Waiting
Login processing...

Trial ends in Request Full Access Tell Your Colleague About Jove
Click here for the English version

Medicine

Vurdering af Child antropometri i en stor epidemiologisk undersøgelse

Published: February 2, 2017 doi: 10.3791/54895

Abstract

En stor del af børnene har overvægt og fedme i USA og andre lande. Præcis vurdering af antropometri er vigtigt at forstå sundhedsmæssige virkninger af børns vækst og fedme. Guld standard metoder til måling af fedme, såsom dual X-ray absorptiometri (DXA), kan ikke lade sig gøre i store feltundersøgelser. Forskning personale kan dog komplet antropometriske målinger, såsom krop omkredse og skinfold målinger, der bruger billig bærbart udstyr. I denne protokol vi detaljer, hvordan at opnå manuelle antropometriske målinger fra børn, herunder stående og siddende højde, vægt, taljemål, hofte omkreds, mid-overarm omkreds, triceps skinfold tykkelse og subscapular skinfold tykkelse, og procedurer til at vurdere kvaliteten af disse målinger. For at demonstrere nøjagtigheden af ​​disse målinger, blandt 1.110 skolebørn i før-fødselsårgang Projekt Viva vi beregnet Spearman corrElation koefficienter sammenligner manuelle antropometriske målinger med en guld standard mål for kropsfedt, DXA fedtmasse 1. For at løse pålidelighed, vurderer vi intra-rater teknisk målefejl på en kvalitetskontrol session udført på voksne kvindelige frivillige.

Introduction

Overvægt og fedme forblive på epidemiske niveauer, med cirka en tredjedel af amerikanske børn og to tredjedele af voksne, der har overvægtige eller fedme, ifølge 2011 - 2012 anslår 2. Overvægt, fedme, og overskydende kropsfedt giver større risiko for negative cardiometaboliske resultater, herunder type 2-diabetes og hjerte-kar-sygdomme, samt andre negative fysiske og psykiske sundhedsresultater, herunder astma og depression 3, 4, 5, 6.

De fleste undersøgelser, der undersøger sammenhængen mellem fedme og senere-life sundhedsresultater antager nøjagtige målinger af vægt og længde / højde. Kategorier af vægt status hos voksne og børn indbefatter undervægtige (body mass index (BMI) <18,0 kg / m2 for voksne og <5 th alder køn-specifik percentil for børn), ingenrmal vægt (BMI 18,0 til <25,0 kg / m 2 for voksne og 5 th til <85 percentil for børn), overvægt (BMI 25,0 til <30,0 kg / m 2 for voksne og 85 th til <95 percentilen for børn) og fedme (BMI ≥ 30 kg / m 2 for voksne og ≥ 95 percentil for børn). Selv mindre målefejl kan påvirke disse kategoriseringer, især hos børn, for hvem fejl, der vises små på en absolut skala kan repræsentere en stor fejl i forhold til barnets størrelse 7. For eksempel i en forudgående undersøgelse af børn under 2 år, sammenligninger af længden målt ved den konventionelle kliniske papir-og-blyant metode med den liggende længde-board metoden viste, at papir-og-blyant metode systematisk overvurderet længde med gennemsnitligt på 1,3 (1,5) cm - en fejl, der resulterer i en betydelig misklassifikation 7.

1. Således metoder, der direkte måler fedme er også vigtige for at forstå relationer med sundhedsresultater.

Gold standard metoder til overvægt og kropssammensætning måling generelt stole på teknologiske metoder, herunder luft forskydning plethysmografi (ADP), hydrostatisk vejning, magnetisk resonans imaging (MRI), og computertomografi (CT), samt dual X-ray absorptiometri (DXA ) 8, 9, 10. mens dissemetoder giver nogle af de mest nøjagtige mål for kropssammensætning, mange af dem er ikke praktiske i pædiatriske forskningsundersøgelser, navnlig dem, der feltbaserede. For eksempel, hydrostatisk vejning kræver, at enkeltpersoner være helt nedsænket i vand. ADP udstyr har, indtil for ganske nylig, kun været tilgængelige til at måle spædbørn op til 8 kg eller børn og voksne, der er fyldt 6 år, men ikke småbørn eller førskole-alder børn. CT-scanninger udsender en stor mængde stråling sammenlignet med de andre teknikker, og den lange erhvervelse tid til MRI gør det upraktisk for mange undersøgelser 8. DXA udleder omkring 1/500 stråledosis af en CT-scanning, omtrent svarende til en dag i naturlige baggrundsstråling 11, hvilket gør det en attraktiv mulighed for forskningsundersøgelser, der involverer børn. Alle disse metoder er imidlertid dyrt at købe og ingen er bærbare, hvilket gør dem umuligt for felt-baserede undersøgelser med begrænset fondIng. Bioelectrical impedans analyse (BIA), som måler impedans et minut elektrisk signal sendes gennem kroppen at estimere kropssammensætning, kan være billigere og mere bærbare, men forudsætninger for beregning af kropsfedt gælder ikke for små børn 10.

I modsætning til disse teknologi-baserede foranstaltninger, kan manuelle antropometriske foranstaltninger udføres af en uddannet observatør i de fleste field settings og på et væsentligt lavere udstyr omkostninger. Manuel antropometri omfatter målinger af højde, vægt, omkredse og skinfold tykkelser 8. Andre fordele ved manuel antropometri er, at det ikke indebærer nogen unødig stråling, og dygtige personale kan få dem effektivt. En fælles bekymring for manuelle antropometriske målinger er, at de kan være både unøjagtig og upræcis 12.

Indhentning nøjagtig og PRecise målinger er muligt med standardiserede procedurer, tilstrækkelig uddannelse og tilstrækkelig opmærksomhed til kvalitetskontrol (QC) procedurer. Projektet Viva team har udviklet en manual antropometri træning protokol, som kan give høj kvalitet, reproducerbare målinger af statur, omkreds, og skinfold tykkelse. Over mere end et årti, har vi anvendt denne uddannelse og QC-protokol til mødre og børn i Project Viva, en langsgående, præ-fødsel kohorteundersøgelse 13. Projekt Viva personale indsamlet antropometriske foranstaltninger vedrørende børn under besøg ved fødslen (0 - 3 dage), og med både mor og barn på følgende tidspunkter: vorden (4,9 - 10,6 måneder), den tidlige barndom (2,8 - 6,3 år), mid -childhood (6,6 - 10,9 år), og tidlig teen (11,5 - 16,5 år) 13.

Dette papir beskriver den protokol vi udviklet og forfinet til måling af højde, vægt, skinfold tykkelser (triceps og subscapular skinfolds) og body omkredse (talje, hofte og midt-overarm omkredse [MUAC]) i Project Viva. Vi beskriver også, hvordan vi har vurderet både manuel antropometriske målinger præcision ved hjælp af teknisk fejl af måle- (TEM) beregninger og nøjagtighed i forhold til guld standard DXA-målinger.

Subscription Required. Please recommend JoVE to your librarian.

Protocol

Alle procedurer er godkendt af Harvard Pilgrim Health Care Institutional Review Board.

1. Uddannelse Procedurer

  1. Har praktikanter (forskning assistenter) gennemfører en multi-dages, flere timer træningsprogram til at lære korrekt placering, se træningsvideoer, og modtage i-personers uddannelse fra en erfaren auxologist.
    1. Instruer eleverne at øve udføre målinger på hinanden, mens en auxologist eller bosiddende antropometri ekspert vurderer hver elev teknik og gør passende justeringer.
    2. Organiser en workshop med eksterne frivillige, optimalt for en række forskellige aldre og kropstyper, ideelt set et repræsentativt udsnit af den undersøgte population. Har eleverne måle hver frivilligt minimum to gange om måling.
  2. Efter endt uddannelse, har de studerende tilbringer cirka en ekstra 40-50 h øve manuel antropometriteknikker til hinanden og frivillige. I løbet af denne tid, observere eleverne, overvågning overholdelse protokol og korrekt teknik. Giv hver elev den nødvendige mængde af uddannelse baseret på medfødte niveau og tidligere erfaring.

