This protocol describes simultaneous measurement of electroretinogram and visual evoked potentials in anesthetized rats.
The electroretinogram (ERG) and visual evoked potential (VEP) are commonly used to assess the integrity of the visual pathway. The ERG measures the electrical responses of the retina to light stimulation, while the VEP measures the corresponding functional integrity of the visual pathways from the retina to the primary visual cortex following the same light event. The ERG waveform can be broken down into components that reflect responses from different retinal neuronal and glial cell classes. The early components of the VEP waveform represent the integrity of the optic nerve and higher cortical centers. These recordings can be conducted in isolation or together, depending on the application. The methodology described in this paper allows simultaneous assessment of retinal and cortical visual evoked electrophysiology from both eyes and both hemispheres. This is a useful way to more comprehensively assess retinal function and the upstream effects that changes in retinal function can have on visual evoked cortical function.
Måling av elektroretinogrammet (ERG) og visuell fremkalt potensial (VEP) gir nyttige kvantitative vurderinger av integriteten av visuelle veien. ERG måler de elektriske responser i netthinnen til lys stimulering, mens den VEP måler den tilsvarende funksjonell integritet av synsbanene fra retina til den primære visuelle cortex å følge den samme lys hendelse. Dette manuskriptet beskriver en protokoll for registrering og analyse av ERG og VEP responser i et vanlig laboratoriemodell, rotten.
ERG gir en indeks av den funksjonelle integriteten til en rekke sentrale retinal celle klasser ved å tallfeste netthinnen brutto elektriske respons til et lysglimt. En koordinert serie av ioniske flussmidler initieres av lys begynn og offset, gi målbare forandringer i spenning som kan måles ved hjelp av overflate elektroder plassert utenfor øyet. Den resulterende bølgeform representerer kombinasjonen av en i seg selvrier av veldefinerte komponenter, ulik amplitude, timing og frekvens. En betydelig mengde forskning har vist at disse komponentene er relativt godt konservert på tvers av mange virveldyr retinae og at komponentene kan separeres fra hverandre. Ved judiciously velge stimulus (flash stimulus, bakgrunn, interstimulus intervall) forhold og velge spesifikke funksjoner i den sammensatte bølgeform å analysere kan man være sikker på å returnere et mål på en bestemt gruppe av netthinnens celler 1,2. Disse egenskapene ligger til grunn for verktøyet, og dermed den utbredte anvendelser av ERG som et non-invasiv måling av netthinnen funksjon. Dette manuskriptet fokuserer på metodikk for å måle ERG og analysere sine funksjoner for å returnere informasjon om noen av de store celle klasser i netthinnen, nemlig fotoreseptorer (PIII komponent), bipolare celler (PII komponent) og gangliecelle (den positive scotopic terskel svar eller pSTR).
<p class= "Jove_content"> The VEP gir en analyse av kortikale respons på lys; første stammer fra netthinnen og deretter kommunisert serielt via synsnerven, synskanalen, thalamus (lateral geniculate kjernen, LGN) og optisk stråling til området V1 av cortex tre. I gnagere, majoriteten (90 – 95%) av optisk nervefibre fra hvert øye decussate 4 og innerverer kontralaterale midten av hjernen. I motsetning til ERG, er det foreløpig ikke mulig å tillegge forskjellige komponenter av VEP til spesifikke celle klasser, 5 endrer dermed hvor som helst langs den visuelle pathway kan påvirke VEP bølgeform. Ikke desto mindre er det VEP et nyttig ikke-invasiv måling av visuell ytelse og visuell vei integritet. Den VEP, når det brukes sammen med ERG, kan gi en mer fullstendig vurdering av det visuelle system (dvs. netthinnen / visuelle veien).ERG og VEP opptak kan gjennomføres isolert eller i kombinasjon, avhengig av apparakasjon. Metodikken er beskrevet i denne artikkelen tillater samtidig vurdering av retinal og kortikal visuell fremkalt elektrofysiologi fra begge øynene og begge halvkuler i bedøvet rotter. Dette er en nyttig måte å mer grundig vurdere retinal funksjon og oppstrøms effekter som endringer i netthinnefunksjon kan ha på visuell fremkalt kortikal funksjon.
ERG og VEP er objektive mål på visuell funksjon fra netthinnen og cortex, henholdsvis. Fordelen med samtidig opptak er at en mer omfattende oversikt over hele visuelle veien er råd. Spesielt kan utfyllende informasjon fra sine samtidige vurdering gi en klarere avgrensning av skadestedet i det visuelle pathway (f.eks for lidelser med overlappende ERG ennå tydelig VEP manifestasjoner 18, når optikusnevropati kan sameksistere med primær cerebral atrofi 19, 20, eller når VEP tap kan bli…
The authors have nothing to disclose.
Funding for this project was provided by the National Health and Medical Research Council (NHMRC) 1046203 (BVB, AJV) and Melbourne Neuroscience Institute Fellowship (CTN).
