Materials
Name | Company | Catalog Number | Comments |
Butterfly iQ+ with USB-C 2.0 | Butterfly | n/a | Used to obtain one of the images |
Clarius L7HD Portable Ultrasound Machine | Clarius | n/a | Used to obtain one of the images |
Ultrasound Gel | Parker | n/a | Used to obtain all images |
Transparent dressing | 3M | 9534HP | Used to protect eye |
References
- Hansen, H. C., Helmke, K. Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests. Journal of Neurosurgery. 87 (1), 34-40 (1997).
- Bauerle, J., Lochner, P., Kaps, M., Nedelmann, M. Intra- and interobsever reliability of sonographic assessment of the optic nerve sheath diameter in healthy adults. Journal of Neuroimaging. 22 (1), 42-45 (2012).
- Lochner, P., et al. Intra- and interobserver reliability of transorbital sonographic assessment of the optic nerve sheath diameter and optic nerve diameter in healthy adults. Journal of Ultrasound. 19 (1), 41-45 (2016).
- Shokoohi, H., et al. Optic nerve sheath diameter measured by point-of-care ultrasound and MRI. Journal of Neuroimaging. 30 (6), 793-799 (2020).
- Montorfano, L., et al. Mean value of B-mode optic nerve sheath diameter as an indicator of increased intracranial pressure: A systematic review and meta-analysis. The Ultrasound Journal. 13 (1), 35 (2021).
- Jeon, J. P., et al. Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography. PLoS One. 12 (9), e0183170 (2017).
- Maissan, I. M., et al. Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure. Journal of Neurosurgery. 123 (3), 743-747 (2015).
- Sedwick, L. A., Burde, R. M. Unilateral and asymmetric optic disk swelling with intracranial abnormalities. American Journal of Ophthalmology. 96 (4), 484-487 (1983).
- Chen, L. M., et al. Ultrasonic measurement of optic nerve sheath diameter: a non-invasive surrogate approach for dynamic, real-time evaluation of intracranial pressure. British Journal of Ophthalmology. 103 (4), 437-441 (2019).
- Copetti, R., Cattarossi, L. Optic nerve ultrasound: artifacts and real images. Intensive Care Medicine. 35 (8), 1488-1489 (2009).
- Aspide, R., et al. A proposal for a new protocol for sonographic assessment of the optic nerve sheath diameter: The CLOSED protocol. Neurocrit Care. 32 (1), 327-332 (2020).
- Robba, C., et al. Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: A prospective observational study. PLoS Medicine. 14 (7), e1002356 (2017).
- Anas, I. Transorbital sonographic measurement of normal optic sheath nerve diameter in Nigerian adult population. The Malaysian Journal of Medical Sciences. 21 (5), 24-29 (2014).