A mass spectrometry imaging (MSI) source operated at atmospheric pressure was developed by coupling mid-infrared laser desorption and electrospray post-ionization. Exogenous ice matrix was used as the energy-absorbing matrix to facilitate resonant desorption of tissue-related material. This manuscript provides a step-by-step protocol for performing IR-MALDESI MSI of whole-body neonatal mouse.

Abstract

Ambient Ionisierungsquellen für die Massenspektrometrie (MS) sind das Thema von großem Interesse in den letzten zehn Jahren. Matrix-unterstützte Laser – Desorption Elektrospray – Ionisation (MALDESI) ist ein Beispiel für solche Verfahren, in denen Merkmale der Matrix-unterstützte Laser – Desorption / Ionisation (MALDI) (zB gepulste Art der Desorption) und Elektrospray – Ionisation (ESI) (zB Soft Ionisierung ) kombiniert werden. Einer der wichtigsten Vorteile der MALDESI ist die inhärente Variabilität. In MALDESI Experimenten eine Ultraviolett (UV) oder Infrarot (IR) -Laser kann auf resonant eine endogene oder exogene Matrix erregt verwendet werden. Die Wahl der Matrix ist nicht Analyten abhängig und hängt allein von der Laserwellenlänge zur Anregung verwendet. In IR-MALDESI Experimenten wird eine dünne Eisschicht auf der Probenoberfläche als eine energieabsorbierende Matrix abgeschieden. Die IR-MALDESI Quellengeometrie wurde für die Analyse von flüssigen Proben sowie biol mittels statistischer Versuchsplanung (DOE) optimiertlogischen Gewebeproben. Weiterhin wurde eine robuste IR-MALDESI Abbildungsquelle entwickelt, bei denen ein abstimmbarer mid-IR-Laser wird mit einem computergesteuerten XY-Translationsstufe und ein hohes Auflösungsvermögen Massenspektrometers synchronisiert. Eine angepasste grafische Benutzeroberfläche (GUI) Benutzerauswahl der Repetitionsrate des Lasers, die Anzahl der Aufnahmen pro Voxel, Schrittgröße der Probe Bühne, und die Verzögerung zwischen der Desorption und Scan-Ereignisse für die Quelle erlaubt. IR-MALDESI wurde in einer Vielzahl von Anwendungen, wie forensische Analyse von Fasern und Farbstoffe und MSI von biologischen Gewebeschnitten verwendet. Verteilung verschiedener Analyten aus endogenen Metaboliten exogene Xenobiotika in Gewebeschnitten im Bereich kann mit dieser Technik gemessen und quantifiziert werden. Das Protokoll in diesem Manuskript präsentiert beschreibt wichtige Schritte, die für IR-MALDESI MSI von Ganzkörpergewebeschnitten.

Introduction

Massenspektrometrie imaging (MSI) in Mikro Modus beinhaltet Desorption der Probe von einer Oberfläche durch einen Strahl (Laser oder Ionen) an diskreten Stellen über die Oberfläche einer Probe. An jedem Rasterpunkt wird ein Massenspektrum erzeugt, und die erfassten Spektren, zusammen mit den räumlichen Standort, von dem sie gesammelt wurden, können gleichzeitig verwendet werden, um zahlreiche Analyten in der Probe abzubilden. Diese markierungsfreie Art und Weise der Bildgebung auf die Sensitivität und Spezifität der Massenspektrometrie gekoppelt haben MSI einer der am schnellsten entwickelnden Felder in der Massenspektrometrie 1,2 verhalf.

