Summary

쥐 뇌의 일방적 인 북반구에 반복 경 두개 자기 자극

Published: October 22, 2016
doi:

Summary

We applied repetitive transcranial magnetic stimulation (rTMS) to the unilateral hemisphere of rat brain, by placing a 25-mm figure-8 coil 1 cm lateral to the vertex on the biauricular line and angulating the coil by 45°. An in-house water cooling system was used for rTMS for more than 20 min.

Abstract

Previous rodent models of repetitive transcranial magnetic stimulation (rTMS) adopted whole-brain stimulation instead of unilateral hemispheric rTMS, which is unlike the protocols used for human subjects. We report a successful application of rTMS to the unilateral hemisphere of rat brain. The rTMS was delivered with a low-frequency (1 Hz), high-frequency (20 Hz), or sham stimulation protocol to one side of the brain by using a small 25-mm figure-8 coil. We placed the center of the coil 1 cm lateral to the vertex on the biauricular line and angulated the coil 45° to the ground to minimize a potential direct effect of rTMS on the contralateral cortex. We also used an in-house water cooling system to enable repetitive magnetic stimulation for more than 20 min, even at a 20-Hz stimulation frequency. Increases in the transcriptions of immediate early genes (Arc, Junb, and Egr2) were greater after rTMS than after sham stimulation. After 5 consecutive days of 20-min 1-Hz rTMS, bdnf mRNA expression was significantly higher in stimulated cortex than in contralateral side. The model presented herein will elucidate the molecular mechanisms of rTMS by allowing analysis of the inter-hemispheric difference in its effect.

Introduction

반복적 인 경 두개 자기 자극 (RTMS), 비 침습적 뇌 자극 neuromodulation위한 도구, 예컨대 1,2- 중추 통증, 우울증 3, 4, 편두통, 심지어 5-7 뇌졸중과 같은 다양한 증상의 치료에 적용되어왔다. 머리가 대뇌 피질과 결과 신경 세포 활성화에 전기장을 유도에 신속하게 코일을 통해 전류를 변경. 대뇌 피질의 흥분이 자극이 종료 된 후 30 분 동안 지속될 수 RTMS에 의해 변조 될 수 있습니다.

후 효과 RTMS의 제안 메커니즘은 장기 강화 / 우울증 같은 효과 8, 이온 밸런스 9 과도 변화를 포함하고, 대사는 10을 변경합니다. 또한, 디 라자로 등의 알. 간헐적 세타 버스트 자극은 자극에 모두 기관의 신경 세포 삼각뿔하는 흥분성 시냅스 입력에 영향을 미치는 것이 좋습니다과 반대측 반구 (11).

중요한 제한은, 그러나, 임상 상황에 벤치 증거를 번역에서 연구를 방해했다. 우선, 이전 동물 연구에서, RTMS는 전체 뇌 자극 (12)을 사용 하였다. 전체 뇌 자극 인간 연구 9에 사용되는 프로토콜과 상당히 다르다. 또 다른 문제는, 자극 지속 기간과 관련이있다. 이것은 적어도 부분적으로 기인하는 효과적인 냉각 시스템이 과거의 작은 코일 사용할 있다는 사실이다.

최근 몇 년 동안, 정액 기사는 작은 동물의 뇌에 RTMS 실험에서 이러한 어려움을 극복하기위한 방법을 제안 발표되었다. 이러한 동물 모델에 의해, 쥐의 뇌는 낮은 주파수 RTMS (13)에 응답하여 인간에서와 유사한 대뇌 피질의 흥분의 변화를 보여준다 것으로 밝혀졌다. 더 중요한 것은, RTMS의 세포 및 분자 메커니즘은 점점 BEI 있습니다NG는 RTMS의 동물 모델을 이용하여 조사 하였다. 지점에있는 경우가 억제 interneuron의 구별 유형이 간헐적 세타 버스트 자극 (14)에 가장 민감한 것으로 알려져 있다는 점이다. RTMS의 설치류 모델은, 그러므로, RTMS에 의한 변화의 분자 토대에 많이 추구 질문을 탐구하는 새로운 기회를 제공합니다. RTMS 작은 동물 모델보다 실험실에서 사용될 수있는 경우 크게 가속이 분야에서 연구를 강화할 수있다.

우리는 지금 쥐의 뇌, 이전 작업 (15)의 확장의 일방적 인 반구에 RTMS을 적용하는 방법에 대해 설명합니다. 자극에 의한 변화는 자극을 대뇌 피질에서 RTMS에 의한 변화를 연구하기 위해 마이크로 양전자 방출 단층 촬영 (PET)와 mRNA의 마이크로 어레이를 사용하여 평가 하였다.

