  37. De Michele, A., Carelli, G., Moruzzi, G., Moretti, A. Hydrazine far-infrared laser lines and assignments: a review. J. Opt. Soc. Am. B. 22 (7), 1461-1470 (2005).
  38. Moraes, J. C. S., et al. Experimental investigation of 13CD3OH infrared transitions by means of optoacoustic spectroscopy. Int. J. Infrared Millim. Waves. 13 (11), 1801-1823 (1992).
  39. Viscovini, R. C., Scalabrin, A., Pereira, D. Infrared optoacoustic spectroscopy of 13CD3OD around the 10R and 10P CO2 laser lines. Int. J. Infrared Millim. Waves. 17 (11), 1821-1838 (1996).
  40. Maki, A. G., Chou, C. C., Evenson, K. M., Zink, L. R., Shy, J. T. Improved molecular constants and frequencies for the CO2 laser from new high-J regular and hot-band frequency measurements. J. Mol. Spectrosc. 167 (1), 211-224 (1994).
  41. Douglas, N. G., Krug, P. A. CW laser action in ethyl chloride. IEEE J. Quantum Elect. 18 (10), 1409-1410 (1982).
  42. Schwaller, P., Steffen, H., Moser, J. F., Kneubühl, F. K. Interferometry of resonator modes in submillimeter wave lasers. Appl. Opt. 6 (5), 827-829 (1967).
  43. Steffen, H., Kneubühl, F. K. Resonator interferometry of pulsed submillimeter-wave lasers. IEEE J. Quantum Elect. 4 (12), 992-1008 (1968).
  44. Whitbourn, L. B., Macfarlane, J. C., Stimson, P. A., James, B. W., Falconer, I. S. An experimental study of a cw optically pumped far infrared formic acid vapour laser. Infrared Phys. 28 (1), 7-20 (1988).
  45. Belland, P., Véron, D., Whitbourn, L. B. Mode study, beam characteristics and output power of a cw 337 μm HCN waveguide laser. J. Phys. D: Appl. Phys. 8 (18), 2113-2122 (1975).
  46. Inguscio, M., Ioli, N., Moretti, A., Strumia, F., D’Amato, F. Heterodyne of optically pumped FIR molecular lasers and direct frequency measurement of new lines. Appl. Phys. B. 40 (3), 165-169 (1986).
  47. Carelli, G., et al. CH318OH: FIR laser line frequency measurements and assignments. Infrared Phys. Technol. 35 (6), 743-755 (1994).
  48. Pearson, J. C., Müller, H. S. P., Pickett, H. M., Cohen, E. A., Drouin, B. J. Introduction to submillimeter, millimeter and microwave spectral line catalog. J. Quant. Spectrosc. Radiat. Transf. 111 (11), 1614-1616 (2010).
  49. Ehasz, E. J., Goyette, T. M., Giles, R. H., Nixon, W. E. High-resolution frequency measurements of far-infrared laser lines. IEEE J. Quantum Elect. 46 (4), 474-477 (2010).
  50. Pearson, J. C., Drouin, B. J., Yu, S., Gupta, H. Microwave spectroscopy of methanol between 2.48 and 2.77 THz. J. Opt. Soc. Am. B. 28 (10), 2549-2577 (2011).
  51. Consolino, L., et al. Phase-locking to a free-space terahertz comb for metrological-grade terahertz lasers. Nat. Commun. 3, Article No. 1040 (2012).
  52. Bartalini, S., et al. Frequency-comb-assisted terahertz quantum cascade laser spectroscopy. Phys. Rev. X. 4 (2), 021006 (2014).
  53. Finneran, I. A., Good, J. T., Holland, D. B., Carroll, P. B., Allodi, M. A., Blake, G. A. Decade-spanning high-precision terahertz frequency comb. Phys. Rev. Lett. 114 (16), Article No. 163902 (2015).
  54. De Natale, P., et al. Quantum cascade laser THz metrology. Proc. SPIE.. , 93701D (2015).
  55. Dickinson, J. C., Goyette, T. M., Waldman, J. . High resolution imaging using 325 GHz and 1.5 THz transceivers. , 373-380 (2004).
  56. Vasconcellos, E. C. C., Zerbetto, S. C., Holecek, J. C., Evenson, K. M. Short-wavelength far-infrared laser cavity yielding new lines in methanol. Opt. Lett. 20 (12), 1392-1393 (1995).
check_url/53399?article_type=t

Play Video

Cite This Article
Jackson, M., Zink, L. R. Characterizing Far-infrared Laser Emissions and the Measurement of Their Frequencies. J. Vis. Exp. (106), e53399, doi:10.3791/53399 (2015).

View Video