Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals

Published: June 8, 2017 doi: 10.3791/55485

Summary

We present a protocol to test the aerobic and anaerobic power of the upper body muscles over a duration of 3 min in able-bodied as well as in paraplegic and tetraplegic individuals. The protocol presents specific modifications in its application for upper-body exercise in individuals with or without disability.

Abstract

Reliable exercise protocols are required to test changes in exercise performance in elite athletes. Performance improvements in these athletes may be small; therefore, sensitive tools are fundamental to exercise physiology. There are currently many exercise tests that allow for the examination of exercise capacity in able-bodied athletes, with protocols mainly for lower-body or whole-body exercise. There is a trend to test athletes in a sport-specific setting that closely resembles the actions that the participants are used to performing. Only a few protocols test short-term, high-intensity exercise capacity in participants with an impairment of the lower body. Most of these protocols are very sport-specific and are not applicable to a wide range of athletes. One well-known test protocol is the 30 s Wingate test, which is well-established in cycling and in arm crank exercise testing. This test analyzes high-intensity exercise performance over a 30 s time duration. In order to monitor exercise performance over a longer duration, a different method was modified for application to the upper body. The 3 min, all-out arm crank ergometer test allows athletes to be tested in a manner specific to 1,500 m wheelchair racing (in terms of exercise duration), as well as to upper body exercises such as rowing or hand-cycling. In order to increase the reliability with identical test conditions, it is crucial to precisely replicate settings such as the resistance (i.e., torque factor) and the position of the participants (i.e., the height of the crank, the distance between the crank and the participant, and the fixation of the participant). Another important issue concerns the beginning of the exercise test. Fixed revolutions per minute are required to standardize the test conditions for the start of the exercise test. This exercise protocol shows the importance of accurate operations to reproduce identical test conditions and settings.

Introduction

There are several exercise tests that accurately determine the increase in exercise performance in elite athletes over the course of a training period1,2,3,4,5. One of these tests is the reliable 3-min all-out exercise test on a braked cycling ergometer3,4,5,6. This test was used to determine critical power, but it was also applied to exercise testing with athletes, as well as to research7,8,9. As this test was mainly used for lower-extremity performance, such as in rowing7 and cycling3,5, a similar testing protocol for upper-body exercise was needed. Sport disciplines that mainly use the upper body might be possible beneficiaries for such a new test protocol, in addition to athletes or individuals with an impairment of lower body muscles (e.g., an amputation or an impairment of limbs due to a spinal cord injury). Hence, a test protocol on the arm crank ergometer is a good tool to easily test upper-body exercise performance in a variety of athletes from different sport disciplines.

The existence of a very similar 30 s Wingate arm crank ergometer test10,11 helped with the development of a protocol for a 3 min, all-out arm crank ergometer test. Its duration is very similar to that of a 1,500 m wheelchair race. Therefore, this new test protocol of the 3 min, all-out arm crank ergometer test was tested for its test-retest reliability12. Overall, the reliability of this test protocol was excellent, so it could be a future testing tool in the field of upper-body exercise testing. Nevertheless, the use of this exercise test requires attention, especially when testing individuals with a spinal cord injury. Therefore, the aim of this experimental article is to demonstrate a detailed protocol that describes not only the test settings and analysis of the test results, but that also indicates the differences between testing able-bodied individuals and athletes with a spinal cord injury.

Subscription Required. Please recommend JoVE to your librarian.

Protocol

The study was approved by the local ethical committee (Ethikkommission Nordwest- und Zentralschweiz, Basel, Switzerland), and written informed consent was obtained from the participants before starting the study.

1. Test Preparation and Participant Instruction

  1. Arm crank ergometer
    1. Turn the power on the rotation speed-dependent arm crank ergometer before opening the software.
    2. Choose the test protocol for the 3 min, all-out ergometer test.
      1. Insert a new protocol with a 120 s warmup, 180 s of test duration, and a 720 s cooldown period. Choose this test protocol and open a new participant sheet.
    3. For every new test, determine the participant's body mass beforehand.
    4. Set the relative torque factor to 0.2 for able-bodied and paraplegic individuals (e.g., for a 100-kg participant with a relative torque factor of 0.2, a torque of 20 Nm results)12.
      1. Apply a lower torque factor for tetraplegic participants depending on the lesion level of the spinal cord injury; two or more familiarization trials are needed to determine the optimal relative torque factor for the relevant participant.
      2. Perform a familiarization trial in the same manner as described in section 2. If no peak appears after printing the data from the familiarization trial, or if the participant was not able to crank for the whole 3 min, perform a second familiarization trial with a lower torque factor. Give participants a rest of at least two days between each trial.
  2. Exercise test settings
    1. Adjust the height of the arm crank and record it to replicate identical test settings in the next test session. Adjust and record the distance between the arm crank ergometer and the participant.
      1. To determine the height, measure the distance between the floor and the fixation of the crank. To record the distance between the crank and the participant, measure and record the distance between the wall and the chair fixation. Adjust the arm crank axis to a height horizontal to the shoulder joint.
    2. Record either the distance between the wall fixation and the chair or the distance between the ergometer and the chair fixation. Adjust the chair settings according to whether the participant is a) able-bodied, b) paraplegic ,or c) tetraplegic.
      1. If the participant is able-bodied, have the participant sit in the chair provided by the distributor.
      2. If the participant is paraplegic and needs to sit in their own wheelchair, use a fixation set to fix the wheelchair to the arm crank ergometer. If the participant does not need their own wheelchair, have the participant sit in the chair provided by the distributor.
      3. If the participant is tetraplegic, fix their upper body to the chair provided by the distributor or to their own wheelchair and possibly fix their hands to the pedals. To fix the upper body, use a strap with hook-and-loop fastener. For hand fixation, use a wristband in tetraplegic patients.
  3. Additional measurements
    1. Make sure that the lactate system solution is refilled before using the lactate analyzer. Insert a new chip sensor every six months. Use the quality control solution (12 mM) every day and the 3 mM quality control solution every two weeks.
      1. Put the 12 mM quality control solution into the "STD 1" slot every morning.
      2. To further enhance the quality, add 3 mM quality control solutions into gap "1" and "2" and run a measurement by pressing "start" every two weeks. The measurement should result in a range between 2.96 and 3.10 mM.
    2. To determine the whole-blood lactate concentration before and after the 3 min, all-out arm crank ergometer test, obtain a baseline lactate concentration. Disinfect the earlobe with a disinfectant before drawing a blood sample from the earlobe using a 10 µL capillary. Use a lancet to get the whole blood sample.
      1. When the capillary is completely full of blood, put it into the hemolysis cup.
        NOTE: These cups are commercially available and prefilled with a hemolyzing solution. Shake the solution until the blood is completely mixed before putting it into the tray of the lactate analyzer.
      2. Run a calibration before analyzing the lactate concentration. Place the quality control cup into the lactate analyzer (see step 1.3.1.1.). Ensure that the calibration results in a 12-mM lactate concentration; otherwise, replace the chip sensor.
      3. Place the samples into the numbered slots, starting with "1" for the sample that was taken first.
        NOTE: After the calibration is completed, the samples are measured automatically by the chip sensor system.
    3. To determine the heartrate, place a heartrate belt around the chest of the participant and fix the heartrate monitor to the arm crank ergometer. Start the measurement by pressing on the red start button on the monitor. If no heartrate is displayed on the watch, wet the heartrate belt with water to ensure a good recording of the heartrate.
    4. To determine oxygen consumption during warmup and during the 3 min all-out test, calibrate the metabolic cart before the test. Run automatic volume and gas calibration immediately before the test and before putting the mask on.
      1. Open the automatic volume calibration in the software and press the start button. Store the results if the error is below 3% on the screen.
      2. Open the gas calibration in the software, as well as the calibration gas, and start with the automatic calibration.
        NOTE: The calibration gas consists of 5% CO2, 16% O2, and 79% N2. When 8 green buttons are displayed on the screen at the end of the calibration, the calibration is successful and the results can be stored. Close the gas bottle to ensure no leakage of gas.
      3. Ensure that the participant's actual body mass is inserted into the computer program. After the participant is chosen by the search engine on the computer, choose "ergospirometry" in the software and start with the measurement of room air concentration by pressing the start button.
      4. To run this calibration, take the sensor out of the spirometer and press the start button. Calibration is finished when "ok" is displayed on the computer.
      5. Meanwhile, during the calibration, put the oxygen mask on the participant.
      6. When the measurement of room air concentration is finished and the program is ready to measure, put the sensor back into the spirometer. Then, put the whole spirometer into the cavity of the mask; the device is now ready to measure oxygen consumption.
      7. In addition, fix the hose of the spirometer somewhere (e.g., on the shoulder with an adhesive tape) so that it does not interfere during the arm crank exercise.