Alligator clip | generic brand | HM3022 | Stainless steel 26 mm clip for connecting VEP screw electrodes to cables |
Bioamplifier | ADInstruments | ML 135 | For amplifying ERG and VEP signals |
Carboxymethylcellulose sodium 1.0% | Allergan | CAS 0009000-11-7 | Viscous fluid for improving signal quality of the active ERG electrode |
Carprofen 0.5% | Pfizer Animal Health Group | CAS 53716-49-7 | Proprietary name: Rimadyl injectable (50 mg/mL). For post-surgery analgesia, diluted to 0.5% (5 mg/mL) in normal saline |
Chlorhexadine 0.5% | Orion Laboratories | 27411, 80085 | For disinfecting surgical instruments |
Circulating water bath | Lauda-Königshoffen | MGW Lauda | For maintaining body temperature of the anesthetized animal during surgery and electrophysiological recordings |
Dental amalgam | DeguDent GmbH | 64020024 | For encasing the electrode-skull assembly to make it more robust |
Dental burr | Storz Instruments, Bausch and Lomb | #E0824A | A miniature drill head of ~0.7mm diameter for making a small hole in the skull over each hemisphere to implant VEP screws |
Drill | Bosch | Dremel 300 series | An automatic drill for trepanning |
Electrode lead | Grass Telefactor | F-E2-30 | Platinum cables for connecting silver wire electrodes to the amplifier |
Faraday Cage | custom-made | Ensures light proof to maintain dark adaptation. Encloses the Ganzfeld setup to improve signal to noise ratio | |
Gauze swabs | Multigate Medical Products Pty Ltd | 57-100B | For drying the surgical incision and exposed skull surface during surgery |
Ganzfeld integrating sphere | Photometric Solutions International | Custom designed light stimulator: 36 mm diameter, 13 cm aperture size | |
Velcro | VELCRO Australia Pty Ltd | VELCRO Brand Reusable Wrap | Hook-and-loop fastener to secure the electrodes and the animal on the recording platform |
Isoflurane 99.9% | Abbott Australasia Pty Ltd | CAS 26675-46-7 | Proprietary Name: Isoflo(TM) Inhalation anaaesthetic. Pharmaceutical-grade inhalation anesthetic mixed with oxygen gas for VEP electrode implant surgery |
Ketamine | Troy Laboratories | Ilium Ketamil | Proprietary name: Ketamil Injection, Brand: Ilium. Pharmaceutical-grade anesthetic for electrophysiological recording |
Luxeon LEDs | Phillips Lighting Co. | For light stimulation twenty 5 watt and one 1 watt LEDs. | |
Micromanipulator | Harvard Apparatus | BS4 50-2625 | Holds the ERG active electrode during recordings |
Needle electrode | Grass Telefactor | F-E2-30 | Subcutaneously inserted in the tail to serve as the ground electrode for both the ERG and VEP |
Phenylephrine 2.5% minims | Bausch and Lomb | CAS 61-76-7 | Instilled with Tropicamide to achieve maximal dilation for ERG recording |
Povidone iodine 10% | Sanofi-Aventis | CAS 25655-41-8 | Proprietory name: Betadine, Antiseptic to prepare the shaved skin for surgery 10%, 500 mL |
Powerlab data acquisition system | ADInstruments | ML 785 | Controls the LEDs |
Proxymetacaine 0.5% | Alcon Laboratories | CAS 5875-06-9 | For corneal anaesthesia during ERG recordings |
Saline solution | Gelflex | Non-injectable, for electroplating silver wire electrodes | |
Scope Software | ADInstruments | version 3.7.6 | Simultaneously triggers the stimulus via the Powerlab system and collects data |
Silver (fine round wire) | A&E metal | 0.3 mm | Used to make active and inactive ERG electrodes, and the inactive VEP electrode |
Stainless streel screws | MicroFasterners | 0.7 mm shaft diameter, 3 mm in length to be implanted over the primary visual cortex and serve as the active VEP electrodes | |
Stereotaxic frame | David Kopf | Model 900 | A small animal stereotaxic instrument for locating the primary visual cortices according to Paxinos & Watson's 2007 rat brain atlas coordinates |
Surgical blade | Swann-Morton Ltd. | 0206 | For incising the area of skin overlaying the primary visual cortex to implant the VEP electrodes |
Suture | Shanghai Pudong Jinhuan Medical Products Co.,Ltd | 3-0 silk braided suture non-absorbable, for skin retraction during VEP electrode implantation surgery | |
Tobramycine eye ointment 0.3% | Alcon Laboratories | CAS 32986-56-4 | Proprietary name: Tobrex. Prophylactic antibiotic ointment applied around the skin wound after surgery |
Tropicamide 0.5% | Alcon Laboratories | CAS 1508-75-4 | Proprietary name: 0.5% Mydriacyl eye drop, Instilled to achieve mydriasis for ERG recording |
Xylazine | Troy Laboratories | Ilium Xylazil-100 | Pharmaceutical-grade anesthetic for electrophysiological recording |
Pipette tip | Eppendorf Pty Ltd | 0030 073.169 | Eppendorf epTIPS 100 – 5000 mL, for custom-made electrodes |
Microsoft Office Excel | Microsoft | version 2010 | spreadsheet software for data analysis |
Lethabarb Euthanazia Injection | Virbac (Australia) Pty Ltd | LETHA450 | 325 mg/mL pentobarbital sodium for rapid euthanazia |