2. Fremstilling af emner

  1. Instruer deltagerne til at bære let tøj, der giver let adgang til ekstremiteterne og overkrop samtidig opretholde beskedenhed, optimalt et standard tøj leveres af forskningen personale.

3. Højde

  1. Mål højden ved hjælp af et velopbygget stadiometer, som kan monteres på væggen eller bærbare. Uanset hvad, tage målinger samtidig sikre, at stadiometer er sat op mod en væg på en hård, flad overflade.
    BEMÆRK: Blandt børn under 2 år, måle liggende længde i stedet for ståhøjde. Længde målinger liggende kræver forskellige procedurer 8, ikke detaljerede i denne protokol.
  2. ENsk deltageren, før at træde på stadiometer, for at fjerne eventuelle genstande, der kan hindre målinger. For eksempel, sko, tykke sokker, hatte og hårpynt (f.eks hatte, pandebånd, hår bands på kronen af hovedet).
  3. Guide deltageren tilbage på brættet indtil deltagerens bagdel, skulderblade, eller bagsiden af ​​hovedet komme i kontakt med bestyrelsen.
  4. Mens vender deltageren instruere deltageren at stå på brættet med fødderne spredt ca. 2 fod fra hinanden. Spørg deltageren til langsomt tommer hans / hendes ben sammen igen, indtil benene, midten lår, knæ eller fødder komme i kontakt.
  5. Instruer deltageren til at stå så lige som muligt, uden at ludende eller hælder. Sørg for, at fødder er fladt på bunden af ​​højden bord eller gulv, og armene hænge ned af deltagerens sider. Bekræft, at vægten er jævnt fordelt mellem de venstre og højre side af kroppen.
  6. Visuelt kontrollere, at mid-aksillær linje ervinkelret på gulvet. Instruer deltageren til at flytte hans / hendes fødder væk fra bagsiden af ​​stadiometer hvis det er nødvendigt for at opnå denne position.
    BEMÆRK: mid-axillær linje er en imaginær linje i koronale plan midtvejs mellem den forreste axillære linje og den bageste axillære linje, der strækker sig fra midten af armhulen ned gennem den mest overlegne del af hoftebensranden (figur 1).

figur 1
Figur 1: Placering af Mid-aksillær Line. En koronale linje halvvejs mellem de anteriore og posteriore axillære linier 15. Klik her for at se en større version af dette tal.

  1. Spørg deltageren at stå oprejst. Sikre, at en eller flere af de efter kropsdele kommer i kontakt med bagsiden af ​​stadiometer: fødder, hoved, skuldre, eller balder.
  2. Placer deltagerens hovedet ind i Frankfort Plane (figur 2).
    1. Bestem Frankfort Plane ved at gøre følgende: Ser man på den side af deltagerens hoved, tegne en imaginær linje fra den laveste margin af øjet kredsløb til den højeste margen ved åbningen af ​​øregangen. Placer hovedet, således at den imaginære linje er parallelt med gulvet og vinkelret på stadiometer.

Figur 2
Figur 2: Frankfort Plane. En vandret plan, som passerer gennem den nedre kant af kredsløb og tragion (hak over tragus af øret) 16.4895fig2large.jpg "target =" _ blank "> Klik her for at se en større version af dette tal.

  1. Mind deltageren at stå lige og høj, og placer medaljon fast på toppen af ​​hans / hendes hoved med tilstrækkeligt tryk til at komprimere håret og komme i kontakt med kraniet. Med medaljon i øjenhøjde, tage målingen til nærmeste tiendedel centimeter.

4. siddehøjde

  1. Placer stadiometer oven på en robust skammel høj nok til at tillade deltagerens ben for at danne en 90 ° vinkel med jorden. Alternativt, hvis stadiometer er vægmonteret, placere en skammel med kendt højde foran stadiometer.
  2. Spørg deltageren at sidde på stadiometer eller på toppen af ​​afføring, så bagdelen rører bagsiden af ​​brættet.
  3. Har deltageren sidde så oprejst som muligt, med balder, skuldre og / eller hoved rører bagsiden af ​​brættet. Sørg for, at mid-axillAry linje (som beskrevet i 3.6) er vinkelret på afføring og parallelt med stadiometer.
  4. Guide deltagerens knæ direkte foran hans / hendes krop, og placere hans / hendes hænder på lårene.
  5. Placer deltagerens hovedet ind i Frankfort Plane. Se 3.8.
  6. Placer headpiece fast på toppen af ​​deltagerens hoved med tilstrækkeligt tryk til at komprimere håret og komme i kontakt med kraniet.
  7. Mens direkte ud mod måling indekset med medaljon i øjenhøjde, tager målingen til nærmeste tiendedel centimeter.

5. Vægt

  1. Instruer deltageren til at bære enten lys tøj eller standard tøj leveres i begyndelsen af ​​de antropometriske målinger, at tømme hans / hendes blære, og til at fjerne hans / hendes sko, inden du forsøger vægten måling.
  2. Spørg deltageren, at stå på skalaen. Optag målingen til nærmeste tiendedel af et kilogram.

6. taljemål

  1. Instruer deltageren til at stå oprejst, stadig, og sideværts til en stol, helst foran et spejl. Sid overfor spejlet, med deltagerens højre eller venstre hofte knogle i øjenhøjde. Instruer deltageren til at krydse hans / hendes arme foran, mens du holder op hans / hendes skjorte.
  2. Sidder på siden af ​​deltageren, find den forreste del af hoftebenet, som normalt er den del af hoftebenet, der er lettest identificeres gennem tætte fedtvæv. Palpere opad sammen hoftebenet at lokalisere hoftebenskammen, den overlegne højderyggen af ​​hoftebenet. Fortsæt med at palpere hoftebenskammen indtil den når skæringspunktet mellem det øverste punkt på hoftebenskammen og mid-aksillær linie (se afsnit 3.6 for at lokalisere medio aksillær linje). Identificer site med en selvklæbende mærkat.
  3. 6.2 gentages på den anden side af deltagerens krop.
  4. Mens deltageren står vinkelret påspejlet, anbring forsigtigt målebåndet rundt om taljen på toppen af ​​de to klistermærker med nul side (eller base) af målebåndet nedenfor. Brug spejlet som en guide, justere den, så det er på et niveau, vandret plan på tværs af forsiden, bagsiden og begge sider.
  5. Spænd båndet, uden at trække i huden. Da dette er en fin balance, starte med målebånd klemme huden lidt. Så langsomt løsne målebånd for at danne en jævn linie langs huden, så huden ikke længere er indsnævret. Placer målebåndet fast på huden uden cinching deltagerens taljen, så der er hverken huller i målebånd eller klemt hud.
  6. I slutningen af ​​deltagerens naturlige udånding, læse båndet til nærmeste tiendedel af en centimeter.
    BEMÆRK: Denne måling er mest effektivt udføres i nærværelse af spejle eller to forskningsassistenter. En forsker, alene, kan ikke observere korrekt placering af målebåndet på alle sideraf kroppen. Spejlene og / eller yderligere personale medlem kompensere for obstruerede områder, informere korrekt målebånd placering.

7. Hip Omkreds

  1. Instruer deltageren til at stå oprejst ved siden af ​​en stol, vinkelret på spejlet. Spørg deltageren at folde hans / hendes arme foran kroppen med fødderne presset sammen.
  2. Sid på siden af ​​deltageren og ansigt spejlet, så øjne er på niveau med deltagerens hofter.
  3. Placer målebåndet rundt om hofterne end let, tætsluttende kampene tøj. Forankre målebåndet ved den maksimale fremspring af ballerne. Juster tape, så det er i et vandret plan omkring kroppen. Hold målebåndet fast. I lighed med taljemålet, stramme målebåndet, så huden er klemt. Slip målebånd langsomt, indtil der er en jævn linje omkring målebånd.
  4. Hold målebåndet fast og blankt, læste foranstaltningen ment til nærmeste tiendedel cm.

