Summary

分析マイクロ流体デバイスの熱測定技術

Published: June 03, 2015
doi:

Summary

Here, we present three protocols for thermal measurements in microfluidic devices.

Abstract

Thermal measurement techniques have been used for many applications such as thermal characterization of materials and chemical reaction detection. Micromachining techniques allow reduction of the thermal mass of fabricated structures and introduce the possibility to perform high sensitivity thermal measurements in the micro-scale and nano-scale devices. Combining thermal measurement techniques with microfluidic devices allows performing different analytical measurements with low sample consumption and reduced measurement time by integrating the miniaturized system on a single chip. The procedures of thermal measurement techniques for particle detection, material characterization, and chemical detection are introduced in this paper.

Introduction

三つの異なるマイクロスケールの熱測定技術は、この資料に示されています。マイクロ流体デバイスの三つの異なる構成は、熱粒子検出(TPD)、熱特性(熱伝導率および比熱)と、化学反応との相互作用の比色検出のために使用されます。

熱粒子検出

マイクロ流体デバイス中の粒子を検出し、カウントが広く、環境、産業、および生物学的用途1に使用されます。 TPDは、マイクロ流体デバイス2の熱測定の新たなアプリケーションの1つです。粒子サイズに基づいて粒子を検出および計数するための熱伝達を使用すると、システムの複雑さ、コスト、およびサイズ​​を減少させます。他の方法では、複雑な光学部品や複雑な電気的測定及び高度な信号処理ソフトウェアは、粒子を検出するために使用されます。

熱キャラマイクロカロリメータを用いた液体物質のcterization

液体試料熱特性は、マイクロ流体デバイス内の熱測定の第二のアプリケーションです。マイクロスケールの熱量測定を実行すること、サンプル消費量を低減し、従来のバルク熱量測定法と比較してより高い再現性を提供することにより、精度を増加させます。オンチップマイクロ熱量計装置を用いて熱伝導率および比熱を測定するための手順は、他の場所3に提示されています。熱伝導率測定のための熱の浸透時間の技術とマイクロ流体デバイスにおける比熱測定用の熱波解析(TWA)の詳細については、プロトコルの項に記載されています。

紙ベースのマイクロ流体デバイスにおける比色バイオケミカル検出

熱測定の別の用途は、紙ベースのマイクロ流体工学における生化学的検出です。での毛管作用紙の多孔質構造は、液体を搬送し、マイクロチャネル内の気泡の開始の問題を回避します。紙ベースのマイクロ流体デバイスの中で最も一般的な検出機構は、光学的又は電気化学的技術です。光学的検出は非常に複雑に悩まさ、高度な画像処理ソフトウェアの必要性が検出された信号を量子化します。それらは唯一の活性副生成物を生成する反応に適用することができるので、電気化学的検出も限られています。最近導入された比色紙ベースの生化学センサープラットフォーム4は、紙ベースのマイクロ流体システムおよびラベルフリー熱検出機構を利用しています。紙ベースのマイクロ流体プラットフォームでグルコースオキシダーゼ(GOD)酵素を用いたグルコースの比色検出の手順は、プロトコルセクションに示されています。

本稿の目的は、マイクロ流体デバイスの熱測定技術の能力を実証することです。デバイスpreparationは、液体試料取り扱いおよび抵抗温度検出器(RTD)センサ励起及び測定は、次のセクションに示されています。

Protocol

1.熱粒子検出(TPD) 標準的な半導体加工技術2を用いて、微細加工によって薄膜シリコン窒化膜と内蔵温度センサを微細加工シリコンデバイスを準備します。脱イオン(DI)水で製造されたデバイスをすすぎます。 注意:熱粒子検出器、マイクロ流体デバイスの製造方法は、従来文献2に説明されます。 マイクロチャネルを有するポリジメチルシロキサン(P…

Representative Results

図3は、測定された熱信号のプロットを示します。対応する光学画像とビーズの存在下で生成した信号は、マイクロチャネル内の微小球PSビーズの検出に成功を示します。マイクロ流路を通過する液体の熱伝導率は、PSビーズの存在による変化しています。チャネルの熱伝導率の変化は、マイクロチャネル内の熱伝達に影響を及ぼしています。マイクロチャネル内の熱伝達の変化?…

Discussion

Different thermal measurement techniques in microfluidic devices and their respective setup procedures are presented in this work. These thermal measurement methods such as thermal conductivity monitoring, thermal penetration time, amplitude of AC thermal fluctuations, and amplitude measurement of the generated heat are used to detect specific substances and investigate different reactions and interactions.