Matrix-unterstützte Laser-Desorption / Ionisation (MALDI) ist die häufigste Ionisationsverfahren verwendet für MSI analysiert. Jedoch stellen die Notwendigkeit einer organischen Matrix und die Vakuumanforderungen von MALDI erhebliche Einschränkungen auf Reproduzierbarkeit, Probendurchsatz und die Arten von Proben, die unter Verwendung des Verfahrens analysiert werden kann. Eine Reihe von Atmosphärendruck (AP) iosation Verfahren wurden in den letzten Jahren entwickelt , um diese Beschränkungen 3 zu umgehen. Diese Umgebungs Ionisierungsmethoden ermöglichen die Analyse von biologischen Proben in einer Umgebung, die viel näher an ihrem natürlichen Zustand ist und Probenvorbereitungsschritte vor der Analyse zu vereinfachen. Matrix-unterstützte Laser – Desorption Elektrospray – Ionisation (MALDESI) ist ein Beispiel eines solchen Ionisationsverfahren 4,5.

In IR-MALDESI Experimenten wird eine dünne Eisschicht auf der Gewebeoberfläche als energieabsorbierende Matrix abgeschieden. A mid-IR-Laserpuls wird durch das Eis-Matrix absorbiert wird, und erleichtert die Desorption von neutralen Materialien von der Oberfläche durch resonant Erregen der OH-Streckschwingung von Wasser. Das desorbierte Neutralen Trennwand in die geladenen Tröpfchen eines orthogonalen Elektrospray- und sind post-ionisiert in einer ESI artig 4-6. Die Zugabe von exogenen Eismatrix wird bevorzugt über allein auf dem endogenen Wasser im Gewebe zu verlassen, da es ac hilftzählen für Variationen des Wassergehalts in verschiedenen Gewebekammern und gezeigt wurde von ~ 15-fach 7,8 in Gewebeabbildungsexperimenten Desorption 6 und verbessern Ionenabundanz zu verbessern.

In dieser Arbeit verwenden wir IR-MALDESI MSI die Verteilung von Metaboliten in den verschiedenen Organen in einem neugeborenen Maus ganzen Körper zu entlocken. Eine Übersicht der einstellbaren Parameter des IR-MALDESI Quelle gegeben ist, und die notwendigen Schritte für die erfolgreiche Bildgebung von Gewebeschnitten demonstriert.

Protocol

Hinweis: Das folgende Protokoll, alle notwendigen Schritte zur Durchführung einer IR-MALDESI MSI Experimente beschreibt. In ausführlichen Details über die optimierte Geometrie der IR-MALDESI Quelle und deren Synchronisation mit dem Laser, Stadium und Massenspektrometer kann an anderer Stelle 5,6 gefunden werden. Tiergewebeproben in diesem Protokoll verwendet wurden nach Institutional Animal Care erhalten und Use Committee (IACUC) und North Carolina State University Vorschriften. …

Representative Results

Die Bilder in Abbildung 4 zeigen die räumliche Verteilung der Metaboliten in verschiedenen Organen in der Ganzkörpergewebeabschnitt. Einzigartige m / z – Werte auf bestimmte Regionen des Körpers wurden unter Verwendung gefunden MSiReader Peakfinder, die von der Stapelverarbeitung zur Bilderzeugung folgt. Die Bildüberlagerungswerkzeug (Bild 3-4) wurde verwendet , um das optische Bild vor Eismatrix Abscheidung mit den resultierenden Ionenkarte…

Discussion

Das Protokoll über beschreibt die wichtigsten Schritte zur Durchführung eines IR-MALDESI MSI Experiment. Die Matrix Bewerbungsverfahren (Abschnitt 3) dauert ca. 20 min, die für die MALDI-MSI-Experimente durch Sublimation oder Sprühbeschichten mit einem Roboter-Sprayer auf eine typische Matrix Bewerbungsverfahren ähnlich ist. Darüber hinaus IR-MALDESI beruht nicht auf Partitionierung von Analyten in die Matrixkristalle 6 und die Eis – Matrix kann universell für alle Analyten unabhängig von ihrer Masse,…

Offenlegungen

The authors have nothing to disclose.

