Summary

डिजिटल छवि सहसंबंध का उपयोग संवहनी ऊतक नमूनों पर स्थानीय खींच विशेषताएँ

Published: January 24, 2016
doi:

Summary

We describe the use of digital image correlation to characterize the local surface strain field on vascular tissue samples subjected to uniaxial tensile testing. These measurements facilitate precise quantification of the sample mechanical response and the generation of constitutive stress-strain relations.

Abstract

Characterization of the mechanical behavior of biological and engineered soft tissues is a central component of fundamental biomedical research and product development. Stress-strain relationships are typically obtained from mechanical testing data to enable comparative assessment among samples and in some cases identification of constitutive mechanical properties. However, errors may be introduced through the use of average strain measures, as significant heterogeneity in the strain field may result from geometrical non-uniformity of the sample and stress concentrations induced by mounting/gripping of soft tissues within the test system. When strain field heterogeneity is significant, accurate assessment of the sample mechanical response requires measurement of local strains. This study demonstrates a novel biomechanical testing protocol for calculating local surface strains using a mechanical testing device coupled with a high resolution camera and a digital image correlation technique. A series of sample surface images are acquired and then analyzed to quantify the local surface strain of a vascular tissue specimen subjected to ramped uniaxial loading. This approach can improve accuracy in experimental vascular biomechanics and has potential for broader use among other native soft tissues, engineered soft tissues, and soft hydrogel/polymeric materials. In the video, we demonstrate how to set up the system components and perform a complete experiment on native vascular tissue.

Introduction

50 साल से अधिक फैले अनुसंधान का एक समृद्ध इतिहास संवहनी ऊतकों के यांत्रिक गुणों को बढ़ाता पर ध्यान केंद्रित किया गया है। इन अध्ययनों से हमें बेहतर, रक्त वाहिकाओं के शारीरिक और रोग व्यवहार दोनों को समझने प्रभावकारिता / अंतर्वाहिकी उपकरणों की अनुकूलता, और सहायता डिजाइन में और इंजीनियर की नाड़ी का निर्माण 1-6 निर्माणों के मूल्यांकन के लिए एक आधार प्रदान करने के लिए अनुमति देते हैं। मुलायम ऊतकों और उनके यांत्रिक गुणों के विधान मॉडलिंग के यांत्रिक प्रतिक्रिया का सही माप स्वाभाविक सबसे प्रकार के ऊतकों द्वारा प्रदर्शित यांत्रिक विविधता, anisotropy, और nonlinearity के कारण चुनौती दे रहा है। इसके अलावा, प्रयोगात्मक माप अक्सर स्थानीय यांत्रिक परीक्षण के पाठ्यक्रम में नमूना पकड़ इंटरफेस में शुरू की जटिलताओं (यानी, झुकने, घर्षण, तनाव सांद्रता, फाड़) और ऊतक रहने वाले जानवर से excised है एक बार यांत्रिक गुणों का अपरिहार्य संक्रमण से चकित हैं। </ P>

एक अक्षीय तन्यता प्रयोग एक ठोस सामग्री से बना एक नमूना पर प्रदर्शन किया जा सकता है कि सबसे सरल यांत्रिक परीक्षण के बीच में है, और अक्सर संवहनी ऊतक के यांत्रिक प्रतिक्रिया का आकलन करने के लिए प्रयोग किया जाता है। इन प्रयोगों से परिणाम दोनों देशी और इंजीनियर ऊतक स्रोतों के लिए उपयोगी प्रारंभिक जानकारी प्रदान करते हैं, और नाड़ी की दीवार 11/07 के यांत्रिक व्यवहार पर कुछ उपचार, रोग राज्यों, या औषधीय यौगिकों के प्रभाव की तुलना करने के लिए इस्तेमाल किया जा सकता है।