The thermal time constant plays a key role in the aforementioned thermal measurement t…

Divulgations

The authors have nothing to disclose.

Acknowledgements

この仕事のための部分的な財政支援はウィスコンシン州ミルウォーキー(IIP-0968887)の大学とマルケット大学(IIP-0968844)に位置する給水用機器&政策に関する産業/大学共同研究センターを通じて、米国国立科学財団によって提供されました。私たちは役に立つ議論のためにグレン·M.ウォーカー、ウー·ジン·チャンとシャンカルラダクリシュナンに感謝します。

Materials

Polydimethylsiloxane (PDMS)  Dow Corning Sylgard 184
PS beads – 90 um  Corpuscular 100265
PS beads – 200 um  Corpuscular 100271
Glycerol SigmaAldrich G5516
GOD enzyme SigmaAldrich G7141
Glucose Control Solution-Low Bayer contour Low Control
Glucose Control Solution-Normal Bayer contour Normal Control
Glucose Control Solution-High Bayer contour High Control
Chromatography filter paper Whatman 3001-845
Glass VWR  48393-106
Acrylic Film Nitto Denko 5600
Glass syringe (1 mL) Hamilton 1001
Syringe pump New Era NE-500
knife plotter Silhouette portrait
Current Preamplifier Stanford Research SR-570
Ocilloscope Agilent DSO 2420A
Signal Generator HP HP3324A
Lock-in Amplifire Stanford Research SRS-830
Source/meter 2400 Keithley 2400
Source/meter 2600 Keithley 2436A

References

  1. Zhang, H., Chon, C., Pan, X., Li, D. Methods for counting particles in microfluidic applications. Microfluid Nanofluid. 7 (6), 739-749 (2009).
  2. Vutha, A. K., Davaji, B., Lee, C. H., Walker, G. M. A microfluidic device for thermal particle detection. Microfluid Nanofluid. 17 (5), 871-878 (2014).
  3. Davaji, B., Bak, H. J., Chang, W. J., Lee, C. H. A Novel On-chip Three-dimensional Micromachined Calorimeter with Fully Enclosed and Suspended Thin-film Chamber for Thermal Characterization of Liquid Samples. Biomicrofluidics. 8 (3), 034101-034113 (2014).
  4. Davaji, B., Lee, C. H. A paper-based calorimetric microfluidics platform for bio-chemical sensing. Biosens. Bioelectron. 59, 120-126 (2014).
  5. Liu, J., et al. Process research of high aspect ratio microstructure using SU-8 resist. Microsystem Technologies. 10, 265-268 (2004).
  6. Dusen, M. S. V. Platinum-resistance thermometry at low temperatures. J. Am. Chem. Soc. 47 (2), 326-332 (1925).
  7. Arpaci, V. S. . Conduction Heat Transfer. , (1966).
  8. Garden, J. L., Chteau, E., Chaussy, J. Highly sensitive ac nanocalorimeter for microliter-scale liquids or biological samples. Appl. Phys. Lett. 84, 3597-3599 (2004).
  9. Kilo, C., et al. Evaluation of a New Blood Glucose Monitoring System with Auto-Calibration. Diabetes Technol. Ther. 7 (2), 283-294 (2005).
  10. Scheper, T. . Thermal Biosensors Bioactivity Bioaffinity (Advances in Biochemical Engineering/Biotechnology). , (1999).
check_url/fr/52828?article_type=t

Play Video

Citer Cet Article
Davaji, B., Lee, C. H. Thermal Measurement Techniques in Analytical Microfluidic Devices. J. Vis. Exp. (100), e52828, doi:10.3791/52828 (2015).

View Video