Summary

Dynamic Contrast mejorada de imagen de resonancia magnética de un modelo ortotópico de cáncer pancreático del ratón

Published: April 18, 2015
doi:

Summary

The goal of this protocol is to apply dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) for orthotopic pancreatic tumor xenografts in mice. DCE-MRI is a non-invasive method to analyze microvasculature in a target tissue, and useful to assess vascular response in a tumor following a novel therapy.

Abstract

Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) has been limitedly used for orthotopic pancreatic tumor xenografts due to severe respiratory motion artifact in the abdominal area. Orthotopic tumor models offer advantages over subcutaneous ones, because those can reflect the primary tumor microenvironment affecting blood supply, neovascularization, and tumor cell invasion. We have recently established a protocol of DCE-MRI of orthotopic pancreatic tumor xenografts in mouse models by securing tumors with an orthogonally bent plastic board to prevent motion transfer from the chest region during imaging. The pressure by this board was localized on the abdominal area, and has not resulted in respiratory difficulty of the animals. This article demonstrates the detailed procedure of orthotopic pancreatic tumor modeling using small animals and DCE-MRI of the tumor xenografts. Quantification method of pharmacokinetic parameters in DCE-MRI is also introduced. The procedure described in this article will assist investigators to apply DCE-MRI for orthotopic gastrointestinal cancer mouse models.

Introduction

El objetivo general de este método consiste en aplicar un mayor contraste de imagen dinámica de resonancia magnética (RM-RT) para xenoinjertos de tumores pancreáticos ortotópico en ratones. DCE-MRI es un método no invasivo para evaluar la microvasculatura en un tejido diana mediante la supervisión del cambio de contraste MR durante un cierto período de tiempo después de la inyección. DCE-MRI se ha utilizado para diagnosticar los tumores malignos y para evaluar la respuesta del tumor a diversas terapias 1-4. Cuantitativa DCE-MRI ha presentado una alta reproducibilidad 5. Para cuantificar los parámetros farmacocinéticos de un agente de contraste MR en un tejido diana, todas las imágenes DCE-MR adquiridos en diferentes puntos temporales y mapa T1 obtenidas antes de la inyección de contraste deben ser corregistrados 6. Sin embargo, debido a los movimientos respiratorios y peristálticas en la zona abdominal, cuantitativa DCE-MRI ha tenido una aplicación limitada para los tumores gastrointestinales.

Se han utilizado modelos de tumores de páncreas ortotópico para evaluarrespuesta de páncreas-tumor siguientes terapias biológicas y las quimioterapias 7,8. Modelos de tumores ortotópicos se consideran superiores a los modelos subcutáneos convencionales, puesto que el microambiente en el sitio del tumor original se refleja y de ese modo la respuesta del tumor a la terapia humana se puede predecir con más precisión. Sin embargo, el páncreas del ratón se encuentra en el cuadrante superior izquierdo del abdomen, por lo cuantitativo DCE-MRI de ortotópico xenoinjertos de tumores pancreáticos en ratones no se ha aplicado fácilmente.

Hemos establecido un protocolo de DCE-MRI de los tumores abdominales en ratones mediante la fijación de los tumores usando un tablero plástico ortogonalmente doblada para evitar la transferencia de movimiento de la región del pecho 9. La presión aplicada por este tablero fue localizado en el área abdominal, y no ha dado lugar a dificultad respiratoria. Una técnica automatizada imagen coregistration ha sido validado para DCE-MRI de los órganos abdominales en un modo sin respiración, pero realiza effectively sólo cuando las regiones objetivo se mueve lenta y regularmente 10. La frecuencia respiratoria de los animales es variable durante la exploración, la restricción de manera física en la zona abdominal será necesario recuperar los parámetros farmacocinéticos fiables en modelos de ratón de tumores pancreáticos ortotópico. Hemos cuantificado con éxito los parámetros farmacocinéticos de un agente de contraste MR en ortotópico xenoinjertos tumorales pancreáticas utilizando el tablero plástico ortogonalmente doblada en DCE-MRI 11-13. Aquí presentamos el procedimiento detallado de modelado tumor pancreático ortotópico, DCE-MRI de los xenoinjertos de tumores en ratones, y la cuantificación de los parámetros farmacocinéticos.

