The goal of this protocol is to apply dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) for orthotopic pancreatic tumor xenografts in mice. DCE-MRI is a non-invasive method to analyze microvasculature in a target tissue, and useful to assess vascular response in a tumor following a novel therapy.

Abstract

Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) has been limitedly used for orthotopic pancreatic tumor xenografts due to severe respiratory motion artifact in the abdominal area. Orthotopic tumor models offer advantages over subcutaneous ones, because those can reflect the primary tumor microenvironment affecting blood supply, neovascularization, and tumor cell invasion. We have recently established a protocol of DCE-MRI of orthotopic pancreatic tumor xenografts in mouse models by securing tumors with an orthogonally bent plastic board to prevent motion transfer from the chest region during imaging. The pressure by this board was localized on the abdominal area, and has not resulted in respiratory difficulty of the animals. This article demonstrates the detailed procedure of orthotopic pancreatic tumor modeling using small animals and DCE-MRI of the tumor xenografts. Quantification method of pharmacokinetic parameters in DCE-MRI is also introduced. The procedure described in this article will assist investigators to apply DCE-MRI for orthotopic gastrointestinal cancer mouse models.

Introduction

Das übergeordnete Ziel dieser Methode ist es, dynamische kontrastverstärkten Magnetresonanztomographie (DCE-MRI) für orthotopen Pankreastumor-Xenografts bei Mäusen anzuwenden. DCE-MRI ist eine nicht-invasive Methode zur Mikrovaskulatur in einem Zielgewebe durch Überwachung der Änderung des MR Kontrast über einen bestimmten Zeitraum nach der Injektion beurteilt. DCE-MRI wurde verwendet, um bösartige Tumore zu diagnostizieren und Tumor-Antwort auf verschiedene Therapien 1-4 zu beurteilen. Quantitative DCE-MRI hat hohe Reproduzierbarkeit 5 vorgestellt. Pharmakokinetischen Parameter eines MR-Kontrastmittels in ein Zielgewebe quantifizieren, müssen alle zu unterschiedlichen Zeitpunkten und T1 Karte vor Kontrastmittelinjektion erhalten erworbenen DCE-MR-Bilder koregistriert 6 werden. Aufgrund der Atemwege und peristaltische Bewegungen im Bauchbereich, quantitative DCE-MRI hat begrenzte Anwendung für Magen-Darm-Tumoren.

Wurden orthotopen Pankreastumormodelle verwendet werden, um zu bewertenPankreas-Tumor-Antwort folgenden biologischen Therapien und Chemotherapien 7,8. Orthotope Tumormodelle werden als überlegen gegenüber herkömmlichen subkutanen Modellen, da die Mikroumgebung in der ursprünglichen Tumorstelle reflektiert wird und dadurch die menschliche Tumor-Antwort auf die Therapie genauer vorhergesagt werden. Jedoch ist die Maus Bauchspeicheldrüse im linken oberen Quadranten des Abdomens angeordnet ist, so quantitative DCE-MRI des orthotopischen Pankreastumor-Xenotransplantaten in Mäusen nicht leicht implementiert.

Wir haben ein Protokoll der DCE-MRI von Bauch Tumoren in Mäusen durch die Festsetzung der Tumoren mit einer orthogonal gebogenen Kunststoffplatte, um Bewegungsübertragung von der Brustbereich 9 zu verhindern etabliert. Die von diesem Platte aufgebracht Druck auf den Bauchbereich lokalisiert und nicht in Atemnot führte. Eine automatisierte Bild Koregistrierung Technik für DCE-MRI der Bauchorgane in einem Freiatemmodus validiert, aber es führt effectively nur dann, wenn die Zielregionen bewegen sich langsam und regelmäßig 10. Die Atemfrequenz von Tieren ist während der Bildvariablen werden so physische Zurückhaltung im Bauchbereich erforderlich sein, zuverlässig pharmakokinetischen Parameter in orthotopen Pankreastumormausmodelle abzurufen. Wir haben erfolgreich quantifiziert die pharmakokinetischen Parameter von einem MR-Kontrastmittel in orthotopen Pankreastumor-Xenotransplantaten mit dem orthogonal gebogenen Kunststoffplatte in DCE-MRI 11-13. Hier präsentieren wir die Einzelheiten des Verfahrens der orthotopen Pankreastumor-Modellierung, DCE-MRI der Tumorfremdtransplantaten in Mäusen, und die Quantifizierung der pharmakokinetischen Parameter.

