Summary

Die Herstellung von Kleinkaliber Stentgrafts Mit Elektrospinnen und Balloon Expandable Bare Metal Stents

Published: October 26, 2016
doi:

Summary

In the protocol, we present a method to manufacture a small caliber stent-graft by sandwiching a balloon expandable stent between two electrospun nanofibrous polyurethane layers.

Abstract

Stent-grafts are widely used for the treatment of various conditions such as aortic lesions, aneurysms, emboli due to coronary intervention procedures and perforations in vasculature. Such stent-grafts are manufactured by covering a stent with a polymer membrane. An ideal stent-graft should have a biocompatible stent covered by a porous, thromboresistant, and biocompatible polymer membrane which mimics the extracellular matrix thereby promoting injury site healing. The goal of this protocol is to manufacture a small caliber stent-graft by encapsulating a balloon expandable stent within two layers of electrospun polyurethane nanofibers. Electrospinning of polyurethane has been shown to assist in healing by mimicking native extracellular matrix, thereby promoting endothelialization. Electrospinning polyurethane nanofibers on a slowly rotating mandrel enabled us to precisely control the thickness of the nanofibrous membrane, which is essential to achieve a small caliber balloon expandable stent-graft. Mechanical validation by crimping and expansion of the stent-graft has shown that the nanofibrous polyurethane membrane is sufficiently flexible to crimp and expand while staying patent without showing any signs of tearing or delamination. Furthermore, stent-grafts fabricated using the methods described here are capable of being implanted using a coronary intervention procedure using standard size guide catheters.

Introduction

Coronary Intervention Verfahren verursachen erhebliche Gefäßwand Verletzungen durch Unterbrechung der Plaque und Gefäßwand. Dies führt zu einer Restenose, periphere Embolien bei Venentransplantaten und Diskontinuität der koronaren Lumen 1-4. Um diese Komplikationen zu vermeiden, ist eine vielversprechende Strategie wird sein, die Gefäßoberfläche in der Angioplastie Ort zu decken, die möglicherweise Restenose hemmen, Risiken zu mindern von Diskontinuität von Gefäßlumen, und zu verhindern, periphere Embolie. Frühere Studien haben Bare – Metal – Stents im Vergleich zu Stentgrafts mit positiven Ergebnissen für Stent-Implantate 5. Die Forscher haben verschiedene Materialien verwendet, um Membranen herzustellen, die Stents zu decken. Dazu gehören synthetische Materialien wie Polyethylentetraphthalat (PET), Polytetrafluorethylen (PTFE), Polyurethan (PU) und Silizium oder autologe Gefäßgewebe ummantelte Stents herzustellen 6-9. Ein ideales Transplantatmaterial verwendet, um den Stent zu bedecken sollte thromboresistente, nicht biodegr werdenadable und sollte mit nativem Gewebe ohne übermäßige Vermehrung integrieren und Entzündung 10. Das Transplantatmaterial verwendet, um den Stent zu bedecken sollte auch die Heilung des Stent-Graft zu fördern.

Stent-Transplantate werden zur Behandlung von Aortenisthmusstenose weit verbreitet, Pseudo-Aneurysmen der Arteria carotis, arteriovenöse Fisteln, degeneriert Transplantate Vene und große bis hin zu riesigen zerebraler Aneurysmen. Aber die Entwicklung von kleinkalibrigen Stent-Transplantate wird durch die Fähigkeit begrenzt niedriges Profil zu erhalten und Flexibilität, die 11-14 in der Entfaltung des Stents-Grafts hilft. PU ist ein Elastomer – Polymer mit guter mechanischer Festigkeit , die für das Erreichen ein niedriges Profil und eine gute Flexibilität 15,16 ein gewünschtes Merkmal ist. Neben der guten Lieferfähigkeit hat, Stent-Implantate sollten auch eine schnelle Heilung und Endothelialisierung zu fördern. PU – beschichtet Stent-Implantate 17 bessere Biokompatibilität und verbesserte Endothelialisierung unter Beweis gestellt haben. Die Forscher habenzuvor versucht , PU – beschichtet Stent-Implantate zu endothelialisieren , indem sie mit Endothelzellen 17 Säen. Elektrospinnen von PU – Nanofaser – Matrix zu schaffen , hat sich gezeigt , eine wertvolle Technik zu sein , für die Herstellung von Gefäßtransplantaten 18,19. Die Existenz von Nanofasern, die die Architektur der nativen extrazellulären Matrix nachzuahmen ist auch bekannt , Endothelzellproliferation 20,21 zu fördern. Elektrospinnen ermöglicht auch die Kontrolle über die Dicke des Materials 22. Kleinkalibrigen Gefäßtransplantate aus PU wurden untersucht zur Förderung der Heilung von Modifikationen wie Oberflächenbeschichtungen, Antikoagulantien und Zellproliferationshemmer verwendet wird. All diese Änderungen sind so konzipiert , Host – Akzeptanz zu vermitteln und Transplantatheilung 23 fördern.

