Summary

Contrasto dinamico migliorato risonanza magnetica di un modello ortotopico cancro del pancreas mouse

Published: April 18, 2015
doi:

Summary

The goal of this protocol is to apply dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) for orthotopic pancreatic tumor xenografts in mice. DCE-MRI is a non-invasive method to analyze microvasculature in a target tissue, and useful to assess vascular response in a tumor following a novel therapy.

Abstract

Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) has been limitedly used for orthotopic pancreatic tumor xenografts due to severe respiratory motion artifact in the abdominal area. Orthotopic tumor models offer advantages over subcutaneous ones, because those can reflect the primary tumor microenvironment affecting blood supply, neovascularization, and tumor cell invasion. We have recently established a protocol of DCE-MRI of orthotopic pancreatic tumor xenografts in mouse models by securing tumors with an orthogonally bent plastic board to prevent motion transfer from the chest region during imaging. The pressure by this board was localized on the abdominal area, and has not resulted in respiratory difficulty of the animals. This article demonstrates the detailed procedure of orthotopic pancreatic tumor modeling using small animals and DCE-MRI of the tumor xenografts. Quantification method of pharmacokinetic parameters in DCE-MRI is also introduced. The procedure described in this article will assist investigators to apply DCE-MRI for orthotopic gastrointestinal cancer mouse models.

Introduction

L'obiettivo generale di questo metodo è quello di applicare dinamico di contrasto maggiore risonanza magnetica (DCE-MRI) per ortotopici xenotrapianti tumorali pancreatiche nei topi. DCE-MRI è un metodo non invasivo per valutare microcircolo in un tessuto bersaglio monitorando la variazione di MR contrasto per un certo periodo di tempo dopo l'iniezione. DCE-MRI è stata utilizzata per diagnosticare tumori maligni e per valutare la risposta del tumore alle varie terapie 1-4. Quantitative DCE-MRI ha presentato alta riproducibilità 5. Per quantificare i parametri farmacocinetici di un agente di contrasto MR in un tessuto bersaglio, tutte le immagini DCE-MR acquisite in diversi momenti e T1 mappa ottenute prima iniezione di contrasto devono essere coregistrata 6. Tuttavia, a causa di movimenti respiratori e peristaltiche nella zona addominale, quantitativa DCE-MRI ha applicazione limitata per i tumori gastrointestinali.

Ortotopico modelli tumorali pancreatiche sono stati utilizzati per valutareRisposta pancreatico-tumorale a seguito di terapie biologiche e chemioterapie 7,8. Modelli tumorali ortotopico sono considerate superiori ai modelli sottocutanei convenzionali, poiché il microambiente nel sito del tumore originale viene riflessa e risposta tumorale umano così alla terapia può essere previsto con maggiore precisione. Tuttavia, il pancreas del mouse si trova nel quadrante in alto a sinistra dell'addome, in modo quantitativo DCE-MRI di ortotopici xenotrapianti tumorali pancreatiche nei topi non è stata immediatamente attuata.

Abbiamo stabilito un protocollo di DCE-MRI dei tumori addominali nei topi fissando i tumori utilizzando una scheda di plastica ortogonalmente piegato per impedire il trasferimento di movimento della regione toracica 9. La pressione applicata da questa tavola è stato localizzato sulla zona addominale, e non ha portato a difficoltà respiratoria. Una tecnica automatizzata immagine coregistrazione è stato convalidato per DCE-MRI di organi addominali in una modalità senza respiro, ma esegue effectively solo quando le regioni obiettivo si muovono lentamente e regolarmente 10. La frequenza respiratoria di animali è variabile durante l'imaging, ritenuta in modo fisico nella zona addominale sarà necessario recuperare i parametri farmacocinetici affidabili ortotopici modelli pancreatiche di topo tumore. Abbiamo quantificato con successo i parametri farmacocinetici di un agente di contrasto MR in ortotopici xenotrapianti tumorali pancreatiche usando la scheda di plastica ortogonalmente piegato in DCE-MRI 11-13. Ecco a voi la procedura dettagliata di ortotopica modellazione tumore pancreatico, DCE-MRI dei xenotrapianti tumorali nei topi, e la quantificazione dei parametri farmacocinetici.