Protocol

Alle Verfahren wurden von der Institutional Animal Care und Verwenden Committee an der Universität von Alabama in Birmingham angenommen. 1. orthotopen Pankreastumormausling Kultur Standard menschlichen Pankreas-Krebszelllinien in Dulbeccos modifiziertem Eagle-Medium (DMEM) mit 10% fötalem Rinderserum. Behalten Sie alle Kulturen bei 37 ° C in feuchter Atmosphäre mit 5% CO 2. Verwenden Sie 8-10 Wochen alte weibliche schwere kombinierte immundefizienten Mäus…

Representative Results

Menschliche Pankreastumorzellen erfolgreich wachsen in Mauspankreas Schaffung eines soliden Tumors. 1 zeigt Fotografien von (a) einem normalen Pankreas wo Tumorzelllösung eingespritzt wird, und (B) ein Vertreter der Maus trägt eine orthotope Pankreas Tumorxenotransplantates (MIA PaCa-2 ). Tumor im linken oberen Quadranten des Abdomens, neben der Milz. Es dauert normalerweise 2-4 Wochen, die Tumoren zu 5 aufwachsen – 7 mm Durchmesser nach Zellimplantation. Bewegung orthotop…

Discussion

Wir haben die detaillierten Methoden der orthotopen Pankreastumor Modellierung mit immundefizienten Mäusen, DCE-MRI von Bauch Tumoren in Mäusen, und die Quantifizierung ihrer kinetischen Parameter eingeführt. Im orthotopen Pankreastumor-Modellierung, müssen Sie beim Einsetzen einer Nadel in den Schwanz der Bauchspeicheldrüse entnommen werden. Wenn dies gelingt, werden Zellen auf den Kopf der Bauchspeicheldrüse Schaffung einer kleinen Blase übertragen werden. Bei der Anwendung eines orthogonal gebogenen Kunststoff…

Divulgations

The authors have nothing to disclose.

Acknowledgements

Authors thank Jeffrey Sellers to assist orthotopic pancreatic cancer mouse modeling. This work was supported by Research Initiative Pilot Awards from the Department of Radiology at UAB and NIH grants 2P30CA013148 and P50CA101955.

Materials

Name of Material/ Equipment Company Catalog Number Comments/Description
DMEM Invitrogen 11965-118
Fetal bovine serum Harlan Laboratories BT-9501
Betadine Purdue products 67618-153-01
5-0 Prolene sutures Ethicon 8720H
9.4T MR scanner Bruker Biospin Corporation BioSpec 94/20 USR
Gadoteridol Bracco Diagnostics Inc NDC 0270-1111-03
Micro-polyethelene tube Strategic Applications, Inc #PE-10-25
30G blunt tip needle Strategic Applications, Inc 89134-194
Monitoring and gating system SA instruments, Inc Model 1030 This is an MR compatiable system to measure resiratory rating and body temperature of small animals at the same time.
Syringe pump New Era Pump Systems, Inc. NE-1600