8. Mid-Overarm omkreds (MUAC)

  1. Instruer deltageren til at løfte hans / hendes skjorteærmer til skulderhøjde, at sikre, at målingen er foretaget direkte på huden. Mens deltageren står placere hans / hendes højre arm, så den er bøjet i en 90 ° vinkel ved albuen med håndfladen opad og fingerspidserne peger lige frem.
  2. Stå bag deltageren. Find den posteriore laterale skulder knogle, der forbinder deltagerens skulderblad og kravebenet knogle (figur 3). Denne knoklet struktur, kendt som acromion proces, vil tjene som indledende punkt nul på målebåndet.

Figur 3
Figur 3: Anatomi af skulder. Skulder anatomi indbefatter acromion proces, der er konstateret i rødass = "xref"> 17. Klik her for at se en større version af dette tal.

  1. Forlæng båndet ned midterlinjen af ​​bagsiden af ​​armen, forbi den benede spidsen af ​​albuen, kendt som olecranon. Anvendes et bånd måle afstanden mellem acromion processen og olecranon til nærmeste tiendedel centimeter og placere en selvklæbende mærkat halvvejs mellem olecranon og acromion proces over den bageste midten af ​​humoristiske.
  2. Hold deltagerens arm lidt væk fra kroppen, for at sikre, at musklerne er afslappede.
  3. Stående til højre og lidt bag deltageren, pak MUAC Tape (lille, flip tape) omkring overarmen, så den dækker selvklæbende mærkat. Sikre, at målebåndet er vinkelret på armen længde.
  4. Træk båndet, så der er ingen huller i bånd eller områder af huden konstriktion. Som medhofte og arm omkreds, det er en fin balance. Brug større spænding og slip langsomt båndet, indtil der ikke er flere områder af klemt hud.
  5. Læs måling og optage til nærmeste tiendedel centimeter.

9. Triceps Skin Fold Tykkelse

  1. Brug mærkaten placering ved den bageste midtpunktet af deltagerens arm (som bestemt af trin 8.1 - 8.3). Instruer deltageren til at stå oprejst, med skuldre afslappede og arme hængende løst.
  2. Stående bag deltageren identificere en placering ca. 2 cm over mærkaten på overarmen midtpunktet. Gribe en anselig hudfold mellem tommel- og pegefinger omkring 1 - 2 cm ind i huden. Rul huden mellem fingrene.
    BEMÆRK: Hvis skinfold ruller let mellem fingrene, er det sandsynligvis kun indeholder hud og spæk. Hvis skinfold ikke nemt rulle eller greb er særligt smerteligt for deltageren, kan det indeholde muscle.
  3. Ryst huden og / eller roll fingre langsomt at justere klappen, så den kun indeholder hud og subkutane fedt, ikke muskler. Måle alle spæk over musklen.
  4. Hold skinfold parallelt med armen. Placer skinfold caliper kæbe vinkelret på længden af ​​folden og på hver side af den markerede midtpunkt.
  5. Mens du holder skinfold Slip helt greb om kaliberen håndtaget. Caliper dial fortsat vil falde som huden komprimeres af caliper kæber. Hold huden mellem caliper kæber til 4 fuld s, hvorefter huden bør helt sammenpresset. Efter 4 s, optage målingen til nærmeste to tiendedele af en centimeter.
    BEMÆRK: Hvis det er den korrekte mængde hud og subkutane væv, vil målingen (som læst på caliper dial) falde mindre hurtigt eller ikke vil falde på alle efter 4 s. Hvis målingen værdi på caliper skiven fortsætter med at falde hurtigt, har skinfold ikke indeholdenok subkutant fedt. Skulle dette være tilfældet, skal du vente to minutter for den komprimerede hud til at vende tilbage til normal. Gentag målingen ved at gribe en tykkere fold.

10. subscapular Skinfold Tykkelse

  1. Instruer deltageren til at stå oprejst, med skuldre afslappede og arme hængende løst.
  2. Stående bag deltageren, palpere den nederste spidsen af ​​bovbladet. Find målestedet, to centimeter under den nederste spidsen af ​​bovbladet, og placere caliperne der.
  3. Gribe en anselig hudfold mellem tommel- og pegefinger på en diagonal ca. 2 cm over og til venstre for målestedet. Huden bør let rulle mellem fingrene, hvis det indeholder kun hud og spæk. Juster skinfold, således at målingen kun indeholder hud og spæk.
  4. Placer caliper kæber vinkelret på målestedet, således at målingen foretages parallelt med den mediale, ringereknogle af skulderbladet. Mens du holder skinfold Slip helt greb om kaliberen håndtaget. Optag måling til de nærmeste to tiendedele af en cm efter 4 s.
  5. Sørg for, at kaliberen dial forbliver konsistent eller falder kun minimalt efter 4 s. Et hastigt faldende foranstaltning på kaliberen skiven viser, at der er opnået ikke nok subkutant fedt. Hvis dette er tilfældet, vente 2 min for den komprimerede hud for at vende tilbage til normal. Gentag målingen ved at gribe en tykkere fold.

11. kvalitetskontrol (QC) Procedurer

  1. Kræv alle medarbejdere, herunder erfarne og nye forskning medarbejdere, til at måle frivillige i løbet af QC sessioner. Få et lige antal frivillige og medarbejdere for at maksimere effektiviteten. Hvis studiet personale består af 1-3 personer, anmode mindst fire frivillige til at sikre, at pålidelighed er korrekt vurderet.
  2. Udpeg en person til at være den gyldne standard rater for QC-session, entenen kvalitet rater fra forskningen personale eller en ekstern ekspert. Sørg for, at han / hun har en dokumenteret pålidelighed (både intra-rater pålidelighed og pålidelighed i forhold til enten en faglært auxologist eller en guld standard, såsom DXA).
  3. Har alle undersøgelse medarbejdere gennemføre hver manuel antropometriske foranstaltning to eller flere gange på hver frivillig.
  4. Beregn intra-rater og inter-rater pålidelighed efter QC-session, ved hjælp af teknisk målefejl (TEM).
    BEMÆRK: TEM anvendes til at vurdere forskellen mellem to målinger, der kan henføres til målefejl 12. TEM er kvadratroden af ​​målefejl varians: TEM = ligning 1 , Hvor d 2 er enten forskellen mellem gentagne målinger af hver forskningsassistent (intra-rater pålidelighed) eller forskellen mellem summen af antropometri sagkyndiges replikater minus summen af en forskning hjælpeant s gentagelser (inter-rater pålidelighed) 12.
  5. Identificer ansatte, hvis inter- eller intra-rater TEM værdier falder uden for det forudbestemte TEM vifte af accept 14. Give mere uddannelse for ansatte, hvis antropometriske foranstaltninger falder uden for det acceptable område, forud for at lade indsamlingen feltdata fra undersøgelsens deltagere.

Subscription Required. Please recommend JoVE to your librarian.

Representative Results

Denne analyse omhandler præcision af de manuelle antropometriske målinger ved hjælp af data fra kvalitetskontrol (QC) procedurer, og evaluerer intra-rater målefejl ved Teknisk målefejl (TEM) 12. TEM intervaller af accept er baseret på beregninger af gentagne intra-rater antropometriske foranstaltninger, hvor 95% af måling uoverensstemmelsen skyldes andre end rater unøjagtighed 12, 14 faktorer. En højere TEM viser større variation blandt målinger. Acceptable målinger, som analyseres i forhold til TEM intervaller af accept, falder under eller inden TEM intervaller for det acceptable. Store TEM-værdier, der er TEM værdier over området, indikerer upålidelighed og angiver behov for yderligere uddannelse. I denne analyse præsenterer vi TEM værdier både i native enheder og procent TEM, beregnet ved (gennemsnitlig TEM / gennemsnit af denmåle) * 100, til at sammenligne på tværs af flere antropometriske foranstaltninger med forskellige enheder.

