Summary

Dynamisk kontrast Förbättrad Magnetic Resonance Imaging av en Orthotopic bukspottkörtelcancer musmodell

Published: April 18, 2015
doi:

Summary

The goal of this protocol is to apply dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) for orthotopic pancreatic tumor xenografts in mice. DCE-MRI is a non-invasive method to analyze microvasculature in a target tissue, and useful to assess vascular response in a tumor following a novel therapy.

Abstract

Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) has been limitedly used for orthotopic pancreatic tumor xenografts due to severe respiratory motion artifact in the abdominal area. Orthotopic tumor models offer advantages over subcutaneous ones, because those can reflect the primary tumor microenvironment affecting blood supply, neovascularization, and tumor cell invasion. We have recently established a protocol of DCE-MRI of orthotopic pancreatic tumor xenografts in mouse models by securing tumors with an orthogonally bent plastic board to prevent motion transfer from the chest region during imaging. The pressure by this board was localized on the abdominal area, and has not resulted in respiratory difficulty of the animals. This article demonstrates the detailed procedure of orthotopic pancreatic tumor modeling using small animals and DCE-MRI of the tumor xenografts. Quantification method of pharmacokinetic parameters in DCE-MRI is also introduced. The procedure described in this article will assist investigators to apply DCE-MRI for orthotopic gastrointestinal cancer mouse models.

Introduction

Det övergripande målet med denna metod är att använda dynamisk kontrastförstärkt magnetisk resonanstomografi (DCE-MRI) för orthotopic pankreas tumörxenotransplantat hos möss. DCE-MRI är en icke-invasiv metod för att bedöma mikrovaskulatur i en målvävnad genom att övervaka förändringen av MR kontrast under en viss tidsperiod efter injektion. DCE-MRI har använts för att diagnostisera maligna tumörer och bedöma tumör svar på olika terapier 1-4. Kvantitativ DCE-MRI har present hög reproducerbarhet 5. Att kvantifiera farmakokinetiska parametrar för en MR-kontrastmedel i en målvävnad, måste alla DCE-MR-bilder som förvärvats vid olika tidpunkter och T1 karta erhållits före kontrastinjektion vara coregistered 6. Men på grund av respiratoriska och peristaltiska rörelser i buken, har kvantitativ DCE-MRI haft begränsad ansökan om gastrointestinala tumörer.

Orthotopic pankreastumörmodeller har använts för att utvärderapankreas-tumörrespons efter biologiska terapier och kemoterapi 7,8. Orthotopic tumörmodeller anses överlägsen konventionella subkutana modeller, eftersom mikro i originaltumörstället reflekteras och därmed mänskligt tumörterapisvar kan mer exakt förutsägas. Dock är musen bukspottkörteln ligger i den övre vänstra kvadranten av buken, så kvantitativ DCE-MRI för orthotopic pankreas tumörxenotransplantat i möss har inte lätt genomförts.

Vi har etablerat ett protokoll av DCE-MRI av buken tumörer hos möss genom fastställande av tumörer med hjälp av en ortogonalt böjd plastkortet för att förhindra rörelse överföring från bröstregionen 9. Trycket tillämpas av denna styrelse var lokaliserad på buken, och har inte resulterat i andningssvårigheter. En automatiserad bild coregistration teknik har validerats för DCE-MRI av bukorganen i en fri-andning läge, men den presterar effectively endast när målregionerna röra sig långsamt och regelbundet 10. Andningsfrekvens av djur är variabel under avbildning, kommer så fysisk återhållsamhet i buken vara nödvändigt att hämta tillförlitliga farmakokinetiska parametrar i orthotopic pankreasmodeller tumör mus. Vi har framgångsrikt kvantifieras de farmakokinetiska parametrarna för en MR-kontrastmedel i orthotopic pankreas tumörxenografter använder ortogonalt böjda plastkortet i DCE-MRI 11-13. Här presenterar vi det detaljerade förfarandet för orthotopic pankreastumör modellering, DCE-MRI av tumörxenografter i möss och kvantifiering av farmakokinetiska parametrar.

