Summary

비보, 경피적, 니들 기반, 신장 질량의 빛 간섭 단층 촬영에서

Published: March 30, 2015
doi:

Summary

Optical coherence tomography (OCT) is a high resolution imaging technique that allows analysis of tissue specific optical properties providing the means for tissue differentiation. We developed needle based OCT, providing real-time imaging combined with on-the-spot tumor differentiation. This publication describes a method for percutaneous, needle based OCT of renal masses.

Abstract

Optical coherence tomography (OCT) is the optical equivalent of ultrasound imaging, based on the backscattering of near infrared light. OCT provides real time images with a 15 µm axial resolution at an effective tissue penetration of 2-3 mm. Within the OCT images the loss of signal intensity per millimeter of tissue penetration, the attenuation coefficient, is calculated. The attenuation coefficient is a tissue specific property, providing a quantitative parameter for tissue differentiation.

Until now, renal mass treatment decisions have been made primarily on the basis of MRI and CT imaging characteristics, age and comorbidity. However these parameters and diagnostic methods lack the finesse to truly detect the malignant potential of a renal mass. A successful core biopsy or fine needle aspiration provides objective tumor differentiation with both sensitivity and specificity in the range of 95-100%. However, a non-diagnostic rate of 10-20% overall, and even up to 30% in SRMs, is to be expected, delaying the diagnostic process due to the frequent necessity for additional biopsy procedures.

We aim to develop OCT into an optical biopsy, providing real-time imaging combined with on-the-spot tumor differentiation. This publication provides a detailed step-by-step approach for percutaneous, needle based, OCT of renal masses.

Introduction

지난 수십 신장 대중 1, 2의 발생률이 꾸준히 증가를 보여 주었다. 지금까지 신장 질량 치료 결정은 주로 MRI 및 CT 결상 특성, 나이 및 동반 질환에 기초하여 이루어지고있다. 그러나 이러한 진단 방법과 임상 매개 변수는 진정으로 신장 대량의 악성 가능성을 감지하는 기교가 부족하다. 핵심 조직 검사 또는 병리학 적 평가 (진단)에 대한 충분한 조직과 미세 침 흡인는 95~100% 3의 범위에서 민감도와 특이도 모두 객관적인 종양의 분화를 제공합니다. 따라서 조직 검사는 의심 신장 대중 4,5의 평가에 동의를 얻고있다. 그러나, 충분한 조직없이 생검 지연, 진단 또는 신장 실질 (비 – 진단) 정상에 전체 10 내지 20 %의 비율로 발생하고, 심지어 작은 신장 질량의 30 % 이하로 (<4cm, SRM들)을 수립 추가적인 대한 필요성으로 인해 자주 진단 과정조직 검사 절차 3,5.

광 결맞음 단층 영상 OCT (는) 신장 질량 분화에서 상기 장애물을 극복 할 수있는 잠재력을 갖는 신규 한 영상 기법이다. 근적외선 빛의 후방 산란에 기초하여, OCT를 2~3mm의 효과적인 조직 침투에 15㎛의 축 해상도 이미지를 제공한다 (도 1, 2). 조직 침투, 조직 특이 광산란 얻어진의 밀리미터 당 신호 세기의 손실 감쇠 계수로 표현된다 (μ OCT를 mm -1). 페이버 (6)에 의해 설명 된 바와 같이. 조직 학적 특성은 조직의 분화 (그림 3)에 대한 정량적 매개 변수를 제공 간섭 단층 값을 μ 상관 관계가 될 수있다.

발암 동안, 악성 세포는 수가 증가와 함께 더 크고 불규칙적 인 모양을 표시 핵 더 높은 굴절률 및 더 활성 미토콘드리아. 인해 세포 성분이 과발현, μ OCT의 변화에 영향을받지 양성 종양 조직 또는 악성 종양 (7)에 비교할 때 예상 할 수있다.

