Summary

Çoklanmış Immuno-histokimyasal boyanması ve Multispektral Görüntüleme kullanma Protein Ekspresyonu ve Co-lokalizasyon Kantifikasyonu

Published: April 08, 2016
doi:

Summary

Immunohistochemistry is a powerful lab technique for evaluating protein localization and expression within tissues. Current semi-automated methods for quantitation introduce subjectivity and often create irreproducible results. Herein, we describe methods for multiplexed immunohistochemistry and objective quantitation of protein expression and co-localization using multispectral imaging.

Abstract

Immunohistochemistry is a commonly used clinical and research lab detection technique for investigating protein expression and localization within tissues. Many semi-quantitative systems have been developed for scoring expression using immunohistochemistry, but inherent subjectivity limits reproducibility and accuracy of results. Furthermore, the investigation of spatially overlapping biomarkers such as nuclear transcription factors is difficult with current immunohistochemistry techniques. We have developed and optimized a system for simultaneous investigation of multiple proteins using high throughput methods of multiplexed immunohistochemistry and multispectral imaging. Multiplexed immunohistochemistry is performed by sequential application of primary antibodies with secondary antibodies conjugated to horseradish peroxidase or alkaline phosphatase. Different chromogens are used to detect each protein of interest. Stained slides are loaded into an automated slide scanner and a protocol is created for automated image acquisition. A spectral library is created by staining a set of slides with a single chromogen on each. A subset of representative stained images are imported into multispectral imaging software and an algorithm for distinguishing tissue type is created by defining tissue compartments on images. Subcellular compartments are segmented by using hematoxylin counterstain and adjusting the intrinsic algorithm. Thresholding is applied to determine positivity and protein co-localization. The final algorithm is then applied to the entire set of tissues. Resulting data allows the user to evaluate protein expression based on tissue type (ex. epithelia vs. stroma) and subcellular compartment (nucleus vs. cytoplasm vs. plasma membrane). Co-localization analysis allows for investigation of double-positive, double-negative, and single-positive cell types. Combining multispectral imaging with multiplexed immunohistochemistry and automated image acquisition is an objective, high-throughput method for investigation of biomarkers within tissues.

Introduction

İmmünohistokimya (IHC) doku içinde proteinin tespit edilmesi için standart bir laboratuar tekniğidir ve IHC hala yaygın olarak araştırma ve teşhis patoloji hem de kullanılır. İHK boyama değerlendirme sonuçlarının yorumlanması içine potansiyel önyargı tanıtan genellikle yarı-kantitatif olduğunu. Birçok yarı nicel yaklaşımlar son tanıya 1-4 içine boyanma yoğunluğu ve boyama ölçüde hem dahil olan geliştirilmiştir. Diğer sistemler daha iyi ifade 5. lokalize etmek için puanlama yoğunluğu ve hücre içi konumunu içerir. Birden fazla izleyiciler ortalama puanları Ortaklığın genellikle tek izleyici önyargı 6 etkilerini en aza indirmek için kullanılmaktadır. Bu çabalara rağmen, analiz öznellik hala 7 boyanma ölçüde değerlendirirken, özellikle kalır. İnsan girişten Protokol standardizasyon ve minimize öznellik doğru, tekrarlanabilir İHK sonuçlar yaratmak için her şeyden önemlidir.

içerik "> dokular içinde protein ifadesini belirlemek için İHK yanı sıra diğer seçenek vardır. Böyle immunoblotting gibi diğer teknikler, protein ifadesini araştırmak için altın standart olarak görülüyor ise araştırma ayarı içinde, immünhistokimya geleneksel, protein lokalizasyonu 8 incelemek için bir araç olarak görülmüştür . belirlenmesi doku veya hücre bölmesi özgü ifade doku slaytlar üzerinde floresan antikor kullanımı makul bir uzlaşma vardır. hücre parçalanması veya lazer yakalama mikrodiseksiyon 9,10 olarak gelişmiş teknikler içeren olmadan zordur, ama nedeniyle NADPH arka plan otofloresansı, lipofuscins, retiküler lifler, kollajen, elastin ve 11 doğru niceleme zorlaştırabilir.