Protocol

동물을 사용하여 모든 절차를 검토하고 서울 대학교 병원의 기관 동물 관리 및 사용위원회에 의해 승인되었습니다. 1. 실험 설정 동물 준비 실험을 시작하기 전에 새로운 환경에 적응 수컷 흰쥐를 일주 허용. 참고 : 8 주 된 쥐가 본 연구에 사용되었지만, 현상 또는 성인 뇌 연구의 가설에 따라 선택 될 수있다. 유도 흡입 마취 유도 5 % 각각 챔버와 노?…

Representative Results

다섯 8 주령의 수컷 흰쥐는 MT 판정 별도 간 레이터 신뢰도 분석을 위해 사용 하였다. 근육 경련의 촉진을 사용하여, MTS는 두 개의 독립적 인 연구자들에 의해, 모든 쥐에서 얻을 수있는 각각 33.00 ± 4.21 % 최대 자극기 출력 (% MSO) 및 33.93 ± 0.88 % MSO로 측정 하였다. 개성 – 알트 바이어스는 -0.93이고, 계약의 95 % 한도는 7.26 %로 -9.13이었다. <p class="jove_content" fo:keep-together.within-p…

Discussion

본 연구의 주된 목적은 일방적 RTMS 동물 모델을 소개했다. 일방적 자극 RTMS 인간 연구의 가장 중요한 특징 중 하나이지만, 대부분의 연구는 작은 동물을 채용하지 않았다. 112.5 %와 133.3 % MT 자극은 동측과 반대측 유럽 의회 의원을 생산하는 반면, 로텐 버그 등. 15, 20mm의 외부 로브 직경 8 자형 코일을 사용하여 100 % MT의 자극과 반대측 유럽 의회 의원을 기록했다. 큰 유도 전기장이…

Divulgazioni

The authors have nothing to disclose.

Acknowledgements

This work was supported by the Korea Research Foundation Grant funded by the Korean Government (KRF-2008-313-E00458). The authors thank Jin-Joo Lee for the technical assistance.

Materials

Homeothermic blanket with a rectal probe Harvard apparatus 507222F
Isoflurane (Forane sol.) Choongwae
Propofol (Provive Inj. 1% 20ml) Claris Lifesciences
Repetitive magnetic stimulator (Magstim Rapid2) Magstim Company Ltd
25 mm figure-of-8 coil Magstim Company Ltd 1165-00
PET-CT GE Healthcare
QIAzol Lysis Reagent Qiagen (US Patent No. 5,346,994)
RNeasy Lipid Tissue Mini Kit Qiagen 74804
RNeasy Mini Spin Columns Qiagen (Mat No. 1011708)
Agilent 2100 Bioanalyzer Agilent Technologies
Ambion Illumina RNA amplification kit Ambion
Nanodrop Spectrophotometer NanoDrop ND-1000
Illumina RatRef-12 Expression BeadChip Illumina, Inc.
Amersham fluorolink streptavidin-Cy3 GE Healthcare Bio-Sciences