2. Execution of the Exercise Protocol

  1. Warmup
    1. 1 min before starting the warmup, start measuring the oxygen consumption at rest when the participant sits at the arm crank ergometer without moving or talking. Press the start button in the software program.
    2. At the same time, start the measurement of the heartrate by pressing the red button. Measure the heartrate during the warmup, as well as during and after the test.
    3. Perform a standardized warmup over 2 min at 20 W before the start of the test. During the last 30 s of the warmup, keep the cadence constant at 60 rpm. Count down the last 10 s of the 30-s warmup.
  2. 3 min all-out exercise test
    1. At the end of the countdown, make sure to give a clear starting signal by shouting "go." After the start signal is given, allow the participant to accelerate.
    2. Instruct the participant to accelerate the arm crank ergometer to the maximum possible speed right at the beginning of the test. Keep the cadence at the maximum possible speed during the whole test. For standardization reasons, do not encourage the participants during the tests.
    3. Give information on duration every 30 s. Finish the test after a duration of 3 min.
  3. Cooldown and post analysis
    1. After finishing the 3 min all-out test, measure the end lactate concentration, if desired, and thereafter every 2 min for the next 10 min. Re-use the same puncture site for blood sampling as was used before the test.
    2. Stop the measurement of oxygen consumption after finishing these 3 min by pressing the stop button. Remove the oxygen mask. Save the measurement of oxygen consumption on the computer by pressing the exit button and by clicking "yes" when the software asks for data storage.
      NOTE: The data is stored in the software program and can easily be converted to a csv document later.
    3. To export the data, press the "Export" button to convert the file to a csv document for later analysis. Stop the heartrate measurement by pressing the stop button on the left side of the heartrate monitor after all blood samples have been drawn from the earlobe.

3. Data Analysis and Interpretation of the Results

  1. Performance parameters
    1. Analyze several different parameters after finishing this performance test.
      First, save the test and export it to a spreadsheet.
    2. Calculate the mean power (Pmean = EquationEquation over 3 min, the peak power, and the minimal power in between these 3-min12.
      NOTE: the peak power (Ppeak) is the maximal power during the whole 3 min. The power is measured in 0.2-s intervals. The peak power is the highest and the minimal power (Pmin) the lowest single-power measurement.
    3. Calculate the fatigue index as the power decline per second from the peak power to the end power ((Ppeak [W] – Pmin [W])/(tmin [s] – tpeak [s])).
    4. Calculate the total work over the whole 3 min by adding the work done every second (Work [J]= resistance [kg] * revolutions per min * flywheel distance [m] * time [min]).
    5. Calculate the time from the start to the peak power (time to peak power = tpeak [s]). Furthermore, calculate the relative peak (relative Ppeak = Ppeak/kg body mass) and the mean power (relative Pmean = Pmean/kg body mass) by dividing the absolute values by the body mass of the participant.
    6. Divide the 3-min all-out test into 30-s segments to check the pacing strategy and fatigue over these 3 min. Calculate the mean power for every 30-s segment (Pmean = EquationEquation.
  2. Other measurements
    1. Place all blood samples into the numbered slots of the blood lactate analyzer and run the measurements automatically by pressing "analyze." Print blood lactate concentrations for later analysis by turning on the printer.
    2. Transmit the heartrate measurements to the computer using an infrared device from the manufacturer. Open the software of the heartrate monitor and import the data from the heartrate monitor to the software. Store the data locally and, if desired, export it to a spreadsheet for later analysis (e.g., segment analysis)13.
    3. Set a marker right at the beginning of the 3 min and at the end of the 3 min, allowing the average, maximal, and minimal heartrate to be calculated automatically for this segment.
      NOTE: The heartrate is averaged automatically by the software over 5 s intervals.
    4. Export the data for oxygen consumption to a csv file (step 2.3) and open it in a spreadsheet for analysis14. Calculate the average oxygen consumption at rest: (VO2_rest = EquationEquation and during the 3 min (VO2_180s = EquationEquation, as well as the peak oxygen consumption and oxygen consumption during the 30-s segments: (VO2_30s = EquationEquation.
      NOTE: The data for oxygen consumption are measured breath-by-breath and then averaged automatically over a duration of 15 s per segment. The peak oxygen consumption is the highest value over a 15-s interval during the 3-min exercise test.
  3. Statistics
    1. Use the Shapiro-Wilk test, the Q-Q-plot, and the Kolmogorov Smirnov tests to check the normal distribution of the data. If the data is normally distributed, present it as the mean and the standard deviation (SD).
    2. Analyze the test-retest reliability using the intra-class correlation coefficient (ICC; 3,1 model)15.
    3. Calculate the absolute and relative reliability using the standard error of the measurement (SEM), coefficient of variation (CV), smallest real difference (SRD), and 95% confidence interval of the ICC16.
      NOTE: The ICC should be interpreted according to Munro`s classification17: 0.26 to 0.49 reflects a low correlation; 0.50 to 0.69 reflects a moderate correlation; 0.70 to 0.89 reflects a high correlation; and 0.90 to 1.0 indicates a very high correlation. The absolute reliability should be presented as the SRD, CV, and SEM, and the relative reliability should be in the form of the ICC16,18.
    4. Analyze significant changes between the two test sessions using a paired t-test. To show the agreement of the data sets of both test sessions, use Bland-Altman19 plots. Use statistical software to perform data analysis; set a statistical significance level of 0.05 throughout.