Otomatik hesaplama patoloji platformları patoloji boyaması 12-15 daha objektif kantitatif için umut verici yönü vardır. Doku mikrodizinlerinde ile çok bantlı görüntüleme birleştirenbüyük örnek boyutlarda protein ekspresyonu yüksek verimli analizini kolaylaştırır. Kategorik biçimi 16 yerine, sürekli bir veri dönerken esas içsel hatalar ve analizi için gerekli zamanı hem de azaltarak, bu teknikler ile, protein, eş-lokalizasyonu, boyama heterojenliği ve doku ve hücre içi lokalizasyonu analizi mümkündür. Bu nedenle, bu çalışmanın amacı, çok bantlı görüntüleme yazılımı kullanılarak analiz ile çoklanmış immünohistokimyasal gerçekleştirmek için yararını ve metodolojisini göstermekti.

Bu protokol, dört optimize monoklonal antikorlar ile tek bir doku bölüm slayt kılavuzu, multipleks immünohistokimyasal için yazılmıştır. bir temsili olarak, çekirdek anti-tavşan östrojen reseptörü alfa (ÖRa) ve androjen reseptörü (AR) zara-bağlı anti-fare CD147 ve membrana bağlı anti-fare E-kaderin ile çoklanır. tercih edilen herhangi bir antikorun substitut edilebilirBurada listelenen antikorlar için ed, ancak antikorların her kombinasyonu ayrı optimizasyon gerektirir. Tüm antikorlar için ön işleme tabi tutulması aynı olmalıdır. AR ve CD147 antikorlar, bir kokteyl olarak ayrı ayrı ve optimize edilmelidir. Her antikor, biyotin-bir polimer sistemi ve 4 benzersiz kromojenler biri kullanılarak tespit edilir.

Protocol

Not: protokolü, burada daha önce tarif edilen 12,17,18 boyama ve doku mikrodizisi (TMA) analizini tarif eder. 4 um kalınlığında TMA bölümü, standart bir mikrotom kullanılarak parafin bloğu elde edilmiştir. NOT: 4 kromojenlerin ve karşıt için spektral kütüphane görüntü kantitatif için oluşturulmalıdır. Bunu yapmak için, her bir antikor için optimize protokol bir slayt başına antikor, eksi son counterstain ile çalıştırılmalıdır. Beşinci slayt spektral kütüphane oluşturmak için gerekli…

Representative Results

Şekil 1 'de, bir eğitim olmayan doku bölümünde birlikte, stromal ve epitelyal kısımlarına kademeli görüntüleri prostat dokuları üzerinde gerçekleştirilir. Epitelyal membran markör E-kadherin kullanarak, hücre parçalara ayırma, Şekil 2'de gösterilen çekirdek, sitoplazma ve membran kısımları, ayrı yapıldı. Bir deneyde, Şekil 3'te gösteri…

Discussion

Protein ifade değerlendirmek için geleneksel immunohistokimyasal kullanımı analizi 22,23 öznel, yarı nicel yöntemler ile sınırlıdır. Peşin platformları biyobelirtecin ifade ve lokalizasyon yüksek verimlilik analizi için yaratılmıştır. doku ve hücre içi bölmeleri hem Detaylı segmentasyon kullanıcıları diğer ilgi işaretleri ile biyobelirteç ifade, yerelleştirme ve ko-lokalizasyon çalışma sağlar. Daha önceki çalışmalarda, aynı hücresel bölme 18,20,21 lokalize p…

Declarações

The authors have nothing to disclose.

Acknowledgements

Yazarlar kendi imkanları ve hizmetlerin kullanımı için, Patoloji ve Laboratuar Tıp UW Bakanlığı tarafından desteklenen bir parçası ve UWCCC hibe P30 CA014520 olarak, Patoloji laboratuvarında Wisconsin çeviriyle ilgili araştırma Girişimleri Üniversitesi teşekkür ederim.