मुलायम ऊतकों की अक्षीय यांत्रिक परीक्षण आम तौर पर सबसे अधिक इस्तेमाल कुत्ते की हड्डी या अंगूठी 7,8,12-14 आकार के हैं, जो अपेक्षाकृत वर्दी ज्यामिति, साथ नमूनों पर किया जाता है। हालांकि, इन idealized geometries से महत्वपूर्ण प्रस्थान के कारण परीक्षण प्रणाली के भीतर ऊतक विच्छेदन, अलगाव, और clamping के साथ जुड़े चुनौतियों के लिए हो सकता है। ज्यामिति में किसी भी गैर एकरूपता अंततः विषम तनाव और तनाव को जन्म देगाखेतों नमूना वास्तविक नमूना आकार पर निर्भर विविधता, साथ ही नमूने का आकार (पकड़ती के सापेक्ष) और सामग्री 9,15,16 के यांत्रिक गुणों की डिग्री के साथ, एक अक्षीय विस्तार के अधीन है जब। क्षेत्र विषमताओं महत्वपूर्ण हैं, जब रिश्तेदार पकड़ पदों पर आधारित नमूना तनाव गणना गलत और यांत्रिक व्यवहार का आकलन करने के लिए इस प्रकार एक अपर्याप्त आधार हैं।

वीडियो विश्लेषण प्रणाली में व्यापक रूप से अक्सर नमूना सतह 17,18 के लिए लागू उच्च विपरीत डाई मार्कर का उपयोग, कोमल ऊतकों के तनाव माप के लिए इस्तेमाल किया गया है। डिजिटल छवि सहसंबंध, विरूपण पहले और बाद में नमूना की सतह पर ग्रे स्तर तीव्रता मूल्यों की तुलना द्वारा पूरे क्षेत्र की सतह तनाव उपाय जो एक ऑप्टिकल metrological तकनीक, कोमल ऊतकों 19-21 के विश्लेषण के वीडियो के साथ संयोजन के रूप में इस्तेमाल किया गया है। डिजिटल छवि सहसंबंध के कई फायदे interferometr की तुलना में कर रहे हैंमापन के लिए नियोजित किया जा सकता है कि आईसी तरीकों। सबसे पहले, एक गैर संपर्क माप तकनीक के रूप में, यह माप प्रणाली नमूना को प्रभावित करता है जिस तरह के कारण सामग्री के गुणों को संशोधित करने के confounding प्रभाव को कम करता है। दूसरा, यह एक बहुत कम कड़े माप वातावरण की आवश्यकता है और अन्य तरीकों से संवेदनशीलता और संकल्प की एक व्यापक रेंज है। तीसरा, देखने का एक पूरा क्षेत्र पर कब्जा करने की क्षमता के साथ संपन्न, इस तकनीक के औसत और स्थानीय यांत्रिक प्रतिक्रियाओं दोनों चिह्नित कर सकते हैं। विधि का विस्तृत विवरण, पाठकों सटन 22 से किताब देखने के लिए प्रोत्साहित किया जाता है।

नमूना सतह पर तनाव क्षेत्रों प्राप्त करने के लिए, एक दो आयामी डिजिटल छवि सहसंबंध तकनीक (2 डी डीआईसी) का इस्तेमाल किया जा सकता है। संक्षेप में, नमूना की छवियों को उतार दिया और विभिन्न भरी हुई राज्यों पर कब्जा कर रहे हैं। पहली छवि के बाद गणना के लिए एक जाल के रूप में जो सबसेट (एम × एम पिक्सल) नामक छोटे वर्गों में बांटा गया है2 डी तनाव खेतों। विकृत नमूना में प्रत्येक वर्ग की स्थिति को एक छवि से मेल खाते एल्गोरिथ्म का उपयोग कर प्राप्त की है। प्रत्येक वर्ग की गति तो तब बहुपद फिटिंग या परिमित तत्व प्रक्षेप सहित तरीकों की एक किस्म है, के माध्यम से विरूपण ढ़ाल और दबाव से प्राप्त करने के लिए इस्तेमाल किया जा सकता है, जो विस्थापन के खेतों से बेदखल, छवि-दर-छवि, पता लगाया है। वर्तमान पांडुलिपि में, हम एक अक्षीय तनन परीक्षण और 2 डी डीआईसी के एकीकरण के माध्यम से मूल निवासी संवहनी ऊतकों पर सतह तनाव क्षेत्रों के आकलन के लिए एक विस्तृत कार्यप्रणाली प्रदान करते हैं।

Protocol

नोट: नीचे वर्णित प्रक्रियाओं कोलंबिया में दक्षिण कैरोलिना विश्वविद्यालय, दक्षिण कैरोलिना में संस्थागत पशु की देखभाल और उपयोग समिति द्वारा अनुमोदित एक प्रोटोकॉल के हिस्से के रूप में प्रदर्शन किया गया। <p class…