Acknowledgements

The authors thank Professor H. Troy Ghashghaei from NCSU Department of Molecular Biomedical Sciences for providing the whole mouse tissue. The authors also gratefully acknowledge the financial assistance received from National Institutes of Health (R01GM087964), the W.M. Keck foundation, and North Carolina State University.

Materials

IR-MALDESI Source Custom-made N/A Please refer to references 4 and 12 for an in-depth discussion of IR-MALDESI source development.
Q Exactive Plus  Thermo Scientific Q Exactive Plus Hybrid Quadrupole-Orbitrap Mass Spectrometer
Water, HPLC Grade Burdick & Jackson  AH365-4
Methanol, HPLC Grade Burdick & Jackson  AH230-4
Formic Acid Sigma Aldrich  56302
Tunable mid-IR Laser Opotek Inc. IR Opolette Tunable 2700-3100 nm IR OPO laser
Nitrogen Gas Arc3 Gases AG S-NI300-5.0 Grade 5.0 high purity nitrogen gas cylinder (300)
Cryostat Leica Biosystems CM 1950 Cryomicrotome
High Profile Microtome Blades Leica Biosystems 3802123 Leica DB80HS
Mounting Medium (OCT) Leica Biosystems 3801480 Surgipath FSC 22 mounting medium
Cryostat Specimen Disc Leica Biosystems 14047740045 40 mm diameter
Glass Microscope Slides VWR 48312-003 Frosted, selected, pre-cleaned