Materials

Xylene Fisher Chemical X3F1GAL NFPA rating:Health – 2, Fire – 3 , Reactivity-0
Ethyl Alcohol-200 proof Fisher Scientific 4355223 NFPA rating:Health – 0, Fire – 3 , Reactivity-0
Tris Base Fisher Scientific BP152-500 NFPA rating:Health – 2, Fire – 0 , Reactivity-0
Tris Hydroxymethyl aminomethane HCl Fisher Scientific BP153-1 NFPA rating:Health – 2, Fire – 0 , Reactivity-0
Tween 20 Chem-Impex 1512 NFPA rating:Health – 0, Fire –1 , Reactivity-0
Phosphate-buffered saline Fisher Scientific BP2944-100 NFPA rating:Health – 1, Fire –0 , Reactivity-0
Peroxidazed Biocare Medical PX968 Avoid contact with skin and eyes. May cause skin irritation and eye damage.
Diva Decloaker  Biocare Medical DV2004 This product has been classified as non‐hazardous based on the physical  and/or  chemical nature and/or concentration of ingredients. 
Estrogen Receptor alpha Thermo Fisher Scientific-Labvision RM9101 Not classified as hazardous
Androgen Receptor SCBT sc-816 Not classified as hazardous
CD147 Biodesign P87535M Not classified as hazardous
E-cadherin Dako M3612 Not classified as hazardous
Renoir Red Andibody Diluent Biocare Medical PD904 It is specially designed to work with Tris-based antibodies
DeCloaking Chamber  Biocare Medical Model DC2002 Take normal precautions for using a pressure cooker
Barrier pen-Immuno Edge  Vector Labs H-4000
Denaturing Kit-Elution step Biocare Medical DNS001H Not classified as hazardous
Mach 2 Goat anti-Rabbit HRP Polymer Biocare Medical RHRP520 Not classified as hazardous
Mach 2 Goat anti-Rabbit AP Polymer Biocare Medical RALP525 Not classified as hazardous
Mach 2 Goat anti-Mouse HRP Polymer Biocare Medical M3M530 Not classified as hazardous
Betazoid DAB Chromogen Kit Biocare Medical BDB2004 1. DAB is known to be a suspected carcinogen.
2. Do not expose DAB components to strong light or direct sunlight.
3. Wear appropriate personal protective equipment and clothing.
4. DAB may cause sensitization of skin. Avoid contact with skin and eyes.
5. Observe all federal, state and local environmental regarding disposal
Warp Red Chromogen Kit Biocare Medical WR806 Corrosive. Acid that may cause skin irritation or eye damage. 
Vina Green Chromogen Kit Biocare Medical BRR807 Harmful if swallowed
Bajoran Purple Chromogen Kit Biocare Medical BJP807 Flammable liquid. Keep away from heat, flames and sparks. Harmful by ingestion or absorption. Avoid contact with skin or eyes, and avoid inhalation.
Cat Hematoxylin Biocare Medical CATHE Purple  solution  with  a  mild  acetic  acid  (vinegar)  scent.  May  be
 irritating  to  skin  or  eyes.  Avoid  contact  with  skin  and  eyes.  Avoid  ingestion.
XYL Mounting Media Richard Allen 8312-4 NFPA rating:Health – 2, Fire – 3 , Reactivity-0
1.5 Coverslips Fisher Brand 22266858 Sharp edges
Incubation (Humidity)Chamber obsolete obsolete Multiple vendors available
Convection Oven Stabil- Therm C-4008-Q
Background Punisher Blocking Reagent Biocare Medical BP974 This product is not classified as hazardous. 
inForm software PerkinElmer CLS135781 Primary multispectral imaging software used in manuscript
Nuance software PerkinElmer NUANCEEX Software used for making spectral libraries within manuscript
Vectra microscope and slide scanner PerkinElmer VECTRA Automated slide scanner and microscope for obtaining IM3 image cubes