Protocol

Tutte le procedure sono state approvate dalla cura e l'uso degli animali Comitato Istituzionale presso la University of Alabama a Birmingham. Modellazione 1. ortotopico pancreatica Tumor mouse Cultura linee standard di cellule del pancreas-tumorali umane in mezzo modificato Eagle Dulbecco (DMEM) addizionato con siero fetale bovino 10%. Mantenere tutte le culture a 37 ° C in atmosfera umidificata con 5% di CO 2. Utilizzare 8-10 femminili gravi topi immunod…

Representative Results

Cellule tumorali pancreatiche umane crescere con successo nel topo pancreas creazione di un tumore solido. La figura 1 mostra le fotografie di (A) un normale pancreas dove soluzione delle cellule tumorali viene iniettato, e (B) un mouse rappresentante recante un ortotopico xenotrapianto tumore pancreatico (MIA PaCa-2 ). Tumor si trova nel quadrante superiore sinistro dell'addome, accanto alla milza. Di solito ci vogliono 2-4 settimane per i tumori a crescere fino a 5-7 mm di diametro dopo l'impi…

Discussion

Abbiamo introdotto metodi dettagliati di modellazione ortotopico tumore pancreatico utilizzando topi immunodeficienti, DCE-MRI dei tumori addominali nei topi, e la quantificazione dei suoi parametri cinetici. In ortotopico modellazione tumore pancreatico, bisogna fare attenzione quando si inserisce un ago nella coda del pancreas. In caso di successo, le cellule saranno trasferiti alla testa del pancreas creare una piccola bozza. Quando si applica una scheda di plastica ortogonalmente piegato, è fondamentale per conferm…

Divulgations

The authors have nothing to disclose.

Acknowledgements

Authors thank Jeffrey Sellers to assist orthotopic pancreatic cancer mouse modeling. This work was supported by Research Initiative Pilot Awards from the Department of Radiology at UAB and NIH grants 2P30CA013148 and P50CA101955.

Materials

Name of Material/ Equipment Company Catalog Number Comments/Description
DMEM Invitrogen 11965-118
Fetal bovine serum Harlan Laboratories BT-9501
Betadine Purdue products 67618-153-01
5-0 Prolene sutures Ethicon 8720H
9.4T MR scanner Bruker Biospin Corporation BioSpec 94/20 USR
Gadoteridol Bracco Diagnostics Inc NDC 0270-1111-03
Micro-polyethelene tube Strategic Applications, Inc #PE-10-25
30G blunt tip needle Strategic Applications, Inc 89134-194
Monitoring and gating system SA instruments, Inc Model 1030 This is an MR compatiable system to measure resiratory rating and body temperature of small animals at the same time.
Syringe pump New Era Pump Systems, Inc. NE-1600