Riferimenti

  1. Lefaucheur, J. P., et al. Neurogenic pain relief by repetitive transcranial magnetic cortical stimulation depends on the origin and the site of pain. J Neurol Neurosurg Psychiatry. 75 (4), 612-616 (2004).
  2. Hirayama, A., et al. Reduction of intractable deafferentation pain by navigation-guided repetitive transcranial magnetic stimulation of the primary motor cortex. Pain. 122 (1-2), 22-27 (2006).
  3. O’Reardon, J. P., et al. Efficacy and safety of transcranial magnetic stimulation in the acute treatment of major depression: a multisite randomized controlled trial. Biol Psychiatry. 62 (11), 1208-1216 (2007).
  4. Brighina, F., et al. Facilitatory effects of 1 Hz rTMS in motor cortex of patients affected by migraine with aura. Exp Brain Res. 161 (1), 34-38 (2005).
  5. Lefaucheur, J. P. Stroke recovery can be enhanced by using repetitive transcranial magnetic stimulation (rTMS). Neurophysiol Clin. 36 (3), 105-115 (2006).
  6. Khedr, E. M., Ahmed, M. A., Fathy, N., Rothwell, J. C. Therapeutic trial of repetitive transcranial magnetic stimulation after acute ischemic stroke. Neurology. 65 (3), 466-468 (2005).
  7. Fregni, F., et al. A sham-controlled trial of a 5-day course of repetitive transcranial magnetic stimulation of the unaffected hemisphere in stroke patients. Stroke. 37 (8), 2115-2122 (2006).
  8. Pascual-Leone, A., Valls-Sole, J., Wassermann, E. M., Hallett, M. Responses to rapid-rate transcranial magnetic stimulation of the human motor cortex. Brain. 117 (4), 847-858 (1994).
  9. Ridding, M. C., Rothwell, J. C. Is there a future for therapeutic use of transcranial magnetic stimulation). Nat Rev Neurosci. 8 (7), 559-567 (2007).
  10. Valero-Cabre, A., Payne, B. R., Pascual-Leone, A. Opposite impact on 14C-2-deoxyglucose brain metabolism following patterns of high and low frequency repetitive transcranial magnetic stimulation in the posterior parietal cortex. Exp Brain Res. 176 (4), 603-615 (2007).
  11. Di Lazzaro, V., et al. The physiological basis of the effects of intermittent theta burst stimulation of the human motor cortex. J Physiol. 586 (16), 3871-3879 (2008).
  12. Post, A., Keck, M. E. Transcranial magnetic stimulation as a therapeutic tool in psychiatry: what do we know about the neurobiological mechanisms. J Psychiatr Res. 35 (4), 193-215 (2001).
  13. Muller, P. A., Dhamne, S. C., Vahabzadeh-Hagh, A. M., Pascual-Leone, A., Jensen, F. E., Rotenberg, A. Suppression of motor cortical excitability in anesthetized rats by low frequency repetitive transcranial magnetic stimulation. PLoS One. 9 (3), 91065 (2014).
  14. Funke, K., Benali, A. Modulation of cortical inhibition by rTMS – findings obtained from animal models. J Physiol. 589 (18), 4423-4435 (2011).
  15. Rotenberg, A., et al. Lateralization of forelimb motor evoked potentials by transcranial magnetic stimulation in rats. Clin Neurophysiol. 121 (1), 104-108 (2010).
  16. Beom, J., Kim, W., Han, T. R., Seo, K. S., Oh, B. M. Concurrent use of granulocyte-colony stimulating factor with repetitive transcranial magnetic stimulation did not enhance recovery of function in the early subacute stroke in rats. Neurol Sci. 36 (5), 771-777 (2015).
  17. Haghighi, S. S., Green, K. D., Oro, J. J., Drake, R. K., Kracke, G. R. Depressive effect of isoflurane anesthesia on motor evoked potentials. Neurosurgery. 26, 993-997 (1990).
  18. Fishback, A. S., Shields, C. B., Linden, R. D., Zhang, Y. P., Burke, D. The effects of propofol on rat transcranial magnetic motor evoked potentials. Neurosurgery. 37 (5), 969-974 (1995).
  19. Rohde, V., Krombach, G. A., Baumert, J. H., Kreitschmann-Andermahr, I., Weinzierl, M., Gilsbach, J. M. Measurement of motor evoked potentials following repetitive magnetic motor cortex stimulation during isoflurane or propofol anaesthesia. Br J Anaesth. 91 (4), 487-492 (2003).
  20. Lee, S. A., Oh, B. M., Kim, S. J., Paik, N. J. The molecular evidence of neural plasticity induced by cerebellar repetitive transcranial magnetic stimulation in the rat brain: a preliminary report. Neurosci Lett. 575, 47-52 (2014).
  21. Fu, Y. K., et al. Imaging of regional metabolic activity by (18)F-FDG/PET in rats with transient cerebral ischemia. Appl Radiat Isot. 67 (18), 1743-1747 (2009).
  22. Silveyra, P., Catalano, P. N., Lux-Lantos, V., Libertun, C. Impact of proestrous milieu on expression of orexin receptors and prepro-orexin in rat hypothalamus and hypophysis: actions of Cetrorelix and Nembutal. Am J Physiol Endocrinol Metab. 292 (3), 820-828 (2007).
  23. Zidek, N., Hellmann, J., Kramer, P. J., Hewitt, P. G. Acute hepatotoxicity: a predictive model based on focused illumina microarrays. Toxicol Sci. 99 (1), 289-302 (2007).
  24. Hsieh, T. H., Dhamne, S. C., Chen, J. J., Pascual-Leone, A., Jensen, F. E., Rotenberg, A. A new measure of cortical inhibition by mechanomyography and paired-pulse transcranial magnetic stimulation in unanesthetized rats. J Neurophysiol. 107 (3), 966-972 (2012).
  25. Salvador, R., Miranda, P. C. Transcranial magnetic stimulation of small animals: a modeling study of the influence of coil geometry, size and orientation. Conf Proc IEEE Eng Med Biol Soc. 2009, 674-677 (2009).
  26. Parthoens, J., Verhaeghe, J., Servaes, S., Miranda, A., Stroobants, S., Staelens, S. Performance Characterization of an Actively Cooled Repetitive Transcranial Magnetic Stimulation Coil for the Rat. Neuromodulation. , (2016).
  27. Toro, R., et al. Brain size and folding of the human cerebral cortex. Cereb Cortex. 18 (10), 2352-2357 (2008).
check_url/it/54217?article_type=t

Play Video

Citazione di questo articolo
Beom, J., Lee, J. C., Paeng, J. C., Han, T. R., Bang, M. S., Oh, B. Repetitive Transcranial Magnetic Stimulation to the Unilateral Hemisphere of Rat Brain. J. Vis. Exp. (116), e54217, doi:10.3791/54217 (2016).

View Video