Referências

  1. Valdman, A., et al. Expression of redox pathway enzymes in human prostatic tissue. Anal Quant Cytol Histol. 31 (6), 367-374 (2009).
  2. Rimm, D. L., Camp, R. L., Charette, L. A., Olsen, D. A., Provost, E. Amplification of tissue by construction of tissue microarrays. Exp Mol Pathol. 70 (3), 255-264 (2001).
  3. Jonmarker, S., et al. Expression of PDX-1 in prostate cancer, prostatic intraepithelial neoplasia and benign prostatic tissue. APMIS. 116 (6), 491-498 (2008).
  4. McCarty, K. S., Miller, L. S., Cox, E. B., Konrath, J., McCarty, K. S. Estrogen receptor analyses. Correlation of biochemical and immunohistochemical methods using monoclonal antireceptor antibodies. Arch Pathol Lab Med. 109 (8), 716-721 (1985).
  5. Volante, M., et al. Somatostatin receptor type 2A immunohistochemistry in neuroendocrine tumors: a proposal of scoring system correlated with somatostatin receptor scintigraphy. Mod Pathol. 20 (11), 1172-1182 (2007).
  6. Muris, J. J., et al. Immunohistochemical profiling of caspase signaling pathways predicts clinical response to chemotherapy in primary nodal diffuse large B-cell lymphomas. Blood. 105 (7), 2916-2923 (2005).
  7. Jaraj, S. J., et al. Intra- and interobserver reproducibility of interpretation of immunohistochemical stains of prostate cancer. Virchows Arch. 455 (4), 375-381 (2009).
  8. Nakane, P. K., Pierce, G. B. Enzyme-labeled antibodies: preparation and application for the localization of antigens. J Histochem Cytochem. 14 (12), 929-931 (1966).
  9. Peters, T. J. Investigation of tissue organelles by a combination of analytical subcellular fractionation and enzymic microanalysis: a new approach to pathology. J Clin Pathol. 34 (1), 1-12 (1981).
  10. Emmert-Buck, M. R., et al. Laser Capture Microdissection. Science. 274 (5289), 998-1001 (1996).
  11. Waters, J. C. Accuracy and precision in quantitative fluorescence microscopy. J Cell Biol. 185 (7), 1135-1148 (2009).
  12. Huang, W., Hennrick, K., Drew, S. A colorful future of quantitative pathology: validation of Vectra technology using chromogenic multiplexed immunohistochemistry and prostate tissue microarrays. Hum Pathol. 44 (1), 29-38 (2013).
  13. Rimm, D. L. C-Path: A Watson-Like Visit to the Pathology Lab. Science Translational Medicine. 3 (108), (2011).
  14. Fiore, C., et al. Utility of multispectral imaging in automated quantitative scoring of immunohistochemistry. J Clin Pathol. 65 (6), 496-502 (2012).
  15. Stack, E. C., Wang, C., Roman, K. A., Hoyt, C. C. Multiplexed immunohistochemistry, imaging, and quantitation: A review, with an assessment of Tyramide signal amplification, multispectral imaging and multiplex analysis. Methods. 70 (1), 46-58 (2014).
  16. Rizzardi, A. E., et al. Quantitative comparison of immunohistochemical staining measured by digital image analysis versus pathologist visual scoring. Diagn Pathol. 7, 42 (2012).
  17. Bauman, T. M., et al. Characterization of fibrillar collagens and extracellular matrix of glandular benign prostatic hyperplasia nodules. PLoS One. 9 (10), e109102 (2014).
  18. Bauman, T. M., et al. Beta-catenin is elevated in human benign prostatic hyperplasia specimens compared to histologically normal prostate tissue. Am J Clin Exp Urol. 2 (4), 313-322 (2014).
  19. Bauman, T. M., Ewald, J. A., Huang, W., Ricke, W. A. CD147 expression predicts biochemical recurrence after prostatectomy independent of histologic and pathologic features. BMC Cancer. 15 (1), 549 (2015).
  20. Bauman, T. M., et al. Finasteride treatment alters tissue specific androgen receptor expression in prostate tissues. Prostate. 74 (9), 923-932 (2014).
  21. Nicholson, T. M., Sehgal, P. D., Drew, S. A., Huang, W., Ricke, W. A. Sex steroid receptor expression and localization in benign prostatic hyperplasia varies with tissue compartment. Differentiation. 85 (4-5), 140-149 (2013).
  22. Taylor, C. R., Levenson, R. M. Quantification of immunohistochemistry–issues concerning methods, utility and semiquantitative assessment II. Histopathology. 49 (4), 411-424 (2006).
  23. Matos, L. L., Trufelli, D. C., de Matos, M. G., da Silva Pinhal, M. A. Immunohistochemistry as an important tool in biomarkers detection and clinical practice. Biomark Insights. 5, 9-20 (2010).
  24. Kononen, J., et al. Tissue microarrays for high-throughput molecular profiling of tumor specimens. Nat Med. 4 (7), 844-847 (1998).
  25. Ong, C. W., et al. Computer-assisted pathological immunohistochemistry scoring is more time-effective than conventional scoring, but provides no analytical advantage. Histopathology. 56 (4), 523-529 (2010).
check_url/pt/53837?article_type=t

Play Video

Citar este artigo
Bauman, T. M., Ricke, E. A., Drew, S. A., Huang, W., Ricke, W. A. Quantitation of Protein Expression and Co-localization Using Multiplexed Immuno-histochemical Staining and Multispectral Imaging. J. Vis. Exp. (110), e53837, doi:10.3791/53837 (2016).

View Video