Tabel 1 viser intra-rater TEM værdier fra en QC-session Project Viva forskerhold udført på fem raske voksne kvindelige frivillige. Seks forskningsassistenter målte de frivillige gentagne gange for højst 60 gange pr antropometriske komponent. Hver kvinde forudsat 55 foranstaltninger, i gennemsnit. TEM værdier faldt inden for området af acceptable for hver foranstaltning og anfører lav variabilitet mellem målinger og dermed præcise teknik 12, 14. Videnskabelige assistenter mest præcist målt højde (% TEM = 0,2) efterfulgt af hofte omkreds (% TEM = 0,7). Videnskabelige assistenter var mindst præcis at måle subscapular skinfold tykkelse (% TEM = 7,4) og triceps skinfold tykkelse (% TEM = 6,9). To medlemmer af forskningspersonale opnåede TEM-værdier for taljen circumference, der var over intervallet acceptabilitet (TEM = 2,1; TEM = 3,0), signalering behov for efteruddannelse.

Data, der anvendes til beregning TEM værdier er vist i figur 4 og figur 5. Figur 4 viser alle højdemålinger opnået på QC-session er beskrevet ovenfor. Hver frivillig forudsat et gennemsnit på 11 højdemålinger. Højdemålinger varierede fra 151,4 cm til 166,4 cm blandt de fem frivillige. Individuel frivillige variation varierede fra 1,3 cm (for den frivillige repræsenteret i rød) til 4,1 cm (for den frivillige repræsenteret i orange) på tværs af alle seks raters. De fleste højdemålinger var inden 1,0 cm fra hinanden. Forskningen assistent repræsenteret ved cirkler var mindst præcise i måling højde, med flere perifere målinger. Denne signaler brug for mere uddannelse. Figur 5 viser alle subscapular skinfold tykkelse målinger opnået på QCsession. målinger skinfold tykkelse varierede fra 8,6 cm til 33,8 cm mellem de fem frivillige. Frivillige variation varierede fra 1,6 cm (for den frivillige repræsenteret i blåt) til 9,6 cm (for den frivillige repræsenteret i grønt). Forskning medarbejdere oplevede større inter-rater pålidelighed for subscapular skinfold tykkelse målinger end for højdemålinger.

Tabel 2 er tilpasset fra en tidligere analyse af Boeke et al. 1 om 1110 Projekt Viva deltagere målt i midten af barndommen (alder 6,5 - 10,9 år). Denne tabel adresser nøjagtighed af manuelle antropometriske målinger af kropsfedt, udtrykt som Spearman korrelationer med guld standard DXA foranstaltninger. DXA fedt var stærkt korreleret med alle manuelle antropometriske foranstaltninger, herunder vægt (r s = 0,80), taljemål (r s = 0,81), og summen af triceps + subscapular skinfold tykkelse (rs s = 0,47).

Figur 4
Figur 4: Scatterplot af højdemålinger. Højdemålinger (cm) taget af seks forskningsassistenter i QC-session på fem voksne kvindelige frivillige. Hver frivillig er repræsenteret af en anden farve. Hver forskningsassistent er repræsenteret af en anden form. Klik her for at se en større version af dette tal.

Figur 5
Figur 5: Scatterplot af subscapular skinfold Tykkelse Målinger. målinger subscapular skinfold tykkelse (cm) taget af seks forskningsassistenter i QCsession på fem voksne kvindelige frivillige. Hver frivillig er repræsenteret af en anden farve. Hver forskningsassistent er repræsenteret af en anden form. Klik her for at se en større version af dette tal.

Antal foranstaltninger Betyde TEM for hver af de 6 forskere Mean TEM acceptable % TEM
TEM interval [1]
1 2 3 4 5 6
Højde (cm) 55 160,4 0.2 0,3 0.4 0.4 0,1 0.5 0,3 0,1-1,3 0.2
Livvidde (cm) 54 77,1 2.1 3.0 0.4 0.4 0.4 1.5 1.3 1,0-1,6 1.9
Hip omkreds (cm) 54 99,2 0.5 1.1 0,8 0.2 0,6 0,6 0,6 1,2-1,4 0,7
Mid overarm omkreds (cm) 56 27,9 0,3 0.4 0.4 0.2 0.2 0,3 0,3 0 0,1-0,6 1.1
Subscapular skinfold tykkelse (mm) 56 14.5 0,8 0.9 0,7 0.4 0,1 0.9 0,6 0,1-7,4 7.4
Triceps skinfold tykkelse (mm) 55 16,7 0,7 0,7 1.2 0.9 0,1 1.9 0.9 0,1-3,7 6.9

Tabel 1: Intra-rater Pålidelighed (inden måler). Teknisk målefejl (TEM) for hver af de antropometriske foranstaltninger, inden for hver enkelt måler. Data fra seks Projekt Viva forskningsassistenter udfører gentagne foranstaltninger vedrørende fem voksne kvinder. TEM beregnet sombelastning / 54.895 / 54895eq2.jpg "/>, hvor d 2 er forskellen mellem gentagne målinger af hver forskning medarbejder (intra-rater pålidelighed) 12. En højere TEM viser større variation inden for de gentagne målinger indsamlet af den enkelte.% TEM beregnet som (gennemsnitlig TEM / gennemsnit af foranstaltningen) * 100.

Højde Vægt Vægt: BMI Talje circ SS + TR DXA fedt
(Cm) (Kg) Højde (kg / m2) (Cm) (Mm) (Kg)
N 1110 1110 1110 1110 1106 1103 875
Mean (SD) 128,8 (7,8) 29,0 (7,9) 0,22 (0,05) 17,2 (3,1) 60,0 (8,3) 19,9 (9,8) 7,5 (3,9)
Spearman korrelationskoefficient
Højde 1.00 0,80 0,66 0,38 0,56 0,33 0,47
Vægt 1.00 0,98 0,84 0,87 0,69 0,80
Vægt højde 1.00 0,93 0,90 0,75 0,84
BMI 1.00 0,86 0,79 0,83
Taljemål 1.00 0,73 0,81
SS + TR 1.00 0,90
DXA fedt 1.00

Tabel 2: Korrelationer mellem hver af flere Antropometriske foranstaltninger og med DXA kropsfedt blandt 1110 Projekt Viva Børn på 6,5 - 10,9 år. Tilpasset fra Boeke et al 1. BMI = body mass index; SS = subscapular skinfold; TR = triceps skinfold; DXA = dobbelt røntgen absorptiometri.

Subscription Required. Please recommend JoVE to your librarian.

Discussion

Nøjagtige kropssammensætning foranstaltninger er afgørende for korrekt vurdering af barndommen vækst i forskningsundersøgelser. Forskere bredt acceptere DXA som en gold standard metode, og mange kritiserer manuelle antropometriske foranstaltninger som værende upræcise og unøjagtige. Denne analyse af antropometriske teknikker til at estimere kropsfedt tyder dog på, at veluddannede forskningsassistenter, der følger en standardiseret protokol kan foretage manuelle antropometriske foranstaltninger med fremragende nøjagtighed, der giver fedme skøn, som er stærkt korreleret med DXA 1. Ud over individuelle foranstaltninger, kombinationer af manuelle antropometriske foranstaltninger, såsom summen af ​​skinfold tykkelse og vægt til højdeforhold, er stærkt korreleret med foranstaltninger af DXA kropsfedt. Formålet med denne protokol er at standardisere processer for otte almindeligt anvendte antropometriske foranstaltninger, for at forbedre nøjagtigheden og tillade sammenligning mellem undersøgelser og sammenlægning af resultater.