Unsere Gruppe hat einen Ballon erweiterbaren Bare – Metal – Stent entwickelt , die 24-26 in Tiermodellen eingesetzt werden kann. Die Kombination einer elektro Polyurethan mesh und einer Kugeloon Stent hat uns ermöglicht, kleinkalibrige Ballon erweiterbaren Stent-Implantate zu erzeugen. Die meisten der derzeit erhältlichen Stentgrafts werden durch die Oberschenkelarterie bei einem interventionellen Verfahren eingeführt, aber nur wenige kommerzielle Stents können 1 Französisch Größe größer ist als die für einen nicht aufgeblasenen Ballon 27 erforderlich eingeführt werden. In dieser Studie haben wir eine kleinkalibrige Gefäßstent-Transplantat durch Einkapseln eines Ballons aufweitbaren Stents zwischen zwei Schichten aus elektro PU entwickelt, die zu einer Koronararterie geliefert werden, um eine Standard 8-9 Französisch Führungskatheter in einem perkutanen Eingriff-Verfahren verwendet wird.

Protocol

1. Elektrospinnen von Polyurethan auf Mandrel Collector Bereiten Sie Dorn für Elektro Melt etwa 8 ml biokompatiblen, Lebensmittelqualität, wasserlösliche Trägermaterial in einem Messzylinder (ca. 9 mm Durchmesser und 110 mm tief) bei 155 ° C über einen Backofen verwenden. Tauche ein 3 mm Durchmesser und 100 mm langen Edelstahldorn mit einer Beschichtung aus Trägermaterial an der Oberfläche des Dorns zu erhalten. Vor dem Eintauchen, legen die Dorne i…

Representative Results

Unsere Electro Setup (Abbildung 1) wurde in hochwertigem Polyurethan – Nanofasern (Abbildung 2) geführt. Ein Stent-Transplantat wird durch Elektro eine innere Schicht aus Polyurethan auf einen Dorn, ein Verrutschen eines unbeschichteten Stent über dieser Schicht hergestellt, und eine zweite äußere Schicht aus Polyurethan Elektroverspinnen (Abbildung 3). Polyurethan-Nanofasern mit einer Geschwindigkeit von 50 um / h, elektroversponnen, die in einer inneren Schi…

Discussion

We have developed a fabrication technique for a small caliber stent-graft which can be deployed using a standard percutaneous coronary intervention (PCI) procedure. Stent-grafts currently available are limited in their ability to maintain a low profile and flexibility for deployment. Bare metal stents developed by our group in our previous studies have proven to assist in rapid healing of the stented artery24,26. Various polymers have been electrospun by other groups and polyurethane has been proven biostable …

Divulgazioni

The authors have nothing to disclose.

Acknowledgements

We would like to thank the Division of Engineering, Mayo Clinic for their technical support. This study was financially supported by European Regional Development Fund – FNUSA-ICRC (No. CZ.1.05/1.100/02.0123), National Institutes of Health (T32 HL007111), American Heart Association Scientist Development Grant (AHA #06-35185N), and The Grainger Innovation Fund – Grainger Foundation.

Materials

Glass syringe Air Tite 7.140-33 Syringe for spinneret
Graduated cylinder 5 mL Fisher Scientific 08-552-4G 5 mL pyrex graduated cylinder about 9mm diameter and 11 cm long
High voltage generator Bertan Accociates, Inc. 205A-30P Used to apply voltage difference across spinneret and collector
Laboratory mixer with rpm control Scilogex SCI-84010201 Available from various laboratory equipment suppliers
Polyurethane DSM BioSpan SPU Biospan Segmented Polyurethane
Rubber sheet McMaster Carr 1370N11 Used to insulate syringe during electrospinning
Stainless steel mandrel N/A N/A Manufactured 
Stainless steel needle Hamilton 91018 Used as spinneret in electrospinning
Support material EnvisionTec B04-HT-DEMOMAT Biocompatible water soluble material
Syringe Pump Harvard Apparatus 55-3333