Referenzen

  1. Mcdonnell, L. A., Heeren, R. M. A. Imaging Mass Spectrometry. Mass Spectrom. Rev. 26, 606-643 (2007).
  2. Chughtai, K., Heeren, R. M. A. Mass spectrometric imaging for biomedical tissue analysis. Chem. Rev. 110 (5), 3237-3277 (2010).
  3. Robichaud, G., Barry, J. A., Muddiman, D. C. Atmospheric Pressure Mass Spectrometry Imaging. Encycl. Anal. Chem. , (2014).
  4. Sampson, J. S., Hawkridge, A. M., Muddiman, D. C. Generation and detection of multiply-charged peptides and proteins by matrix-assisted laser desorption electrospray ionization (MALDESI) Fourier transform ion cyclotron resonance mass spectrometry. J. Am. Soc. Mass Spectrom. 17 (12), 1712-1716 (2006).
  5. Robichaud, G., Barry, J. A., Garrard, K. P., Muddiman, D. C. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) imaging source coupled to a FT-ICR mass spectrometer. J. Am. Soc. Mass Spectrom. 24 (1), 92-100 (2013).
  6. Robichaud, G., Barry, J. A., Muddiman, D. C. IR-MALDESI Mass Spectrometry Imaging of Biological Tissue Sections Using Ice as a Matrix. J. Am. Soc. Mass Spectrom. 25 (3), 319-328 (2014).
  7. Barry, J. A., et al. Mapping Antiretroviral Drugs in Tissue by IR-MALDESI MSI Coupled to the Q Exactive and Comparison with LC-MS/MS SRM Assay. J. Am. Soc. Mass Spectrom. 25 (12), 2038-2047 (2014).
  8. Rosen, E. P., Bokhart, M. T., Ghashghaei, H. T., Muddiman, D. C. Influence of Desorption Conditions on Analyte Sensitivity and Internal Energy in Discrete Tissue or Whole Body Imaging by IR-MALDESI. J. Am. Soc. Mass Spectrom. 26, 899-910 (2015).
  9. Nelson, K. A., Daniels, G. J., Fournie, J. W., Hemmer, M. J. Optimization of whole-body zebrafish sectioning methods for mass spectrometry imaging. J. Biomol. Tech. 24 (3), 119-127 (2013).
  10. Park, J. J., Cunningham, M. G. Thin sectioning of slice preparations for immunohistochemistry. J. Vis. Exp. (3), e194 (2007).
  11. Bokhart, M. T., Rosen, E., Thompson, C., Sykes, C., Kashuba, A. D. M., Muddiman, D. C. Quantitative mass spectrometry imaging of emtricitabine in cervical tissue model using infrared matrix-assisted laser desorption electrospray ionization. Anal. Bioanal. Chem. 407 (8), 2073-2084 (2015).
  12. Nazari, M., Muddiman, D. C. Polarity Switching Mass Spectrometry Imaging of Healthy and Cancerous Hen Ovarian Tissue Sections by Infrared Matrix-Assisted Laser Desorption Electrospray Ionization (IR-MALDESI). Analyst. 141, 595-605 (2016).
  13. Hsu, C. C., et al. Design and Application of a Low-Temperature Peltier-Cooling Microscope. J. Pharm. Sci. 85 (1), 70-74 (1996).
  14. Jurchen, J. C., Rubakhin, S. S., Sweedler, J. V. MALDI-MS imaging of features smaller than the size of the laser beam. J. Am. Soc.Mass Spectrom. 16 (10), 1654-1659 (2005).
  15. Nazari, M., Muddiman, D. C. Cellular-level mass spectrometry imaging using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) by oversampling. Anal. Bioanal. Chem. 407 (8), 2265-2271 (2015).
  16. Rosen, E. P., Bokhart, M. T., Nazari, M., Muddiman, D. C. Influence of C-Trap Ion Accumulation Time on the Detectability of Analytes in IR-MALDESI MSI. Anal. Chem. 87, 10483-10490 (2015).
  17. Kessner, D., Chambers, M., Burke, R., Agus, D., Mallick, P. ProteoWizard: open source software for rapid proteomics tools development. Bioinformatics. 24 (21), 2534-2536 (2008).
  18. Schramm, T., et al. ImzML – A common data format for the flexible exchange and processing of mass spectrometry imaging data. J. Proteomics. 75 (16), 5106-5110 (2012).
  19. Race, A. M., Styles, I. B., Bunch, J. Inclusive sharing of mass spectrometry imaging data requires a converter for all. J. Proteomics. 75 (16), 5111-5112 (2012).
  20. Robichaud, G., Garrard, K. P., Barry, J. A., Muddiman, D. C. MSiReader: an open-source interface to view and analyze high resolving power MS imaging files on Matlab platform. J. Am. Soc. Mass Spectrom. 24 (5), 718-721 (2013).
  21. Smith, C. A., O’Maille, G., et al. METLIN: a metabolite mass spectral database. Ther. Drug. Monit. 27 (6), 747-751 (2005).
  22. Sud, M., et al. LMSD: LIPID MAPS structure database. Nucleic Acids Res. 35, D527-D532 (2007).
  23. Schwartz, S. A., Reyzer, M. L., Caprioli, R. M. Direct tissue analysis using matrix-assisted laser desorption/ionization mass spectrometry: practical aspects of sample preparation. J. Mass Spectrom. 38 (7), 699-708 (2003).
  24. Takai, N., Tanaka, Y., Inazawa, K., Saji, H. Quantitative analysis of pharmaceutical drug distribution in multiple organs by imaging mass spectrometry. Rapid Commun. Mass Spectrom. 26 (13), 1549-1556 (2012).
  25. Liu, J., Gingras, J., Ganley, K. P., Vismeh, R., Teffera, Y., Zhao, Z. Whole-body tissue distribution study of drugs in neonate mice using desorption electrospray ionization mass spectrometry imaging. Rapid Commun. Mass Spectrom. 28 (2), 185-190 (2014).
check_url/de/53942?article_type=t

Play Video

Diesen Artikel zitieren
Nazari, M., Bokhart, M. T., Muddiman, D. C. Whole-body Mass Spectrometry Imaging by Infrared Matrix-assisted Laser Desorption Electrospray Ionization (IR-MALDESI). J. Vis. Exp. (109), e53942, doi:10.3791/53942 (2016).

View Video