Præcis vurdering af kropssammensætning med manuel antropometri kræver tilstrækkelig tid til træning og gennemførelse af kvalitetskontrol procedurer for at sikre præcision og nøjagtighed. I betragtning af den ledende tid, der kræves, forskningsassistenter optimalt bør være til rådighed i mindst 24 måneder. Udstyr skal være robust og regelmæssigt kontrolleres for kalibrering. For at opnå et højt niveau af pålidelighed, skal raters følge alle trin i antropometriske protokol præcist, da selv små ændringer påvirker nøjagtighed. Udokumenterede tal viser, at forkert identifikation af anatomiske målesteder, hånd placering og tautness af måleudstyr forårsager den største variation mellem foranstaltninger. Med sans for detaljer, den vedlagte protokol giver en klar metode til indsamling præcise målinger men det viser også, at protokollen alene er utilstrækkelig til at opnå universelt nøjagtige resultater på området.

Lav intra-rater TEM-værdier opnås ved forskning medarbejdere, der afsluttede kort, men hård træning tyder på en høj grad af reproducerbarhed. Undervisere bør give yderligere uddannelse, men til forskning assistenter med TEM-værdier uden for intervallet accept for enhver måling. For at sikre at forskningsassistenter nå præcise foranstaltninger på alle praktikanter gennemgå en certificeringsproces. Praktikanter skal passere to felt QC vurderinger for at blive fuldt certificeret som antropometriske raters. I denne analyse, to bedømmere opnåede taljemål foranstaltninger uden for TEM vifte af acceptabilitet (som vist i tabel 1), således ikke passere certificeringsprocessen. Disse praktikanter modtaget yderligere supervision og træning før gentage deres QC vurderinger og uafhængig indsamling datafelt. Mens de skitserede QC procedurer giver generelle tillid til en researCH assistent evne, de ikke producere øjeblikkelig feedback på tidspunktet for feltet måling. En måde at overvinde denne begrænsning er at have to observatører hver udføre målingen om samme emne. Hvis tallene er forskellige, kan de forskningsassistenter tage yderligere målinger; data analytikere kan benytte middelværdien af ​​de to forskningsprojekter assistenternes foranstaltninger.

Begrænsninger af teknikken

Manuel antropometriske vurdering kræver tid og træning, med løbende overvågning af kvaliteten. Men andre metoder også kan kræve en betydelig uddannelse eller andre startomkostninger i tillæg til udgifterne til udstyret. For eksempel, Massachusetts (hvor Projekt Viva gennemføres) kræver, at nogen fører en DXA-scanning certificeres som en radiologisk teknolog eller autoriseret læge. Projekt Viva forskningsassistenter undersøgt for gennemsnitligt 60 timer for 3-h lang test, for hvilke registrering koster 425 $. Derudover manuel anthropometry kan ikke direkte vurdere visceralt fedt, i modsætning til nogle billeddannende teknikker.

Betydningen af ​​Teknik med Respekt for eksisterende / Alternative Metoder

Alle tilgange til måling kropssammensætning har fordele og ulemper. Manuel antropometri kan bruges på alle aldre, giver ingen risici, og har minimale omkostninger. Men succesen af ​​disse metoder afhænger af tilgængeligheden af ​​en stabil personale i stand til at tilbringe uger eller måneder fuldfører procedurerne uddannelse og til at følge protokoller præcist.

Fremtidige Programmer eller vejvisning

Med mindre ændringer, kan disse teknikker også tilpasses til andre antropometriske foranstaltninger, såsom liggende længde, og bryst og lår skinfolds. Sammenfattende dette papir viser, at med træning og QC, kan forskningsassistenter udføre manuelle antropometriske metoder til vurdering af adipositas hos børn med præcision og nøjagtighed. Tisse metoder er sikre, lave omkostninger, og kræver minimal, bærbart udstyr og er derfor velegnet til feltstudier blandt børn.

Subscription Required. Please recommend JoVE to your librarian.

Materials

Name Company Catalog Number Comments
Stadiometer Weigh and Measure, LLC  SSWM-1 Basic Shorr board (without smooth slide features) can also be used. In order to accommodate the width of children's hips during sitting height, the base of a stadiometer should be approximately 60 cm wide or larger.
Bioimpedance scale Tanita Coporation of America TBF 300A (model is discontinued), DC-430U is comparable Scale is used for weight and bioimpedance. Any digital, standardized scale can be used for weight only.
Skinfold Caliper Holtain Limited n/a This model uses a dial gauge in graduations of 0.2 mm. Models with a linear gauge are also acceptable.  
Hip/waist tape measure Gulick II Plus Measuring Tape 67019 This model uses compression bands, which makes it easier to identify how firmly the tape measure is being pulled. The compression band is not necessary, but highly recommended.
MUAC measuring tape (ShorrTape© Measuring Tape)  Weigh and Measure, LLC STape The tape measure should be flexible with a single or double slotted insertion window.

DOWNLOAD MATERIALS LIST

References

  1. Boeke, C. E., Oken, E., Kleinman, K. P., Rifas-Shiman, S. L., Taveras, E. M., Gillman, M. W. Correlations among adiposity measures in school-aged children. BMC Pediatrics. 13 (99), (2013).
  2. Ogden, C. L., Carroll, M. D., Kit, B. K., Flegal, K. M. Prevalence of childhood and adult obesity in the United States, 2011-2012. JAMA. 311 (8), 806-814 (2014).
  3. Erermis, S., Cetin, N., Tamar, M., Bukusoglu, N., Akdeniz, F., Goksen, D. Is obesity a risk factor for psychopathology among adolescents. Pediatr Int. 46 (3), 296-301 (2004).
  4. Gunnell, D., Frankel, S., Nachahal, K., Peters, T., Smith, G. Childhood obesity and adult cardiovascular mortality: A 57-y follow-up study based on the boyd orr cohort. AJCN. 67 (6), 1111-1118 (1998).
  5. Vanhala, M., Vanhala, P., Kumpusalo, E., Halonen, P., Takala, J. Relation between obesity from childhood to adulthood and the metabolic syndrome: Population based study. Brit Med J. 317 (7154), 319 (1998).
  6. Papoutsakis, C., Priftis, K. N., Drakouli, M., Prifti, S., Konstantaki, E., Chondronikola, M., Antonogeorgos, G., Matziou, V. Childhood overweight/obesity and asthma: is there a link? A systematic review of recent epidemiologic evidence. J Acad Nutr Diet. 113 (1), 77-105 (2013).
  7. Rifas-Shiman, S. L., Rich-Edwards, J. W., Scanlon, K. S., Kleinman, K. P., Gillman, M. W. Misdiagnosis of overweight and underweight children younger than 2 years of age due to length measurement bias. MedGenMed. 7 (4), 56 (2005).
  8. Horan, M., Gibney, E., Molloy, E., McAuliffe, F. Methodologies to assess paediatric adiposity. Ir J Med Sci. 814 (1), 1-16 (2014).
  9. Wells, J. C., Fewtrell, M. S. Measuring body composition. Arch Dis Child. 91 (7), 612-617 (2006).
  10. Wells, J. C., Fuller, N. J., Dewit, O., Fewtrell, M. S., Elia, M., Cole, T. J. Four-component model of body composition in children: Density and hydration of fat-free mass and comparison with simpler models. Am J Clin Nutr. 69 (5), 904-912 (1999).
  11. Damilakis, J., Adams, J. E., Guglielmi, G., Link, T. M. Radiation exposure in X-ray-based imaging techniques used in osteoporosis. Eur J Radiol. 20 (11), 2707-2714 (2010).
  12. Ulijaszek, S. J., Kerr, D. A. Anthropometric measurement error and the assessment of nutritional status. Brit J Nutr. 82 (3), 165-177 (1999).
  13. Oken, E., Baccarelli, A. A., Gold, D. R., Kleinman, K. P., Litonjua, A. A., DeMeo, D., Gillman, M. W. Cohort profile: Project Viva. Int J Epidemiol. 44 (1), 37-48 (2015).
  14. Ulijaszek, S. J., Lourie, J. A. Intra- and inter-observer error in anthropometric measurement. Anthropometry: the Individual and the Population. , Cambridge University Press. 30-55 (1994).
  15. Häggström, M. Medical gallery of Mikael Häggström 2014. Wikiversity Journal of. Medicine. 1 (2), (2014).
  16. Meredith, D. Male anatomy study face side. Flickr. , Available from: http://www.flickr.com (2007).
  17. Acromion of Scapula05. DBCLS. , BodyParts3D. Japan. (2013).