Subscription Required. Please recommend JoVE to your librarian.

Representative Results

The test-retest reliability was checked in 21 recreationally trained (but not specifically upper-body trained), non-smoking individuals (9 males, 12 females; age: 34 ± 11 years; body mass: 69.6 ± 11.1 kg; and height: 175.5 ± 6.9 cm). Table 1 shows the results for the relative and absolute test-retest reliabilities12. The peak power compared between the test and retest is presented in Figure 112. A Bland Altman plot for this test-retest is presented in Figure 212. Afterwards, this 3-min, all-out arm crank ergometer test was used in 17 able-bodied (age: 38 ± 7 years, height: 183 ± 13 cm, and body mass: 79 ± 6 kg), 10 paraplegic, and 7 tetraplegic participants (Table 2). Individual data representing an able-bodied as well as a tetraplegic participant are presented in Figure 3. Able-bodied participants showed a peak power of 483 ± 94 W, whereas paraplegic and tetraplegic participants were found to have a peak power of 375 ± 101 W and 98 ± 49 W, respectively. The mean power was found to be 172 ± 20 W, 157 ± 28 W, and 40 ± 14 W for able-bodied, paraplegic, and tetraplegic participants, respectively. Significant differences in mean and peak power were found between able-bodied and tetraplegic participants (p < 0.001), as well as between paraplegic and tetraplegic participants (p < 0.001). The end lactate concentration was 8.9 ± 2.4 mM in able-bodied participants, 10.6 ± 2.9 mM in paraplegic participants, and 4.0 ± 0.8 mM in tetraplegic participants. The average heartrate during the 3-min all-out test was 155 ± 9.2 bpm in able-bodied, 163 ± 6.2 bpm in paraplegic, and 113 ± 15.9 bpm in tetraplegic participants. Again, the heartrate of tetraplegic participants was significantly lower compared to paraplegic (p <0.001) as well as to able-bodied participants (p <0.001). The oxygen consumption measured during a 3-min all-out test is presented in Figure 4.

Figure 1
Figure 1: Mean power compared between the two 3-min all-out exercise tests on an arm crank ergometer12. The solid line represents the best fit and the dashed line the line of identity. Please click here to view a larger version of this figure.

Figure 2
Figure 2: Bland-Altman plot for peak power12. SD = standard deviation. Please click here to view a larger version of this figure.

Figure 3
Figure 3: Individual data of the 3-min all-out arm crank ergometer test for an able-bodied as well as a tetraplegic participant. Left = able-bodied participant; right = tetraplegic participant; blue line = power output; green line = cadence. Please click here to view a larger version of this figure.

Figure 4
Figure 4: Oxygen consumption during a 3 min all-out arm crank ergometer test in an able-bodied participant. Time point zero represents the start of the 3 min test. The data are presented as the raw data measured breath-by-breath.

ICC 95% CI SEM % SRD % CV
Peak power [W] 0.961 [0.907; 0.984] 2 5.6 6.66
Mean power [W] 0.984 [0.960; 0.993] 0.6 1.6 3.13
Minimal power [W] 0.964 [0.914; 0.985] 1.4 4 6.05
Time to peak [s] 0.379 [-0.052; 0.691] 22.5 62.4 11.37
Fatigue index  0.940 [0.858; 0.975] 3.6 9.9 9.43
Rel. peak power [W/kg] 0.922 [0.818; 0.968] 2.8 7.8 6.45
Rel. mean power [W/kg] 0.950 [0.882; 0.979] 1.1 3.2 3.46
Total work [J] 0.984 [0.960; 0.993] 0.6 1.6 3.13

Table 1: Test-retest reliability for all parameters12. ICC = intra-class correlation coefficient; CI = confident interval; SEM = standard error of the measurement; SRD = smallest real difference; CV = coefficient of variation; rel. = relative.

Paraplegic participant Lesion level AIS Age (y) Body mass (kg) Height (cm)
P01 Th12 A 47 80 184
P02 Th10 A 43 73 183
P03 Th11 A 55 72 174
P04 L1 A 26 64 150
P05 Th12 A 22 63 185
P06 L1 A 32 76 175
P07 Th11 A 59 80 178
P08 L1 A 35 63 165
P09 L4 A 44 78 176
P10 L1 A 48 80 185
Mean 41 73 176
SD 12.1 6.8 10.4
Tetraplegic participant Lesion level AIS Age (y) Body mass (kg) Height (cm)
T01 C5 A 24 85 188
T02 C7 A 31 60 180
T03 C7 A 40 60 168
T04 C7 A 31 80 190
T05 C5 A 43 80 176
T06 C6 A 56 74 170
T07 C5 A 65 75 190
Mean 41 73 180
SD 13.6 9.9 9.3

Table 2: Anthropometric data of paraplegic and tetraplegic participants. AIS = American Spinal Injury Association Impairment Scale, Th = thoracic, L = lumbar, C = cervical, SD = standard deviation.

Subscription Required. Please recommend JoVE to your librarian.

Discussion

Exercise testing in spinal-cord injured athletes is crucial to tracking exercise performance over several months or years of training. Only a few exercise tests exist to check short-term, high-intensity exercise performance on the arm crank ergometer. This method describes in detail how an exercise test that was already examined for its reliability in cycling5 and rowing7 might be applied to the arm crank ergometer. To collect reliable and meaningful results, two factors are very important: first, the preparation of the participant for this exercise test and second, the standardization of the test. Thus, the participant is instructed to enter the lab in a rested state, meaning no intense training during the two days prior to the test. Food intake (e.g., carbohydrate-rich nutrition 24 h prior testing) and sleep (e.g., at least 7 h of sleep during the two nights prior to testing) also need to be taken into account. Additionally, before performing the first "real" exercise test, a familiarization trial should be performed to ensure that the participant understands the test protocol. The second condition concerns the standardization of the test protocol, which includes the warmup, the start of the test, and the fixation strategies for the wheelchair and hands (step 1.2). These settings need to be kept identical for each test with the same person. Also, the height of the crank may influence the power output and oxygen consumption20. Additionally, the handgrip position might be clinically relevant in terms of shoulder pain following the exercise21. Furthermore, abdominal binding might influence respiratory function and oxygen transport22, but it seems to augment trunk stability and exercise performance23. Thus, it is best to record adjustments and fixations in detail to reproduce equivalent conditions in the following test.