Riferimenti

  1. Elsner, M., et al. Coronary stent grafts covered by a polytetrafluoroethylene membrane. Am. J. Cardiol. 84 (3), 335-338 (1999).
  2. Störger, H., Haase, J. Polytetrafluoroethylene-Covered Stents: Indications, Advantages, and Limitations. J. Interv. Cardiol. 12 (6), 451-456 (1999).
  3. Moreno, P. R., et al. Macrophage infiltration predicts restenosis after coronary intervention in patients with unstable angina. Circulation. 94 (12), 3098-3102 (1996).
  4. Briguori, C., Sarais, C., Colombo, A. The polytetrafluoroethylene-covered stent: a device with multiple potential advantages. Int. J. Cardiovasc. Interv. 4 (3), 145-149 (2001).
  5. Qureshi, M. A., Martin, Z., Greenberg, R. K. Endovascular management of patients with Takayasu arteritis: stents versus stent grafts. Semin. Vasc. Surg. 24 (1), 44-52 (2011).
  6. Ahmadi, R., Schillinger, M., Maca, T., Minar, E. Femoropopliteal arteries: immediate and long-term results with a Dacron-covered stent-graft. Radiology. 223 (2), 345-350 (2002).
  7. Geremia, G., et al. Experimental arteriovenous fistulas: treatment with silicone-covered metallic stents. AJNR. Am. J. Neuroradiol. 18 (2), 271-277 (1997).
  8. Saatci, I., et al. Treatment of internal carotid artery aneurysms with a covered stent: experience in 24 patients with mid-term follow-up results. AJNR. Am. J. Neuroradiol. 25 (10), 1742-1749 (2004).
  9. Stefanadis, C., et al. Stents Wrapped in Autologous Vein: An Experimental Study1. J. Am. Coll. Cardiol. 28 (4), 1039-1046 (1996).
  10. Palmaz, J. C. Review of polymeric graft materials for endovascular applications. J. Vasc. Interv. Radiol. 9, 7-13 (1998).
  11. Bruckheimer, E., Dagan, T., Amir, G., Birk, E. Covered Cheatham-Platinum stents for serial dilation of severe native aortic coarctation. Catheter Cardiovasc. Interv. 74 (1), 117-123 (2009).
  12. Tzifa, A., et al. Covered Cheatham-platinum stents for aortic coarctation: early and intermediate-term results. J. Am. Coll. Cardiol. 47 (7), 1457-1463 (2006).
  13. Kuraishi, K., et al. Development of nanofiber-covered stents using electrospinning: in vitro and acute phase in vivo experiments. J. Biomed. Mater. Res. Part B Appl. Biomater. 88 (1), 230-239 (2009).
  14. Pant, S., Bressloff, N. W., Limbert, G. Geometry parameterization and multidisciplinary constrained optimization of coronary stents. Biomech. Model Mechanobiol. 11 (1-2), 61-82 (2012).
  15. Muller-Hulsbeck, S., et al. Experience on endothelial cell adhesion on vascular stents and stent-grafts: first in vitro results. Invest. Radiol. 37 (6), 314-320 (2002).
  16. Sarkar, S., Salacinski, H. J., Hamilton, G., Seifalian, A. M. The mechanical properties of infrainguinal vascular bypass grafts: their role in influencing patency. Eur. J. Vasc. Endovasc. Surg. 31 (6), 627-636 (2006).
  17. Shirota, T., Yasui, H., Shimokawa, H., Matsuda, T. Fabrication of endothelial progenitor cell (EPC)-seeded intravascular stent devices and in vitro endothelialization on hybrid vascular tissue. Biomaterials. 24 (13), 2295-2302 (2003).
  18. Grasl, C., et al. Electrospun polyurethane vascular grafts: in vitro mechanical behavior and endothelial adhesion molecule expression. J. Biomed. Mater. Res. A. 93 (2), 716-723 (2010).
  19. Kidoaki, S., Kwon, I. K., Matsuda, T. Structural features and mechanical properties of in situ-bonded meshes of segmented polyurethane electrospun from mixed solvents. J. Biomed. Mater. Res. Part B Appl. Biomater. 76 (1), 219-229 (2006).
  20. Stegemann, J. P., Kaszuba, S. N., Rowe, S. L. Review: advances in vascular tissue engineering using protein-based biomaterials. Tissue Eng. 13 (11), 2601-2613 (2007).
  21. Sankaran, K. K., Subramanian, A., Krishnan, U. M., Sethuraman, S. Nanoarchitecture of scaffolds and endothelial cells in engineering small diameter vascular grafts. Biotechnol. J. 10 (1), 96-108 (2015).
  22. Gibson, P., Schreuder-Gibson, H., Rivin, D. Transport properties of porous membranes based on electrospun nanofibers. Colloid Surf., A. 187, 469-481 (2001).
  23. Zdrahala, R. J. Small caliber vascular grafts. Part II: Polyurethanes revisited. J. Biomater. Appl. 11 (1), 37-61 (1996).
  24. Uthamaraj, S., et al. Design and validation of a novel ferromagnetic bare metal stent capable of capturing and retaining endothelial cells. Ann. Biomed. Eng. 42 (12), 2416-2424 (2014).
  25. Tefft, B. J., et al. Cell Labeling and Targeting with Superparamagnetic Iron Oxide Nanoparticles. J. Vis. Exp. (105), e53099 (2015).
  26. Uthamaraj, S., et al. Ferromagnetic Bare Metal Stent for Endothelial Cell Capture and Retention. J. Vis. Exp. (103), e53100 (2015).
  27. de Giovanni, J. V. Covered stents in the treatment of aortic coarctation. J. Interv. Cardiol. 14 (2), 187-190 (2001).
  28. Hans, F. J., et al. Treatment of wide-necked aneurysms with balloon-expandable polyurethane-covered stentgrafts: experience in an animal model. Acta. Neurochir. (Wien). 147 (8), 871-876 (2005).
  29. Hasan, A., et al. Electrospun scaffolds for tissue engineering of vascular grafts. Acta. Biomater. 10 (1), 11-25 (2014).

Play Video

Citazione di questo articolo
Uthamaraj, S., Tefft, B. J., Jana, S., Hlinomaz, O., Kalra, M., Lerman, A., Dragomir-Daescu, D., Sandhu, G. S. Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents. J. Vis. Exp. (116), e54731, doi:10.3791/54731 (2016).

View Video