최근에 우리는 양성과 악성 신 대중 8,9 구별하는 표면의 OCT 능력을 공부했다. 16 명의 환자에서 종양 조직의 수술 중의 OCT 측정은 외부 배치의 OCT 프로브를 사용하여 수득 하였다. 동일한 환자의 조직의 영향을받지 않고 측정의 OCT 구성된 제어 암. 정상 조직은 종양의 OCT 분화 잠재력을 확인하는 악성 조직에 비해 상당히 낮은 중앙값 감쇠 계수를 나타내었다. 이러한 정량 분석은 이러한 urothelial 암종 10,11 외음부 상피 종양 분화 12 악성 조직의 다른 유형의 등급에 유사한 방식으로 적용되었다.

ENT는 "> 우리는 실시간 이미징에 현장 종양의 분화와 결합. 본 연구의 목적은 기반 경피적 바늘을 설명하는 것입니다 제공, 광학 생검으로 OCT를 개발하는 것을 목표로, 환자의 10월 방법은 진단 고체 강화 신장 질량.이 방법의 설명은 우리가 알고있는, 최초의 신장 종양의 바늘의 가능성을 기반으로 OCT를 평가합니다.

Protocol

제시된 절차는 대학 의료 센터 암스테르담, 등록 번호 NL41985.018의 임상 시험 심사위원회의 승인을 연구 프로토콜에서 발생한다. 서면 동의서는 모든 참가자가 필요합니다. 1. 시스템 이 실험을 위해, 1,280-1,350 nm 파장 대역 (13)에서 동작하는, 푸리에 도메인의 OCT 시스템을 사용한다. 푸리에 도메인 저 코 히어 런스 간섭계는 제 세대 시간 영역의 OCT 시스템에 비?…

Representative Results

제 25 종양 (23 명) 중 24의 OCT 성공적인 절차 총 수행 하였다. 하나의 경우 프로브 고장의 OCT 검사를 취득 할 수 없다는되었다. 설명 부분에서 상세히 설명된다 (AE)가 발생한 두 부작용. 일반 환자의 특성은 표 1에 있습니다. OCT를 콘솔 획득 한 데이터 세트의 즉각적인 질적 분석을 위해 리얼 타임 10 월 이미지를 제공하는 소프트웨어를 미리 설치했다. 추가 분석 및 ?…

Discussion

이 책에서 우리는 신장, 10월 기반 경피적 바늘의 가능성에보고한다. 이것은 "광 조직 검사"로 불리는 종양의 분화에 대한 임상 적용 기술에의 OCT 개발에 필수적인 첫 번째 단계입니다. 우리의 첫 번째 25 명의 환자는 쉽고 안전한 절차로 경피적 OCT를 보여 주었다. 광학 생검은 기존의 핵심 조직 검사를 통해 두 가지 장점이있다. 먼저, OCT 데이터의 실시간 수집 및 분석은 종래 병리학 처리 시…

Disclosures

The authors have nothing to disclose.

Acknowledgements

This work is funded by the Cure for Cancer Foundation, Dutch Technology Foundation (STW) and The Netherlands Organisation for Health Research and Development (ZonMw).

Materials

15G / 7.5cm Co-Axial Introducer Needle Angiotech, Gainesville, USA MCXS1612SX
18G / 20cm Trocar Needle Cook medical, Bloomington, USA DTN-18-20.0-U
16G / 20cm Quick-Core Biopsy Gun Cook Medical, Bloomington, USA G07827
Ilumien Optis PCI Optimization System (OCT & FFR) St. Jude medical, St. Paul, USA C408650 Part of Dragonfly Kit.
St. Jude medical, St. Paul, USA. (C4088643)
Dragonfly Duo Imaging Catheter LightLab Imaging, Westford, USA C408644 Part of Dragonfly Kit.
St. Jude medical, St. Paul, USA. (C4088643)
Sterile Dock Cover CFI Med. Solutions, Fenton, USA 200-700-00 Part of Dragonfly Kit.
St. Jude medical, St. Paul, USA. (C4088643)
5ml Luer-lock Syringe Merit Med. Syst., South Jordan, USA C408647
10ml Syringe BD, Franklin Lakes, USA 300912
18G Blunt Fill Needle BD, Franklin Lakes, USA 305180
21G Injection Needle BD, Franklin Lakes, USA 301155
Sterile scalpel BD, Franklin Lakes, USA 372611
NaCl 0,9% solution Braun, Melsungen AG, Germany 222434
Lidocaïne HCl 2% (20mg/ml) solution Braun, Melsungen AG, Germany 3624480
Sterile Ultrasound Gel, Aquasonic 100 Parker Lab. Inc., Fairfield, USA GE424609
Sterile Ultrasound Cover Microtek Med., Alpharetta, USA PC1289EU
Pathology Container
AMIRA software package FEI Visualization Sciences Group, Hillsboro, USA Software platform for 3D data analysis
FIJI software package (open source) Open source, http://fiji.sc/Fiji Open source image processing software