The results in Figures 1 and 2 indicated that this 3 min, all-out arm crank test is reliable in able-bodied participants and can be used for research or exercise testing12. When comparing able-bodied, paraplegic, and tetraplegic participants with each other, differences between these three groups were found. Able-bodied and paraplegic participants showed very similar results for maximal and mean power, whereas tetraplegic participants performed with a significantly lower power output. Similar findings were shown when comparing the 30 s Wingate test for paraplegic participants11 with the one for tetraplegic participants10. Due to the different lesion levels of these spinal-cord injured participants, various muscles are affected by the impairment. Thus, with a higher lesion level (e.g., in tetraplegic participants), a less active muscle mass results in a lower power output (Table 2). To diminish the variability of the lesion, only individuals with a lesion level between cervical 5 (C5) and 7 (C7) and with a motor and sensory complete spinal cord injury were included to represent tetraplegic participants. Nevertheless, even between such participants, a high inter-individual variability can occur. Individuals with an injury below C5 only have Musculus (M.) biceps activated in the arms, whereas individuals with an injury below C7 show activity in M. biceps brachii, M. extensor radialis, and M. triceps arm muscles24. Therefore, even with very narrow inclusion criteria like the ones mentioned here, the group of participants was very inhomogeneous in terms of muscle function. Concerning paraplegic and able-bodied participants, one would expect a higher power output in able-bodied participants due to full trunk stability and unaffected respiratory muscle function. Our results did not show any significant differences in power output between these two groups, although able-bodied participants performed slightly better. This may have been because our able-bodied study participants were less trained compared to the paraplegic participants. It is possible that, even with lower trunk stability and lower respiratory function, the paraplegic participants were more adapted to arm cranking, which might have compensated for their disadvantages.

Even though this test protocol seems to be reliable in able-bodied individuals, test-retest reliability might be limited in tetraplegic individuals. The power output in tetraplegic participants showed a very high inter-individual variability, which might be explained by differences in muscle function and power (e.g., active muscle dependent on lesion level). Nevertheless, Jacobs, Johnson, Somarriba, and Carter showed a very high reliability in the shorter version of this test (30 s Wingate test) in tetraplegic athletes10. We assumed that the reliability might be good enough over a longer duration (i.e., 3 min in this protocol) but did not test it. The lack of a test-retest reliability investigation in individuals with a tetraplegia is a limitation. Thus, before using this test protocol in a group of individuals with tetraplegia, we recommend checking the reliability of the protocol first. Another limitation of the study involves the standardization of the fixation strategies in participants with a very low core stability (e.g., individuals with a high lesion level, such as in tetraplegia). To fix them to the chair, a strap must be bound around the chair and the participant. Thus, it can be be difficult to record the height of the strap and how tightly it was pulled. In a future study, it would be beneficial to test whether the tightness of such a strap influences the power output in the test protocol.

Nevertheless, this test is a good tool to test athletes from different sport disciplines involving upper-body exercise. Additionally, as the pacing strategy of going all-out right at the beginning of the test is predefined, no individual pacing strategy is present.

To conclude, this test seems to be a reliable tool to test exercise performance over a duration of 3 min and is similar to short-term, high-intensity exercise performance. A familiarization trial is needed before its application in athletes or in research investigations in order to minimize learning effects from test 1 to test 2. In addition, further research is needed to check test-retest reliability in participants or athletes with a tetraplegia.

Subscription Required. Please recommend JoVE to your librarian.

Disclosures

The authors have nothing to disclose.

Acknowledgments

We are grateful for the assistance from Martina Lienert and Fabienne Schaufelberger during exercise testing, as well as from P. D. Claudio Perret, PhD for his scientific advice.

Materials

Name Company Catalog Number Comments
Angio V2 arm crank ergometer Lode BV, Groningen, NL N/A arm crank ergometer
Lode Ergometry Manager Software Lode BV, Groningen, NL N/A Software
10 µl end-to-end capillary EKF-diagnostics GmbH, Barleben, Germany 0209-0100-005 Capillaries
haemolysis cup EKF-diagnostics GmbH, Barleben, Germany 0209-0100-006 hemolysis cup
lactate analyzer Biosen C line, EKF-diagnostics GmbH 5213-0051-6200 lactate analyzer
Heart rate monitor, Polar 610i Polar, Kempele, Finland P610i heart rate monitor
metabolic cart, Oxygen Pro Jaeger GmbH N/A metabolic cart
oxygen mask, Hans Rudolph Hans Rudolph Inc. , USA 113814 oxygen mask
statistical software, PSAW Software SPSS Inc., Chicago USA N/A statistical software
desinfectant, Soft-Zellin Hartmann GmbH, Austria 999979 desinfectant
Quality control cup, EasyCon Norm EKF-diagnostics GmbH, Barleben, Germany 0201-005.012P6 quality control
Quality control cup 3mmol/L EKF-diagnostics GmbH, Barleben, Germany 5130-6152 control cup
Chip sensor lactate analyzer EKF-diagnostics GmbH, Barleben, Germany 5206-3029 chip sensor
Lactate system solution EKF-diagnostics GmbH, Barleben, Germany 0201-0002-025 lactate system solution
lancet, Mediware Blutlanzetten medilab 54041 lancet
Calibration gas,  Jaeger GmbH 36-MC G020 calibration gas
chair provided by distributor (ergoselect) ergoline GmbH, Germany N/A chair provided by distributor