Protocol

Alla förfaranden godkändes av Institutional Animal Care och användning kommittén vid University of Alabama i Birmingham. 1. Orthotopic pankreastumör Mouse Ling Kultur standard humana pankreascancercellinjer i Dulbeccos modifierade Eagles medium (DMEM) kompletterat med 10% fetalt bovint serum. Bibehåll alla kulturer vid 37 ° C i fuktad atmosfär med 5% CO2. Använd 8-10 veckor gamla kvinnliga svåra kombinerade immundefekta möss. Placera djurburar vid 1…

Representative Results

Mänskliga pankreastumörceller växa framgångsrikt i mus bukspottkörteln skapa en solid tumör. Figur 1 visar fotografier av (A) en normal bukspottkörteln där tumörcellslösning injiceras, och (B) ett representativt mus som bär en orthotopic pankreastumör xenograft (MIA PaCa-2 ). Tumör är beläget i den övre vänstra kvadranten av buken, intill mjälten. Det brukar ta 2-4 veckor för tumörer att växa upp till 5-7 mm i diameter efter cellimplantation. Motion av o…

Discussion

Vi har infört de detaljerade metoder för orthotopic pankreastumör modellering använder immundefekta möss, DCE-MRI av buken tumörer hos möss, och kvantifiering av dess kinetiska parametrar. I orthotopic pankreastumör modellering, måste man vara försiktig när du sätter en nål i svansen av bukspottkörteln. Om det lyckas, kommer cellerna att överföras till chefen för bukspottkörteln skapa en liten Bleb. Vid tillämpning ett ortogonalt böjd plastkortet, är det viktigt att bekräfta att tumören är beläg…

Divulgations

The authors have nothing to disclose.

Acknowledgements

Authors thank Jeffrey Sellers to assist orthotopic pancreatic cancer mouse modeling. This work was supported by Research Initiative Pilot Awards from the Department of Radiology at UAB and NIH grants 2P30CA013148 and P50CA101955.

Materials

Name of Material/ Equipment Company Catalog Number Comments/Description
DMEM Invitrogen 11965-118
Fetal bovine serum Harlan Laboratories BT-9501
Betadine Purdue products 67618-153-01
5-0 Prolene sutures Ethicon 8720H
9.4T MR scanner Bruker Biospin Corporation BioSpec 94/20 USR
Gadoteridol Bracco Diagnostics Inc NDC 0270-1111-03
Micro-polyethelene tube Strategic Applications, Inc #PE-10-25
30G blunt tip needle Strategic Applications, Inc 89134-194
Monitoring and gating system SA instruments, Inc Model 1030 This is an MR compatiable system to measure resiratory rating and body temperature of small animals at the same time.
Syringe pump New Era Pump Systems, Inc. NE-1600

