Summary

Optical coherence tomography (OCT) is a high resolution imaging technique that allows analysis of tissue specific optical properties providing the means for tissue differentiation. We developed needle based OCT, providing real-time imaging combined with on-the-spot tumor differentiation. This publication describes a method for percutaneous, needle based OCT of renal masses.

Abstract

Optical coherence tomography (OCT) is the optical equivalent of ultrasound imaging, based on the backscattering of near infrared light. OCT provides real time images with a 15 µm axial resolution at an effective tissue penetration of 2-3 mm. Within the OCT images the loss of signal intensity per millimeter of tissue penetration, the attenuation coefficient, is calculated. The attenuation coefficient is a tissue specific property, providing a quantitative parameter for tissue differentiation.

Until now, renal mass treatment decisions have been made primarily on the basis of MRI and CT imaging characteristics, age and comorbidity. However these parameters and diagnostic methods lack the finesse to truly detect the malignant potential of a renal mass. A successful core biopsy or fine needle aspiration provides objective tumor differentiation with both sensitivity and specificity in the range of 95-100%. However, a non-diagnostic rate of 10-20% overall, and even up to 30% in SRMs, is to be expected, delaying the diagnostic process due to the frequent necessity for additional biopsy procedures.

We aim to develop OCT into an optical biopsy, providing real-time imaging combined with on-the-spot tumor differentiation. This publication provides a detailed step-by-step approach for percutaneous, needle based, OCT of renal masses.

Introduction

העשורים האחרונים הראו עלייה מתמדת בשכיחות של המוני כליות 1,2. עד עכשיו, החלטות טיפול המוניות כליות נעשו בעיקר על בסיס מאפייני הדמיה MRI ו- CT, גיל והתחלואה נלווה. עם זאת שיטות אבחון ופרמטרים אלה קליניים חסרי העידון באמת לזהות את הפוטנציאל הממאיר של מסת כליה. ביופסית ליבה או שאיפת מחט עדינה עם רקמה מספיקה להערכה פתולוגית (אבחון) מספקת בידול אובייקטיבי של גידול עם שני רגיש וסגוליות בטווח של 95-100% 3. לכן ביופסיה היא להשיג הסכמה בהערכת המוני כליות חשודים 4,5. עם זאת, ביופסיות ללא רקמה מספיק כדי לקבוע אבחנה או עם נורמלי parenchyma כליות (לא אבחון) מתרחש בשיעור של 10-20% בסך הכל, ואפילו עד 30% בהמונים כליה קטנים (<4 סנטימטר, SRMs), לעכב תהליך האבחון בשל הצורך התכוף לנוסףביופסיות 3.5.

טומוגרפיה קוהרנטיות אופטית (אוקטובר) היא שיטת הדמיה רומן שיש לו את הפוטנציאל להתגבר על המכשולים האמורים בבידול מסת כליה. בהתבסס על backscattering של אור אינפרא אדום קרוב, אוקטובר מספק תמונות עם 15 מיקרומטר רזולוציה צירית בחדירת רקמה יעילה של 2-3 מ"מ (איור 1, 2). הפסד של עוצמת אות לכל מילימטר של חדירה לרקמות, כתוצאה של פיזור אור רקמות ספציפיות, כפי שבא לידי ביטוי במקדם הנחתה (μ אוקטובר: מ"מ -1) כפי שתואר על ידי et al Faber 6.. יכולים להיות מתואמים מאפיינים היסטולוגית לμ ערכי אוקטובר מתן פרמטר הכמותי לבידול רקמה (איור 3).

במהלך היווצרות הסרטן, תאים ממאירים להציג מספר גדל, גרעינים גדולים יותר ויותר בלתי סדיר בצורה עם מדד גבוה יותר שבירה ומיטוכונדריה פעילה יותר. בשל ביטוי יתר של מרכיבי תא, שינוי בμ אוקטובר הוא צפוי כאשר משווים גידולים ממאירים לגידולים שפירים או רקמה מושפעת 7.