DOWNLOAD MATERIALS LIST

References

  1. Conconi, F., Ferrari, M., Ziglio, P. G., Droghetti, P., Codeca, L. Determination of the anaerobic threshold by a noninvasive field test in runners. J Appl Physiol. 52 (4), 869-873 (1982).
  2. Strupler, M., Mueller, G., Perret, C. Heart rate-based lactate minimum test: a reproducible method. Br J Sports Med. 43 (6), 432-436 (2009).
  3. Black, M. I., Durant, J., Jones, A. M., Vanhatalo, A. Critical power derived from a 3-min all-out test predicts 16.1-km road time-trial performance. Eur J Sport Sci. 14 (3), 217-223 (2014).
  4. Burnley, M., Doust, J. H., Vanhatalo, A. A 3-min all-out test to determine peak oxygen uptake and the maximal steady state. Med Sci Sports Exerc. 38 (11), 1995-2003 (2006).
  5. Vanhatalo, A., Doust, J. H., Burnley, M. A 3-min all-out cycling test is sensitive to a change in critical power. Med Sci Sports Exerc. 40 (9), 1693-1699 (2008).
  6. Johnson, T. M., Sexton, P. J., Placek, A. M., Murray, S. R., Pettitt, R. W. Reliability analysis of the 3-min all-out exercise test for cycle ergometry. Med Sci Sports Exerc. 43 (12), 2375-2380 (2011).
  7. Cheng, C. F., Yang, Y. S., Lin, H. M., Lee, C. L., Wang, C. Y. Determination of critical power in trained rowers using a three-minute all-out rowing test. Eur J Appl Physiol. 112 (4), 1251-1260 (2012).
  8. Fukuda, D. H., et al. Characterization of the work-time relationship during cross-country ski ergometry. Physiol Meas. 35 (1), 31-43 (2014).
  9. Vanhatalo, A., McNaughton, L. R., Siegler, J., Jones, A. M. Effect of induced alkalosis on the power-duration relationship of "all-out" exercise. Med. Sci. Sports Exerc. 42 (3), 563-570 (2010).
  10. Jacobs, P. L., Johnson, B., Somarriba, G. A., Carter, A. B. Reliability of upper extremity anaerobic power assessment in persons with tetraplegia. J Spinal Cord Med. 28 (2), 109-113 (2005).
  11. Jacobs, P. L., Mahoney, E. T., Johnson, B. Reliability of arm Wingate Anaerobic Testing in persons with complete paraplegia. J Spinal Cord Med. 26 (2), 141-144 (2003).
  12. Flueck, J. L., Lienert, M., Schaufelberger, F., Perret, C. Reliability of a 3-min all-out arm crank ergometer exercise test. Int J Sports Med. 36 (10), 809-813 (2015).
  13. Polar. S610i Series User's manual Polar. , Available from: http://support.polar.com/support_files/en/C225742500419A8A42256CA000399AA7/S610i%20USA%20GBR%20C.pdf (2016).
  14. Erich Jaeger GmbH. User Manual Oxycon Pro. , Jaeger GmbH. (2016).
  15. Shrout, P. E., Fleiss, J. L. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 86 (2), 420-428 (1979).
  16. Beckerman, H., et al. Smallest real difference, a link between reproducibility and responsiveness. Qual Life Res. 10 (7), 571-578 (2001).
  17. Plichta, S. B., Kelvin, E. A., Munro, B. H. Munro's statistical methods for health care research. , Wolters Kluwer. (2011).
  18. Atkinson, G., Nevill, A. M. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med. 26 (4), 217-238 (1998).
  19. Bland, J. M., Altman, D. G. Measuring agreement in method comparison studies. Stat Methods Med Res. 8 (2), 135-160 (1999).
  20. van Drongelen, S., Maas, J. C., Scheel-Sailer, A., Van Der Woude, L. H. Submaximal arm crank ergometry: Effects of crank axis positioning on mechanical efficiency, physiological strain and perceived discomfort. J. Med. Eng. Technol. 33 (2), 151-157 (2009).
  21. Bressel, E., Bressel, M., Marquez, M., Heise, G. D. The effect of handgrip position on upper extremity neuromuscular responses to arm cranking exercise. J. Electromyogr. Kinesiol. 11 (4), 291-298 (2001).
  22. West, C. R., Goosey-Tolfrey, V. L., Campbell, I. G., Romer, L. M. Effect of abdominal binding on respiratory mechanics during exercise in athletes with cervical spinal cord injury. J Appl Physiol (1985). 117 (1), 36-45 (2014).
  23. West, C. R., Campbell, I. G., Goosey-Tolfrey, V. L., Mason, B. S., Romer, L. M. Effects of abdominal binding on field-based exercise responses in Paralympic athletes with cervical spinal cord injury. J. Sci. Med. Sport. 17 (4), 351-355 (2014).
  24. Kirshblum, S. C., et al. International standards for neurological classification of spinal cord injury. J Spinal Cord Med. 34 (6), 535-546 (2011).

Tags

Keywords: Arm Crank Exercise Spinal Cord Injury Able-bodied Exercise Protocol Ergometer Test Torque Wheelchair Lactate Heart Rate Oxygen Consumption
Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
Play Video
PDF DOI DOWNLOAD MATERIALS LIST

Cite this Article

Flueck, J. L. Experimental ProtocolMore

Flueck, J. L. Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals. J. Vis. Exp. (124), e55485, doi:10.3791/55485 (2017).