References

  1. Jemal, A., Siegel, R., Xu, J., Ward, E. Cancer statistics, 2010. CA Cancer J. Clin. 60, 277-300 (2010).
  2. Mathew, A., Devesa, S. S., Fraumeni, J. F., Chow, W. H. Global increases in kidney cancer incidence, 1973-1992. Eur. J. Cancer Prev. 11, 171-178 (2002).
  3. Volpe, A., et al. Contemporary management of small renal masses. Eur. Urol. 60, 501-515 (2011).
  4. Ljungberg, B., et al. EAU guidelines on renal cell carcinoma: the 2010 update. Eur. Urol. 58, 398-406 (2010).
  5. Donat, S. M., et al. Follow-up for Clinically Localized Renal Neoplasms. AUA Guideline, J. Urol. 190, 407-416 (2013).
  6. Faber, D. J., van der Meer, F. J., Aalders, M. C. G., van Leeuwen, T. G. Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography. Optics Express. 12, 4353-4365 (2004).
  7. Xie, T. Q., Zeidel, M. L., Pan, Y. T. Detection of tumorigenesis in urinary bladder with optical coherence tomography: optical characterization of morphological changes. Optics Express. 10, 1431-1443 (2002).
  8. Barwari, K., et al. Differentiation between normal renal tissue and renal tumours using functional optical coherence tomography: a phase I in vivo human study. BJU. Int. 110, E415-E420 (2012).
  9. Barwari, K., et al. Advanced diagnostics in renal mass using optical coherence tomography: a preliminary report. J. Endourol. 25, 311-315 (2011).
  10. Cauberg, E. C., et al. Quantitative measurement of attenuation coefficients of bladder biopsies using optical coherence tomography for grading urothelial carcinoma of the bladder. J. Biomed. Opt. 15, 066013 (2010).
  11. Bus, M. T., et al. Volumetric in vivo visualization of upper urinary tract tumors using optical coherence tomography: a pilot study. J. Urol. 190, 2236-2242 (2013).
  12. Wessels, R., et al. Optical coherence tomography in vulvar intraepithelial neoplasia. Journal of Biomedical Optics. 17, (2012).
  13. Yun, S. H., Tearney, G. J., de Boer, J. F., Iftimia, N., Bouma, B. E. High-speed optical frequency-domain imaging. Optics Express. 11, 2953-2963 (2003).
  14. Kodach, V. M., Kalkman, J., Faber, D. J., van Leeuwen, T. G. Quantitative comparison of the OCT imaging depth at 1300 nm and 1600 nm. Biomed. Opt. Express. 1, 176-185 (2010).
  15. Kinkelder, R., de Bruin, D. M., Verbraak, F. D., van Leeuwen, T. G., Faber, D. J. Comparison of retinal nerve fiber layer thickness measurements by spectral-domain optical coherence tomography systems using a phantom eye model. J. Biophotonics. 6, 314-320 (2013).
  16. Baxter, G. M., Sihdu, P. S. . Ultrasound of the Urogenital System. , (2006).
check_url/kr/52574?article_type=t

Play Video

Cite This Article
Wagstaff, P. G., Swaan, A., Ingels, A., Zondervan, P. J., van Delden, O. M., Faber, D. J., van Leeuwen, T. G., de la Rosette, J. J., de Bruin, D. M., Laguna Pes, M. P. In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses. J. Vis. Exp. (97), e52574, doi:10.3791/52574 (2015).

View Video