To assess the timing of nuclear degeneration in the receptive synergid with respect to pollen tube rupture in Arabidopsis, as well as to observe whether the left or right synergid is predestined to become the receptive synergid, the SIV cum septum method described here was employed using a female gametophyte nuclear marker stacked with a synergid cytosolic marker (pFG:roGFP2-ORP1-NLS, pMYB98:roGFP2-ORP1) as the septum donor and a male gametophyte marker (pLAT52:R-GECO) as the pollen donor. The septa and pollinated stigmas were dissected 24 h after emasculation, according to sections 4-5 of the protocol, and placed onto glass bottom dishes with a medium prepared the day before. Each dish was placed in a humidity chamber on the microscope, and a multistage experiment was performed using a 10x objective lens (numerical aperture: 0.4) with five overview areas (Figure 3). Images of each area were taken every 60 s for 9 h with four fluorescent channels: Channel (1) 560/640 for R-GECO (25 ms), Channel (2) 488/520 for roGFP2-ORP1 (60 ms), Channel (3) 387/520 for roGFP2-ORP1 (60 ms), and Channel (4) 387/640 for background subtraction (60 ms) (Table 1). An autofocus function using a 100 µm range with 7 µm coarse stepping and 1 µm fine stepping was employed for each minute before image acquisition. The five image files were opened in FIJI, the channels were separated, and then the images were manually tiled together (Video 2 and Supplementary File 1).
In Video 2 (also see Supplementary File 1), 41 examples of explosive pollen tube rupture in the synergids can be seen within the ovules, with green squares marking the regions of interest. Using the calcium biosensor line pLAT52:RGECO as the pollen donor, instances of explosive pollen tube rupture were seen at the tips of the pollen tubes where they lyse. Notably, there was a rapid increase in the brightness of the biosensor as a result of its sudden exposure to high levels of calcium. Explosive pollen tube rupture can also be analyzed with GFP-based or RFP-based sperm cell or cytosolic markers, which also show rapid release of the sperm or cytoplasmic content. Upon pollen tube rupture, the nucleus of the receptive synergid was observed to degrade simultaneously (within the 1 min time resolution in the experiment), and migration of the egg cell nucleus toward the micropyle was also seen upon pollen tube rupture as a result of karyogamy (Video 3 and Supplementary File 1). Both the left and right synergids were able to serve as the receptive synergid, and instances of two pollen tube bursts were observed, firstly in the receptive synergid and secondly in the persistent synergid. Video 2 (also see Supplementary File 1) shows 10 examples of defective pollen tube reception, which can be seen in the ovules, with the regions of interest marked by red squares. Thus, the overall efficiency of pollen tube reception was ~80% with respect to the ovules that attracted pollen tubes. In these unsuccessful cases, the pollen tubes either arrest their growth in the micropyle, arrest their growth after the fast growth into the synergids, or fail to arrest their growth and continue growing and coiling within the embryo sac. The ovules without any indicated regions of interest failed to attract pollen tubes or were not in an accessible orientation. Enlarged examples of negative and positive outcomes can be seen in Video 3 (also see Supplementary File 1), showing two instances of defective pollen tube reception (Video 3A,C and Supplementary File 1), and two instances of successful pollen tube reception (Video 3B,D and Supplementary File 1).

Figure 4: Comparison of SIV method efficiencies. Eight technical replicates of the SIV excised ovules method (71 total ovules) showed only ~28% ovules with explosive pollen tube bursts, resulting in an efficiency ranging from ~10%-50%. Five technical replicates of the SIV cum septum method (8 septa and 102 ovules) showed ~79% ovules with explosive pollen tube burst, resulting in an efficiency ranging from ~70%-100%. Only ovules that attracted pollen tubes to the micropyle and ovules that had enough recorded time to receive the attracted pollen tube were counted. The "X" denotes the mean and the center line the median value (50th percentile), respectively. The lines outside the upper and lower quartiles show the minimum and maximum percentages of successful pollen tube reception. The percentage of ovules with pollen tube burst was significantly different (p < 0.001) between the two methods based on an unpaired t-test. Abbreviation: SIV = semi-in vitro. Please click here to view a larger version of this figure.
| Equipment/Setting | Supplemental Video 2 & 3 |
| Microscope | Olympus IX-81F-ZDC2 inverted microscope |
| Temperature control | Life Imaging Services GmbH Cube & Box (22C) |
| Humidity control | Life Imaging Services GmbH Brick (92% relative humidity) |
| Software | Olympus cellSens Dimension 2.3 |
| Real time controller | Olympus U-RTC |
| Laser | MT20- 150 W xenon arc burner |
| Objective lens | 10x air immersion U Plan SApo objective lens (0.4 NA), working distance 3.1 mm |
| Mirror Cube | GFP/RFP |
| Filter Wheel | Olympus U-FFWO |
| Channel 1 (25 ms) : reflected (560/25) observation (624/40) |
| Channel 2 (60 ms): reflected (485/20) observation (525/30) |
| Channel 3 (60 ms): reflected (387/11) observation (525/30) |
| Channel 4 (60 ms): reflected (387/11) observation (624/30) |
| Detector | Hamamatsu ORCA-Fusion Digital CMOS camera |
| Autofocus | 100 µm range, 7 µm coarse step, 1 µm fine step |
| Time interval | 1 min |
Table 1: The microscope systems and settings used in this manuscript.
Video 1: Timelapses of the SIV excised ovules method. Merged timelapse from eight technical replicates of SIV using excised ovules showing the growth of pollen tubes (harboring pLAT52:R-GECO) and pollen tube reception within the ovules. The 20 green boxes show instances of explosive pollen tube burst in the synergids, and the 51 red boxes show instances of failed pollen tube burst and overgrowth. The time lapses are between 260 min and 400 min, and the scale bar is 100 µm. Please click here to download this Video.
Video 2: SIV cum septum timelapse. (A) Merged timelapse from all five overview areas (see Figure 3) of pollen tube growth and reception within the ovules with just the RFP channel (Channel 1). The pollen is harboring pLAT52:R-GECO and the ovules pFG:roGFP2-ORP1-NLS; pMYB98:roGFP2-ORP1. The 41 green boxes show instances of explosive pollen tube burst, and the 10 red boxes show instances of failed pollen tube burst and pollen tube overgrowth. (B) The same timelapse with both the RFP and GFP channels (Channel 1 and Channel 2), showing the nuclear dynamics in the gametes and synergid cells during pollen tube reception. The numbers on the top right indicate the time (h:min). Scale bar = 500 µm. Please click here to download this Video.
Video 3: Examples of positive and negative outcomes from SIV cum septum. (A,C) Example ovules taken from Video 2 showing two instances of failed fertilization. In A, the pollen tubes fail to arrest growth and continue coiling in the embryo sac. In C, a second category of pollen tube overgrowth is seen, where the first pollen tube undergoes fast growth as it grows into the synergid but arrests growth without rupturing. (B,D) Example ovules taken from Video 2 showing two instances of successful pollen tube reception. The wild-type-like pollen tube burst shows the explosive rupture of the pollen tube in the synergids, and the migration of the egg cell nucleus toward the micropyle indicates karyogamy. The numbers on the top right indicate the time (h:min). The arrowheads indicate the receptive synergid nuclei (rSN), and the arrows indicate the migration of the egg cell nucleus (EN) after pollen tube burst (lysis). Scale bar = 30 µm. Please click here to download this Video.
Supplementary File 1: Still images of Video 1, Video 2, and Video 3. Please click here to download this File.