Less
Copy Citation Download Citation Reprints and Permissions
View Video

PLAYLIST

  • Research • Medicine
    Estimation of Urinary Nanocrystals in Humans using Calcium Fluorophore Labeling and Nanoparticle Tracking Analysis
  • Research • Medicine
    Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training
  • Research • Medicine
    Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
  • Research • Medicine
    Digital Handwriting Analysis of Characters in Chinese Patients with Mild Cognitive Impairment
  • Research • Medicine
    Segmentation and Linear Measurement for Body Composition Analysis using Slice-O-Matic and Horos
  • Research • Medicine
    Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
  • Research • Medicine
    Real-Time Magnetic Resonance Guided Focused Ultrasound for Painful Bone Metastases
  • Research • Medicine
    Isolation of Viable Adipocytes and Stromal Vascular Fraction from Human Visceral Adipose Tissue Suitable for RNA Analysis and Macrophage Phenotyping
  • Research • Medicine
    Obtaining Quality Extended Field-of-View Ultrasound Images of Skeletal Muscle to Measure Muscle Fascicle Length
  • Research • Medicine
    Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
  • Research • Medicine
    Electroretinogram Recording for Infants and Children under Anesthesia to Achieve Optimal Dark Adaptation and International Standards
  • Research • Medicine
    Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
  • Research • Medicine
    Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
  • Research • Medicine
    Simultaneous Laryngopharyngeal and Conventional Esophageal pH Monitoring
  • Research • Medicine
    Real-Time Monitoring of Neurocritical Patients with Diffuse Optical Spectroscopies
  • Research • Neuroscience
    Evaluating Postural Control and Lower-extremity Muscle Activation in Individuals with Chronic Ankle Instability
  • Research • Medicine
    Assessment of Dependence in Activities of Daily Living Among Older Patients in an Acute Care Unit
  • Research • Medicine
    Validated LC-MS/MS Panel for Quantifying 11 Drug-Resistant TB Medications in Small Hair Samples
  • Research • Medicine
    International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
  • Research • Biology
    A Finite Element Approach for Locating the Center of Resistance of Maxillary Teeth
  • Research • Medicine
    Lower Limb Biomechanical Analysis of Healthy Participants
  • Research • Neuroscience
    Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
  • Research • Medicine
    Oral Health Assessment by Lay Personnel for Older Adults
  • Research • Medicine
    Determining and Controlling External Power Output During Regular Handrim Wheelchair Propulsion
  • Research • Medicine
    A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
  • Research • Medicine
    Measurement of Carotenoids in Perifovea using the Macular Pigment Reflectometer
  • Research • Medicine
    Assessment of Static Graviceptive Perception in the Roll-Plane using the Subjective Visual Vertical Paradigm
  • Research • Medicine
    Learning Modern Laryngeal Surgery in a Dissection Laboratory
  • Research • Medicine
    DIPLOMA Approach for Standardized Pathology Assessment of Distal Pancreatectomy Specimens
  • Research • Medicine
    A Computerized Functional Skills Assessment and Training Program Targeting Technology Based Everyday Functional Skills
  • Research • Medicine
    Imaging Features of Systemic Sclerosis-Associated Interstitial Lung Disease
  • Research • Medicine
    Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
  • Research • Medicine
    Ultrasonographic Assessment During Cardiopulmonary Resuscitation
  • Research • Medicine
    Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
  • Research • Medicine
    Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
  • Research • Medicine
    Traditional Trail Making Test Modified into Brand-new Assessment Tools: Digital and Walking Trail Making Test
  • Research • Medicine
    Use of Magnetic Resonance Imaging and Biopsy Data to Guide Sampling Procedures for Prostate Cancer Biobanking
  • Research • Medicine
    A Fluorescence-based Assay for Characterization and Quantification of Lipid Droplet Formation in Human Intestinal Organoids
  • Research • Medicine
    A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
  • Research • Medicine
    Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
  • Research • Neuroscience
    Portable Thermographic Screening for Detection of Acute Wallenberg's Syndrome
  • Research • Medicine
    Use of MRI-ultrasound Fusion to Achieve Targeted Prostate Biopsy
  • Research • Medicine
    Testing of all Six Semicircular Canals with Video Head Impulse Test Systems
  • Research • Medicine
    Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
  • Research • Neuroscience
    Bilateral Assessment of the Corticospinal Pathways of the Ankle Muscles Using Navigated Transcranial Magnetic Stimulation
  • Research • Medicine
    Targeting Gray Rami Communicantes in Selective Chemical Lumbar Sympathectomy
  • Research • Medicine
    Multi-Modal Home Sleep Monitoring in Older Adults
  • Research • Medicine
    Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
  • Research • Medicine
    Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
  • Research • Medicine
    Measurements of Motor Function and Other Clinical Outcome Parameters in Ambulant Children with Duchenne Muscular Dystrophy
  • Research • Medicine
    Assessment of the Efficacy of An Osteopathic Treatment in Infants with Biomechanical Impairments to Suckling
  • Research • Medicine
    Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
  • Research • Medicine
    Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
  • Research • Medicine
    Generation of Human 3D Lung Tissue Cultures (3D-LTCs) for Disease Modeling
  • Research • Medicine
    Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
  • Research • Medicine
    Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
  • Research • Medicine
    Two-Dimensional X-Ray Angiography to Examine Fine Vascular Structure Using a Silicone Rubber Injection Compound
  • Research • Medicine
    Preparation, Procedures and Evaluation of Platelet-Rich Plasma Injection in the Treatment of Knee Osteoarthritis
  • Research • Medicine
    Cardiac Magnetic Resonance Imaging at 7 Tesla
  • Research • Medicine
    Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury
  • Research • Medicine
    Handheld Metal Detector Screening for Metallic Foreign Body Ingestion in Children
  • Research • Medicine
    Conducting Maximal and Submaximal Endurance Exercise Testing to Measure Physiological and Biological Responses to Acute Exercise in Humans
  • Research • Medicine
    A Metadata Extraction Approach for Clinical Case Reports to Enable Advanced Understanding of Biomedical Concepts
  • Research • Medicine
    Autonomic Function Following Concussion in Youth Athletes: An Exploration of Heart Rate Variability Using 24-hour Recording Methodology
  • Research • Medicine
    Hydra, a Computer-Based Platform for Aiding Clinicians in Cardiovascular Analysis and Diagnosis
  • Research • Medicine
    Objective Nociceptive Assessment in Ventilated ICU Patients: A Feasibility Study Using Pupillometry and the Nociceptive Flexion Reflex
  • Research • Medicine
    'Boden Food Plate': Novel Interactive Web-based Method for the Assessment of Dietary Intake
  • Research • Medicine
    Anogenital Distance and Perineal Measurements of the Pelvic Organ Prolapse (POP) Quantification System
  • Research • Medicine
    Bedside Ultrasound for Guiding Fluid Removal in Patients with Pulmonary Edema: The Reverse-FALLS Protocol
  • Research • Medicine
    Muscle Imbalances: Testing and Training Functional Eccentric Hamstring Strength in Athletic Populations
  • Research • Medicine
    Isolation of Primary Human Decidual Cells from the Fetal Membranes of Term Placentae
  • Research • Medicine
    Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
  • Research • Medicine
    Collecting Hair Samples for Hair Cortisol Analysis in African Americans
