A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Tri-layered Electrospinning to Mimic Native Arterial Architecture using Polycaprolactone, Elastin, and Collagen: A Preliminary Study

12.2K views

⸱

DOI:

10.3791/2084

⸱

January 4th, 2011

 ,  ,  ,  , 

Corresponding Authors: Michael J. McClure <mccluremj2@vcu.edu>

In This Article

Summary

The aim of this study was to mimic the native three layered architecture of the arterial wall. To accomplish this, electrospinning was employed with the use of a 3-1 (input-output) nozzle and blends of polycaprolactone, elastin, and collagen.

Abstract

Throughout native artery, collagen and elastin play an important role, providing a mechanical backbone, preventing vessel rupture, and promoting recovery under pulsatile deformations. The goal of this study was to mimic the structure of native artery by fabricating a multi-layered electrospun conduit composed of poly(caprolactone) (PCL) with the addition of elastin and collagen with blends of 45-45-10, 55-35-10, and 65-25-10 PCL-ELAS-COL to demonstrate mechanical properties indicative of native arterial tissue, while remaining conducive to tissue regeneration. Whole grafts and individual layers were analyzed using uniaxial tensile testing, dynamic compliance, suture retention, and burst strength. Compliance results revealed that changes to the middle/medial layer changed overall graft behavior with whole graft compliance values ranging from 0.8 - 2.8 % / 100 mmHg, while uniaxial results demonstrated an average modulus range of 2.0 - 11.8 MPa. Both modulus and compliance data displayed values within the range of native artery. Mathematical modeling was implemented to show how changes in layer stiffness affect the overall circumferential wall stress, and as a design aid to achieve the best mechanical combination of materials. Overall, the results indicated that a graft can be designed to mimic a tri-layered structure by altering layer properties.

Protocol

  1. Prior to electrospinning, collagen, from 6 month bovine corium, must be extracted using an acetic acid based process. This extracted collagen is then purified through a subsequent series of dissolutions, precipitations, and dialyses. Once collagen is lyophilized, the electrospinning process can begin.
  2. Three materials are massed: polycaprolactone (PCL), elastin (ELAS), and collagen (COL). These materials will be separately dissolved in 1,1,1,3,3,3 hexafluoro-2-propanol (HFP, TCI America) at concentrations of 100 mg/ml, 200 mg/ml, and 70 mg/ml, respectively.
  3. The materials are blended in five different scintillation vials at volumetric ratios of 98-2-0 PCL-EL....

Access restricted. Please log in or start a trial to view this content.

Discussion

The most critical portion of this study is the electrospinning process. When using a 3-1 input-output nozzle, arching and charge loss may occur. If this does occur, the voltage associated with the polymer that is spinning will decrease causing welded, "wet" fibers and creating delamination between each of the three layers. Therefore, consistent electric potentials are essential to obtain an ideal multi-layered tube.

Compliance mismatch is one of the main causes of graft occlusion at the sm.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

Several authors have United States and International patents pending concerning technology presented in this manuscript, and this technology has been licensed to Organogenesis, Inc.

Acknowledgements

We would like to thank the American Heart Association Mid-Atlantic Affiliate (0555407U,GLB) for funding.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
PolycaprolactoneSigma-Aldrich
ElastinElastin Products Company
Collagen
Acetic AcidFisher Scientific
Sodium ChlorideFisher Scientific
TRISFisher Scientific
6 L Avanti J-HC CentrifugeBeckman Coulter Inc.
1,1,1,3,3,3 hexafluoro-2-propanolTCI America
3 ml Becton Dickinson Syringe
CZE1000R Rack Mount Power SupplySpellman
High-Pressure Syringe PumpCole-Parmer
1-ethyl-3-(3-dimethylaminopropyl)-carbodiimidePierce, Thermo Scientific
70 % ethanolSigma-Aldrich
ImageTool 3.0 softwareShareware provided by UTHSCSA
Scanning Electron MicroscopeCarl Zeiss, Inc.
MTS Bionix 200 testing systemMTS Systems Corp.
TestWorks version 4
Intelligent Tissue Engineering via Mechanical Stimulation (ITEMS) BioreactorTissue Growth Technologies

References

  1. McClure, M. J., Sell, S. A., Barnes, C. P., Bowen, W. C., Bowlin, G. L. Cross-linking Electrospun Polydioxanone-Soluble Elastin Blends: Material Characterization. Journal of Engineered Fibers and Fabrics. 3, 1-10 (2008).
  2. Cardiovascular implants - Vascular graft protheses

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Arterial Graft FabricationPolycaprolactone Elastin CollagenUniaxial Tensile TestingDynamic Compliance AnalysisSuture Retention TestingBurst Strength MeasurementMathematical ModelingPCL Elastin Collagen BlendsElectrospinning Parameter Optimization