Identifying Regulatory T Cell Subsets from Murine Pancreatic Draining Lymph Nodes

Published: July 31, 2023

Abstract

Source: Luo, Z., et al. Determination of Regulatory T Cell Subsets in Murine Thymus, Pancreatic Draining Lymph Node and Spleen Using Flow Cytometry. J. Vis. Exp.  (2019)

In this video, we describe a protocol for isolating single cells from murine pancreatic draining lymph nodes (PDLNs) and the characterization of regulatory T cells (Tregs) from the single-cell population using flow cytometry. Tregs are identified based on the positive expression of the cell-surface markers CD4, CD25, and Nrp1, along with the nuclear transcription factors Foxp3 and Helios.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board. 1. Single Cell Isolation from PDLN Place a sterile 250 µm metal mesh over a 15 mL conical tube in a rack. Rinse the mesh with 1 mL of RPMI. Transfer the lymph nodes to the metal mesh and grind them through the mesh using a pair of tweezers. Apply 1 mL of RPMI on the metal mesh to flush the cells into the tub…

Offenlegungen

The authors have nothing to disclose.

Materials

RPMI-1640 Sigma-Aldrich R0883-500ML
eBioscience Foxp3 / Transcription Factor-Staining Buffer Set ThermoFisher 00-5523-00 Contains Fixation/Permeabilization Concentrate, Fixation/ Permeabilization Diluent and Permeabilization Buffer (10x)
eBioscience Flow Cytometry Staining Buffer ThermoFisher 00-4222-26
CD4 Monoclonal Antibody (RM4-5), FITC, eBioscience ThermoFisher 11-0042-85
CD25 Monoclonal Antibody (PC61.5), PE, eBioscience ThermoFisher 12-0251-83
BD Pharmingen APC-H7 Rat antiMouse CD8a BD Biosciences 560182
Mouse Neuropilin-1 APC-conjugated Antibody R&D Systems FAB5994A
FOXP3 Monoclonal Antibody (FJK-16s), PE-Cyanine7, eBioscience ThermoFisher 25-5773-82
Pacific Blue anti-mouse/human Helios Antibody BioLegend 137220
Falcon 5 mL Round-Bottom Polystyrene Test Tube, with Cell Strainer Snap Cap CORNING 352235 A 35 µm nylon mesh is incorporated into the dual-position snap cap
Tube 15 mL, 120 mm x17 mm, PP Sarstedt 62.554.002
Flow cytometry BD
Flow cytometry analysis software Inivai Technologies Flowlogic

Tags

Play Video

Diesen Artikel zitieren
Identifying Regulatory T Cell Subsets from Murine Pancreatic Draining Lymph Nodes. J. Vis. Exp. (Pending Publication), e21530, doi: (2023).

View Video