לאחרונה למדנו את היכולת של אוקטובר השטחי להבחין בין המוני כליה שפירים וממאירים 8,9. ב -16 חולים, מדידות אוקטובר התוך-ניתוחיות של רקמת גידול התקבלו באמצעות בדיקה אוקטובר להציב חיצוני. זרוע השליטה מורכבת ממדידות אוקטובר של רקמה מושפעת באותם חולים. רקמה נורמלית הראתה מקדם הנחתה החציוני נמוכה באופן משמעותי בהשוואה לרקמה ממארת, המאשר את הפוטנציאל של אוקטובר לבידול גידול. ניתוח כמו זה יושם באופן דומה לסוגים אחרים של הכיתה רקמה ממארת, כגון קרצינומה urothelial 10,11 ובידול neoplasia אפיתל פות 12.

אף אוזן גרון "> אנו שואפים לפתח אוקטובר לביופסיה אופטית, מתן בשילוב הדמיה בזמן אמת עם בידול גידול ב- the-spot. מטרת המחקר הנוכחי היא לתאר מלעורית, מחט המבוססת, אוקטובר גישה בחולים שאובחנה עם מסת כליה שיפור מוצקה. תיאור שיטה זו הוא, למיטב ידיעתנו, הראשון להעריך את האפשרות של מחט אוקטובר מבוסס של גידולי כליה.

Protocol

ההליך הציג מתקיים תחת פרוטוקול מחקר שאושר על ידי מועצת המנהלים מוסדי הסקירה של המרכז הרפואי האקדמית באמסטרדם, מספר רישום NL41985.018. נכתב הסכמה מהדעת נדרש מכל המשתתפים. מערכת .1 לצורך ?…

Representative Results

בין 25 הגידולים הראשונים (23 חולים), בסך של 24 נהלים אוקטובר המוצלחים בוצע. במקרה אחד תקלה בדיקה הובילה לחוסר היכולת לרכוש סריקת OCT. שתי תופעות לוואי (AE) התרחש, שמתוארות בפירוט בסעיף הדיון. מאפייני חולים כלליים נמצאים בטבלה 1. ?…

Discussion

בפרסום זה אנו מדווחים על ההיתכנות של מלעורית, מחט, אוקטובר של הכליות מבוססות. זהו צעד ראשון חיוני בהתפתחות של אוקטובר לטכניקה קליני רלוונטית לבידול גידול, כפי שכונתה "אופטי ביופסיה". 25 החולים הראשונים שלנו הראו אוקטובר percutaneous להיות הליך קל ובטוח. יש ביופסיה אופט?…

Disclosures

The authors have nothing to disclose.

Acknowledgements

This work is funded by the Cure for Cancer Foundation, Dutch Technology Foundation (STW) and The Netherlands Organisation for Health Research and Development (ZonMw).

Materials

15G / 7.5cm Co-Axial Introducer Needle Angiotech, Gainesville, USA MCXS1612SX
18G / 20cm Trocar Needle Cook medical, Bloomington, USA DTN-18-20.0-U
16G / 20cm Quick-Core Biopsy Gun Cook Medical, Bloomington, USA G07827
Ilumien Optis PCI Optimization System (OCT & FFR) St. Jude medical, St. Paul, USA C408650 Part of Dragonfly Kit.
St. Jude medical, St. Paul, USA. (C4088643)
Dragonfly Duo Imaging Catheter LightLab Imaging, Westford, USA C408644 Part of Dragonfly Kit.
St. Jude medical, St. Paul, USA. (C4088643)
Sterile Dock Cover CFI Med. Solutions, Fenton, USA 200-700-00 Part of Dragonfly Kit.
St. Jude medical, St. Paul, USA. (C4088643)
5ml Luer-lock Syringe Merit Med. Syst., South Jordan, USA C408647
10ml Syringe BD, Franklin Lakes, USA 300912
18G Blunt Fill Needle BD, Franklin Lakes, USA 305180
21G Injection Needle BD, Franklin Lakes, USA 301155
Sterile scalpel BD, Franklin Lakes, USA 372611
NaCl 0,9% solution Braun, Melsungen AG, Germany 222434
Lidocaïne HCl 2% (20mg/ml) solution Braun, Melsungen AG, Germany 3624480
Sterile Ultrasound Gel, Aquasonic 100 Parker Lab. Inc., Fairfield, USA GE424609
Sterile Ultrasound Cover Microtek Med., Alpharetta, USA PC1289EU
Pathology Container
AMIRA software package FEI Visualization Sciences Group, Hillsboro, USA Software platform for 3D data analysis
FIJI software package (open source) Open source, http://fiji.sc/Fiji Open source image processing software