References

  1. Ergul, N., et al. Assessment of multifocality and axillary nodal involvement in early-stage breast cancer patients using 18F-FDG PET/CT compared to contrast-enhanced and diffusion-weighted magnetic resonance imaging and sentinel node biopsy. Acta Radiol. , (2014).
  2. Park, J. J., et al. Assessment of early response to concurrent chemoradiotherapy in cervical cancer: value of diffusion-weighted and dynamic contrast-enhanced MR imaging. Magn Reson Imaging. , (2014).
  3. Nguyen, H. T., et al. Prediction of chemotherapeutic response in bladder cancer using K-means clustering of dynamic contrast-enhanced (DCE)-MRI pharmacokinetic parameters. J Magn Reson Imaging. 10, (2014).
  4. Teo, Q. Q., Thng, C. H., Koh, T. S., Ng, Q. S. Dynamic Contrast-enhanced Magnetic Resonance Imaging: Applications in Oncology. Clin Oncol (R Coll Radiol). , (2014).
  5. Zhang, X., Pagel, M. D., Baker, A. F., Gillies, R. J. Reproducibility of magnetic resonance perfusion imaging. PLoS One. 9 (2), e89797 (2014).
  6. Kim, H., et al. Pancreatic adenocarcinoma: a pilot study of quantitative perfusion and diffusion-weighted breath-hold magnetic resonance imaging. Abdominal imaging. , (2014).
  7. Derosier, L. C., et al. Combination Treatment with TRA-8 Anti Death Receptor 5 Antibody and CPT-11 Induces Tumor Regression in an Orthotopic Model of Pancreatic Cancer. Clin Cancer Res. 13 (18), 5535s-5543s (2007).
  8. Derosier, L. C., et al. TRA-8 anti-DR5 monoclonal antibody and gemcitabine induce apoptosis and inhibit radiologically validated orthotopic pancreatic tumor growth. Mol Cancer Ther. 6 (12), 3198-3207 (2007).
  9. Kim, H., et al. Early therapy evaluation of combined anti-death receptor 5 antibody and gemcitabine in orthotopic pancreatic tumor xenografts by diffusion-weighted magnetic resonance imaging. Cancer Res. 68 (20), 8369-8376 (2008).
  10. Klein, S., Staring, M., Murphy, K., Viergever, M. A., Pluim, J. P. elastix: a toolbox for intensity-based medical image registration. IEEE Trans Med Imaging. 29 (1), 196-205 (2010).
  11. Kim, H., et al. Early therapy evaluation of combined cetuximab and irinotecan in orthotopic pancreatic tumor xenografts by dynamic contrast-enhanced magnetic resonance imaging. Mol Imaging. 10 (3), 153-167 (2011).
  12. Kim, H., et al. Antagonistic effects of anti-EMMPRIN antibody when combined with chemotherapy against hypovascular pancreatic cancers. M Mol Imaging Biol. 16 (1), 85-94 (2014).
  13. Kim, H., et al. Dual combination therapy targeting DR5 and EMMPRIN in pancreatic adenocarcinoma. Mol Cancer Ther. 11 (2), 405-415 (2012).
  14. Moyher, S. E., Vigneron, D. B., Nelson, S. J. Surface coil MR imaging of the human brain with an analytic reception profile correction. J Magn Reson Imaging. 5 (2), 139-144 (1995).
  15. Voigt, T., Nehrke, K., Doessel, O., Katscher, U. T1 corrected B1 mapping using multi-TR gradient echo sequences. Magn Reson Med. 64 (3), 725-733 (2010).
  16. Liu, H., Liu, Y., Zhao, Z., Zhang, L., Qiu, T. A new background distribution-based active contour model for three-dimensional lesion segmentation in breast DCE-MRI. Medical physics. 41 (8), 082303 (2014).
  17. Sarkar, S., Das, S. Multilevel image thresholding based on 2D histogram and maximum Tsallis entropy–a differential evolution approach. IEEE Trans Image Process. 22 (12), 4788-4797 (2013).
  18. Yankeelov, T. E., et al. Quantitative pharmacokinetic analysis of DCE-MRI data without an arterial input function: a reference region model. Magn Reson Imaging. 23 (4), 519-529 (2005).
  19. Cardenas-Rodriguez, J., Howison, C. M., Pagel, M. D. A linear algorithm of the reference region model for DCE-MRI is robust and relaxes requirements for temporal resolution. Magn Reson Imaging. 31 (4), 497-507 (2013).
  20. Tofts, P. S., et al. Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols. J Magn Reson Imaging. 10 (3), 223-232 (1999).
  21. Yankeelov, T. E., et al. Comparison of a reference region model with direct measurement of an AIF in the analysis of DCE-MRI data. Magn Reson Med. 57 (2), 353-361 (2007).
  22. Cao, R. Y., Amand, T., Ford, M. D., Piomelli, U., Funk, C. D. The Murine Angiotensin II-Induced Abdominal Aortic Aneurysm Model: Rupture Risk and Inflammatory Progression Patterns. Front Pharmacol. 1 (9), (2010).
  23. Parker, G. J., et al. Experimentally-derived functional form for a population-averaged high-temporal-resolution arterial input function for dynamic contrast-enhanced MRI. Magn Reson Med. 56 (5), 993-1000 (2006).
  24. Tseng, W., Leong, X., Engleman, E. Orthotopic mouse model of colorectal cancer. J Vis Exp. (10), 484 (2007).
  25. Bhullar, J. S., et al. A true orthotopic gastric cancer murine model using electrocoagulation. J Am Coll Surg. 217 (1), 64-70 (2013).
check_url/fr/52641?article_type=t

Play Video

Citer Cet Article
Kim, H., Samuel, S., Totenhagen, J. W., Warren, M., Sellers, J. C., Buchsbaum, D. J. Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model. J. Vis. Exp. (98), e52641, doi:10.3791/52641 (2015).

View Video