Representative Results

संवहनी ऊतक पर एक ramped अक्षीय विस्तार परीक्षण से प्राप्त कर लिया यांत्रिक डेटा एक दिया विस्थापन दर से लागू नमूना विस्थापन रिश्तों बनाम भार के होते हैं। इस अध्ययन में, एक अक्षीय यांत्रिक परीक?…

Discussion

पिछले अध्ययनों नमूना तनाव 18,20,21,23,24 आकलन करने के लिए डाई-ट्रैकिंग वीडियो तरीकों की एक विस्तृत रेंज का इस्तेमाल किया है, हमारे वर्तमान उद्देश्य के आकलन के लिए 2 डी डीआईसी के साथ जोड़ी अक्षीय तनन परीक्षण…

Disclosures

The authors have nothing to disclose.

Acknowledgements

सॉफ्टवेयर और तकनीकी सहायता सहसंबद्ध समाधान शामिल (www.correlatedsolutions.com) के सौजन्य से किया गया।

Materials

Uniaxial tensile mechanical tester Enduratec 3230 AT/HR
Blue tissue marking dye http://www.ebay.com/itm/Tissue-Marking-Dye-in-Bottles-2oz-Bottle-1-ea-/201193551510?pt=LH_DefaultDomain_0&hash=item2ed811f696
Sprayer Anest-iwata CM-B Custom Micron B
Camera Point Grey GS2-GE-50S5M-C
Lens Tokina AT-X M100
Vascular tissue Caughman Inc
0.9% Sodium Chloride Injection PBS BAXTER HEALTHCARE CORP.
Vic_snap Correlated Solutions
Vic_2D Correlated Solutions
Wintest 4.1 Bose ElectroForce
Tissue adhesive  3M Vetbond  1469SB
Disinfectant  Fisher Scientific 04-355-13 Decon BDD Bacdown Detergent Disinfectant