  • Research • Medicine
    In Vivo Morphometric Analysis of Human Cranial Nerves Using Magnetic Resonance Imaging in Menière's Disease Ears and Normal Hearing Ears
  • Research • Medicine
    Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
  • Research • Medicine
    Standardized Measurement of Nasal Membrane Transepithelial Potential Difference (NPD)
  • Research • Medicine
    Taste Exam: A Brief and Validated Test
  • Research • Medicine
    Absorption of Nasal and Bronchial Fluids: Precision Sampling of the Human Respiratory Mucosa and Laboratory Processing of Samples
  • Research • Medicine
    Methodology for Sputum Induction and Laboratory Processing
  • Research • Medicine
    Electrophysiological Measurement of Noxious-evoked Brain Activity in Neonates Using a Flat-tip Probe Coupled to Electroencephalography
  • Research • Medicine
    A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
  • Research • Medicine
    Oral Biofilm Sampling for Microbiome Analysis in Healthy Children
  • Research • Medicine
    Using Retinal Imaging to Study Dementia
  • Research • Medicine
    Application of an Amplitude-integrated EEG Monitor (Cerebral Function Monitor) to Neonates
  • Research • Medicine
    3D Ultrasound Imaging: Fast and Cost-effective Morphometry of Musculoskeletal Tissue
  • Research • Medicine
    The 4-vessel Sampling Approach to Integrative Studies of Human Placental Physiology In Vivo
  • Research • Medicine
    A Component-resolved Diagnostic Approach for a Study on Grass Pollen Allergens in Chinese Southerners with Allergic Rhinitis and/or Asthma
  • Research • Medicine
    A Novel Method: Super-selective Adrenal Venous Sampling
  • Research • Medicine
    A Method for Quantifying Upper Limb Performance in Daily Life Using Accelerometers
  • Research • Medicine
    Non-invasive Assessments of Subjective and Objective Recovery Characteristics Following an Exhaustive Jump Protocol
  • Research • Medicine
    Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
  • Research • Medicine
    Phosphorus-31 Magnetic Resonance Spectroscopy: A Tool for Measuring In Vivo Mitochondrial Oxidative Phosphorylation Capacity in Human Skeletal Muscle
  • Research • Medicine
    Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
  • Research • Medicine
    Assessment of Child Anthropometry in a Large Epidemiologic Study
  • Research • Medicine
    Video Movement Analysis Using Smartphones (ViMAS): A Pilot Study
  • Research • Medicine
    Network Analysis of Foramen Ovale Electrode Recordings in Drug-resistant Temporal Lobe Epilepsy Patients
  • Research • Medicine
    A Model to Simulate Clinically Relevant Hypoxia in Humans
  • Research • Medicine
    Interictal High Frequency Oscillations Detected with Simultaneous Magnetoencephalography and Electroencephalography as Biomarker of Pediatric Epilepsy
  • Research • Medicine
    Induction and Assessment of Exertional Skeletal Muscle Damage in Humans
  • Research • Medicine
    A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
  • Research • Medicine
    Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
  • Research • Medicine
    Integrated Compensatory Responses in a Human Model of Hemorrhage
  • Research • Medicine
    Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
  • Research • Medicine
    Impression Cytology of the Lid Wiper Area
  • Research • Behavior
    A Protocol of Manual Tests to Measure Sensation and Pain in Humans
  • Research • Medicine
    Unbiased Deep Sequencing of RNA Viruses from Clinical Samples
  • Research • Medicine
    A Choroid Plexus Epithelial Cell-based Model of the Human Blood-Cerebrospinal Fluid Barrier to Study Bacterial Infection from the Basolateral Side
  • Research • Medicine
    Isolation and Profiling of MicroRNA-containing Exosomes from Human Bile
  • Research • Medicine
    Generation of Microtumors Using 3D Human Biogel Culture System and Patient-derived Glioblastoma Cells for Kinomic Profiling and Drug Response Testing
  • Research • Medicine
    Ultrasound Assessment of Endothelial Function: A Technical Guideline of the Flow-mediated Dilation Test
  • Research • Medicine
    Using a Laminating Technique to Perform Confocal Microscopy of the Human Sclera
  • Research • Medicine
    Intravenous Endotoxin Challenge in Healthy Humans: An Experimental Platform to Investigate and Modulate Systemic Inflammation
  • Research • Medicine
    Modeling and Simulations of Olfactory Drug Delivery with Passive and Active Controls of Nasally Inhaled Pharmaceutical Aerosols
  • Research • Medicine
    Exosomal miRNA Analysis in Non-small Cell Lung Cancer (NSCLC) Patients' Plasma Through qPCR: A Feasible Liquid Biopsy Tool
  • Research • Medicine
    A Multimodal Imaging- and Stimulation-based Method of Evaluating Connectivity-related Brain Excitability in Patients with Epilepsy
  • Research • Medicine
    Measuring Cardiac Autonomic Nervous System (ANS) Activity in Toddlers - Resting and Developmental Challenges
  • Research • Medicine
    Using Saccadometry with Deep Brain Stimulation to Study Normal and Pathological Brain Function
  • Research • Medicine
    Quantitative Fundus Autofluorescence for the Evaluation of Retinal Diseases
  • Research • Medicine
    Diagnosis of Musculus Gastrocnemius Tightness - Key Factors for the Clinical Examination
  • Research • Medicine
    Stereo-Electro-Encephalo-Graphy (SEEG) With Robotic Assistance in the Presurgical Evaluation of Medical Refractory Epilepsy: A Technical Note
  • Research • Medicine
    Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
  • Research • Medicine
    Transcutaneous Microcirculatory Imaging in Preterm Neonates
  • Research • Medicine
    Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
  • Research • Medicine
    Design, Fabrication, and Administration of the Hand Active Sensation Test (HASTe)
  • Research • Medicine
    MRI-guided dmPFC-rTMS as a Treatment for Treatment-resistant Major Depressive Disorder
  • Research • Medicine
    Functional Human Liver Preservation and Recovery by Means of Subnormothermic Machine Perfusion
  • Research • Medicine
    A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
  • Research • Medicine
    Determining The Electromyographic Fatigue Threshold Following a Single Visit Exercise Test
  • Research • Medicine
    Use of Electromagnetic Navigational Transthoracic Needle Aspiration (E-TTNA) for Sampling of Lung Nodules
  • Research • Medicine
    Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
  • Research • Medicine
    In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
  • Research • Medicine
    Establishment of Human Epithelial Enteroids and Colonoids from Whole Tissue and Biopsy
  • Research • Medicine
    Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
  • Research • Medicine
    Preparation and Respirometric Assessment of Mitochondria Isolated from Skeletal Muscle Tissue Obtained by Percutaneous Needle Biopsy
  • Research • Medicine
    A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
  • Research • Medicine
    Isolation and Immortalization of Patient-derived Cell Lines from Muscle Biopsy for Disease Modeling
  • Research • Medicine
    State of the Art Cranial Ultrasound Imaging in Neonates
  • Research • Medicine
    Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
  • Research • Medicine
    The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
  • Research • Medicine
    Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
  • Research • Medicine
    Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
  • Research • Medicine
    A Neuroscientific Approach to the Examination of Concussions in Student-Athletes
  • Research • Medicine
    DTI of the Visual Pathway - White Matter Tracts and Cerebral Lesions
  • Research • Medicine
    Collection, Isolation, and Flow Cytometric Analysis of Human Endocervical Samples
  • Research • Medicine
    Fundus Photography as a Convenient Tool to Study Microvascular Responses to Cardiovascular Disease Risk Factors in Epidemiological Studies
  • Research • Medicine
    A Multi-Modal Approach to Assessing Recovery in Youth Athletes Following Concussion
