Competitive Binding Assay to Identify Compounds Disrupting Receptor-Ligand Interactions

Published: June 29, 2023

Abstract

Source: Schoofs, G., et al. A Flow Cytometry-based Assay to Identify Compounds That Disrupt Binding of Fluorescently-labeled CXC Chemokine Ligand 12 to CXC Chemokine Receptor 4. J. Vis. Exp. (2018).

In this video, we describe a flow cytometry-based competitive binding assay to detect the interactions between the CXC Chemokine Receptor 4 (CXCR4) and its fluorescently-labeled natural ligand CXC Chemokine Ligand 12 (CXCL12), in the presence of a CXCR4-targeting small molecule. Incubating CXCR4-expressing cells with lower small molecule concentrations allows CXCR4-CXCL12 binding to some extent, which progressively declines upon a gradual increase in small molecule concentrations.

Protocol

1. Preparation of CXCL12, Assay Buffer, and Jurkat Cells for the Competition Binding Assay Prepare a stock solution of CXCL12AF647 (20 µg/mL; see Table of Materials and Reagents) by dissolving the lyophilized reagent (stored at -80 °C, in the dark) in ultrapure water supplemented with 0.01% (volume/volume) of Polysorbate 20. Store single-use aliquots from this stock solution at -80 °C, protected from light. Prepare assay buffer by adding 40…

Representative Results

Figure 1: Overview of the workflow and illustration of the type of data obtained. (A). The main steps of the protocol are schematized for the negative and positive control samples, and compound-treated samples. Samples without compound pre-incubation and without addition of fluorescently labeled chemokine (CXCL12AF647) are included to determine the background (auto)flu…

Disclosures

The authors have nothing to disclose.

Materials

BD FACSCanto II Becton Dickinson Not applicable Flow cytometry device
BD FACSDIVA Software
BD FACSArray Becton Dickinson Not applicable Flow cytometry device
BD FACSArray System Software
Rapid flow filter: 0.2 μm aPES  Thermo Scientific  566-0020
FlowJo FlowJo is now a wholly owned subsidiary of BD.
Vi-CELL Beckman Coulter Not applicable Cell viability analyzer
Sigma 3-18 KS Sigma Not applicable Centrifuge
AMD3100 Sigma A5602-5mg Specific CXCR4 antagonist
h-SDF1a (AF647) ALMAC CAF-11-B-01 Fluorescently-labeled CXCL12, CXCL12AF647
Sterilin microtiter plate, 96-well, U
bottom, clear
Thermo Scientific 611U96
Bovine Serum Albumin (BSA) Sigma A1933-25G
HBSS (10x), calcium, magnesium, no phenol red Gibco (Life Technologies) 14065-049
HEPES (1M) Gibco (Life Technologies) 15630-056
Dulbecco's Phosphate Buffered Saline (DPBS) Gibco (Life Technologies) 14190-094
Jurkat cells ATCC
Reagent reservoir PP Sigma BR703411
Falcon tubes, 50ml Greiner Bio-One 227 261

Tags

check_url/21451?article_type=t

Play Video

Cite This Article
Competitive Binding Assay to Identify Compounds Disrupting Receptor-Ligand Interactions. J. Vis. Exp. (Pending Publication), e21451, doi: (2023).

View Video