References

  1. Holzapfel, G. A. Biomechanics of soft tissue. The handbook of materials behavior models. 3, 1049-1063 (2001).
  2. Vito, R. P., Dixon, S. A. Blood vessel constitutive models-1995-2002. Annu Rev Biomed Eng. 5, 413-439 (2003).
  3. Dodson, R. B., Martin, J. T., Hunter, K. S., Ferguson, V. L. Determination of hyperelastic properties for umbilical artery in preeclampsia from uniaxial extension tests. Eur J Obstet Gynecol Reprod Biol. 169, 207-212 (2013).
  4. Chuong, C. J., Fung, Y. C. On residual stresses in arteries. J Biomech Eng. 108, 189-192 (1986).
  5. Borschel, G. H., et al. Tissue engineering of recellularized small-diameter vascular grafts. Tissue Eng. 11, 778-786 (2005).
  6. Wagenseil, J. E., Mecham, R. P. Vascular extracellular matrix and arterial mechanics. Physiol Rev. 89, 957-989 (2009).
  7. Holzapfel, G. A. Determination of material models for arterial walls from uniaxial extension tests and histological structure. J Theor Biol. 238, 290-302 (2006).
  8. Tanaka, T. T., Fung, Y. C. Elastic and inelastic properties of the canine aorta and their variation along the aortic tree. J Biomech. 7, 357-370 (1974).
  9. Sokolis, D. Passive mechanical properties and structure of the aorta: segmental analysis. Acta physiologica. 190, 277-289 (2007).
  10. Twal, W., et al. Cellularized Microcarriers as Adhesive Building Blocks for Fabrication of Tubular Tissue Constructs. Ann Biomed Eng. , 1-12 (2013).
  11. Shazly, T., et al. On the Uniaxial Ring Test of Tissue Engineered Constructs. Exp Mech. , 1-11 (2014).
  12. Kim, J., Baek, S. Circumferential variations of mechanical behavior of the porcine thoracic aorta during the inflation test. J Biomech. 44, 1941-1947 (2011).
  13. Li, L., et al. Determination of material parameters of the two-dimensional Holzapfel-Weizsacker type model based on uniaxial extension data of arterial walls. Comput Methods Biomech Biomed Engin. 16, 358-367 (2013).
  14. Li, L., et al. Determination of the material parameters of four-fibre family model based on uniaxial extension data of arterial walls. Comput Methods Biomech Biomed Engin. 17, 695-703 (2014).
  15. Hoeltzel, D. A., Altman, P., Buzard, K., Choe, K. I. Strip extensiometry for comparison of the mechanical response of bovine, rabbit, and human corneas. J Biomech Eng. 114, 202-215 (1992).
  16. Guo, X., Kassab, G. S. Variation of mechanical properties along the length of the aorta in C57bl/6 mice. Am J Physiol Heart Circ Physiol. 285, H2614-H2622 (2003).
  17. Smutz, W., Drexler, M., Berglund, L., Growney, E., An, K. Accuracy of a video strain measurement system. J Biomech. 29, 813-817 (1996).
  18. Genovese, K., Lee, Y. U., Lee, A. Y., Humphrey, J. D. An improved panoramic digital image correlation method for vascular strain analysis and material characterization. J Mech Behav Biomed Mater. 27, 132-142 (2013).
  19. Wang, C. C., Deng, J. M., Ateshian, G. A., Hung, C. T. An automated approach for direct measurement of two-dimensional strain distributions within articular cartilage under unconfined compression. J Biomech Eng. 124, 557-567 (2002).
  20. Ning, J., et al. Deformation measurements and material property estimation of mouse carotid artery using a microstructure-based constitutive model. J Biomech Eng. 132, 121010 (2010).
  21. Sutton, M. A., et al. Strain field measurements on mouse carotid arteries using microscopic three-dimensional digital image correlation. J Biomed Mater Res A. 84, 178-190 (2008).
  22. Sutton, M. A., Orteu, J. J., Schreier, H. . Image correlation for shape, motion and deformation measurements: basic concepts, theory and applications. , (2009).
  23. Verhulp, E., van Rietbergen, B., Huiskes, R. A three-dimensional digital image correlation technique for strain measurements in microstructures. J Biomech. 37, 1313-1320 (2004).
  24. Wang, C. C., Deng, J. M., Ateshian, G. A., Hung, C. T. An automated approach for direct measurement of two-dimensional strain distributions within articular cartilage under unconfined compression. Journal of Biomechanical Engineering. 124, 557-567 (2002).
  25. Franck, C., Hong, S., Maskarinec, S., Tirrell, D., Ravichandran, G. Three-dimensional full-field measurements of large deformations in soft materials using confocal microscopy and digital volume correlation. Exp Mech. 47, 427-438 (2007).
  26. Garcia, A., et al. Experimental study and constitutive modelling of the passive mechanical properties of the porcine carotid artery and its relation to histological analysis: Implications in animal cardiovascular device trials. Med Eng Phys. 33, 665-676 (2011).
  27. Miller, K. How to test very soft biological tissues in extension?. J Biomech. 34, 651-657 (2001).
  28. Sutton, M. A. . Springer handbook of experimental solid mechanics. , 565-600 (2008).
  29. Han, H. C., Fung, Y. C. Longitudinal strain of canine and porcine aortas. J Biomech. 28, 637-641 (1995).
  30. Sokolis, D. P. A passive strain-energy function for elastic and muscular arteries: correlation of material parameters with histological data. Med Biol Eng Comput. 48, 507-518 (2010).
  31. Zhou, B., Wolf, L., Rachev, A., Shazly, T. A structure-motivated model of the passive mechanical response of the primary porcine renal artery. J Mech Med Biol. , (2013).
  32. Zhou, B., Rachev, A., Shazly, T. The biaxial active mechanical properties of the porcine primary renal artery. J Mech Behav Biomed Mater. 48, 28-37 (2015).
  33. Sommer, G., Holzapfel, G. A. 3D constitutive modeling of the biaxial mechanical response of intact and layer-dissected human carotid arteries. J Mech Behav Biomed Mater. 5, 116-128 (2012).
check_url/53625?article_type=t

Play Video

Cite This Article
Zhou, B., Ravindran, S., Ferdous, J., Kidane, A., Sutton, M. A., Shazly, T. Using Digital Image Correlation to Characterize Local Strains on Vascular Tissue Specimens. J. Vis. Exp. (107), e53625, doi:10.3791/53625 (2016).

View Video