A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Building Langmuir Probes and Emissive Probes for Plasma Potential Measurements in Low Pressure, Low Temperature Plasmas

6K views

⸱

DOI:

10.3791/61804

⸱

May 25th, 2021

 ,  , 

* These authors contributed equally

In This Article

Summary

The main goal of this work is to make it easier for research groups unfamiliar with Langmuir probes and emissive probes to use them as plasma diagnostics, especially near plasma boundaries. We do this by demonstrating how to build the probes from readily available materials and supplies.

Abstract

Langmuir probes have long been used in experimental plasma physics research as the primary diagnostic for particle fluxes (i.e., electron and ion fluxes) and their local spatial concentrations, for electron temperatures, and for electrostatic plasma potential measurements, since its invention by Langmuir in the early 1920s. Emissive probes are used for measuring plasma potentials. The protocols exhibited in this work serve to demonstrate how these probes may be built for use in a vacuum chamber in which a plasma discharge may be confined and sustained. This involves vacuum techniques for building what is essentially an electrical feedthrough, one that is rotatable and translatable. Certainly, complete Langmuir probe systems may be purchased, but they can also be built by the user at considerable cost savings, and at the same time be more directly adapted to their use in a particular experiment. We describe the use of Langmuir probes and emissive probes in mapping the electrostatic plasma potential from the body of the plasma up to the sheath region of a plasma boundary, which in these experiments is created by a negatively biased electrode immersed within the plasma, in order to compare the two diagnostic techniques and assess their relative advantages and weaknesses. Although Langmuir probes have the advantage of measuring the plasma density and electron temperature most accurately, emissive probes can measure electrostatic plasma potentials more accurately throughout the plasma, up to and including the sheath region.

Introduction

During this first century of plasma physics research, dating from Langmuir’s discoveries in the 1920s of the medium like behavior of a new state of matter, plasma, the Langmuir probe has proved to have been the single most important diagnostic of plasma parameters. This is true in part, because of its extraordinary range of applicability1. In plasma encountered by satellites2,3,4, in semiconductor processing experiments,5,6,7,8

Access restricted. Please log in or start a trial to view this content.

Protocol

1. Building Langmuir probes and Emissive probes to fit into a vacuum chamber

  1. Planar Langmuir probe (see Figure 5 for more details)
    1. Take a ¼” diameter stainless steel tube as the probe shaft and bend one end to the desired 90° angle.
    2. Cut the unbent side to a length so that the probe can axially cover more than half of the chamber length.
    3. Fit the unbent side of the shaft through the brass tube by a SS-4-UT-A-8 adapter in combination with a B-810-6 union tube fitting.
    4. Use a ½” brass tube extending out of the customized flanges through a B-810-1-OR s....

Access restricted. Please log in or start a trial to view this content.

Results

Langmuir probes, known to be sensitive to flows and to the kinetic energy of the particles they collect, have up till now have been considered to yield valid measurement of the plasma potential, except in sheaths. But direct comparisons of plasma potentials measured by Langmuir probes and emissive probes have demonstrated that in the quasineutral presheath region of the plasma immediately in contact with the sheath on the plasma side, Langmuir probes do not provide accurate measurements of the plasma potential

Access restricted. Please log in or start a trial to view this content.

Discussion

Langmuir probes are used for particle flux measurements in an extraordinarily wide range of plasma densities and temperatures, from space plasmas in which the electron density is just a few particles 106 m-3 to the edge region of fusion plasmas where the electron density is more like a few times 1020 m-3. Moreover, electron temperatures between 0.1 and a few hundred eV’s have been diagnosed with Langmuir probes. Langmuir probes are often used to measure plasma density and.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors have nothing to disclose.

Acknowledgements

This work was partially funded by the U.S. Department of Energy (DOE), through grantDE-SC00114226, and the National Science Foundation through grants PHY-1464741, PHY-1464838, PHY-1804654, and PHY-1804240

Tribute to Noah Hershkowitz:
Noah Hershkowitz made groundbreaking contributions to plasma physics while earning the respect and admiration of his colleagues and students, both as a scientist and a human being.  “Physics,” he once explained, “is like a jigsaw puzzle that’s really old. All the pieces are worn down. Their edges are messed up. Some of the pieces have been put together in the ....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
0.001" thick tungsten wireMidwest Tungsten Service0.001"Emissive probe filament
0.005" thick tantalum sheetMidwest Tungsten Service0.005"Heating filament to generate plasma
1/2" Brass supprting tube
1/4" Brass Ferrule SetSwagelokB-400-SETInterface between stainless probe shaft and swagelok tube fitting
1/4" OD 304 or 315 stainless steel tubeSwagelokSS-T4-S-035-20Used to make the probe shaft, order seamless, sold in 20' lengths
Alumina tubesCOORSTEK65655, single bore 0.156" OD 0.094 IDsingle bore, double bore, quadruple bore, use for support structure for both emissive and Langmuir probes between the probe tip and shaft
Baratron gaugeMKSType 127Display the pressure when there's gas flowing in the chamber
Brass Swagelok Tube FittingSwagelokB-400-1-ORTube fittings used on the probe
Brass Swagelok Tube FittingSwagelokB-810-6Tube fittings used on the probe
Brass Swagelok Tube FittingSwagelokB-810-1-ORTube fittings used on the probe
Ceramic liquidSauereisenNo. 31 Ceramic Encapsulant LiquidMix with No.31 cement power to make the ceramic paste
Ceramic powderSauereisenCement Powder No. 31 Off-WhiteThere are Saureisen cements that cure with water, e.g. No.10 Powder
Gold plated nickel wireSYLVANIA ELECTRIC PRODUCTspod-welded to the probe tip to provide supports
Ion gauge controllerGranville-Phillips270 Gauge controllerHeat up the ion gauge and display pressure inside the chamber
Mechanical pumpLeybold D60 D60ACD60 D60ACBring the pressure down to ~10 mTorr then serve as the backing pump for the turbo pump
needle valveWhiteySS-22RS4Metering Micro-Needle Micrometer Valve 1/4" Tube Swagelok fittings
Power supplyKepcoATE 100-10MVoltage Bias supply of heating filament
Power supplySorensenDCR 20-115BHeating supply of heating filament
shutoff valveKurt J. LeskerNupro SS-4BKKnob handle, for 1/4" tubing, swagelok fittings
Stainless Steel Ultra-Torr Vacuum FittingSwagelokSS-4-UT-A-8Tube fittings used on the probe
Teflon coated wireGeyer SystemsP31546Connect the gold-coated wire to BNC pin
Turbo pumpPFEIFFERTPH 240 CBring the pressure down to 1E-6 Torr
Vacuum greaseAPIEZONL Ultra High Vacuum Grade GreaseVacuum grease used to lubricate the oring
Viton OringsGrainger#031Round #031 Medium Hard Viton O-Ring, 1.739" I.D., 1.879" O.D
Viton OringsGrainger#010Round #010 Medium Hard Viton O-Ring, 0.239" I.D., 0.379"O.D

References

  1. Godyak, V. A., Alexandrovich, B. M. Comparative analyses of plasma probe diagnostics techniques. Journal of Applied Physics. 118, 233302(2015).
  2. Gurnett, D. A., et al. The Cassini Radio and Plasma wave investigation. Space Science Reviews. 114, 395-4....

Access restricted. Please log in or start a trial to view this content.