Tags

Medicin antropometri kropssammensætning adipositas Body Mass Index (BMI) Måling Pålidelighed Teknisk målefejl (TEM)
Vurdering af Child antropometri i en stor epidemiologisk undersøgelse
Play Video
PDF DOI DOWNLOAD MATERIALS LIST

Cite this Article

Louer, A. L., Simon, D. N.,More

Louer, A. L., Simon, D. N., Switkowski, K. M., Rifas-Shiman, S. L., Gillman, M. W., Oken, E. Assessment of Child Anthropometry in a Large Epidemiologic Study. J. Vis. Exp. (120), e54895, doi:10.3791/54895 (2017).

Less
Copy Citation Download Citation Reprints and Permissions
View Video

PLAYLIST

  • Research • Medicine
    Estimation of Urinary Nanocrystals in Humans using Calcium Fluorophore Labeling and Nanoparticle Tracking Analysis
  • Research • Medicine
    Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training
  • Research • Medicine
    Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
  • Research • Medicine
    Digital Handwriting Analysis of Characters in Chinese Patients with Mild Cognitive Impairment
  • Research • Medicine
    Segmentation and Linear Measurement for Body Composition Analysis using Slice-O-Matic and Horos
  • Research • Medicine
    Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
  • Research • Medicine
    Real-Time Magnetic Resonance Guided Focused Ultrasound for Painful Bone Metastases
  • Research • Medicine
    Isolation of Viable Adipocytes and Stromal Vascular Fraction from Human Visceral Adipose Tissue Suitable for RNA Analysis and Macrophage Phenotyping
  • Research • Medicine
    Obtaining Quality Extended Field-of-View Ultrasound Images of Skeletal Muscle to Measure Muscle Fascicle Length
  • Research • Medicine
    Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
  • Research • Medicine
    Electroretinogram Recording for Infants and Children under Anesthesia to Achieve Optimal Dark Adaptation and International Standards
  • Research • Medicine
    Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
  • Research • Medicine
    Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
  • Research • Medicine
    Simultaneous Laryngopharyngeal and Conventional Esophageal pH Monitoring
  • Research • Medicine
    Real-Time Monitoring of Neurocritical Patients with Diffuse Optical Spectroscopies
  • Research • Neuroscience
    Evaluating Postural Control and Lower-extremity Muscle Activation in Individuals with Chronic Ankle Instability
  • Research • Medicine
    Assessment of Dependence in Activities of Daily Living Among Older Patients in an Acute Care Unit
  • Research • Medicine
    Validated LC-MS/MS Panel for Quantifying 11 Drug-Resistant TB Medications in Small Hair Samples
  • Research • Medicine
    International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
  • Research • Biology
    A Finite Element Approach for Locating the Center of Resistance of Maxillary Teeth
  • Research • Medicine
    Lower Limb Biomechanical Analysis of Healthy Participants
  • Research • Neuroscience
    Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
  • Research • Medicine
    Oral Health Assessment by Lay Personnel for Older Adults
  • Research • Medicine
    Determining and Controlling External Power Output During Regular Handrim Wheelchair Propulsion
  • Research • Medicine
    A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
  • Research • Medicine
    Measurement of Carotenoids in Perifovea using the Macular Pigment Reflectometer
  • Research • Medicine
    Assessment of Static Graviceptive Perception in the Roll-Plane using the Subjective Visual Vertical Paradigm
  • Research • Medicine
    Learning Modern Laryngeal Surgery in a Dissection Laboratory
  • Research • Medicine
    DIPLOMA Approach for Standardized Pathology Assessment of Distal Pancreatectomy Specimens
  • Research • Medicine
    A Computerized Functional Skills Assessment and Training Program Targeting Technology Based Everyday Functional Skills
  • Research • Medicine
    Imaging Features of Systemic Sclerosis-Associated Interstitial Lung Disease
  • Research • Medicine
    Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
  • Research • Medicine
    Ultrasonographic Assessment During Cardiopulmonary Resuscitation
  • Research • Medicine
    Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
  • Research • Medicine
    Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
  • Research • Medicine
    Traditional Trail Making Test Modified into Brand-new Assessment Tools: Digital and Walking Trail Making Test
  • Research • Medicine
    Use of Magnetic Resonance Imaging and Biopsy Data to Guide Sampling Procedures for Prostate Cancer Biobanking
  • Research • Medicine
    A Fluorescence-based Assay for Characterization and Quantification of Lipid Droplet Formation in Human Intestinal Organoids
  • Research • Medicine
    A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
  • Research • Medicine
    Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
  • Research • Neuroscience
    Portable Thermographic Screening for Detection of Acute Wallenberg's Syndrome
  • Research • Medicine
    Use of MRI-ultrasound Fusion to Achieve Targeted Prostate Biopsy
  • Research • Medicine
    Testing of all Six Semicircular Canals with Video Head Impulse Test Systems
  • Research • Medicine
    Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
  • Research • Neuroscience
    Bilateral Assessment of the Corticospinal Pathways of the Ankle Muscles Using Navigated Transcranial Magnetic Stimulation
  • Research • Medicine
    Targeting Gray Rami Communicantes in Selective Chemical Lumbar Sympathectomy
  • Research • Medicine
    Multi-Modal Home Sleep Monitoring in Older Adults
  • Research • Medicine
    Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
  • Research • Medicine
    Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
  • Research • Medicine
    Measurements of Motor Function and Other Clinical Outcome Parameters in Ambulant Children with Duchenne Muscular Dystrophy
  • Research • Medicine
    Assessment of the Efficacy of An Osteopathic Treatment in Infants with Biomechanical Impairments to Suckling
  • Research • Medicine
    Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
  • Research • Medicine
    Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
  • Research • Medicine
    Generation of Human 3D Lung Tissue Cultures (3D-LTCs) for Disease Modeling
  • Research • Medicine
    Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
  • Research • Medicine
    Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
  • Research • Medicine
    Two-Dimensional X-Ray Angiography to Examine Fine Vascular Structure Using a Silicone Rubber Injection Compound
  • Research • Medicine
    Preparation, Procedures and Evaluation of Platelet-Rich Plasma Injection in the Treatment of Knee Osteoarthritis
  • Research • Medicine
    Cardiac Magnetic Resonance Imaging at 7 Tesla
  • Research • Medicine
    Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury
  • Research • Medicine
    Handheld Metal Detector Screening for Metallic Foreign Body Ingestion in Children
  • Research • Medicine
    Conducting Maximal and Submaximal Endurance Exercise Testing to Measure Physiological and Biological Responses to Acute Exercise in Humans
  • Research • Medicine
    A Metadata Extraction Approach for Clinical Case Reports to Enable Advanced Understanding of Biomedical Concepts
  • Research • Medicine
    Autonomic Function Following Concussion in Youth Athletes: An Exploration of Heart Rate Variability Using 24-hour Recording Methodology
  • Research • Medicine
    Hydra, a Computer-Based Platform for Aiding Clinicians in Cardiovascular Analysis and Diagnosis
  • Research • Medicine
    Objective Nociceptive Assessment in Ventilated ICU Patients: A Feasibility Study Using Pupillometry and the Nociceptive Flexion Reflex
  • Research • Medicine
    'Boden Food Plate': Novel Interactive Web-based Method for the Assessment of Dietary Intake
  • Research • Medicine
    Anogenital Distance and Perineal Measurements of the Pelvic Organ Prolapse (POP) Quantification System
  • Research • Medicine
    Bedside Ultrasound for Guiding Fluid Removal in Patients with Pulmonary Edema: The Reverse-FALLS Protocol
  • Research • Medicine
    Muscle Imbalances: Testing and Training Functional Eccentric Hamstring Strength in Athletic Populations