References

  1. Ergul, N., et al. Assessment of multifocality and axillary nodal involvement in early-stage breast cancer patients using 18F-FDG PET/CT compared to contrast-enhanced and diffusion-weighted magnetic resonance imaging and sentinel node biopsy. Acta Radiol. , (2014).
  2. Park, J. J., et al. Assessment of early response to concurrent chemoradiotherapy in cervical cancer: value of diffusion-weighted and dynamic contrast-enhanced MR imaging. Magn Reson Imaging. , (2014).
  3. Nguyen, H. T., et al. Prediction of chemotherapeutic response in bladder cancer using K-means clustering of dynamic contrast-enhanced (DCE)-MRI pharmacokinetic parameters. J Magn Reson Imaging. 10, (2014).
  4. Teo, Q. Q., Thng, C. H., Koh, T. S., Ng, Q. S. Dynamic Contrast-enhanced Magnetic Resonance Imaging: Applications in Oncology. Clin Oncol (R Coll Radiol). , (2014).
  5. Zhang, X., Pagel, M. D., Baker, A. F., Gillies, R. J. Reproducibility of magnetic resonance perfusion imaging. PLoS One. 9 (2), e89797 (2014).
  6. Kim, H., et al. Pancreatic adenocarcinoma: a pilot study of quantitative perfusion and diffusion-weighted breath-hold magnetic resonance imaging. Abdominal imaging. , (2014).
  7. Derosier, L. C., et al. Combination Treatment with TRA-8 Anti Death Receptor 5 Antibody and CPT-11 Induces Tumor Regression in an Orthotopic Model of Pancreatic Cancer. Clin Cancer Res. 13 (18), 5535s-5543s (2007).
  8. Derosier, L. C., et al. TRA-8 anti-DR5 monoclonal antibody and gemcitabine induce apoptosis and inhibit radiologically validated orthotopic pancreatic tumor growth. Mol Cancer Ther. 6 (12), 3198-3207 (2007).
  9. Kim, H., et al. Early therapy evaluation of combined anti-death receptor 5 antibody and gemcitabine in orthotopic pancreatic tumor xenografts by diffusion-weighted magnetic resonance imaging. Cancer Res. 68 (20), 8369-8376 (2008).
  10. Klein, S., Staring, M., Murphy, K., Viergever, M. A., Pluim, J. P. elastix: a toolbox for intensity-based medical image registration. IEEE Trans Med Imaging. 29 (1), 196-205 (2010).
  11. Kim, H., et al. Early therapy evaluation of combined cetuximab and irinotecan in orthotopic pancreatic tumor xenografts by dynamic contrast-enhanced magnetic resonance imaging. Mol Imaging. 10 (3), 153-167 (2011).
  12. Kim, H., et al. Antagonistic effects of anti-EMMPRIN antibody when combined with chemotherapy against hypovascular pancreatic cancers. M Mol Imaging Biol. 16 (1), 85-94 (2014).
  13. Kim, H., et al. Dual combination therapy targeting DR5 and EMMPRIN in pancreatic adenocarcinoma. Mol Cancer Ther. 11 (2), 405-415 (2012).
  14. Moyher, S. E., Vigneron, D. B., Nelson, S. J. Surface coil MR imaging of the human brain with an analytic reception profile correction. J Magn Reson Imaging. 5 (2), 139-144 (1995).
  15. Voigt, T., Nehrke, K., Doessel, O., Katscher, U. T1 corrected B1 mapping using multi-TR gradient echo sequences. Magn Reson Med. 64 (3), 725-733 (2010).
  16. Liu, H., Liu, Y., Zhao, Z., Zhang, L., Qiu, T. A new background distribution-based active contour model for three-dimensional lesion segmentation in breast DCE-MRI. Medical physics. 41 (8), 082303 (2014).
  17. Sarkar, S., Das, S. Multilevel image thresholding based on 2D histogram and maximum Tsallis entropy–a differential evolution approach. IEEE Trans Image Process. 22 (12), 4788-4797 (2013).
  18. Yankeelov, T. E., et al. Quantitative pharmacokinetic analysis of DCE-MRI data without an arterial input function: a reference region model. Magn Reson Imaging. 23 (4), 519-529 (2005).
  19. Cardenas-Rodriguez, J., Howison, C. M., Pagel, M. D. A linear algorithm of the reference region model for DCE-MRI is robust and relaxes requirements for temporal resolution. Magn Reson Imaging. 31 (4), 497-507 (2013).
  20. Tofts, P. S., et al. Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols. J Magn Reson Imaging. 10 (3), 223-232 (1999).
  21. Yankeelov, T. E., et al. Comparison of a reference region model with direct measurement of an AIF in the analysis of DCE-MRI data. Magn Reson Med. 57 (2), 353-361 (2007).
  22. Cao, R. Y., Amand, T., Ford, M. D., Piomelli, U., Funk, C. D. The Murine Angiotensin II-Induced Abdominal Aortic Aneurysm Model: Rupture Risk and Inflammatory Progression Patterns. Front Pharmacol. 1 (9), (2010).
  23. Parker, G. J., et al. Experimentally-derived functional form for a population-averaged high-temporal-resolution arterial input function for dynamic contrast-enhanced MRI. Magn Reson Med. 56 (5), 993-1000 (2006).
  24. Tseng, W., Leong, X., Engleman, E. Orthotopic mouse model of colorectal cancer. J Vis Exp. (10), 484 (2007).
  25. Bhullar, J. S., et al. A true orthotopic gastric cancer murine model using electrocoagulation. J Am Coll Surg. 217 (1), 64-70 (2013).
check_url/fr/52641?article_type=t

Play Video

Citer Cet Article
Kim, H., Samuel, S., Totenhagen, J. W., Warren, M., Sellers, J. C., Buchsbaum, D. J. Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model. J. Vis. Exp. (98), e52641, doi:10.3791/52641 (2015).

View Video