Protocol

Todos los procedimientos fueron aprobados por el Comité de Cuidado y Uso de Animales Institucional de la Universidad de Alabama en Birmingham. Modelado 1. ortotópico tumor pancreático Ratón Cultura líneas estándar de células de páncreas-cáncer humano en medio de Eagle modificado por Dulbecco (DMEM) suplementado con suero bovino fetal al 10%. Mantener todas las culturas a 37 ° C en atmósfera húmeda con 5% de CO 2. Utilice 8-10 ratones graves femenin…

Representative Results

Células tumorales pancreáticas humanas crecen con éxito en páncreas de ratón creando un tumor sólido. La figura 1 muestra fotografías de (A) un páncreas normal donde se inyecta solución de células de tumor, y (B) un ratón representativo que lleva un xenoinjerto de tumor de páncreas ortotópico (MIA PaCa-2 ). Tumor está localizado en el cuadrante superior izquierdo del abdomen, al lado del bazo. Por lo general toma 2-4 semanas para que los tumores crezcan hasta 5-7 mm de diámetro después d…

Discussion

Hemos introducido los métodos detallados de modelado tumor pancreático ortotópico utilizando ratones inmunodeficientes, DCE-MRI de los tumores abdominales en ratones, y la cuantificación de sus parámetros cinéticos. En el modelado tumor pancreático ortotópico, se debe tener cuidado cuando se inserta una aguja en la cola del páncreas. Si tiene éxito, las células se transfieren a la cabeza de páncreas creando una pequeña ampolla. Cuando se aplica una tabla de plástico ortogonalmente doblada, es fundamental p…

Divulgations

The authors have nothing to disclose.

Acknowledgements

Authors thank Jeffrey Sellers to assist orthotopic pancreatic cancer mouse modeling. This work was supported by Research Initiative Pilot Awards from the Department of Radiology at UAB and NIH grants 2P30CA013148 and P50CA101955.

Materials

Name of Material/ Equipment Company Catalog Number Comments/Description
DMEM Invitrogen 11965-118
Fetal bovine serum Harlan Laboratories BT-9501
Betadine Purdue products 67618-153-01
5-0 Prolene sutures Ethicon 8720H
9.4T MR scanner Bruker Biospin Corporation BioSpec 94/20 USR
Gadoteridol Bracco Diagnostics Inc NDC 0270-1111-03
Micro-polyethelene tube Strategic Applications, Inc #PE-10-25
30G blunt tip needle Strategic Applications, Inc 89134-194
Monitoring and gating system SA instruments, Inc Model 1030 This is an MR compatiable system to measure resiratory rating and body temperature of small animals at the same time.
Syringe pump New Era Pump Systems, Inc. NE-1600