  • Research • Medicine
    Isolation of Primary Human Decidual Cells from the Fetal Membranes of Term Placentae
  • Research • Medicine
    Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
  • Research • Medicine
    Collecting Hair Samples for Hair Cortisol Analysis in African Americans
  • Research • Medicine
    In Vivo Morphometric Analysis of Human Cranial Nerves Using Magnetic Resonance Imaging in Menière's Disease Ears and Normal Hearing Ears
  • Research • Medicine
    Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
  • Research • Medicine
    Standardized Measurement of Nasal Membrane Transepithelial Potential Difference (NPD)
  • Research • Medicine
    Taste Exam: A Brief and Validated Test
  • Research • Medicine
    Absorption of Nasal and Bronchial Fluids: Precision Sampling of the Human Respiratory Mucosa and Laboratory Processing of Samples
  • Research • Medicine
    Methodology for Sputum Induction and Laboratory Processing
  • Research • Medicine
    Electrophysiological Measurement of Noxious-evoked Brain Activity in Neonates Using a Flat-tip Probe Coupled to Electroencephalography
  • Research • Medicine
    A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
  • Research • Medicine
    Oral Biofilm Sampling for Microbiome Analysis in Healthy Children
  • Research • Medicine
    Using Retinal Imaging to Study Dementia
  • Research • Medicine
    Application of an Amplitude-integrated EEG Monitor (Cerebral Function Monitor) to Neonates
  • Research • Medicine
    3D Ultrasound Imaging: Fast and Cost-effective Morphometry of Musculoskeletal Tissue
  • Research • Medicine
    The 4-vessel Sampling Approach to Integrative Studies of Human Placental Physiology In Vivo
  • Research • Medicine
    A Component-resolved Diagnostic Approach for a Study on Grass Pollen Allergens in Chinese Southerners with Allergic Rhinitis and/or Asthma
  • Research • Medicine
    A Novel Method: Super-selective Adrenal Venous Sampling
  • Research • Medicine
    A Method for Quantifying Upper Limb Performance in Daily Life Using Accelerometers
  • Research • Medicine
    Non-invasive Assessments of Subjective and Objective Recovery Characteristics Following an Exhaustive Jump Protocol
  • Research • Medicine
    Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
  • Research • Medicine
    Phosphorus-31 Magnetic Resonance Spectroscopy: A Tool for Measuring In Vivo Mitochondrial Oxidative Phosphorylation Capacity in Human Skeletal Muscle
  • Research • Medicine
    Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
  • Research • Medicine
    Assessment of Child Anthropometry in a Large Epidemiologic Study
  • Research • Medicine
    Video Movement Analysis Using Smartphones (ViMAS): A Pilot Study
  • Research • Medicine
    Network Analysis of Foramen Ovale Electrode Recordings in Drug-resistant Temporal Lobe Epilepsy Patients
  • Research • Medicine
    A Model to Simulate Clinically Relevant Hypoxia in Humans
  • Research • Medicine
    Interictal High Frequency Oscillations Detected with Simultaneous Magnetoencephalography and Electroencephalography as Biomarker of Pediatric Epilepsy
  • Research • Medicine
    Induction and Assessment of Exertional Skeletal Muscle Damage in Humans
  • Research • Medicine
    A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
  • Research • Medicine
    Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
  • Research • Medicine
    Integrated Compensatory Responses in a Human Model of Hemorrhage
  • Research • Medicine
    Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
  • Research • Medicine
    Impression Cytology of the Lid Wiper Area
  • Research • Behavior
    A Protocol of Manual Tests to Measure Sensation and Pain in Humans
  • Research • Medicine
    Unbiased Deep Sequencing of RNA Viruses from Clinical Samples
  • Research • Medicine
    A Choroid Plexus Epithelial Cell-based Model of the Human Blood-Cerebrospinal Fluid Barrier to Study Bacterial Infection from the Basolateral Side
  • Research • Medicine
    Isolation and Profiling of MicroRNA-containing Exosomes from Human Bile
  • Research • Medicine
    Generation of Microtumors Using 3D Human Biogel Culture System and Patient-derived Glioblastoma Cells for Kinomic Profiling and Drug Response Testing
  • Research • Medicine
    Ultrasound Assessment of Endothelial Function: A Technical Guideline of the Flow-mediated Dilation Test
  • Research • Medicine
    Using a Laminating Technique to Perform Confocal Microscopy of the Human Sclera
  • Research • Medicine
    Intravenous Endotoxin Challenge in Healthy Humans: An Experimental Platform to Investigate and Modulate Systemic Inflammation
  • Research • Medicine
    Modeling and Simulations of Olfactory Drug Delivery with Passive and Active Controls of Nasally Inhaled Pharmaceutical Aerosols
  • Research • Medicine
    Exosomal miRNA Analysis in Non-small Cell Lung Cancer (NSCLC) Patients' Plasma Through qPCR: A Feasible Liquid Biopsy Tool
  • Research • Medicine
    A Multimodal Imaging- and Stimulation-based Method of Evaluating Connectivity-related Brain Excitability in Patients with Epilepsy
  • Research • Medicine
    Measuring Cardiac Autonomic Nervous System (ANS) Activity in Toddlers - Resting and Developmental Challenges
  • Research • Medicine
    Using Saccadometry with Deep Brain Stimulation to Study Normal and Pathological Brain Function
  • Research • Medicine
    Quantitative Fundus Autofluorescence for the Evaluation of Retinal Diseases
  • Research • Medicine
    Diagnosis of Musculus Gastrocnemius Tightness - Key Factors for the Clinical Examination
  • Research • Medicine
    Stereo-Electro-Encephalo-Graphy (SEEG) With Robotic Assistance in the Presurgical Evaluation of Medical Refractory Epilepsy: A Technical Note
  • Research • Medicine
    Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
  • Research • Medicine
    Transcutaneous Microcirculatory Imaging in Preterm Neonates
  • Research • Medicine
    Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
  • Research • Medicine
    Design, Fabrication, and Administration of the Hand Active Sensation Test (HASTe)
  • Research • Medicine
    MRI-guided dmPFC-rTMS as a Treatment for Treatment-resistant Major Depressive Disorder
  • Research • Medicine
    Functional Human Liver Preservation and Recovery by Means of Subnormothermic Machine Perfusion
  • Research • Medicine
    A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
  • Research • Medicine
    Determining The Electromyographic Fatigue Threshold Following a Single Visit Exercise Test
  • Research • Medicine
    Use of Electromagnetic Navigational Transthoracic Needle Aspiration (E-TTNA) for Sampling of Lung Nodules
  • Research • Medicine
    Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
  • Research • Medicine
    In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
  • Research • Medicine
    Establishment of Human Epithelial Enteroids and Colonoids from Whole Tissue and Biopsy
  • Research • Medicine
    Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
  • Research • Medicine
    Preparation and Respirometric Assessment of Mitochondria Isolated from Skeletal Muscle Tissue Obtained by Percutaneous Needle Biopsy
  • Research • Medicine
    A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
  • Research • Medicine
    Isolation and Immortalization of Patient-derived Cell Lines from Muscle Biopsy for Disease Modeling
  • Research • Medicine
    State of the Art Cranial Ultrasound Imaging in Neonates
  • Research • Medicine
    Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
  • Research • Medicine
    The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
  • Research • Medicine
    Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
  • Research • Medicine
    Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
  • Research • Medicine
    A Neuroscientific Approach to the Examination of Concussions in Student-Athletes
  • Research • Medicine
    DTI of the Visual Pathway - White Matter Tracts and Cerebral Lesions
  • Research • Medicine
    Collection, Isolation, and Flow Cytometric Analysis of Human Endocervical Samples
  • Research • Medicine