  • Research • Medicine
    Clinical Assessment of Spatiotemporal Gait Parameters in Patients and Older Adults
  • Research • Medicine
    Multi-electrode Array Recordings of Human Epileptic Postoperative Cortical Tissue
  • Research • Medicine
    Collection and Extraction of Saliva DNA for Next Generation Sequencing
  • Research • Medicine
    Fast and Accurate Exhaled Breath Ammonia Measurement
  • Research • Medicine
    Developing Neuroimaging Phenotypes of the Default Mode Network in PTSD: Integrating the Resting State, Working Memory, and Structural Connectivity
  • Research • Medicine
    Two Methods for Establishing Primary Human Endometrial Stromal Cells from Hysterectomy Specimens
  • Research • Medicine
    Assessment of Vascular Function in Patients With Chronic Kidney Disease
  • Research • Medicine
    Coordinate Mapping of Hyolaryngeal Mechanics in Swallowing
  • Research • Medicine
    Network Analysis of the Default Mode Network Using Functional Connectivity MRI in Temporal Lobe Epilepsy
  • Research • Medicine
    EEG Mu Rhythm in Typical and Atypical Development
  • Research • Medicine
    The Multiple Sclerosis Performance Test (MSPT): An iPad-Based Disability Assessment Tool
  • Research • Medicine
    Isolation and Functional Characterization of Human Ventricular Cardiomyocytes from Fresh Surgical Samples
  • Research • Medicine
    Dynamic Visual Tests to Identify and Quantify Visual Damage and Repair Following Demyelination in Optic Neuritis Patients
  • Research • Medicine
    Primary Culture of Human Vestibular Schwannomas
  • Research • Medicine
    Utility of Dissociated Intrinsic Hand Muscle Atrophy in the Diagnosis of Amyotrophic Lateral Sclerosis
  • Research • Medicine
    Lesion Explorer: A Video-guided, Standardized Protocol for Accurate and Reliable MRI-derived Volumetrics in Alzheimer's Disease and Normal Elderly
  • Research • Medicine
    Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
  • Research • Medicine
    Isolation, Culture, and Imaging of Human Fetal Pancreatic Cell Clusters
  • Research • Medicine
    3D-Neuronavigation In Vivo Through a Patient's Brain During a Spontaneous Migraine Headache
  • Research • Medicine
    A Novel Application of Musculoskeletal Ultrasound Imaging
  • Research • Medicine
    Computerized Dynamic Posturography for Postural Control Assessment in Patients with Intermittent Claudication
  • Research • Medicine
    Collecting Saliva and Measuring Salivary Cortisol and Alpha-amylase in Frail Community Residing Older Adults via Family Caregivers
  • Research • Medicine
    Diffusion Tensor Magnetic Resonance Imaging in the Analysis of Neurodegenerative Diseases
  • Research • Medicine
    Transcriptomic Analysis of Human Retinal Surgical Specimens Using jouRNAl
  • Research • Medicine
    Improved Protocol For Laser Microdissection Of Human Pancreatic Islets From Surgical Specimens
  • Research • Medicine
    Evaluation of Respiratory Muscle Activation Using Respiratory Motor Control Assessment (RMCA) in Individuals with Chronic Spinal Cord Injury
  • Research • Medicine
    Minimal Erythema Dose (MED) Testing
  • Research • Medicine
    Measuring Cardiac Autonomic Nervous System (ANS) Activity in Children
  • Research • Medicine
    Collecting And Measuring Wound Exudate Biochemical Mediators In Surgical Wounds
  • Research • Medicine
    A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
  • Research • Medicine
    Using a Chemical Biopsy for Graft Quality Assessment
  • Research • Medicine
    Characterizing Exon Skipping Efficiency in DMD Patient Samples in Clinical Trials of Antisense Oligonucleotides
  • Research • Medicine
    In Vitro Assessment of Cardiac Function Using Skinned Cardiomyocytes
  • Research • Medicine
    Normothermic Ex Situ Heart Perfusion in Working Mode: Assessment of Cardiac Function and Metabolism
  • Research • Medicine
    Evaluation of Vascular Control Mechanisms Utilizing Video Microscopy of Isolated Resistance Arteries of Rats
  • Research • Medicine
    Bronchoalveolar Lavage (BAL) for Research; Obtaining Adequate Sample Yield
  • Research • Medicine
    Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
  • Research • Medicine
    Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
  • Research • Medicine
    Driving Simulation in the Clinic: Testing Visual Exploratory Behavior in Daily Life Activities in Patients with Visual Field Defects
  • Research • Medicine
    Isolation, Characterization and Comparative Differentiation of Human Dental Pulp Stem Cells Derived from Permanent Teeth by Using Two Different Methods
  • Research • Medicine
    Portable Intermodal Preferential Looking (IPL): Investigating Language Comprehension in Typically Developing Toddlers and Young Children with Autism
  • Research • Medicine
    Intraoperative Detection of Subtle Endometriosis: A Novel Paradigm for Detection and Treatment of Pelvic Pain Associated with the Loss of Peritoneal Integrity
  • Research • Medicine
    The Use of Primary Human Fibroblasts for Monitoring Mitochondrial Phenotypes in the Field of Parkinson's Disease
  • Research • Medicine
    Collection Protocol for Human Pancreas
  • Research • Medicine
    The α-test: Rapid Cell-free CD4 Enumeration Using Whole Saliva
  • Research • Medicine
    The Measurement and Treatment of Suppression in Amblyopia
  • Research • Medicine
    Corneal Donor Tissue Preparation for Endothelial Keratoplasty
  • Research • Medicine
    Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)
  • Research • Medicine
    Eye Tracking Young Children with Autism
  • Research • Medicine
    Doppler Optical Coherence Tomography of Retinal Circulation
  • Research • Medicine
    Utilizing Transcranial Magnetic Stimulation to Study the Human Neuromuscular System
  • Research • Medicine
    Detection and Genogrouping of Noroviruses from Children's Stools By Taqman One-step RT-PCR
  • Research • Medicine
    Method to Measure Tone of Axial and Proximal Muscle
  • Research • Medicine
    The Trier Social Stress Test Protocol for Inducing Psychological Stress
  • Research • Medicine
    Probing the Brain in Autism Using fMRI and Diffusion Tensor Imaging
  • Research • Medicine
    Multifocal Electroretinograms
  • Research • Medicine
    Isolation of Human Islets from Partially Pancreatectomized Patients
  • Research • Medicine
    Examining the Characteristics of Episodic Memory using Event-related Potentials in Patients with Alzheimer's Disease
  • Research • Medicine
    Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
  • Research • Medicine
    Manual Muscle Testing: A Method of Measuring Extremity Muscle Strength Applied to Critically Ill Patients
  • Research • Medicine
    Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
  • Research • Medicine
    A Protocol for Comprehensive Assessment of Bulbar Dysfunction in Amyotrophic Lateral Sclerosis (ALS)
  • Research • Medicine
    An Investigation of the Effects of Sports-related Concussion in Youth Using Functional Magnetic Resonance Imaging and the Head Impact Telemetry System
  • Research • Medicine
    Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies
  • Research • Medicine
    Methods to Quantify Pharmacologically Induced Alterations in Motor Function in Human Incomplete SCI
  • Research • Medicine
    Multispectral Real-time Fluorescence Imaging for Intraoperative Detection of the Sentinel Lymph Node in Gynecologic Oncology
  • Research • Medicine
    Technique to Collect Fungiform (Taste) Papillae from Human Tongue
  • Research • Medicine
    Assessing Endothelial Vasodilator Function with the Endo-PAT 2000
  • Research • Medicine
    Making Sense of Listening: The IMAP Test Battery
  • Research • Medicine
    An Experimental Paradigm for the Prediction of Post-Operative Pain (PPOP)
  • Research • Biology
    Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
  • Research • Biology
    Demonstration of Cutaneous Allodynia in Association with Chronic Pelvic Pain
  • Get cutting-edge science videos from JoVE sent straight to your inbox every month.

    Waiting X
    Simple Hit Counter