References

  1. Jemal, A., Siegel, R., Xu, J., Ward, E. Cancer statistics, 2010. CA Cancer J. Clin. 60, 277-300 (2010).
  2. Mathew, A., Devesa, S. S., Fraumeni, J. F., Chow, W. H. Global increases in kidney cancer incidence, 1973-1992. Eur. J. Cancer Prev. 11, 171-178 (2002).
  3. Volpe, A., et al. Contemporary management of small renal masses. Eur. Urol. 60, 501-515 (2011).
  4. Ljungberg, B., et al. EAU guidelines on renal cell carcinoma: the 2010 update. Eur. Urol. 58, 398-406 (2010).
  5. Donat, S. M., et al. Follow-up for Clinically Localized Renal Neoplasms. AUA Guideline, J. Urol. 190, 407-416 (2013).
  6. Faber, D. J., van der Meer, F. J., Aalders, M. C. G., van Leeuwen, T. G. Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography. Optics Express. 12, 4353-4365 (2004).
  7. Xie, T. Q., Zeidel, M. L., Pan, Y. T. Detection of tumorigenesis in urinary bladder with optical coherence tomography: optical characterization of morphological changes. Optics Express. 10, 1431-1443 (2002).
  8. Barwari, K., et al. Differentiation between normal renal tissue and renal tumours using functional optical coherence tomography: a phase I in vivo human study. BJU. Int. 110, E415-E420 (2012).
  9. Barwari, K., et al. Advanced diagnostics in renal mass using optical coherence tomography: a preliminary report. J. Endourol. 25, 311-315 (2011).
  10. Cauberg, E. C., et al. Quantitative measurement of attenuation coefficients of bladder biopsies using optical coherence tomography for grading urothelial carcinoma of the bladder. J. Biomed. Opt. 15, 066013 (2010).
  11. Bus, M. T., et al. Volumetric in vivo visualization of upper urinary tract tumors using optical coherence tomography: a pilot study. J. Urol. 190, 2236-2242 (2013).
  12. Wessels, R., et al. Optical coherence tomography in vulvar intraepithelial neoplasia. Journal of Biomedical Optics. 17, (2012).
  13. Yun, S. H., Tearney, G. J., de Boer, J. F., Iftimia, N., Bouma, B. E. High-speed optical frequency-domain imaging. Optics Express. 11, 2953-2963 (2003).
  14. Kodach, V. M., Kalkman, J., Faber, D. J., van Leeuwen, T. G. Quantitative comparison of the OCT imaging depth at 1300 nm and 1600 nm. Biomed. Opt. Express. 1, 176-185 (2010).
  15. Kinkelder, R., de Bruin, D. M., Verbraak, F. D., van Leeuwen, T. G., Faber, D. J. Comparison of retinal nerve fiber layer thickness measurements by spectral-domain optical coherence tomography systems using a phantom eye model. J. Biophotonics. 6, 314-320 (2013).
  16. Baxter, G. M., Sihdu, P. S. . Ultrasound of the Urogenital System. , (2006).
check_url/kr/52574?article_type=t

Play Video

Cite This Article
Wagstaff, P. G., Swaan, A., Ingels, A., Zondervan, P. J., van Delden, O. M., Faber, D. J., van Leeuwen, T. G., de la Rosette, J. J., de Bruin, D. M., Laguna Pes, M. P. In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses. J. Vis. Exp. (97), e52574, doi:10.3791/52574 (2015).

View Video