    Fundus Photography as a Convenient Tool to Study Microvascular Responses to Cardiovascular Disease Risk Factors in Epidemiological Studies
  • Research • Medicine
    A Multi-Modal Approach to Assessing Recovery in Youth Athletes Following Concussion
  • Research • Medicine
    Clinical Assessment of Spatiotemporal Gait Parameters in Patients and Older Adults
  • Research • Medicine
    Multi-electrode Array Recordings of Human Epileptic Postoperative Cortical Tissue
  • Research • Medicine
    Collection and Extraction of Saliva DNA for Next Generation Sequencing
  • Research • Medicine
    Fast and Accurate Exhaled Breath Ammonia Measurement
  • Research • Medicine
    Developing Neuroimaging Phenotypes of the Default Mode Network in PTSD: Integrating the Resting State, Working Memory, and Structural Connectivity
  • Research • Medicine
    Two Methods for Establishing Primary Human Endometrial Stromal Cells from Hysterectomy Specimens
  • Research • Medicine
    Assessment of Vascular Function in Patients With Chronic Kidney Disease
  • Research • Medicine
    Coordinate Mapping of Hyolaryngeal Mechanics in Swallowing
  • Research • Medicine
    Network Analysis of the Default Mode Network Using Functional Connectivity MRI in Temporal Lobe Epilepsy
  • Research • Medicine
    EEG Mu Rhythm in Typical and Atypical Development
  • Research • Medicine
    The Multiple Sclerosis Performance Test (MSPT): An iPad-Based Disability Assessment Tool
  • Research • Medicine
    Isolation and Functional Characterization of Human Ventricular Cardiomyocytes from Fresh Surgical Samples
  • Research • Medicine
    Dynamic Visual Tests to Identify and Quantify Visual Damage and Repair Following Demyelination in Optic Neuritis Patients
  • Research • Medicine
    Primary Culture of Human Vestibular Schwannomas
  • Research • Medicine
    Utility of Dissociated Intrinsic Hand Muscle Atrophy in the Diagnosis of Amyotrophic Lateral Sclerosis
  • Research • Medicine
    Lesion Explorer: A Video-guided, Standardized Protocol for Accurate and Reliable MRI-derived Volumetrics in Alzheimer's Disease and Normal Elderly
  • Research • Medicine
    Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
  • Research • Medicine
    Isolation, Culture, and Imaging of Human Fetal Pancreatic Cell Clusters
  • Research • Medicine
    3D-Neuronavigation In Vivo Through a Patient's Brain During a Spontaneous Migraine Headache
  • Research • Medicine
    A Novel Application of Musculoskeletal Ultrasound Imaging
  • Research • Medicine
    Computerized Dynamic Posturography for Postural Control Assessment in Patients with Intermittent Claudication
  • Research • Medicine
    Collecting Saliva and Measuring Salivary Cortisol and Alpha-amylase in Frail Community Residing Older Adults via Family Caregivers
  • Research • Medicine
    Diffusion Tensor Magnetic Resonance Imaging in the Analysis of Neurodegenerative Diseases
  • Research • Medicine
    Transcriptomic Analysis of Human Retinal Surgical Specimens Using jouRNAl
  • Research • Medicine
    Improved Protocol For Laser Microdissection Of Human Pancreatic Islets From Surgical Specimens
  • Research • Medicine
    Evaluation of Respiratory Muscle Activation Using Respiratory Motor Control Assessment (RMCA) in Individuals with Chronic Spinal Cord Injury
  • Research • Medicine
    Minimal Erythema Dose (MED) Testing
  • Research • Medicine
    Measuring Cardiac Autonomic Nervous System (ANS) Activity in Children
  • Research • Medicine
    Collecting And Measuring Wound Exudate Biochemical Mediators In Surgical Wounds
  • Research • Medicine
    A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
  • Research • Medicine
    Using a Chemical Biopsy for Graft Quality Assessment
  • Research • Medicine
    Characterizing Exon Skipping Efficiency in DMD Patient Samples in Clinical Trials of Antisense Oligonucleotides
  • Research • Medicine
    In Vitro Assessment of Cardiac Function Using Skinned Cardiomyocytes
  • Research • Medicine
    Normothermic Ex Situ Heart Perfusion in Working Mode: Assessment of Cardiac Function and Metabolism
  • Research • Medicine
    Evaluation of Vascular Control Mechanisms Utilizing Video Microscopy of Isolated Resistance Arteries of Rats
  • Research • Medicine
    Bronchoalveolar Lavage (BAL) for Research; Obtaining Adequate Sample Yield
  • Research • Medicine
    Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
  • Research • Medicine
    Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
  • Research • Medicine
    Driving Simulation in the Clinic: Testing Visual Exploratory Behavior in Daily Life Activities in Patients with Visual Field Defects
  • Research • Medicine
    Isolation, Characterization and Comparative Differentiation of Human Dental Pulp Stem Cells Derived from Permanent Teeth by Using Two Different Methods
  • Research • Medicine
    Portable Intermodal Preferential Looking (IPL): Investigating Language Comprehension in Typically Developing Toddlers and Young Children with Autism
  • Research • Medicine
    Intraoperative Detection of Subtle Endometriosis: A Novel Paradigm for Detection and Treatment of Pelvic Pain Associated with the Loss of Peritoneal Integrity
  • Research • Medicine
    The Use of Primary Human Fibroblasts for Monitoring Mitochondrial Phenotypes in the Field of Parkinson's Disease
  • Research • Medicine
    Collection Protocol for Human Pancreas
  • Research • Medicine
    The α-test: Rapid Cell-free CD4 Enumeration Using Whole Saliva
  • Research • Medicine
    The Measurement and Treatment of Suppression in Amblyopia
  • Research • Medicine
    Corneal Donor Tissue Preparation for Endothelial Keratoplasty
  • Research • Medicine
    Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)
  • Research • Medicine
    Eye Tracking Young Children with Autism
  • Research • Medicine
    Doppler Optical Coherence Tomography of Retinal Circulation
  • Research • Medicine
    Utilizing Transcranial Magnetic Stimulation to Study the Human Neuromuscular System
  • Research • Medicine
    Detection and Genogrouping of Noroviruses from Children's Stools By Taqman One-step RT-PCR
  • Research • Medicine
    Method to Measure Tone of Axial and Proximal Muscle
  • Research • Medicine
    The Trier Social Stress Test Protocol for Inducing Psychological Stress
  • Research • Medicine
    Probing the Brain in Autism Using fMRI and Diffusion Tensor Imaging
  • Research • Medicine
    Multifocal Electroretinograms
  • Research • Medicine
    Isolation of Human Islets from Partially Pancreatectomized Patients
  • Research • Medicine
    Examining the Characteristics of Episodic Memory using Event-related Potentials in Patients with Alzheimer's Disease
  • Research • Medicine
    Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
  • Research • Medicine
    Manual Muscle Testing: A Method of Measuring Extremity Muscle Strength Applied to Critically Ill Patients
  • Research • Medicine
    Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
  • Research • Medicine
    A Protocol for Comprehensive Assessment of Bulbar Dysfunction in Amyotrophic Lateral Sclerosis (ALS)
  • Research • Medicine
    An Investigation of the Effects of Sports-related Concussion in Youth Using Functional Magnetic Resonance Imaging and the Head Impact Telemetry System
  • Research • Medicine
    Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies
  • Research • Medicine
    Methods to Quantify Pharmacologically Induced Alterations in Motor Function in Human Incomplete SCI
  • Research • Medicine
    Multispectral Real-time Fluorescence Imaging for Intraoperative Detection of the Sentinel Lymph Node in Gynecologic Oncology
  • Research • Medicine
    Technique to Collect Fungiform (Taste) Papillae from Human Tongue
  • Research • Medicine
    Assessing Endothelial Vasodilator Function with the Endo-PAT 2000
  • Research • Medicine
    Making Sense of Listening: The IMAP Test Battery
  • Research • Medicine
    An Experimental Paradigm for the Prediction of Post-Operative Pain (PPOP)
  • Research • Biology
    Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
  • Research • Biology
    Demonstration of Cutaneous Allodynia in Association with Chronic Pelvic Pain
  • Get cutting-edge science videos from JoVE sent straight to your inbox every month.

    Waiting X
    Simple Hit Counter