References

  1. Ergul, N., et al. Assessment of multifocality and axillary nodal involvement in early-stage breast cancer patients using 18F-FDG PET/CT compared to contrast-enhanced and diffusion-weighted magnetic resonance imaging and sentinel node biopsy. Acta Radiol. , (2014).
  2. Park, J. J., et al. Assessment of early response to concurrent chemoradiotherapy in cervical cancer: value of diffusion-weighted and dynamic contrast-enhanced MR imaging. Magn Reson Imaging. , (2014).
  3. Nguyen, H. T., et al. Prediction of chemotherapeutic response in bladder cancer using K-means clustering of dynamic contrast-enhanced (DCE)-MRI pharmacokinetic parameters. J Magn Reson Imaging. 10, (2014).
  4. Teo, Q. Q., Thng, C. H., Koh, T. S., Ng, Q. S. Dynamic Contrast-enhanced Magnetic Resonance Imaging: Applications in Oncology. Clin Oncol (R Coll Radiol). , (2014).
  5. Zhang, X., Pagel, M. D., Baker, A. F., Gillies, R. J. Reproducibility of magnetic resonance perfusion imaging. PLoS One. 9 (2), e89797 (2014).
  6. Kim, H., et al. Pancreatic adenocarcinoma: a pilot study of quantitative perfusion and diffusion-weighted breath-hold magnetic resonance imaging. Abdominal imaging. , (2014).
  7. Derosier, L. C., et al. Combination Treatment with TRA-8 Anti Death Receptor 5 Antibody and CPT-11 Induces Tumor Regression in an Orthotopic Model of Pancreatic Cancer. Clin Cancer Res. 13 (18), 5535s-5543s (2007).
  8. Derosier, L. C., et al. TRA-8 anti-DR5 monoclonal antibody and gemcitabine induce apoptosis and inhibit radiologically validated orthotopic pancreatic tumor growth. Mol Cancer Ther. 6 (12), 3198-3207 (2007).
  9. Kim, H., et al. Early therapy evaluation of combined anti-death receptor 5 antibody and gemcitabine in orthotopic pancreatic tumor xenografts by diffusion-weighted magnetic resonance imaging. Cancer Res. 68 (20), 8369-8376 (2008).
  10. Klein, S., Staring, M., Murphy, K., Viergever, M. A., Pluim, J. P. elastix: a toolbox for intensity-based medical image registration. IEEE Trans Med Imaging. 29 (1), 196-205 (2010).
  11. Kim, H., et al. Early therapy evaluation of combined cetuximab and irinotecan in orthotopic pancreatic tumor xenografts by dynamic contrast-enhanced magnetic resonance imaging. Mol Imaging. 10 (3), 153-167 (2011).
  12. Kim, H., et al. Antagonistic effects of anti-EMMPRIN antibody when combined with chemotherapy against hypovascular pancreatic cancers. M Mol Imaging Biol. 16 (1), 85-94 (2014).
  13. Kim, H., et al. Dual combination therapy targeting DR5 and EMMPRIN in pancreatic adenocarcinoma. Mol Cancer Ther. 11 (2), 405-415 (2012).
  14. Moyher, S. E., Vigneron, D. B., Nelson, S. J. Surface coil MR imaging of the human brain with an analytic reception profile correction. J Magn Reson Imaging. 5 (2), 139-144 (1995).
  15. Voigt, T., Nehrke, K., Doessel, O., Katscher, U. T1 corrected B1 mapping using multi-TR gradient echo sequences. Magn Reson Med. 64 (3), 725-733 (2010).
  16. Liu, H., Liu, Y., Zhao, Z., Zhang, L., Qiu, T. A new background distribution-based active contour model for three-dimensional lesion segmentation in breast DCE-MRI. Medical physics. 41 (8), 082303 (2014).
  17. Sarkar, S., Das, S. Multilevel image thresholding based on 2D histogram and maximum Tsallis entropy–a differential evolution approach. IEEE Trans Image Process. 22 (12), 4788-4797 (2013).
  18. Yankeelov, T. E., et al. Quantitative pharmacokinetic analysis of DCE-MRI data without an arterial input function: a reference region model. Magn Reson Imaging. 23 (4), 519-529 (2005).
  19. Cardenas-Rodriguez, J., Howison, C. M., Pagel, M. D. A linear algorithm of the reference region model for DCE-MRI is robust and relaxes requirements for temporal resolution. Magn Reson Imaging. 31 (4), 497-507 (2013).
  20. Tofts, P. S., et al. Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols. J Magn Reson Imaging. 10 (3), 223-232 (1999).
  21. Yankeelov, T. E., et al. Comparison of a reference region model with direct measurement of an AIF in the analysis of DCE-MRI data. Magn Reson Med. 57 (2), 353-361 (2007).
  22. Cao, R. Y., Amand, T., Ford, M. D., Piomelli, U., Funk, C. D. The Murine Angiotensin II-Induced Abdominal Aortic Aneurysm Model: Rupture Risk and Inflammatory Progression Patterns. Front Pharmacol. 1 (9), (2010).
  23. Parker, G. J., et al. Experimentally-derived functional form for a population-averaged high-temporal-resolution arterial input function for dynamic contrast-enhanced MRI. Magn Reson Med. 56 (5), 993-1000 (2006).
  24. Tseng, W., Leong, X., Engleman, E. Orthotopic mouse model of colorectal cancer. J Vis Exp. (10), 484 (2007).
  25. Bhullar, J. S., et al. A true orthotopic gastric cancer murine model using electrocoagulation. J Am Coll Surg. 217 (1), 64-70 (2013).
check_url/fr/52641?article_type=t

Play Video

Citer Cet Article
Kim, H., Samuel, S., Totenhagen, J. W., Warren, M., Sellers, J. C., Buchsbaum, D. J. Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model. J. Vis. Exp. (98), e52641, doi:10.3791/52641 (2015).

View Video