References

  1. Ergul, N., et al. Assessment of multifocality and axillary nodal involvement in early-stage breast cancer patients using 18F-FDG PET/CT compared to contrast-enhanced and diffusion-weighted magnetic resonance imaging and sentinel node biopsy. Acta Radiol. , (2014).
  2. Park, J. J., et al. Assessment of early response to concurrent chemoradiotherapy in cervical cancer: value of diffusion-weighted and dynamic contrast-enhanced MR imaging. Magn Reson Imaging. , (2014).
  3. Nguyen, H. T., et al. Prediction of chemotherapeutic response in bladder cancer using K-means clustering of dynamic contrast-enhanced (DCE)-MRI pharmacokinetic parameters. J Magn Reson Imaging. 10, (2014).
  4. Teo, Q. Q., Thng, C. H., Koh, T. S., Ng, Q. S. Dynamic Contrast-enhanced Magnetic Resonance Imaging: Applications in Oncology. Clin Oncol (R Coll Radiol). , (2014).
  5. Zhang, X., Pagel, M. D., Baker, A. F., Gillies, R. J. Reproducibility of magnetic resonance perfusion imaging. PLoS One. 9 (2), e89797 (2014).
  6. Kim, H., et al. Pancreatic adenocarcinoma: a pilot study of quantitative perfusion and diffusion-weighted breath-hold magnetic resonance imaging. Abdominal imaging. , (2014).
  7. Derosier, L. C., et al. Combination Treatment with TRA-8 Anti Death Receptor 5 Antibody and CPT-11 Induces Tumor Regression in an Orthotopic Model of Pancreatic Cancer. Clin Cancer Res. 13 (18), 5535s-5543s (2007).
  8. Derosier, L. C., et al. TRA-8 anti-DR5 monoclonal antibody and gemcitabine induce apoptosis and inhibit radiologically validated orthotopic pancreatic tumor growth. Mol Cancer Ther. 6 (12), 3198-3207 (2007).
  9. Kim, H., et al. Early therapy evaluation of combined anti-death receptor 5 antibody and gemcitabine in orthotopic pancreatic tumor xenografts by diffusion-weighted magnetic resonance imaging. Cancer Res. 68 (20), 8369-8376 (2008).
  10. Klein, S., Staring, M., Murphy, K., Viergever, M. A., Pluim, J. P. elastix: a toolbox for intensity-based medical image registration. IEEE Trans Med Imaging. 29 (1), 196-205 (2010).
  11. Kim, H., et al. Early therapy evaluation of combined cetuximab and irinotecan in orthotopic pancreatic tumor xenografts by dynamic contrast-enhanced magnetic resonance imaging. Mol Imaging. 10 (3), 153-167 (2011).
  12. Kim, H., et al. Antagonistic effects of anti-EMMPRIN antibody when combined with chemotherapy against hypovascular pancreatic cancers. M Mol Imaging Biol. 16 (1), 85-94 (2014).
  13. Kim, H., et al. Dual combination therapy targeting DR5 and EMMPRIN in pancreatic adenocarcinoma. Mol Cancer Ther. 11 (2), 405-415 (2012).
  14. Moyher, S. E., Vigneron, D. B., Nelson, S. J. Surface coil MR imaging of the human brain with an analytic reception profile correction. J Magn Reson Imaging. 5 (2), 139-144 (1995).
  15. Voigt, T., Nehrke, K., Doessel, O., Katscher, U. T1 corrected B1 mapping using multi-TR gradient echo sequences. Magn Reson Med. 64 (3), 725-733 (2010).
  16. Liu, H., Liu, Y., Zhao, Z., Zhang, L., Qiu, T. A new background distribution-based active contour model for three-dimensional lesion segmentation in breast DCE-MRI. Medical physics. 41 (8), 082303 (2014).
  17. Sarkar, S., Das, S. Multilevel image thresholding based on 2D histogram and maximum Tsallis entropy–a differential evolution approach. IEEE Trans Image Process. 22 (12), 4788-4797 (2013).
  18. Yankeelov, T. E., et al. Quantitative pharmacokinetic analysis of DCE-MRI data without an arterial input function: a reference region model. Magn Reson Imaging. 23 (4), 519-529 (2005).
  19. Cardenas-Rodriguez, J., Howison, C. M., Pagel, M. D. A linear algorithm of the reference region model for DCE-MRI is robust and relaxes requirements for temporal resolution. Magn Reson Imaging. 31 (4), 497-507 (2013).
  20. Tofts, P. S., et al. Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols. J Magn Reson Imaging. 10 (3), 223-232 (1999).
  21. Yankeelov, T. E., et al. Comparison of a reference region model with direct measurement of an AIF in the analysis of DCE-MRI data. Magn Reson Med. 57 (2), 353-361 (2007).
  22. Cao, R. Y., Amand, T., Ford, M. D., Piomelli, U., Funk, C. D. The Murine Angiotensin II-Induced Abdominal Aortic Aneurysm Model: Rupture Risk and Inflammatory Progression Patterns. Front Pharmacol. 1 (9), (2010).
  23. Parker, G. J., et al. Experimentally-derived functional form for a population-averaged high-temporal-resolution arterial input function for dynamic contrast-enhanced MRI. Magn Reson Med. 56 (5), 993-1000 (2006).
  24. Tseng, W., Leong, X., Engleman, E. Orthotopic mouse model of colorectal cancer. J Vis Exp. (10), 484 (2007).
  25. Bhullar, J. S., et al. A true orthotopic gastric cancer murine model using electrocoagulation. J Am Coll Surg. 217 (1), 64-70 (2013).
check_url/fr/52641?article_type=t

Play Video

Citer Cet Article
Kim, H., Samuel, S., Totenhagen, J. W., Warren, M., Sellers, J. C., Buchsbaum, D. J. Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model. J. Vis. Exp. (98), e52641, doi:10.3791/52641 (2015).

View Video